Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction
Civil Works Others
Opening Date3 Jan 2025
Closing Date22 Jan 2025
Tender Amount₹ 41,49,794.17 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ( Page no 48, item no 8.41,Buildings SR 2023-24 Volume-2 ).

473.66

187

88593.3664

... More
code05 - Providing waterproof treatment to Raft Slab using 2 coats of acrylic co polymer elastomeric Acrylic co-polymer elastomeric sealer & protector. The surface shall be prepared free of tar, dust, fungus, loose particles etc., The surface shall be applied with basecoat of healer sealer crystallization liquid and then Acrylic co-polymer elastomeric sealer & protector, wetting agent and liquid (1:1:6) over the prepared surface. In addition, making haunch at junction of Wall and Slab visible cracks are opened and sealed with flexicrack paste. Over this one coat of flexible cementations membrane (FCM), Spreading one layer of HDPE membrane as reinforcing material (over FCM) with one primer coat of Acrylic co-polymer elastomeric sealer & protector & applying second coat of Acrylic co-polymer elastomeric sealer & protector liquid over the primer coat - conforming to ASTM C 1202, DIN 1048 part 5, The work shall be carried out as per the directions of the Engineer in charge.( Buildings 20023-24, Volume 2, Pg 157 & item no 15.2)

266.1

1176

312933.6

... More
code06 - Providing and laying in position Cement Concrete for levelling course for all works The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications ( SR 2023-24, Volume 1, Pg 15 & item no 2.1.6)

38.52

7425

286034.112

... More
code07 - Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering , providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( SR 2023-24, Volume 2, Pg 42 & item no 8.6.2)

329.83

480

158476.7184

... More
code08 - Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge (P.No: 187 , Sl.No 19.2.1 vol 2 sr 2023-24 ).

3.19

1862

5941.5664

... More
code09 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (Page No. 8 Item No.1.14 VOL 1 SR 2023-24).

19.53

499

9761.094

... More
code10 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Foundation in c.m 1:6 (P No 9 Sl No. 5.5 vol 2 sr 2023-24)

7.81

7138

55754.6528

... More
code11 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For super structure in c.m 1:6 (P No 9 Sl No. 5.7 vol 2 sr 2023-24)

13.39

7565

101303.384

... More
code12 - Providing Raised and cut pointing: Pointing on work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.. (Page No.44 Item No.8.20, vol 2 sr 2023-24 )

49.5

518

25668.72

... More
code13 - Providing and laying Vitrified tiles and Tile adhesive with thickness 9-10 mm in floor with different sizes with water absorption less than 0.5% ,anti-slip surface for the pool deck, steps, and walkways to prevent slipping when wet,UV-resistant pigments to prevent fading due to constant exposure to sunlight ,Slip Resistance Rating R11-R12 for walkways and pool decks,Easy to clean and maintain, resistant to mildew and algae buildup due to their non-porous surface ,Tiles is resistant to pool chemicals like chlorine, acids, and cleaning agents , Tiles is frost-resistant for outdoor pools in colder climates to prevent cracking during freezing conditions. They comply with ISO 10545-12 standards for frost resistance, and with in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (waterbased) performs Exceptionally well in wet condition , making it suitable for a wide range of application whether embraking on a renovating on a existing floors. Also it has High bond Strength ,Usefull for bed 3-12mm may go to 15mm in a limited extent,Thixotropic formula, Self curing properties. The adhesive have C2 class standards under EN 12004, which indicates improved cementitious adhesives with higher bond strength. (Approved rate)

455.36

1848

841505.28

... More
code14 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ( Page no 71, item no 10.14 ,Buildings SR 2023-24 Volume-2 ).

34.35

1238

42550.032

... More
code15 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. ( Page no 71, item no 9.10 ,Buildings SR 2023-24 Volume-2 ).

2.4

1238

2972.928

... More
code16 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. ( Common SR Volume 2 P.No. 62 I.No. 9.20)

455.36

234

106590.6688

... More
code17 - Supply of 100 watts LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.(2024-25 Common SR EL P.No. 46 I.No. 11.9.2)

9

9486

85374

... More
code18 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 120 watts (2024-25 Common SR EL P.No. 46 I.No. 11.8.5)

1

10060

10060

... More
code19 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 70watts (2024-25 Common SR EL P.No. 46 I.No. 11.8.3)

7

5992

41944

... More
code20 - Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.(2024-25 Common SR EL P.No. 56 I.No. 13.7.2)

17

263

4471

... More
code21 - Supplying of 20 watts feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.(2024-25 Common SR EL P.No. 56 I.No. 13.7.2)

17

690

11730

... More
code22 - Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. (2024-25 Common SR EL P.No. 21 I.No.5.44.1)

6

4512

27072

... More
code23 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (2024-25 Common SR EL P.No.8 I.No.3.3.5)

2

219

438

... More
code24 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (2024-25 Common SR EL P.No.8 I.No.3.3.5)

2

284

568

... More
code25 - Supplying and fixing 6 Amps one way switch . (2024-25 Common SR EL P.No.9 I.No.3.6.1)

3

102

306

... More
code26 - Supplying and fixing 6 Amps Socket . (2024-25 Common SR EL P.No.9 I.No.3.6.3)

3

171

513

... More
code27 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP (2024-25 Common SR EL P.No.17 I.No.5.18.1)

5

415

2075

... More
code28 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPN (2024-25 Common SR EL P.No.17 I.No.5.18.8)

1

3044

3044

... More
code29 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP (2024-25 Common SR EL P.No.17 I.No.5.18.4)

4

739

2956

... More
code30 - Providing and fixing Overhead rain showers of minimum dimension 225x225mm & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class (2024-25 Common SR Volume 2 P.No.143 I.No.14.81.a)

10

1210

12107.2

... More
code31 - Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. (2024-25 Common SR Volume 2 P.No.135 I.No.14.19.2)

6

2469

14817.6

... More
code32 - Providing and fixing Angle cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete. (2024-25 Common SR Volume 2 P.No.139 I.No.14.54.b)

4

2148

8592.64

... More
code33 - Providing and fixing German Polyamide flexible connection hose with winged nuts 450mm with all concealed fitting arrangements & all necessary accesories complete. (2024-25 Common SR Volume 2 P.No.142 I.No.14.72)

5

327

1635.2

... More
code34 - Providing and fixing Single flow hand showers with Anti lime jets with Rain, Mist & Massage settings having 1.5m Extendable flexible tube and holder & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete. (2024-25 Common SR Volume 2 P.No.143 I.No.14.80.b )

2

3221

6442.24

... More
code35 - Providing and fixing Flush valve soft touch made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete. (2024-25 Common SR Volume 2 P.No.145 I.No.14.94.b)

1

4665

4665.92

... More
code36 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. (2024-25 Common SR Volume 2 P.No.131 I.No.14.3.2)

1

6501

6501.6

... More
code37 - Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete.(2024-25 Common SR Volume 2 P.No.138 I.No.14.48.b

2

2928

5857.6

... More
code38 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc (2024-25 Common SR Volume 2 P.No.113 I.No.10.1.7)

53

460

24396.96

... More
code39 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (2023-24 Common Volume 5 P.No. 191 I.No. 16.9)

4

6108

24433.92

... More
code40 - Repairs and maintenance of Transformer yard at Swimming Pool. Dismantling of all HT jumper connections of HT yard Structure and making new Jumper Connections with Rabbit wires by replacing the 11KV/433 Volts pin insulators, nuts bolts and clamps wherever necessary . Cleaning the contacting points of GOS including incoming GOS, Cleaning the rusted parts of GOS and replacing the contact rods if necessary. Greasing the rotating elements of GOS Assembly. Replacing the all the edge fuse and contacts of of Transformer. Filtration of Transformer Oil of 11KV /433 Volts 100KVA of Distribution Transformer. Oil Filtration of 100KVA 11KV/433volts Transformer by using necessary vehicle mounted filtration machine to remove moisture from oil and top- up of oil if required including the replacement of Breather Assembly Unit with Silica Gel. Cleaning and scraping the entire HT structure, metal poles, Angulars with emery papers and wire brushes and painting the surface with Single Coat Metal Primer and 2 coats of Synthetic Enamel Paint over the Primary Coat. Painting of 100KVA Transformer completely after washing the transformer to remove oil, grease, dust or any other foreign materials etc., complete as per the directions of Engineer-in-charge. The quoted rate includes all materials, labour , transportation, tools and machineries and painting complete after deducting the cost of released materials if any.(Approved Rate)

1

98000

98000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.