Directorate Of Municipal Administration Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 16,900Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/WS/WORK_INDENT27168Bid Award Id
ViewTender No
DMA/2024-25/WS/WORK_INDENT27168Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Code04 - Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) PWD CSR 202324, VolII, P. No. 111, I. No. 12.92
29.16
6557
191209.41
Code05 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVCplain & brass threaded fittings, ic fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVCsolvent cement and the cost of cutting chases and making good thesame including testing of joints complete as per direction of Engineer inCharge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes PWD CSR 202324, VolII, P. No. 122, I. No. 13.32.2
150
397
59692.5
Code06 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD CSR 202324, VolII, P. No. 123, I. No. 13.34
8000
9
75600
Code07 - Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A, including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion, (i) single socketed pipes 100 mm diameter PWD CSR 202324, VolII, P. No. 125, I. No. 13.48
75
305
22916.25
Code08 - Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete PWD CSR 202324, VolII, P. No. 127, I. No. 13.59
50
231
11550
Code09 - Providing & fixing White vitreous china water closet squatting pan (Indian type) along with S or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material ic malba, all complete as per the direction of Engineerin charge Orissa pattern W.C Pan of size 580x440 mm (PWD CSR 202324, VolII, P. No. 202, I. No. 20.44.2)
18
3724
67038.3
Code10 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid PWD CSR 202324, VolII, P. No. 131, I. No. 14.3.1
5
6275
31379.25
Code11 - Concealed PVC Conduit System Supplying heavy gauge PVC Conduit Pipe dia. mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1920 mm dia 2mm thick (P.no.2.it.no.1.1.1) (PWD CSR for Electrical Works for the Year 202324)
100
72
7245
Code12 - PVCmetal conduit Deep Junction Box Supplying and fixing PVCmetal conduit Deep junction box 1920mm Deep Junction Box (P.no.2.it.no.1.5) (PWD CSR for Electrical Works for the Year 202324)
5
51
257.25
Code13 - Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8 x 6 x 3 (203 x 152 x 76 mm) (P.no.3.it.no.1.6.4) (PWD CSR for Electrical Works for the Year 202324)
5
90
451.5
Code14 - Wiring for lightingpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latest amendments.4 Sqmm (P.no.5.it.no.2.3.4) (PWD CSR for Electrical Works for the Year 2023 24)
75
66
4961.25
Code15 - Modular SwitchesSocketsRegulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps two way. (P.no.9.it.no.3.6.2) (PWD CSR for Electrical Works for the Year 202324)
15
174
2614.5
Code16 - 4mm Thick Plastic Sheets Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. (P.no.9.it.no.3.8) (PWD CSR for Electrical Works for the Year 202324)
5000
-
2150
Code17 - Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing woodenpanel using necessary nuts, bolts and washers. 32Amps P.no.10.it.no.5.7.2) (PWD CSR for Electrical Works for the Year 202324)
5
253
1265.25
Code18 - Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632 Amps DP .(p.no.17.it.no.5.18.4) (PWD CSR for Electrical Works for the Year 202324)
5
775
3879.75
Code19 - PVC Batten with LED Tubes Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70Percent lumen maintenance with CRI 80. Power Input 220240V at 5060Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4 2022 w (p.no.43.it.no.11.3.2) (PWD CSR for Electrical Works for the Year 202324)
30
724
21735
Code20 - Lamp Holder Supplying & Fixing of 70150 Watts lamp holder 2 Pin (p.no.52.it.no.12.46) (PWD CSR for Electrical Works for the Year 202324)
30
66
1984.5
Code21 - Fixing all type of Luminaries Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 230.0076 twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall ceiling Rafter Girders (p.no.56.it.no.13.7.1) (PWD CSR for Electrical Works for the Year 202324)
30
128
3843
Code22 - Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to3263Athreephase4wirewholecurrentclass1AccuracyEnergyMeter. (PWD CSR for Electrical Works for the Year 202324 P.no.30.it.no.5.35)
5
5990
29951.25
Code23 - Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipmentsonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmallroundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia . (PWD CSR for Electrical Works for the Year 202324 P.no.54.it.no.12.56)
5
3685
18427.5
Code24 - Constructing masonry Chamber 30x30x50 cm inside, in brickwork in cement mortar 14 (1 cement 4 coarse sand) with C.I. surface box 100x100 x75 mm (inside) with hinged cover fixed incement concrete slab 124 mix (1 cement 2 coarse sand 4 gradedstone aggregate 20 mm nominal size), ic necessary excavation,foundation concrete 1510 ( 1 cement 5 fine sand 10 graded stoneaggregate 40mm nominal size ) and inside plastering with cementmortar 13 (1 cement 3 coarse sand) 12mm thick, finished witha floating coat of neat cement complete as per standard design With common burnt clay (non modular) bricks of class designation 3.5. (PWD CSR 202324 P.no.125.it.no.13.51)
7
1791
12539.1
Code25 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m PWD SR 202324 Vol1 P.NO.10 I.No1.17.1
13.5
275
3713.85
Code26 - Refilling available earth around trenchespipelines, cables in layers not
exceeding 20 cms in depth, compacting each deposited layer by ramming afterwatering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications PWD SR 202324 Vol1 P.NO.7 I.No1.10
13.5
168
2268
Code27 - Geophysical investigation at site for sinking borewells for Providingdrinking water to the habitation either through the Hand Pump MWSor P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergerss method, including reconnaissance survey of geologicalformation. Geophysical investigation of existing ground water in thevicinity, its quality, quantity and acceptability of the users, indicatingthe location of the site, recommended depth of casing pipe required toseal the top unconsolidated formation including an extra depth of 1.0metre in consolidated formation for proper seating of casing pipe, depthof drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportationof instruments and accessories to work site, engaging technical personaland labour required etc. NOTE 1) Additional rate on item 1&2 isallowed for drilling in over burden and fixing Casing pipes beyond 20M (for fixing Casing pipes only) a) Above 20 M and upto 30 M 15Percent,b) Above 30 M 30Percent (Measurement of overburden is restricted to thedepth of casing pipe fixed excluding initial depth of 20M and projectionabove ground level). 2) A sum of Rs. 100 is to be deducted for DryBorewell towards yield test. etc. complete.
2
5552
11104.8
Code28 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for Borewell depth of 0 to 50 m
100
324
32445
Code29 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for Borewell depth of 50 to 100 m Borewell depth of 0 to 50 Mtrs
10
406
4063.5
Code30 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.PVC pipes of 6 Kgcm2 for 140mm(3.097)
36
359
12927.6
Code31 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of SD Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE 1) DOLDirect Online Starter 2) SD Star Delta Starter Upto 3 HP pumps
2
6825
13650
Code32 - Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 882281978 and its latest amendments and with ISI Mark of 61016202540 Amps with scalable box.
2
1207
2415
Code33 - Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch)
suitable for bore well confirming to IS 80342000 specifications, to work
site with testing of as per instructions of engineer incharge of work and latest amendment etc. complete.12 STG PWD SR 202324 Vol5 P.NO.149 I.No13.6.3
2
15241
30483.6
Code34 - Supply and delivery at site Brand new best make PVC insulated cable of
Flat 3 core (sheathed) of nominal cross sectional area as per IS 6941990
with ISI Mark and as per its latest amendments. 1x3x4 Sqm PWD SR 202324 Vol5 P.NO.154 I.No13.22.3
100
141
14175
Code35 - Providing main connection from pole PVC insulated sheathed steel wire
cable in GI pipe as per IS 1554 1988 with latest amendments with ISI
mark from KPTCL pole to meter board unit. 13.37 PWD SR 202324 Vol5 P.NO.156 I.No13.37
50
89
4462.5
Code36 - Providing PVC ringtite pipes conforming to IS 49852000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinationsand cuts of pipes wherever necessary including jointing of PVC pipesand specials (excluding cost of specials) with jointing of approvedtype, with all labour with all lead & lift including encasing the pipealround to a depth of not less than 15 cms. with soft gravel or selectedearth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will makehis own arrangements for procuring water for testing) etc. complete For PVC pipes 25mm dia, 10 kgsqcm & class 5 PWD SR 202324 Vol5 P.NO.113 I.No10.1.1
100
50
5040
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements