Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 1,30,000Document Cost
Refer DocumentsTender Fee
₹ 1,610
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/BD/WORK_INDENT22476Bid Award Id
ViewTender No
DMA/2024-25/BD/WORK_INDENT22476Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
code04 - KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) As per reccomondation of Technical Working Group Rates for Formwork shall be added on percentage basis to finished item rate
8.41
13228
111249.7507
... More
code05 - KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)
5.94
11439
67947.7194
... More
code06 - KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)
5.31
108726
577335.2193
... More
code07 - KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)
28.22
7765
219133.6618
... More
code08 - KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)
322.51
559
180383.0681
... More
code09 - KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)
145.44
1496
217600.056
... More
code10 - KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)
303.84
358
108938.7936
... More
code11 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)
19518
137
2680602.12
... More
code12 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)
951.97
690
657182.9698
... More
code13 - KSRB 8-8.51 : Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)
303.84
121
36928.7136
... More
code14 - KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)
145.44
88
12903.4368
... More
code15 - KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)
145.44
88
12903.4368
... More
code16 - KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)
14.76
3200
47234.0664
... More
code17 - KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)
2
30003
60006.72
... More
code18 - KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)
300
549
164808
... More
code19 - Supplying heavy gauge PVC conduit pipe 32 dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws..(Item No. 1.1.3, Page No.4,PWD Electrical SR Vol-06)
330
128
42513.9
... More
code20 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 .(Item No. 2.5.1, Page No.6,PWD Electrical SR Vol-06)3C X 4 mm2
325
209
67938
... More
code21 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (Item No. 3.4.5, Page No.8,PWD Electrical SR Vol-06)
8
317
2537.68
... More
code22 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (Item No. 3.5.5, Page No.8,PWD Electrical SR Vol-06)
8
345
2761.36
... More
code23 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.1, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 16A
5
471
2356.4
... More
code24 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.2, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 32A
4
666
2664.52
... More
code25 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.3, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 16A
4
549
2198.04
... More
code26 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.4, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 32A
4
741
2964.84
... More
code27 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.5, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 16A
4
645
2581.32
... More
code28 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.6, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 32A
5
810
4053.55
... More
code29 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.7, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 16A
5
770
3851.45
... More
code30 - Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.8, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 32A
5
1006
5030.6
... More
code31 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.1, Page No.10,PWD Electrical SR Vol-06) 6A SP Switch
54
66
3609.36
... More
code32 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.3, Page No.10,PWD Electrical SR Vol-06) 6A Three Way 5 Pin Socket
9
85
765.63
... More
code33 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.10, Page No.10,PWD Electrical SR Vol-06) 16A SP Switch
9
159
1432.89
... More
code34 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.12, Page No.10,PWD Electrical SR Vol-06) 16A Three Way 5 Pin Socket
9
139
1257.93
... More
code35 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.14, Page No.10,PWD Electrical SR Vol-06) 32A Bakelite DP
9
281
2537.73
... More
code36 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.15, Page No.10,PWD Electrical SR Vol-06) 16/6A combined plug and socket with control switch
9
264
2384.55
... More
code37 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.,6-32 A SP(Item No. 5.18.1, Page No.17,PWD Electrical SR Vol-06)
9
504
4539.51
... More
code38 - Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws,(Item No. 3.8, Page No.9,PWD Electrical SR Vol-06)
5400
-
2646
... More
code39 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 50 kA (Item No. 5.15.8, Page No.16,PWD Electrical SR Vol-06)
1
30505
30505.36
... More
code40 - Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 4 Way (Item No. 5.17.1, Page No.16,PWD Electrical SR Vol-06)
1
12553
12553.86
... More
code41 - Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA 16 - 32 A SP (Item No. 5.46.1, Page No.21,PWD Electrical SR Vol-06)
9
255
2297.07
... More
code42 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 Lumen Maintenance of 7, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltageOverload, short circuit miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V application. Compliance to IS 10322 IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with System Power consumption. LED Efficiency 130, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL CPRI any Government certified agency Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & CreeNichi LumiledsOsram make
9
8225
74032.38
... More
code43 - 1.1 kV Class Armoured Aluminium Cable with glands/lugs/ferrules :4C x 70 Sq mm (Item No. 14.3, Page No.542,PWD Electrical SR Vol-06)
68
658
44794.32
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements