Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Electrical and Electronics
Electrical Works
Opening Date6 Nov 2024
Closing Date19 Nov 2024
Tender Amount₹ 10,74,126.19 
Notes
Download

Costs

Summary

Proposed Electrification Works At Sy.no 45 Of Yeladur Village In Tmc Srinivaspura

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Code 4 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required to IEC 60898 b) 6-32 A SP for Workers Rest Room, Toilet Block & DG Room @ Main DB

5

739

3695

... More
Code 5 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required to IEC 60898 c) 6-32 A SP TPN for Pump.

2

1717

3434

... More
Code 6 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick

10

69

690

... More
Code 7 - Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick

10

81

810

... More
Code 8 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary a) 19/20mm dia 2mm thick

150

66

9900

... More
Code 9 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary b) 25mm dia 2mm thick

75

78

5850

... More
Code 10 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary c) 32 mm dia 2.5 mm thick

25

103

2575

... More
Code 11 - supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary. a) 19/20mm dia 2mm thick

100

68

6800

... More
Code 12 - supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary. b) 25mm dia 2mm thick

40

79

3160

... More
Code 13 - supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary. c)32mm dia 2.5 mm thick

10

99

990

... More
Code 14 - Supplying and fixing PVC/metal conduit accessories Deep Junction Boxes 19/20mm deep junction box

20

49

980

... More
Code 15 - Supplying and fixing PVC/metal conduit accessories 25mm deep junction box

15

56

840

... More
Code 16 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete a) up to 50mm conduit in brick wall

5

29

145

... More
Code 17 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete b) up to 50mm conduit CC floor

5

69

345

... More
Code 18 - Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade, COPPER conductor flexible multicore FRLS PVC insulated, 2C X 1.5Sq.mm Cable confirming to the GTP, without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch.

28

285

7980

... More
Code 19 - b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch.

9

394

3546

... More
Code 20 - c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch.

3

570

1710

... More
Code 21 - d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches

3

708

2124

... More
Code 22 - Supplying and flush mounting powder coated/ galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-3Way

12

138

1656

... More
Code 23 - b) 4-5Way

6

177

1062

... More
Code 24 - c) 6-8 Way

6

220

1320

... More
Code 25 - d) 10-12Way

1

319

319

... More
Code 26 - Supplying and fixing superior quality modular switch mounting olycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module

12

137

1644

... More
Code 27 - 4 Module

6

161

966

... More
Code 28 - 6 Module

4

234

936

... More
Code 29 - 8 Module

2

284

568

... More
Code 30 - 10 Module

1

344

344

... More
Code 31 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate asper IS 3854 and IS 1293 Group A 6Amps one way.

34

102

3468

... More
Code 32 - 6Amps 3way socket.

11

171

1881

... More
Code 33 - Stepped Fan Regulator.

3

357

1071

... More
Code 34 - 16Amps one way switch

2

180

360

... More
Code 35 - 6/16Amps universal socket

2

236

472

... More
Code 36 - TV/Telephone socket

2

156

312

... More
Code 37 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core cable in open or concealed system of wiring with specified IS- 694:1990 & confirming to the attached GTP of GROUP -A. a) 1.5 sqmm

180

18

3348

... More
Code 38 - b) 2.5 sqmm

270

29

7884

... More
Code 39 - c) 4 sqmm

125

42

5262.5

... More
Code 40 - d) 6 sqmm

30

63

1914

... More
Code 41 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. a) 1.5 sqmm

20

2

40

... More
Code 42 - b) 2.5 sqmm

55

3

171.6

... More
Code 43 - c) 4 sqmm

20

6

125

... More
Code 44 - d) 6 sqmm

10

6

62.5

... More
Code 45 - Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely a) 20mm

20

23

460

... More
Code 46 - Supplying And Fixing Metal Fan Box with Round Hook.

2

92

184

... More
Code 47 - Supplying patty type fluorescent tube light fitting of 4' -suitable for 28 watts fluorescent tube fitting, made out of M.S. Sheet and stove enameled with HF Electronic Ballast , locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 volts AC . Supply including T5 lamp a) 1x4’ -28 watts

10

669

6690

... More
Code 48 - Supplying patti type fluorescent tube light fitting of 2' - suitable for 14 watts fluorescent tube fitting, made out of M.S. Sheet and stove enameled with HF Electronic Ballast , locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 volts AC . Supply including T8 Fluorescent Tube a) 1x-5'-80 W

4

591

2364

... More
Code 49 - Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 15Watts 230V CFL lamp as required a) 15 watts

2

952

1904

... More
Code 50 - Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.

2

1700

3400

... More
Code 51 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm)

2

2969

5938

... More
Code 52 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved. 48" Sweep (1200mm) 48" Sweep (1200mm)

4

3031

12124

... More
Code 53 - Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.a) On wall/ceiling/Rafter/Girders

18

122

2196

... More
Code 54 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

3

171

513

... More
Code 55 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.

4

492

1968

... More
Code 56 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.2 Pair

25

15

375

... More
Code 57 - 5 pair

10

46

460

... More
Code 58 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.

25

44

1100

... More
Code 59 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

2

4317

8634

... More
Code 60 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.GI strip 25x3mm

15

82

1230

... More
Code 61 - 600x600x3mm GI Plate

2

875

1750

... More
Code 62 - 25x3mm Copper strip 25x3mm

25

82

2050

... More
Code 63 - 600x600x3mm plate

2

875

1750

... More
Code 64 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.Copper wire. a) 12 SWG

60

59

3582

... More
Code 65 - Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed,galvanised,steel strip (except 2CX10Sq.mm wire armoured) confirming to IS- 3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to the attached GTP of GROUP-A.3.5 core 25 sqmm for MESCOM Tapping Pole to Main DB ( 2 Runs)

70

138

9660

... More
Code 66 - 4 core 16 sqmm for Workers rest room, Toilet Block & DG Room from Main DB located @ DG Room ( Two cores spare)

100

117

11700

... More
Code 67 - 4 core 10 sqmm for Street Light from Main DB Located @ DG Room

200

99

19800

... More
Code 68 - Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)In soil (ordinary)

150

78

11700

... More
Code 69 - In soil (hard)

50

106

5300

... More
Code 70 - Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm alround the cable.

150

103

15450

... More
Code 71 - Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as re 6 sqmm 16 qmmquired.6 sqmm 16 qmm

300

10

3240

... More
Code 72 - 25 sqmm 75 qmm

300

16

4860

... More
Code 73 - Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 25 mm dia

8

86

688

... More
Code 74 - 32 mm dia

4

122

488

... More
Code 75 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. a) 1.5 sqmm 10 sqmm Long Barrel

25

7

191.25

... More
Code 76 - 16 sqmm Long Barrel

6

11

67.86

... More
Code 77 - 25 sqmm Long Barrel

8

20

164.72

... More
Code 78 - Supply of LED Streetlight with pressure die cast aluminium housing body

4

31250

125000

... More
Code 79 - Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enameled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7.

5

15000

75000

... More
Code 80 - Supply and erection of …...Mtr RCC Pole including earth work etc,. complete as per the standard technical specification of MESCOM 8 Mtr 145Kg WL

5

6047

30235

... More
Code 81 - Supplying and Fixing ….. including all Hardwares etc complete as per the standard technical specification of MESCOM LT ST Support 50x6 mm

5

173

865

... More
Code 82 - RCC Clamp

5

84

420

... More
Code 83 - GUY Set

5

1320

6600

... More
Code 84 - Supplying and Fixing …..including all Hardwares etc complete as per the standard 1.1 KV Pin Insulator

20

844

16880

... More
Code 85 - No. 8 Strain Insulator

5

14

70

... More
Code 86 - Supplying and Fixing of Rabbit Conductor(6/3.15mm Al +6/3.15mm Steel)

500

47

23500

... More
Code 87 - Supplying and Fixing of P.G.Clamp including all Hardwares etc complete as per the standard technical specification of MESCOM

4

101

404

... More
Code 88 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. (Icu = Ics)100Amps 25kA.

1

5809

5809

... More
Code 89 - Supplying and fixing regular MCCB distribution Panel confirm to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to S8828.8Way

1

7243

7243

... More
Code 90 - DG set Supply, Erection, testing and commissioning of AMF panel suitablefor .....kVA DG set. The panel is of cubical type base/floor mountingcontrol panel with hinged doors, undrilled bottom gland plate, aluminiumBus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earthfault relay, with indications for Mains on, Load on Mains, Battery chargeron Push buttons AMF module by pass Mode, Battery charger unit withinbuilt Auto/Manual and Flat/Boost facility. The complete set shall havesufficient safety and adhere to NEC, NBC 2016, IEC, CPWDspecifications, PCB norms and KSGEI Acts and Rules. 320 KVA to 400 KVA

1

312811

312811

... More
Code 91 - Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with ransparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable ransparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600x600x170mm

2

13728

27456

... More
Code 92 - Supplying of on load change over switches 4 poles, 415V, 50Hz, AC Supply with AC-23A Duty Up to 63Amps

2

4892

9784

... More
Code 93 - Supplying and fixing HRC fuse link on existing switch fuse base with watt loss as per IS-13703. Up to 63Amps

3

232

696

... More
Code 94 - Supplying and fixing HRC fuse units base on existing switch/panel board.) 63A to 125Amps

3

296

888



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.