Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Electrical and Electronics
Electrical Works
Opening Date7 Nov 2024
Closing Date22 Nov 2024
Tender Amount₹ 2,10,98,499.99 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code19 - Fabrication, Supplying, Erection, Testing and Commissioning of . ms long Polygon high mast with Single/ Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hotdip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housedinside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data12 m/12.5 m - Top 100 mm and Bottom 310 mm dia

4

137550

550200

... More
code20 - Supplying and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1500 mm Standard 40/50 mm dia

32

2205

70560

... More
code21 - upply of LED streetlight luminaire with pressure die-cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti-glare clear diffuser with injection-molded polycarbonate material, delivering superior light output Rated life Burning Hrs. 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees and 70 degrees. CCT 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, surge protection (min 5KV), along with overvoltage overload and short circuitormiss-wiring protection. Compatible for pole mounting with outer diameter of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL-approved MCPCB. Top-access street light with single screw to ensure ease of maintenance at the sight site location with minimal minimal tools. LED Light fixture with W system System Power consumption. LED Efficiency: 1301 morw, nominal CRI 75. A luminaire manufacturer should have an in-house facility accredited by NABLorCPRI and any government-certified agency a design and development facility certified by ISO 9001:2008. Housings with a supplier's wordmark or name shall be engraved or embossed on the die-cast housing or body part. Warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by the LED manufacturer, and Cree, Nichia, Lum LED, or Osram make LED sources. LED Streetlight 70W

60

6291

377496

... More
code22 - Supply of LED floodlight luminaire with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with injection-molded molded polycarbonate or clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT greater tahn 5500K, IP 66 optical and electrical compartment, and impact resistance of complete luminaire greater tahn IK08. Power Factor greater tahn0.9 with mains, Surge Protection: Min 5KV along with overvoltage or overload, short circuitor miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50or60Hz application. Compliance to IS 10322or IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiencygreater tahn 1301morw, nominal CRI greater tahn75. Luminaire manufacturer should have in- house facility accredited by NABL or CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark or name shall be Engraved or Embossing on the die cast housing or Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree or Nichiaor Lumi leds or Osram make LED source. LED Floodlight 120W

32

11294

361435.2

... More
code23 - GI pipe 100 mm (nominal bore), medium class (including accessories)

50

1417

70875

... More
code24 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateorclear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, CCT greater tahn 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire greater tahn IK08. Power Factor greater tahn0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50or60Hz application. Compliance to IS 10322or IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiencygreater tahn 1301morw, nominal CRI greater tahn75. Luminaire manufacturer should have in- house facility accredited by NABL or CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark or name shall be Engraved or Embossing on the die cast housing or Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source . LED Floodlight 70W

60

7106

426384

... More
code25 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and(Virgin)PVCinsulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 2C x 1.5 mm2

500

55

27825

... More
code26 - Fixing halogen/metal halide/SVL/IL/LED floodlight fitting over existing pole/wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.

152

170

25855.2

... More
code01 - Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595 IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.7 m - Top 70 mm and Bottom 130 mm dia

60

14175

850500

... More
code02 - Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable form out door luminaries and mounted on Octagonal pole using necessarym bolts, nuts etc., complete.Single Arm Bracket with 1000 mm Standard 40/50 mm dia

60

1785

107100

... More
code03 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'Typecurve, indicatorON/OFF, energycross-3 with Short circuit breaking capacity of10K and complete wiring as required confirming to IEC60898. 6-32 A SP

60

435

26145

... More
code04 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)

6

148934

893604.6

... More
code05 - Compression type Aluminium Tubular in Line Connector for Aluminum Conductor16 Sqmm

250

4

1000

... More
code06 - Optical Fibre Cable (OFC) and its Accessories HDPE/PLB Pipe 40/33 mm

5.8

65452

379626.24

... More
code07 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm

6

21930

131581.8

... More
code08 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 50, 4 Core, (17 GI Strips - 4 x 0.8 mm)

2

217553

435107.4

... More
code09 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm

2

32695

65391.9

... More
code10 - Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 50 Sqmm

30

7

220.5

... More
code11 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm)

2

582387

1164775.5

... More
code12 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable

2

32695

65391.9

... More
code13 - Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 150 Sqmm

20

27

546

... More
code14 - Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft r9ock without blasting upto 1.5 m depth(L=11000 B=.75 D=.75)

5625

313

1765968.75

... More
code15 - Refilling available earth around trenches/pipe lines, cables in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications

5500

168

924000

... More
code16 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG

1250000

-

650000

... More
code17 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips

10

4667

46672.5

... More
code18 - Supplying.........Arated3phasewithneutralbusbarusingrequiredcapacityelectrolyticaluminiumstripscoveredwithheatshrinkablecolouredPVCsleeve,mountedonphenolic/FRP/DMCinsulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips

10

2588

25882.5

... More
code19 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heatshrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips

20

2588

51765

... More
code20 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron and M.S.Flat......with bolts,washer setc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 100 x 50 x 6 mm C channel

30

793

23814

... More
code21 - Supplying and fixing angle iron frame work fabricated out of M.S.angleiron..and M.S.Flat......with bolts,washer setc.,and painted with 2 coats of red oxide and then two coats of approved paint 40 x 40 x 6 mm

20

320

6405

... More
code22 - Supplying 4mm thick plastic sheet with necessary nitches for fixings witches,regulator setc,and fixing on existing wooden or metal box using N.F. screws.

250000

-

107500

... More
code23 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 .(Icu=100 lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism 250 A 25 kA

4

22460

89842.2

... More
code24 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over theexisting wood/panel board using necessary screws, bolts, nuts,necessary phase separators, handle and wiring complete. Protection ofOverload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 .(Icu=100 lcs). In 4P MCCB, all Poles should have protection forShort-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism 320-400 A 50 kA

4

31616

126466.2

... More
code25 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over theexisting wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100 lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the polessimultaneously and they shall have a single mechanism100 A 25 kA FOUR Pole

15

8911

133670.25

... More
code26 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Typecurve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN

25

3242

81060

... More
code27 - SupplyingofmultifunctiondigitalmeterwiththreelinebacklightLCDtypedisplayforvoltage,Current,frequency,Power,powerfactor,kVA,kWH,kVARsuitablefor3phase,4wireLTnetworkwithIP54degreeofprotectionandcompletelywiredasrequiredwithcommunication Port and Class 0.5s accuracy

15

9780

146711.25

... More
code28 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

50

540

27037.5

... More
code29 - Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3phase, 400/440Vgrade,for power factor improvement of rotating machineries like induction motor.

500

504

252000

... More
code30 - Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs

3

22722

68166

... More
code31 - Supply and fixing of 3-pole Capacitor switching contactor with NO/NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage, 50HZ frequency and as per IS 60947-4-1.-1.50KVAR

12

15820

189844.2

... More
code32 - Supply and fixing of Multifunctional three phase monitoring relays suitable to monitor three phase mains. It monitors all phase parameters such as over/undervoltage, phase unbalance, phase failure as well as an interrupted neutral. The corresponding threshold values are adjustable. Phase sequence monitoring as well as an ON or OFF tripping delay are selectable. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). voltage rating 180V - 280V AC

3

18128

54384.75

... More
code33 - Supplying, fixing and wiring 50/5to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.

36

590

21243.6

... More
code34 - Supplying,fixing and wiring1000/5Ato1600/5A15VABurdenclass 1 Current Transformer

12

882

10584

... More
code35 - Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. 100 KVA/ 80 kw

2

946003

1892007.6

... More
code36 - Supplying of on load change overs witches 4poles, AC-23A Duty, 415V, 50Hz,AC Supply.With all accessories.(SM Enclosure Sheet Metal Execution)250 A

2

22968

45937.5

... More
code37 - Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 500 kVA, Aluminium Wdg, Star 2 (5 Star) CABLE ENTRY TYPE

1

959467

959467.95

... More
code38 - LT Distribution Box for 100/250 kVA DTC with MCCB's (SMC)

1

25649

25649.4

... More
code39 - LT Protection Kit(Dwg no. BESCOM/GM/QS&S/10 Dtd 24.11.2018)

1

2124

2124.15

... More
code40 - 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)

0.15

934149

140122.395

... More
code41 - 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 no of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification(Dwg no. BESCOM/GM/QS&S/-- Dtd 24.11.2018)

1

255645

255645.6

... More
code42 - Load Break Switch

1

76900

76900.95

... More
code43 - Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm

4

4270

17081.4

... More
code44 - Heat Shrinkable Straight Through Jointing Kit for XLPE Cable with Copper Lug & Al Ferrule 3x95 Sqmm

4

7676

30706.2

... More
code45 - LT 3 Phase, 4 Wire, CT Operated DLMS Complaint ETV Meter-5A, class 0.5s Accuracy (Used for 25 HP/18KW & Above Installations, DTC Metering)

1

3565

3565.8

... More
code46 - For Distribution Transformer Centre (DTC) MS Box for housing the ETV Meter 3 Phase 4 Wire 5 Amps, with associated LT CT 0.5 Accuracy Class, ring type, with wiring Clamps, B&N and all other accessories required. (EXCLUDING ETV METER) With CT Ratio 800/5 for 500 kVA DTC

1

6416

6416.55

... More
code47 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 Sqmm

0.14

64388

9014.334

... More
code48 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)

0.2

905799

181159.86

... More
code49 - Compression type Aluminium Tubular in Line Connector for Aluminum Conductor240 Sqmm

20

55

1113

... More
code50 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 to 240 Sqmm

0.14

33891

4744.866

... More
code51 - GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg Each Good Quality Salt for grounding purposes packed in 50 Kg gunny bag

90

1815

163390.5

... More
code52 - Digging of Pit for providing GI Pipe type Earthing

90

796

71725.5

... More
code53 - Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

3.468

6948

24098.7852

... More
code54 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

10.4

253

2631.72

... More
code55 - 11.58 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. (Made of G.I. wire of dia 4 mm)

18

843

15176.7

... More
code56 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.

250

118

29662.5

... More
code57 - GOS as per IS-9921, IS-1977 11 kV, 400 Amps Double Break GOS(Dwg no.BESCOM/GM/QS&S/22 Dtd 24.11.2018)

2

22323

44646

... More
code58 - Fixing of GOS including wiring (11 kV Double Break 400 Amps)

2

1274

2549.4

... More
code59 - Erection of 300 - 500 kVA Transformer

1

3239

3239.25

... More
code60 - Erection of HT metering Cubicle on Platform.

1

1936

1936.2

... More
code61 - Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter & wiring for DTC 300/500 kVA TC

1

2043

2043.3

... More
code62 - Fixing of 11 kV GOS Single Break or Double Break including wiring on old existing Structure (were only fixing of GOS work is involved)

1

2533

2533.65

... More
code63 - Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring

3

248

746.55

... More
code64 - 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification 3 noS

1

6168

6168.75

... More
code65 - DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - GI

1

9306

9306.15

... More
code66 - 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR(Dwg no. BESCOM/GM/QS&S/26 Dtd 24.10.2007)

3

966

2898

... More
code67 - Fixing of 3 nos Lightning Arrestor including wiring 3 noS

1

124

124.95

... More
code68 - Insulation Tester (Megger) 500 V rating

2

12776

25552.8

... More
code69 - Multimeter electronic type

2

8390

16781.1

... More
code70 - 1000 A AC Clamp Meter (DCM 39 A)

2

12776

25552.8

... More
code71 - Arc welding machine 9/10 Kva

2

29285

58571.1

... More
code72 - Protective Goggle

4

945

3780

... More
code73 - Rubber shoes knee height

8

2244

17959.2

... More
code74 - Hand drilling machine

2

22441

44883.3

... More
code75 - Safety helmet with rachet

8

289

2318.4

... More
code76 - Rain coat with duck back

5

1180

5901

... More
code77 - Gum Boots

6

2738

16430.4

... More
code78 - Hydraulic Bolt Cutter / Wire Cutter upto Drake ACSR conductor with bits for cuttings

1

50687

50687.7

... More
code79 - Allen keys

3

501

1505.7

... More
code80 - Hammer 8 Lbs

2

521

1043.7

... More
code81 - Hammer 2 Lbs

2

261

522.9

... More
code82 - Rechargeable 5 W LED Hand Torch

4

1342

5371.8

... More
code83 - Pipe wrench : 24 inches size

2

1312

2625

... More
code84 - Ring spanners : 12 nos. per set

2

924

1848

... More
code85 - Tube Spanners : 12 nos. per set

2

1506

3013.5

... More
code86 - Rubber hand gloves 15 kV tested

2

307

615.3

... More
code87 - Hack saw frames +B185

2

381

762.3

... More
code88 - Insulated cutting pliers : 12 inches size

2

412

825.3

... More
code89 - Box spanners : 12 nos. per set

2

4690

9380.7

... More
code90 - ABC Powder Type Fire Extinguisher 9 Litre with necessary mounting stand)

5

7775

38876.25

... More
code91 - ABC Powder Type Fire Extinguisher 6Litre with necessary mounting stand)

5

5221

26108.25

... More
code92 - Sand Type G.I. Buckets 9 Litre

6

633

3798.9

... More
code93 - Steel stands

2

2480

4960.2

... More
code94 - Supplying, erecting, testing & commissioning of OFF-LINE UPS system suitable for operation on 230V,50Hz,A/C supply,with all accessories complete and Excluding batteries and wiring complete. 2 kVA OFF LINE UPS

1

22357

22357.65

... More
code95 - Supplying, erecting, testing & commissioning of OFF-LINE UPS system suitable for operation on 230V,50Hz,A/Csupply,withallaccessories complete and Excluding batteries and wiring complete. 1kVA OFF LINE UPS

1

15841

15841.35

... More
code96 - Supplying, installation,testing & commissioning of12VDC,AH batteries in polypropylene container for U.P.S.Sealed maintenance free batteries.. 100 AH capacity

3

13051

39154.5

... More
code97 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box,elbows,screwsatan interval of 300 mm as required. 20mm

550

29

15950

... More
code98 - Supplying And Fixing"S"Hook made out of 14mmdia M.S.Rod.

10

54

546

... More
code99 - Supplying and wiring adopting loop system inexisting PVC Conduit/casing capping casing capping using2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLS multistrand PVC insulated copper wire(confirmingtoIS-694:and latest amend ments) without controls witch shall be fixed on the existing plastic sheet/gangbox,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Short point upto 3Mtr from tapping point to out let via switch box

20

282

5649

... More
code100 - Medium point above 3Mtr upto 6Mtr from tapping point to outletvia switch box

20

397

7959

... More
code101 - Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box

10

582

5827.5

... More
code102 - Wiring for lighting/power circuitusing one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring wit hspecified IS-694:2010 2.5 mm2

800

44

35280

... More
code103 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100Vgrade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4mm2

600

66

39690

... More
code104 - Supplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends,junction boxes,adhesive pasteetc,and fixing using inverted wood plugs in case of RCC ceiling and RCCwall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick

2000

72

144900

... More
code105 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and(Virgin)PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 4 mm2

2100

180

379260

... More
code106 - Supplying and fixing surface/ flush mounting unbreakable PVC modular boxs Suitable for mounting modulars witch plates with due groove cutting in Brick/C.Cwall,including necessary raw lplugs,Machine/NF screws etc., complete. 4-5 Way

40

143

5754

... More
code107 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nutsetc.,complete on the existing metal/PVC box. 4 Module

12

183

2205

... More
code108 - Supplying and fixing superior quality modulars witch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nutsetc.,complete on the existing metal/PVC box 8 Module

20

298

5964

... More
code109 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nutse tc.,completeontheexistingmetal/PVC box 10-12 Module

8

361

2889.6

... More
code110 - Supplying and fixing of modular switch& connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

150

107

16065

... More
code111 - Supplying and fixing of modulars witch & connected accessories one xisting modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module

15

374

5622.75

... More
code112 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch

5

342

1711.5

... More
code113 - Supplying and fixing of modular switch &connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket

80

247

19824

... More
code114 - Supplying capacitor type ceiling fan complete with down rod blades,shackle,can opiesetc,for operation on 230V,50cycles.Single phase A C supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model

10

3133

31332

... More
code115 - Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing'S''hook with fan regulator to the existing board to get her with supplying and fixing 5A.ceilingrose,necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

10

179

1795.5

... More
code116 - Fixing all types and all capacities offluorescent/falseceiling/spotlight/CFL/LED fittings indoor on the wall/ceiling/rafters/girdersusing23/0.0076"twin twisted PVC insulated wires,required nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders

50

128

6405

... More
code117 - Supplying & fixing retrofit type-PL-LED Lamp W LED linear source with CCT6500 degree K, CRI greater than 70. efficacy greater than 80 lumen per W, life greater than 25000 burning hours, and CETOIS10322 or IEC60598,LM79&LM80.The LEDs are driven by an HF electronic driver integrated in the system, with a PF gain of 0.95; power loss should be less than the lamp wage. short circuit and open circuit protection to be integrated in the circuit, THD less than 20, life as per LM79.The operating input voltage should be between 130 and 275V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18-20w

50

737

36855

... More
code118 - Supplying exhaust fan of 1440 RPM of 300mm (12) size with bracket blade complete for light duty suitable to operate on 230V 50Hz, AC Supply.

5

1566

7833

... More
code119 - Supplying & Fixing of 230 V 20/40 W FluorescentLamp holder

20

34

693

... More
code120 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets,with bolts and nuts and 5A,ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.

5

742

3711.75

... More
code121 - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 50x40 Head 22M, Discharge 186 LPM

8

17842

142741.2

... More
code122 - Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. Upto 7.5 HP centrifugal pump

8

9975

79800

... More
code123 - Supplying and drawing 3core flat PVC sheathed submersible pump cable manufactured with electrolytic grad copper with flexible copper with low resistance conductor confirming to 13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 mm2

200

176

35280



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.