Directorate Of Municipal Administration Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 56,000Document Cost
Refer DocumentsTender Fee
₹ 700
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/OW/WORK_INDENT33835Tender No
DMA/2024-25/OW/WORK_INDENT33835Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
code04 - PV Module: 75 WP under STC Battery: Minimum 12.8V, 30 AH capacity Lithium Ferro Phosophate Battery
5
20000
100000
... More
code05 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m PWD SR 2023-24 Item No 1.16.2 Volume-I
4.05
641
2598.8445
... More
code06 - Providiing and constructing unreinforced plain cement concrete pavement, thickness as per design, vr a prepared sub base, with 43 grade cement or any other type as per clause 1501.2.2 M20 (Grade) coarse and fine aggregates conforming to IS 383, maximum size of coarse aggregate not exceeding 25mm mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side form work (stel channel laying and fixing of 125 micron thick polytheye film, wedges, steel plates including leelling the form work a per drawing spreading the concrete with shovels, rakes compacted using needle, screed and plate ibrators and finished in continuous operatin including construction joints, primer, sealant, curing of concrete slabs for 14 days and water finishing to lines and grade as per drawing and technical specifications clause 1501 with al lead lifts loading and unloading harges cost and conveyance of all materials, labour equipments etc complete PWD SR 2023-24 It. No. 16.28 Pg No.149
8.895
6956
61879.1349
... More
code07 - Additionalities for form work centering and scaffolding 5% on the finished rae of concrete per cum PWD UNI SR Appendix- 1 Pg. No. 115 Sl. No.2
8.895
322
2865.7911
... More
code08 - 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. SR 2023-24
0.804
92140
74081.13084
... More
code09 - Fabrication, Supplying and Erection Testing and commissioning of12 m/12.5 m long polygon high mast with single /mutiple telescopic sections having (minimum overlap distance of 1.5 times of top section) thickness sa per BSEN 10025 grade S 355JO /ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/sec as per IS 875 part 3( As per GA Drawing ).Base plate as per IS 2062/ASTM A572-50.The mast shall bi galvanized in single hot dip as per BSEN ISO 1461/ASTM A123 with an average 70microns as per IS 2629, and welded as per BS 5135 single L seam joint.The mast shall have 2 way head frame with die cast LM-6 pulleys, stainless steel axle,Phoshorus Bronze bearing bush press -fitted with separte guides for 2 runs of 5mm dis,stainless steelwire rope of AISI 304 grade 7/19-core,(Factor of safety as per TR no-7).2.5 sqmm EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement .The mast shall have power tool operting on 230/415 V,50Hz 1/3 phases reversible geared motor .The mast shall have lantern of 2 segments ,suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing .The mast shall be supplied with 3mm thick template,lighting arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin lamps fitting with wiring complete.(excludoing foundation )as per technical data 12 m/12.5 m - Top 100 mm and Bottom 310 mm dia
3
134930
404790
... More
code10 - Supply of LED Floodlight 150W luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains,Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatiblefor pole mauling with outer dia of 40mm to 50mm. UniversalVoltage driver to operate wide voltage range from 100 V to 270V50/60Hz applicatio. Compliance to IS 10322/ IEC 60598,LM 79 & LM 80 Adherence with RoHS. UL approvedMCPCB. Top access street light with single screw to ensureease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & evelopment facility certified by ISO 9001:2008. Housing with supplier word mark / name shall beEngraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ PWD (Ele.) SSR Page 37 item No.11.9.4
28
15927
445981.76
... More
code11 - Fixing halogen/metal halide floodlight fitting over existing pole /wall celling including clamps bolts and nuts and wiring using suitable capacity wires complete.
24
166
4004.64
... More
code12 - Supplying & fixing of Porcelain fuse channel with cut on existing wooden /panel using necessary nuts, bolts and wasgers etc., complete.C) 63Amps
15
413
6195.45
... More
code13 - Supplying & fixing and wiring earth electrode for grounding conduits I.C cutouts and other equipments on the meterboard using 40mm dia 2.9mm thick GI pipe 2.5mtr long buried in a pit.The pit should be fitted with equal proportion of salt and charocal 150mm around the pipe to complete depth.The connection from pipe to the conduit etc, is to be established through IG wire of size as per IS specificationm7.3.3 of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc..,the pipe shall have 16 through holes of 12mm dia
4
4383
17534.72
... More
code14 - Supplying & running GI/copper conductor for grounding connections, Using necessary fixing materials as required25x3 mm Copper strip
90
587
52839
... More
code15 - Supplying of 1.1Kv LT UG cable having aluminium conductor PVC insulated, sheated,galvanized steel strip (Except 2CX10Sqmm wire aroured) confiriming to IS -3975:1990(No of strip indicated in GTP N& extruded PVC outer sheated armoured cable with spcified IS 1554 Part 1:1988 & confirming to GTP of Group A 4 core 10 sqmm
85
133
11381.5
... More
code16 - Labour charges for laying of 1.1 KV class UG cable in existing trench Gipipe /stoneware pipe /on pole as required I) existing trench/duct.A) 6sqmm to 16 sqmm
110
12
1345.3
... More
code17 - Digging of trenche of 0.6m deep x 0.50 Mtr wide refilling the trench to the required ground level and consolidating etc…,complete
105
78
8219.4
... More
code18 - HDPE pipes 90MM dia
105
139
14600.25
... More
code19 - Supplying fixing and wiring 3phase Digital ammetrt voltmeter
3
732
2196.99
... More
code20 - Supplying fixing L.T cast iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen /insulating compound complete with terminals, clamps,bolts,nuts,and washersetc...
3
360
1081.5
... More
code21 - Fabricating supplying and mounting MS box made out 14 SWG suitable for floor /wall mounting ,fully weather proof with provision for better heat dissipation ,provided with hinged front cover ,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and should be finished with 2 coats of red oxide primer paint and finally finished with apporved colour enameled metal paint etc... complete
74200
-
32648
... More
code22 - Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting.
3
2384
7153.35
... More
code23 - Supplying and fixing and wiring Eart leatage miniature circuit breaker (ELMAB.,) 240.450V up to 300me sensitivity on existing wood panel board. 32-40 Amps 4 pole
3
5415
16247.22
... More
code24 - Supplying and fixing Regular MCB distribution Boards on wall /aood Board / flush mounting using require clamps bolts nuts with provision for fixing suitable type capacity MCB SINGLE PHASE/ 3 phase /single dooe with powder coated painting Made out of 14 SWG MS enslouse..
3
1918
5756.67
... More
code25 - Supplying and fixing angle iron frame fabricated out of S angle iron and M.S flat with bolt washer etc and painted with 2 coat of red oxide and then two coats of apporved paint 50X50X6mm
33
406
13426.05
... More
code26 - EARTH WORK- 1.1 Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces,
disposing off or levelling the excavated earth or sorting & stacking
the selected earth for reuse in a radius of 50 m and lift upto 1.5 m
including cost of labour, tools, usage & other appurtenances required to complete the work. SR2022-23
0.864
93
80.98272
... More
code27 - Providing and laying in position plain cement concrete for levelling
course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1
Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse
aggregates 2.1.2 SR2022-23
0.144
5833
840.08448
... More
code28 - 2.3 Providing and laying in Reinforced cement concrete for all Basement
& surface level works, return walls, retaining walls, sunken floors
etc. The granite/trap/basalt crushed graded coarse aggregates and
fine aggregates as per relevant IS Codes machine mixed with super
plasticisers, laid in layers, well compacted using needle vibrators,
providing weep holes wherever necesary, including all lead & lifts, cost
of all materials of quality, labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per
technical specifications. (The cost of steel reinforcement & formwork
to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates.
Appendix I Additionalities for Formwork, Centering & Scaffolding.Foundation upto Plinth- a. Isolated- 8%
0.576
7208
4152.0096
... More
code29 - 1.6Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.
10
498
4985.2
... More
code30 - Supply and laying Double walled corrugated (DWC) HDPE pipe including all necessary conneting sockets/couplings tees/Bends/End-caps of same materials in existing trench as per IS 14930 part-II suitable for drawing underground cables 40mm OD/32MM ID (Page N
10
100
1009.4
... More
code31 - 32. 215 32.051.1 kV, XLPE or Heat resistant PVCinsulated, PVC exutruted Inner SeathArmoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring stripthickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)
0.01
146097
1460.9726
... More
code32 - 31. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers asdirected by the departmental staff. LT Cable 31.05 2.5 to 25 Sqmm
0.01
21512
215.1258
... More
code33 - 286 34.21 Installation of Pre-Insulated Lug - CPTAU for 16 Sqmm
4
164
659.2
... More
code34 - 127 14.03Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grademulti strand copper with low conductor resistance 4 Sqmm single core wire inopen are concealed system of wiring with specified IS-694-1990 and conforminto GTP of group A
5.3658
50
270.811926
... More
code35 - 2.5- 2.5.8 3C x 2.5 mm2Supplying and drawing Flexible Multicore Cable manufacturedwith electrolytic grade flexible copper with low conductorconfirming to IS 8130-1984 and (Virgin) PVC insulationsheathed suitable for working voltage upto 1100V as per IS-694:2010
4
116
465.56
... More
code36 - 5.17 - 5.17.2 40 A SPSupplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.
1
816
816.79
... More
code37 - 5.17- 5.17.1 6-32 A SPSupplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.
4
427
1709.8
... More
code38 - 5.19Supplying, fixing and wiring Residual current circuit breaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 5.19.5 63 A 2 pole
1
5415
5415.74
... More
code39 - 5.7. Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 5.7.3 63 A.
1
413
413.03
... More
code40 - 5.47Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nutsand washers etc.,.) 3-120sec setting.
1
2384
2384.45
... More
code41 - 5.13- 5.13.3 60 to 70 ASupply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessarybolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.
1
6302
6302.57
... More
code42 - 5.41- 5.41.1 40 x 40 x 6 mmSupplying and fixing angle iron frame work fabricated out ofM.S. angle iron.. and M.S. Flat......with bolts, washers etc., andpainted with 2 coats of red oxide and then two coats ofapproved paint.
3.9
314
1225.185
... More
code43 - 4.3 Electrical SR2022-23
Supply and erection of 14 Feet Height Street Light Pole 14 Feet
Height Street Light Pole on suitable cement concrete foundation
with 2.5 Feet height dia 95 mm cast iron decorative round
pedestal as per design weighing not less than 37Kgs, the
pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75
mm outer dia and 7 feet height top piece outer dia of 65 mm
fixed by measure of threading/welding/coupling complete.
(excluding foundation).
3.8
21218
80628.4
... More
code44 - LED Streetlight 70W Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.
Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility
accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned
4
6171
24687.04
... More
code45 - 13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting overexisting pole / wall ceiling including clA, bolts, nuts and wiringusing suitable capacity wires.
4
166
667.44
... More
code46 - 5.20Supplying, fixing and wiring Earth Leakage Miniature CircuitBreaker (ELMCB) 240/450V upto 300mA sensitivity on existingwood/panel board. 5.20.1 16-25 A 2 pole
4
4405
17621.24
... More
code47 - 5.40- 5.40.1 100 A 4 x 30 x 6 mm Aluminium StripsSupplying ......... A rated 3phase with neutral bus bar usingrequired capacity electrolytic aluminium strips covered withheat shrinkable coloured PVC sleeve, mounted onphenolic/FRP/DMC insulator which are mounted on powdercoated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination ofincoming and outgoing cables as per IS specification withnecessary bolts, nuts and washers etc., complete
3.9
2538
9901.905
... More
code48 - 442 54.04 Rod type of earthing using 40 mm Dia, 3 Mtr long MS
rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified
1
2237
2237.16