Directorate Of Municipal Administration Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 6,150Document Cost
Refer DocumentsTender Fee
₹ 500
Summary
Providing And Errection Of Mini Mast Light Near Vishwaradhya Math Of Shakapur Village
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/EL/WORK_INDENT24632Bid Award Id
ViewTender No
DMA/2024-25/EL/WORK_INDENT24632Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
code04 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteortraporbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR 2023-24 item no.2.4.2, Pg.No 17)
2.53
6639
16797.0495
code05 - Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingorwelding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(PWD CSR 2023-24 vol1 item no. 2.11a, Pg.No 18)
0.18
93929
16907.373
code06 - Supply of 200W LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateorclear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT more than 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire more than IK08. Power Factor more than0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322or IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 200W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than75. Luminaire manufacturer should have inhouse facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaorLumiledsorOsram make LED Source.
6
18581
111486
code07 - wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper conductor single core wire in open or concealed system of wiring as per IS-694:1990 and confirming to GTP 1.5 sqmm PWD SR (2023-24) Page no 5 item no 2.3.2
175
26
4550
code08 - Fixing halogenormetal halideorSVLorILorLED floodlight fitting over exising poleorwall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires PWD SR vOL-6 (2023-24) Page no 56 item no 13.5
6
162
972
code09 - Supplying and fixing angle iron frame work fabricated out of MS angle iron 50X50X6mm and MS flat with bolt washer etc., and painted with 2 coats of redoxide and then two coats of approved paint. PWD SR VOL-6 (2023-24) Page no 56 item no 5.41.2
6
395
2370
code10 - Fabricating Supplying and mounting MS box made out 16 SWG suitable for floororwall mounting fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locing arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint, etc complete., PWD SR VOL-6 (2023-24) Page no 20, Item.No 5.42.2
6000
-
2580
code11 - Supplying and fixing miniature circuit breaker on existing MCB distributing boards using necessary fixing materials and ‘C’ type Curve, indicator ONorOFF, energy cross-3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 a) 6-32 Amps SP PWD SR VOL-6 (2023-24) Page No. 17, Item No 5.18.1
6
415
2490
code12 - Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (Except 2CX10 sqmm wire armoured) confirming to IS 3975;1990 (No of strips indicated in GTP) and extruded PVC outer sheated armoured cable with specified IS-1554 part-1;1988 and confirming to GTP of GROUP-A 4 core 10sqmm PWD SR (2019-20) P.No. 40, Item No 6.4.2
30
130
3900
code13 - Supplying and fixing of class A(medium duty) GI Pipe of wall thickness not less than 3.25mm on PoleorWallorDrain crossing with necessary clamping arrangement for UG cable of 1.1KV a)50mm PWD SR (2019-20) Page. No. 42, Item No 6.9.2
5
380
1900
code14 - Supplying and fixing of porcelain fuse channel with cut out on existing woodenorpanel using necessary nuts, bolts and washers. 32 Amps PWD SR VOL-6 (2023-24) Page.No.14,Item.No.5.7.2
2
241
482
code15 - Supplying and fixing of 4 pole power contractor with NOorNC contacts on existing woodorpanel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS -13947 25Amps PWDSR(2019-20) Page.No.26, Item.No.5.13.1
1
1263
1263
code16 - Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. PWD SR (2023-24) Page.No. 21,I.No.5.48
1
4843
4843
code17 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil PWD SR (2023-24) Page.No. 63,I.No.29.02
7.5
260
1950
code18 - Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr 29.07
7.5
58
435
code19 - Labour charges for laying of 1.1KV class UG cable in existing trench GI pipeorstone ware pipeoron pole as required. In existing trenchorduct 6 Sqmm to 16 Sqmm PWD SR (2023-24) Page no 52 item no 21.05
0.03
20886
626.58
code20 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20 Amps single phase Class-1 Accuracy with Temper Proof Energy Meter. PWD SR VOL-6(2023-24) Page no 19 item no5.30)
1
1380
1380
code21 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutout and other equipments on the meter board using 40 mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit…The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122mm dia. PWD SR VOL-6(2023-24) Page. No.54, Item .No. 12.56
1
3510
3510
code22 - Supplying heavy guage PVC conduit pipe 32mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, juntion boxes adhesive paste etc.. A nd fixing using inverted hood plugs in case of RCC ceiling and RCC wallor stone structure or rawl plugs in case of brick walls and cemement plastering the damaged portion using heavy guage saddles at an interval of 700mm using NF screws.
PWD SR (2019-20) Page no 2 item no 1.1.3
10
81
810
Evaluation Notes How It Works ?