Directorate Of Municipal Administration Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 1,69,000Document Cost
Refer DocumentsTender Fee
₹ 2,120
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/BD/WORK_INDENT31982Tender No
DMA/2024-25/BD/WORK_INDENT31982Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Item Code 4 - KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)
8.89
11793
104845.104
... More
Item Code 5 - KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)
65.7
7776
510883.2
... More
Item Code 6 - KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)
8.2
10264
84167.424
... More
Item Code 7 - KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)
9.03
100191
904732.3152
... More
Item Code 8 - KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)
32.75
7155
234348.52
... More
Item Code 9 - KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)
360.89
530
191589.2832
... More
Item Code 10 - KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)
134.64
1378
185630.8608
... More
Item Code 11 - KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)
293.04
330
96820.416
... More
Item Code 12 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)
21800
126
2759008
... More
Item Code 13 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)
1159.38
636
737551.1808
... More
Item Code 14 - KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)
293.04
112
32820.48
... More
Item Code 15 - KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)
134.64
81
11008.1664
... More
Item Code 16 - KSRB 8-8.75.2 : Finishing walls with premium acrylic smooth Exterior paint of required shade :old work (one coats applied @ 0.83 1/10m2) including reparing surface after thoroughly cleaning the surface to remove all dirt ,dust and foreign matter,cost of materials labour complete as per specification and as per directions of Engineer in charge.(Item No. 8.75.2, Page No. 53, Vol.2)
134.64
81
11008.1664
... More
Item Code 17 - KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)
29.25
2948
86257.08
... More
Item Code 18 - KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)
2
27648
55296.64
... More
Item Code 19 - KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)
300
506
151872
... More
Item Code 20 - Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet.Short point upto 3mtr form tapping point to out let via switch(Refer KPWD SR 2022/23 Page 3 Sl. No. 2.2.1)
10
251
2510
... More
Item Code 21 - Medium point above 3Mtr upto 6mtr from tapping point to outlet via switch (Refer KPWD SR 2022/23 Page 3 Sl. No. 2.2.2)
25
361
9025
... More
Item Code 22 - Long point above 6 mtr upto 10mtr from tapping point to out let via switch (Refer KPWD SR 2022/23 Page 3 Sl. No. 2.2.3)
25
542
13550
... More
Item Code 23 - Two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switches(Refer KPWD SR2022/23 Page 3 Sl. No. 2.2.4)
5
671
3355
... More
Item Code 24 - Open Conduit System : Supplying heavy gauge PVC conduit pipe ....... dia ....... mmthick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20mm dia 2mm thick (Refer KPWD SR 2022/23 Page 1 Sl. No. 1.1.1)
250
68
17000
... More
Item Code 25 - 25mm dia 2mm thick(Refer KPWD SR 2022/23 Page 1 Sl. No. 1.1.2)
150
80
12000
... More
Item Code 26 - 32mm dia 2mm thick (Refer KPWD SR 2022/23 Page 1 Sl. No. 1.1.3)
50
100
5000
... More
Item Code 27 - Groove cutting :Supplying...dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary.19/20mm dia 2mm thick (Refer KPWD SR 2022/23 Page 1 Sl. No. 1.3.1)
100
75
7500
... More
Item Code 28 - 25mm dia 2m thick (Refer KPWD SR 2022/23 Page 1 Sl. No. 1.3.2)
100
80
8000
... More
Item Code 29 - 32mm dia 2.5mm thick (Refer KPWD SR 2022/23 Page 1 Sl. No. 1.3.3)
50
105
5250
... More
Item Code 30 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 1.5 sqmm (Refer KPWD SR 2022/23 Page 3 Sl. No. 2.3.2)
200
26
5200
... More
Item Code 31 - 2.5 sqmm (Refer KPWD SR 2022/23 Page 3 Sl. No. 2.3.3)
200
40
8000
... More
Item Code 32 - 4 sqmm (Refer KPWD SR 2022/23 Page 3 Sl. No. 2.3.4)
300
59
17700
... More
Item Code 33 - 6 sqmm (Refer KPWD SR 2022/23 Page 3 Sl. No. 2.3.5)
200
87
17400
... More
Item Code 34 - Supplying and fixing of Metal Fan Box with Round Hook. (Refer KPWD SR 2022/23 Page 2 Sl. No. 1.12)
20
163
3260
... More
Item Code 35 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 1 - 3 Way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.4.1)
20
123
2460
... More
Item Code 36 - 4 - 5 Way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.4.2)
1
138
138
... More
Item Code 37 - 6 Way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.4.3)
5
212
1060
... More
Item Code 38 - 8 Way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.4.4)
2
250
500
... More
Item Code 39 - 10-12 Way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.4.5)
3
325
975
... More
Item Code 40 - 16-18Way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.4.6)
5
354
1770
... More
Item Code 41 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module (Refer KPWD SR 2022/23 Page 5 Sl. No.3.5.1)
10
152
1520
... More
Item Code 42 - 4 Module (Refer KPWD SR 2022/23 Page 5 Sl. No.3.5.2)
1
175
175
... More
Item Code 43 - 6 Module ( Refer KPWD SR 2022/23 Page 5 Sl. No.3.5.3)
5
244
1220
... More
Item Code 44 - 8 Module (Refer KPWD SR 2022/23 Page 5 Sl. No.3.5.4)
2
302
604
... More
Item Code 45 - 10-12 Module (Refer KPWD SR 2022/23 Page 5 Sl. No.3.5.5)
3
363
1089
... More
Item Code 46 - 16-18 Module (Refer KPWD SR 2022/23 Page 5 Sl. No.3.5.6)
5
403
2015
... More
Item Code 47 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.6A one way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.6.1)
40
88
3520
... More
Item Code 48 - 6A two way (Refer KPWD SR 2022/23 Page 5 Sl. No.3.6.2)
1
152
152
... More
Item Code 49 - 6A three way socket. (Refer KPWD SR 2022/23 Page 5 Sl. No.3.6.3)
5
162
810
... More
Item Code 50 - Stepped Fan Regulator. (Refer KPWD SR 2022/23 Page 5 Sl. No.3.6.4)
10
313
3130
... More
Item Code 51 - 16A one way switch.(Refer KPWD SR 2022/23 Page 5 Sl. No.3.6.8)
5
249
1245
... More
Item Code 52 - 32A DP switch .(Refer KPWD SR 2022/23 Page 5 Sl. No.3.6.10)
5
375
1875
... More
Item Code 53 - 6/16A Universal Socket.(Refer KPWD SR 2022/23 Page 5 Sl. No.3.6.11)
5
249
1245
... More
Item Code 54 - Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898.5 - 32 Amps SP (Refer KPWD SR 2022/23 Page 13 Sl. No. 5.17.1)
5
523
2615
... More
Item Code 55 - 6-32 Amps DP (Refer KPWD SR 2022/23 Page 13 Sl. No. 5.17.4)
5
1103
5515
... More
Item Code 56 - 16-25A,2P,RCCB (Refer KPWD SR 2022/23 Page 13 Sl. No 5.19.1)
1
4548
4548
... More
Item Code 57 - Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.16 way SP &N (Refer KPWD SR 2022/23 Page 13 Sl. No 5.18.10)
1
2650
2650
... More
Item Code 58 - Fixing all types and all capacities of flouroscent / false ceiling / spot light / CFL / LED fittings on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required nos. of round blocks & clamps.On wall / ceiling / rafter / girders. (Refer KPWD SR 2022/23 Page 45 Sl. No.13.7.1)
30
119
3570
... More
Item Code 59 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring. (Refer KPWD SR 2022/23 Page 46 Sl. No.13.10)
14
162
2268
... More
Item Code 60 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia - (Refer KPWD SR 2019/20 Page 40 Sl. No. 6.2)
1
4150
4150
... More
Item Code 61 - Supplying and running of GI/copper strips for grounding connections using necessary fixing materials as required.8 SWG copper wire (Refer KPWD SR 2019/20 Page 44 Sl. No. 6.18.6)
30
105
3150
... More
Item Code 62 - Supplying of .....feet -PVC Batten with integrated LED tube .... Wwith high quality diffuser with Life of 25000 burning hours 70lumen maintenance with CRI 80. Power Input: 220-240V50/60Hz & Power factor 0.9 along with CE approved. 2 yearsWarranty against any manufacturing defect working under standardelectrical condition
30
1269
38070
... More
Item Code 63 - Supplying of 1440rpm heavy duty exhaust fan with bracket bladessuitable to operate on 230V 50Hz, AC Supply complete15" Sweep (450 mm)
8
4446
35568
... More
Item Code 64 - Supply, Erection, testing and commissioning of AMF panel suitablefor .....kVA DG set. The panel is of cubical type base/floor mountingcontrol panel with hinged doors, undrilled bottom gland plate, aluminium
Bus Bar with the accommodation for .....A 4 pole contactor for alternatorwith thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse forshort circuit protection, Microprocessor based AMF module with supply
failure timer, Restoration timer, 3 impulse automatic engine start/stoplogic, Mains/generator voltage, ....capacity bypass switch and frequencysensing, PCC 1301controller with water temperature/Lube oil pressure/
engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, Noof starts, Fault indication, over / under speed, Fails to start, Low oilpleasure, High engine temperature, Under/over voltage, over current, Earth
fault relay, with indications for Mains on, Load on Mains, Battery chargeron Push buttons AMF module by pass Mode, Battery charger unit withinbuilt Auto/Manual and Flat/Boost facility. The complete set shall havesufficient safety and adhere to NEC, NBC 2016, IEC, CPWDspecifications, PCB norms and KSGEI Acts and Rules15 KVA to 30 KVA (Refer KPWD SR 2023-24 Page Sl. No. 10.2.1)
1
58711
58711
... More
Item Code 65 - Supplyingof Ceiling Fan with Capacitor rating As perguideline of BEE 5 star rating and IS374/79 and also comply with IS1709/1984 with latest amendment ,Rated voltage 220V/50Hz, Rated power input 48 W 10 Rated current As per IS374/79, Rated power factor 0.9l agging(min), Rated speed 350 10RPM, Rated airdelivery210+/-10CubicMeterMinimum, Rated servicevalue 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thickAluminiumAlloy sheet,Class B motor insulation, Bearing Twoball bearings, Top 6202, Bottom 6201, as per IS specification,Motor winding. Temp rise Shall not exceed 75 deg C over andambientof 400C byresistancemethodat 245V, Insulationresistance Shall not be less than Two Mega Ohms (2MOhms),LeakagecurrentShouldnotexceed210Micro Amp, Powerinput,Wcurrent,AirDelivery&Fan StpperIS374/1979withlatestamendment,2yearmanufacturer Warranty.
6
2677
16062
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements