Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 1,26,000Document Cost
Refer DocumentsTender Fee
₹ 1,230
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2023-24/EL/WORK_INDENT16053/CALL-2Tender No
DMA/2023-24/EL/WORK_INDENT16053/CALL-2Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
54.02 - 54.02) Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg
each
30
710
21300
54.03 - 54.03) Good Quality Salt for grounding purposes packed in 50 Kg gunny bag
30
326
9780
1.6.1 - Digging of Pit for providing GI Pipe type Earthing 1.6.1 ordinary soil
30
786
23593.5
32.18 - 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975
228) 32.18) 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)
0.75
905799
679349.25
21.07 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 tio 240 SQ mm 21.07
0.75
33891
25418.925
32.14 - 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975
224 32.14 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)
0.1
391876
39187.6
21.06 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 sqmm 21.06
0.1
32695
3269.595
32.08 - 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975
218) 32.08) 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)
0.2
146526
29305.2
32.04 - 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975
214) 32.04) 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)
6
92839
557034
21.05 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff2.5 to 25 Sqmm 21.05
6.2
21930
135967.86
45.05 - Heat Shrinkable indoor Type Cable Termination Kit for XLPE Cable3x240 Sqmm 45.05
30
4926
147780
35.04 - Epoxy Terminating Kit (Pothead) suitable
for 1.1 kV, LTUG Cable
266) 35.04) 3.5 x 225/240/300 Sqmm
30
617
18510
35.02 - Epoxy Terminating Kit (Pothead) suitable
for 1.1 kV, LTUG Cable
264) 35.02) 3.5 x 70/95/120 Sqmm
4
401
1604
22.05 - Making and Fixing pot head for HT Cable only Heat shrinkable Straight Through Joint 120 to 240 sqmm 22.05
30
399
11970
22.15 - Heat shrinkable Type Terminations 120 to 240 Sqmm 22.15
30
248
7465.5
22.14 - Heat shrinkable Type Terminations 95 to 120 Sqmm 22.14
4
199
798
66.01 - 608) 66.01) Cable Covering Tile 125x250x40 mm
3000
11
33000
66.12 - Artificial Sand/Manufacture Sand
17
1550
26350
66.19 - 66.19 ) Route & Joint indicating slab with MS Anchor rod
10
140
1400
48.05 - PVC Pipe - 50 mm Dia
90
263
23670
101 - Decorative Median Light Poles: Fabricating, supplying and erection of . Mtrs Long hot dip Galvanized Conical pole with with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2052 for base plate with door opening arrangements, including suitable boards, bakelite sheet for MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for . Mtrs pole in double / single section and single joint welded as per IS 9595/IS 10178AWS having stone bottom 200mm, top 70mm with 3mm thick. The poles should be painted ashetically using good quality auto coat paint. The side pole should be 3mtr height 165mm dia, 3mm thick having 1mtr perforation from 1.5mtr to 2.5 mtr height the poly carbonate pipe housed inside perforstion along with colour chnging LED visible from all sides. The foundation plate should be suitable alluminium head placed t the top including pc cover having 7 watt LED bulb inside. Suitable base plate 4Nos pf m-24 long J bolts along with template and the pole shall be hot dip galvanised dipping with not less than 65micron as per ASTM-A123 and 153 etc. The pole should be as shown in attached. 10 Mtrs Long Galvanized Conical pole Approved rate
20
56300
1126000
2.5.1 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130 1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100V as per IS 694:2010
2.5.1 2C x 1.5 mm2
PWD Elct SR 2023 24 Page No. 6 IItem code 2.5.1
300
55
16695
32.05 - U G Cable
1.1Kv XLPE or Heat resistant PVC insulated PVC Extruded Inner sheath Armoured LT UG cable as per IS 1554 part 1 or IS 7098 Part 1 Armouring strip thickness and resistivity as per IS 3975 16sqmm 4 core 16 Gi strips 4x0.8mm .BESCOM SR 2021 22 BESCOM Part III 11kv materials 203
32.07 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (sl no.215, itm no.32.05)
0.75
146526
109894.8375
21.01 - Laying of cable in Existing Trench orGI pipe orStoneware orRCC Hume pipe using wooden orAluminium Rollers as directed by department staff. 2.5 to 25Sqmm. 21.01
0.75
64388
48291.075
48.04 - PVC Pipe as per IS 2509 Sl No. 387 Item no. 48.04 PVC Pipe 40 mm Dia Vol 6 BESCOM Part III 11 kV Material Sl No. 387 Item no. 48.04
300
118
35595
1.4.1 - Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. 1.4.1) In all kinds of soils Depth upto 1.5 m (0.8x0.8x1.2x20)
15.36
254
3902.976
2.2.1 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage
charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.) 2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (.8x.8x0.01x20)
0.128
6924
886.368
9.3 - Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. Vol 3 - SR for Roads & Bridges 2023-24 (PWD and RDPR) 9.3 (.5*.5*1*20*0.90)
0.45
82961
37332.6975
2.1.1 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. 2.1.1) Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates (.5*.5*1*20)
5
5736
28680.75
11.8.5 - SupplyofLEDStreetlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonatematerial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hrLumenMaintenanceof70,maximumlightintensityshouldbebetween60degreesto70degrees.CCT5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireIK08.PowerFactor0.9withmains,SurgeProtection-Min5KValongwithOvervoltage/Overload,shortcircuit/miss-wiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with singlescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.WSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI75.Luminairemanufacturershouldhavein-housefacilityaccreditedbyNABL/CPRIanyGovernmentcertifiedagencyDesignDevelopmentfacilitycertifiedbyISO90012008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/Bodypart.Warrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturerCree/Nichia/Lumileds/Osram make LED Source. 11.8.5 120W LED streetlight
16
10563
169008
3.9 - Hylum plastic sheet Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches regulators etc. and fixing on existing wood or metal box using N.F. screws.PWD SR 2023-24 Page No.9 Item code 3.9
8192
-
3031.04
5.7.2 - Supplying and fixing of Porcelain fuse channel with cut out on existing wooden orpanel using necessary nuts bolts and washers. 5.7.2 32Amps PWD SR 2023 24 Page No.14 Item code5.7.2
3
253
759.15
5.13.2 - Contactor Switch Supply and fixing of 4pole power contactor with NO orNC contacts on existing wood orpanel board using necessary bolts nuts washers and wiring etc. complete with AC 3 Rating and as per IS 13947. 5.13.2 40 Amps WD SR 2023 24 Page No.16 Item code 5.13.2
1
2370
2370.9
5.18.7 - MCB Switch Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve indicator ON orOFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.17.7 6 32Amps TPN PWD SR 2023-24 Page No.17 Item code 5.18.7
1
1802
1802.85
5.47 - Timer Switch Supplying and fixing Microprocessor based Electronic timer without contactor Din Mounting using necessary bolts nuts and washers etc. . 3 120sec setting. PWD SR 2023-24 Page No.21 Item code 5.47
1
2430
2430.75
5.42.2 - MS Box abricating supplying and mounting MS box made out SWG suitable for floor or wall mounting fully weather proof with provision for better heat dissipation provided with hinged front cover equipped with tamper proof locking arrangements with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.PWD SR 2023-24 Page No.20 Item code 5.42.2 16SWG
32500
-
14625
13.6 - Fixingchargesofposttop/Gate/Gardenfitting/LEDontheexistingCI/GIoranyotherpipeusingrequiredsizeofreducer,wiringusing suitable wires. wires.PWD SR 2023-24 Page No.566 Item code 13.6
20
207
4158
5.18.1 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898.PWD SR 2023-24 Page No.566 Item code 5.18.1
20
435
8715
1.1.1 - Releasing ; Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. 1) 1.1.1) Ordinary Soil
8
1646
13169.6
2.02 - Releasing;45) 2.02) Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth
5
1646
8231
2.01 - Releasing 8 Mtrs RCC pole; 44) 2.01) Erection of RCC/PSCC Pole of 7.5 to 8 Mtr long in a pit of 1.5 Mtr depth
2
1346
2693.2
5.01 - Releaslng 62)5.01) Fixing of 2 Pin cross arm with Insulator and Braces fixing 149) 16.05) Any Dismantling work, 90% of the corresponding erection charges
15
151
2268
6.05 - Releasing of Conductor , 84) 6.05) Rabbit
1.2
4121
4945.32
1.17 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical
means as per drawing and technical specifications, including setting out,
construction of shoring, strutting, barricading, caution lights, bracing, using
sight rails & bonding rods at every 100 mm wherever necessary as directed,
removal of stumps and other deleterious matter, dressing of sides and levelling
the bottom of trench to the extent required , utilising the available excavated
earth locally for the work etc., and all other appurtenances complete in the
following strata. 1.17 Vol1
900
275
247590
102 - Refilling available earth around trenches/pipelines,
cables in layers not exceeding 20 cm in depth,
compacting each deposited layer by ramming after
watering with a lead upto 50 m , and lift upto 1.5
m. Including cost of all labour complete as per
specifications
850
168
142800
28.09 - Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand).28.09
0.7
15550
10885.35
27.01 - Laying and Jointing: Joining with mud mortor completeCovering cable with Tiles 27.01
0.7
4585
3209.745
27.02 - Fixing of Route Joint Indicating Slab 27.02
10
121
1218
13.10 - Releasing & Refixing of Over Head Service Mains (Single Phase/Three Phase) for consumer installation and street lighting and similar work (While executing reconductoring work) 13.10
233
73
17125.5
16.05 - Releaslng 63) 5.02) Fixing of 4 Pin cross arm with Insulator and Braces fixing 149) 16.05) Any Dismantling work, 90 of the corresponding erectioncharges.
15
151
2265