Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction
Building Construction
Opening Date12 Nov 2024
Closing Soon28 Nov 2024
Tender Amount₹ 1,05,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 Column base(Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)

9.09

11346

103139.5032

... More
006 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates plinth beam(Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)

10.71

9789

104841.4752

... More
007 - Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)

8.74

92140

805309.8054

... More
008 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)

41.79

6580

275006.1993

... More
009 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)

565.36

488

276020.0592

... More
010 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)

258.29

1267

327493.6397

... More
011 - Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)

565.36

303

171784.636

... More
012 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)

26953.06

116

3137066.6534

... More
013 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)

1606.23

585

939708.7992

... More
014 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2

565.36

103

58232.08

... More
015 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)

361.44

75

27176.6736

... More
016 - Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)

361.44

75

27176.6736

... More
017 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)

33.75

2711

91529.6625

... More
018 - Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)

2

25426

50853.16

... More
019 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2)

480

465

223468.8

... More
020 - Open Conduit System:-Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 1.1.1) 19/20 mm dia 2 mm thick Pg No 2 It No 1.1.1 of PART III Utilization (PWD Electrical)

75

71

5330.25

... More
021 - Open Conduit System:-Supplying heavy gauge PVC conduit pipe. dia. mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 1.1.2) 25 mm dia 2 mm thick Pg No 2 It No 1.1.2 of PART III Utilization (PWD Electrical)

150

83

12514.5

... More
022 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet 2.1.1 Short point upto 3Mtr from tapping point to out let via switchPg No 5 It No 2.1.1 of PART III Utilization (PWD Electrical)

12

293

3522.6

... More
023 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet 2.1.2 Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch Pg No 5 It No 2.1.2 of PART III Utilization (PWD Electrical)

12

405

4869.84

... More
024 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet 2.1.3 Long point above 6Mtr upto 10Mtr from tapping point to out let via switch Pg No 5 It No 2.1.3 of PART III Utilization (PWD Electrical)

12

587

7045.2

... More
025 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet 2.1.4 Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out Pg No 5 It No 2.1.4 of PART III Utilization (PWD Electrical) let via switches

5

729

3646.2

... More
026 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet 2.1.5 Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches Pg No 5 It No 2.1.5 of PART III Utilization (PWD Electrical)

3

1066

3198.15

... More
027 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.3.1) 1 mm2 Pg No 5 It No 2.3.1 of PART III Utilization (PWD Electrical)

250

19

4892.5

... More
028 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.3.3) 2.5 mm2 Pg No 5 It No 2.3.3 of PART III Utilization (PWD Electrical)

500

43

21630

... More
029 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.3.4) 4 mm Pg No 5 It No 2.3.4 of PART III Utilization (PWD Electrical)

200

64

12978

... More
030 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.3.5) 6 mm2 Pg No 5 It No 2.3.5 of PART III Utilization (PWD Electrical)

50

94

4738

... More
031 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 2.5.15) 3C x 4 mm2 Pg No 6 It No 2.5.15 of PART III Utilization (PWD Electrical)

60

177

10629.6

... More
032 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 2.6.3) 3C x 6 mm2 Pg No 6 It No 2.6.3 of PART III Utilization (PWD Electrical)

30

252

7570.5

... More
033 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1) 1-2 Way Pg No 8 It No 3.4.1 of PART III Utilization (PWD Electrical)

20

142

2842.8

... More
034 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5) 8 Way Pg No 8 It No 3.4.5 of PART III Utilization (PWD Electrical)

5

268

1344.15

... More
035 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.6) 10-12 Way Pg No 8 It No 3.4.6 of PART III Utilization (PWD Electrical)

5

328

1642.85

... More
036 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.7) 16 Way Pg No 8 It No 3.4.7 of PART III Utilization (PWD Electrical)

2

373

747.78

... More
037 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3.5.1) 1 to 2 Module Pg No 8 It No 3.5.1 of PART III Utilization (PWD Electrical)

20

141

2822.2

... More
038 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3.5.5) 8 Module Pg No 8 It No 3.5.5 of PART III Utilization (PWD Electrical)

5

292

1462.6

... More
039 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box3.5.6) 10-12 Module Pg No 8 It No 3.5.6 of PART III Utilization (PWD Electrical)

5

354

1771.6

... More
040 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3.5.7) 16 Module Pg No 8 It No 3.5.7 of PART III Utilization (PWD Electrical)

2

408

817.82

... More
041 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.1) 6A One Way Switch Pg No 9 It No 3.6.1 of PART III Utilization (PWD Electrical)

40

105

4202.4

... More
042 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.3) 6A Three Way socket Pg No 9 It No 3.6.3 of PART III Utilization (PWD Electrical)

20

176

3522.6

... More
043 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.7) 16A One Way Switch Pg No 9 It No 3.6.7 of PART III Utilization (PWD Electrical)

5

185

927

... More
044 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.10) 6/16A Universal Socket Pg No 9 It No 3.6.10 of PART III Utilization (PWD Electrical)

8

243

1944.64

... More
045 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.9) 32A DP Switch Pg No 9 It No 3.6.9 of PART III Utilization (PWD Electrical)

3

335

1007.34

... More
046 - Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor.5.2.2) Above 12.5 HP upto 25 HP Pg No 14 It No 5.2.2 of PART III Utilization (PWD Electrical)

1

9026

9026.92

... More
047 - Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. Pg No 14 It No 5.1 of PART III Utilization (PWD Electrical)

4

1984

7939.24

... More
048 - Fabricating supplying and mounting MS box made out of SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.5.42.1) 14 SWG Pg No 20 It No 5.42.1 of PART III Utilization (PWD Electrical)

96740

-

50304.8

... More
049 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole 5.15.11) 160 A 25 kA Pg No 17 It No 5.15.15 of PART III Utilization (PWD Electrical

1

13850

13850.41

... More
050 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole 5.15.9) 100 A 25 kA Pg No 17 It No 5.15.9 of PART III Utilization (PWD Electrical)

2

8741

17483.22

... More
051 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT Pg No 17 It No 5.16 of PART III Utilization (PWD Electrical)

2

1754

3508.18

... More
052 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.4) 6-32 A DP Pg No 17 It No 5.18.4 of PART III Utilization (PWD Electrical)

2

761

1522.34

... More
053 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.7) 6-32 A TPN Pg No 17 It No 5.18.7 of PART III Utilization (PWD Electrical)

5

1768

8842.55

... More
054 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.9) 50-63 A TPN Pg No 17 It No 5.18.9 of PART III Utilization (PWD Electrical)

7

3180

22264.48

... More
055 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board Pg No 18 It No 5.21 of PART III Utilization (PWD Electrical)

1

9532

9532.65

... More
056 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Pg No 19 It No 5.33 of PART III Utilization (PWD Electrical)

1

9594

9594.45

... More
057 - Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer Pg No 19 It No 5.36 of PART III Utilization (PWD Electrical)

3

865

2595.6

... More
058 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. Pg No 19 It No 5.38 of PART III Utilization (PWD Electrical)

9

530

4774.05

... More
059 - Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 5.40.1) 100 A 4 x 30 x 6 mm Aluminium Strips Pg No 20 It No 5.40.1 of PART III Utilization (PWD Electrical)

2.5

2538

6347.375

... More
060 - Supplying .A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 5.40.2) 250 A 4 x 30 x 10 mm Aluminium Strips Pg No 20 It No 5.40.2 of PART III Utilization (PWD Electrical)

0.5

3538

1769.025

... More
061 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely.TP & N 5.45.4) 30 A Pg No 21 It No 5.45.4 of PART III Utilization (PWD Electrical)

5

1751

8755

... More
062 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.5.41.1) 40 x 40 x 6 mm Pg No 20 It No 5.41.1 of PART III Utilization (PWD Electrical)

12

314

3769.8

... More
063 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 5.41.4) 50 x 100 x 50 x 6 mm C channel Pg No 20 It No 5.41.4 of PART III Utilization (PWD Electrical)

3

778

2336.04

... More
064 - Supplying of 1440rpm heavy duty exhaust fan with bracket bladesnsuitable to operate on 230V 50Hz, AC Supply complete.6.2.2) 15" Sweep (450 mm) Pg No 30 It No 6.2.2 of PART III Utilization (PWD Electrical

8

4579

36635.04

... More
065 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.6.5.2) 400 mm Sweep Pg No 30 It No 6.5.2 of PART III Utilization (PWD Electrical)

6

3308

19850.16

... More
066 - LED Down light:Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast extruded aluminium housing, with spring loaded falseceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70 efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly. with PF 0.95, power loss should 5% of lamp Wage. short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.11.6.5) LED modular down light 1'x4' 34-36W Pg No 45 It No 11.6.5 of PART III Utilization (PWD Electrical)

12

6074

72899.28

... More
067 - LED Street light.Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lampcompartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material,delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees.CCT 5500K, IP66 optical and electrical ompartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322IEC 60598, LM 79 LM 80 Adherence with RoHS.ULapproved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency1301mw, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABLCPRI any Government certified agency Design Development facility certified by ISO 90012008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer CreeNichia LumiledsOsram make LED ource.11.8.4) LED Streetlight 90 Pg No 46 It No 11.8.4 of PART III Utilization (PWD Electrical)

2

9125

18251.6

... More
068 - LED Flood Light Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp ompartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge ProtectionMin 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application.Compliance to IS 10322 IEC 60598 LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W SystemPower consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.11.9.2) LED Floodlight 100W Pg No 46 It No 11.9.2 of PART III Utilization (PWD Electrical)

5

9770

48852.9

... More
069 - FIXING CHARGES Supplying and Fixing of mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. 13.1.1) Using 25mm dia G.I.Pipe

2

1007

2014.68

... More
070 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.13.9) Using 2 m long 19mm 18 SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickel plated Pg No 56 It No 13.9 of PART III Utilization (PWD Electrical)

12

587

7045.2

... More
071 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Pg No 57 It No 13.10 of PART III Utilization (PWD Electrical)

6

176

1056.78

... More
072 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Pg No 57 It No 13.13 of PART III Utilization (PWD Electrical)

8

728

5825.68

... More
073 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Pg No 56 It No 13.5 of PART III Utilization (PWD Electrical

7

166

1168.02

... More
074 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia Pg No 54 It No 12.56 of PART III Utilization (PWD Electrical)

6

3615

21691.8

... More
075 - GI/Copper strips for grounding connections, using necessary fixing materials as required. 12.58.3) 25 x 6 mm GI strip Pg No 54 It No 12.58.3 of PART III Utilization (PWD Electrical)

55

131

7251.2

... More
076 - GI/Copper strips for grounding connections, using necessary fixing materials as required. 12.58.11) 600 x 600 x 3 mm Copper plate Pg No 55 It No 12.58.11 of PART III Utilization (PWD Electrical)

1

7643

7643.63

... More
077 - 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. 12.59.1) 150 x 50 mm Pg No 55 It No 12.59.1 of PART III Utilization (PWD Electrical).

30

476

14306.7

... More
078 - Providing ABC Powder based MAP 50, 6Kg Supply and installation in position, testing and commissioning 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall labour, usage charges of machinery complete as per specificed.with regards to general guidelines of fire safety Pg No 62 It No 15.4 of PART III Utilization (PWD Electrical)

2

2935

5871

... More
079 - Providing 4 Kg Fire Extinguisher Powder Based Supply and installation of 4kg Stored Pressure Type, Pressure Guage, Gross Weight 7.4Kg, empty weight 3.4 Kg, Can Height 480 MM, Diameter 160 MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, Can construction Deep drawn & Co Mig welded, valve Construciton Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60 MM, IS 15683 and CE Approved 5 years warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete Pg No 66 It No 15.15 of PART III Utilization (PWD Electrical)

2

3450

6901

... More
080 - Providing 4.5Kg C02 Wheel Type Supply and installation of 4.5Kg C02 gas valve type Fire Extinugisher, Trolley Mounted, Easy Weight Management used Unused Mechanism, Gross Weight 19.1 Kg. empty Weight14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved, 1YearWarranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete Pg No 73 It No 15.35 of PART III Utilization (PWD Electrical)

1

8755

8755

... More
081 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.13) 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm)Pg No 13 It No 32.13 of PART II Distribution (ESCOMs)

0.15

327449

49117.404

... More
082 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.12) 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) Pg No 13 It No 32.12 of PART II Distribution (ESCOMs)

0.1

213409

21340.982

... More
083 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.08)25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) Pg No 13 It No 32.08 of PART II Distribution (ESCOMs)

0.15

185239

27785.898

... More
084 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.05) 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) Pg No 13 It No 32.05 of PART II Distribution (ESCOMs)

0.2

146097

29219.452

... More
085 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.03) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) Pg No 13 It No 32.03 of PART II Distribution (ESCOMs)

0.2

121544

24308.824

... More
086 - Heavy Duty Copper Terminal Long Barrel 59.04) 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm Pg No 26 It No 59.04 of PART II Distribution (ESCOMs)

16

91

1466.72

... More
087 - Heavy Duty Copper Terminal Long Barrel 59.03) 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm Pg No 26 It No 59.03 of PART II Distribution (ESCOMs)

32

59

1911.68

... More
088 - Heavy Duty Copper Terminal Long Barre 59.01)25 Sqmm Copper Terminal, Apprx Wt: 11 Gm Pg No 26 It No 59.01 of PART II Distribution (ESCOMs)

164

27

4560.84

... More
089 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 21.06) 35 to 95 Sqmm Pg No 52 It No 21.06 of PART II Distribution (ESCOMs)

0.25

32073

8018.2925

... More
090 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 21.05) 2.5 to 25 Sqmm Pg No 52 It No 21.05 of PART II Distribution (ESCOMs)

0.55

21512

11831.919

... More
091 - Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work Pg No 5 It No 1.4.1 of Vol 1 of PWD SR 2023-24

62.5

249

15578.75

... More
092 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications

62.5

164

10300



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.