Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Civil And Construction
Pipe Line Project
Water Storage And Supply
Opening Date3 Sep 2024
Closing Date21 Sep 2024
Tender Amount₹ 8,00,000.01 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,) collars, cap etc., complete (CSR Water Supply & Sewerage Works Vol-5, P No-139, I No-12.1.3)

50

507

25389.5

... More
code05 - Supply of ISI mark 175mm nominal bore, plain and Steel Casing Pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (CSR Water Supply & Sewerage Works Vol-5, P No-143, I No-12.32)

18

1990

35837.82

... More
code06 - Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. (CSR Water Supply & Sewerage Works Vol-5, P No-143, I No-12.34)

1

168

168.92

... More
code07 - Providing, supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" (CSR Water Supply & Sewerage Works Vol-5, P No-152, I No- 13.13.6)

1

33101

33101.11

... More
code08 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per pecifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work, (CSR Water Supply & Sewerage Works Vol-5, P No-156, I No- 13.32)

1

6695

6695

... More
code09 - Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 50mm dia (CSR Water Supply & Sewerage Works Vol-5, P No-127, I No- 11.2.6)

90

601

54136.8

... More
code10 - Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any, For 50 mm dia GI collar (CSR Water Supply & Sewerage Works Vol-5, P No-129, I No-11.6.6)

19

275

5225.19

... More
code11 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (CSR Water Supply & Sewerage Works Vol-5, P No-154, I No- 13.22.4)

102

190

19436.1

... More
code12 - Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for, For 50 mm dia GI elbow (CSR Water Supply & Sewerage Works Vol-5, P No-129, I No-11.7.6)

4

275

1100.04

... More
code13 - Supply and delivery at site of brand new best make Non-Return Valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm (CSR Water Supply & Sewerage Works Vol-5, P No-154, I No-13.25.1)

1

1287

1287.5

... More
code14 - Earth work excavation for cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m, (CSR PWD 2023-24 Vol-1, P No-6, I No-1.6.1)

8.1

498

4038.012

... More
code15 - Providing PVC Ringtite Pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) PVC pipes 50mm dia., 6 kg/sqcm & class 5, (CSR Water Supply & Sewerage Works Vol-5, P No-113, I No- 10.1.3)

30

104

3120.9

... More
code16 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm), (CSR ESCOMs SR 2023-24, P No-13, NO-32.03)

0.04

121544

4861.7648

... More
code17 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff, (CSR ESCOMs SR 2023-24, P No-52, NO-21.05)

0.04

21512

860.5032

... More
code18 - Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 32mm dia (CSR Water Supply & Sewerage Works Vol-5, P No-127, I No-11.2.4)

4

392

1569.72

... More
code19 - Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable, Up to 4C x 50 Sqmm, (CSR ESCOMs SR 2023-24, P No-15, NO-35.01)

1

333

333.72

... More
code20 - Fabricating, Supplying and mounting MS Box Made out ….. SWG Suitable for Floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arreangement, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG (CSR PWD 2023-24 Ele SR 2-23-24, P No-20, NO- 5.42.2)

23000

-

10120

... More
code21 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm. (CSR PWD 2023-24 Ele SR 2-23-24, P No-20, NO-5.41.1)

10

314

3141.5

... More
code22 - Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using apered inverted wooden plugs screws, 20"x20"x2.5", (CSR PWD 2023-24 Ele SR 2-23-24, P No-14, I No-5.6.6)

1

335

335.91

... More
code23 - Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter, 3 to 6 HP pumps (CSR Water Supply & Sewerage Works Vol-5, P No-155, I No-13.24.2)

1

10815

10815

... More
code24 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 Amps, (CSR PWD 2023-24 Ele SR 2-23-24, P No-14, I No- 5.7.3)

6

413

2478.18

... More
code25 - Supplying and fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32A TPN, (CSR PWD 2023-24 Ele SR 2-23-24, P No-17, I No- 5.18.7)

1

1768

1768.51

... More
code26 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter, (CSR PWD 2023-24 Ele SR 2-23-24, P No-19, I No-5.31)

1

4521

4521.7

... More
code27 - Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to stablished through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (CSR Water Supply & Sewerage Works Vol-5, P No-157, I No-13.39)

1

3862

3862.5

... More
code28 - Earth work excavation for Pipe Lines by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m, (CSR PWD 2023-24 Vol-1, P No-6, I No-1.6.1)

340.2

498

169596.504

... More
code29 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc..PWD CSR 2023-2024, IN-10.1.6, PN-156, VOL-5. PVC pipes 90mm dia., 6 kg/sqcm & class 3

630

226

142758

... More
code30 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with inimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For sluice Valve of PN -10.0 and 80mm (CSR Water Supply & Sewerage Works Vol-5, P No-22, I No- 2.23.2)

2

10704

21409.58

... More
code31 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing). PVC pipes 250mm dia., 6 kg/sqcm & class 3 (CSR Water Supply & Sewerage Works Vol-5, P No-113, I No-10.1.11)

2

1488

2976.7

... More
code32 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications (CSR PWD 2023-24 Vol-1, P No-7, I No-1.10)

340.2

164

56064.96



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.