Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction
Construction Material
Opening Date13 Jan 2025
Closing Date28 Jan 2025
Tender Amount₹ 78,49,999.98 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Centering Charges 8%

8.89

11210

99660.456

... More
code05 - Centering charge 70%

65.7

7192

472566.96

... More
code06 - KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)

8.2

9694

79491.456

... More
code07 - KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)

9.03

92140

832030.6113

... More
code08 - KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)

32.75

6580

215516.9425

... More
code09 - KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)

360.89

488

176193.7158

... More
code10 - KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)

134.64

1267

170714.0952

... More
code11 - KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)

293.04

303

89040.204

... More
code12 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)

21800

116

2537302

... More
code13 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)

1159.38

585

678283.6752

... More
code14 - KSRB 8-8. 51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge (Item No. 8.51, Page No. 50,Vol.2)

293.04

103

30183.12

... More
code15 - KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)

134.64

75

10123.5816

... More
code16 - KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)

134.64

75

10123.5816

... More
code17 - KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)

29.25

2711

79325.7075

... More
code18 - KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)

2

25426

50853.16

... More
code19 - KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)

300

465

139668

... More
code20 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.17, I.No.5.15.1 & 5.15.9 in CSR Electrical SR Volume-6 2023-24) Three Pole- 100 A 25 kA

3

6268

18805.74

... More
code21 - Four Pole-100 A 25 kA

1

8741

8741.61

... More
code22 - Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21, I.No.5.46.1 & 5.46.6 in CSR Electrical SR Volume-6 2023-24) 16-32 A SP

6

216

1297.8

... More
code23 - TP 63 A

8

1230

9846.8

... More
code24 - Supplying.........A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.(P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24) 100 A 4 x 30 x 6 mm Aluminium Strips

10

2538

25389.5

... More
code25 - SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron..andM.S.Flat......withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24) 40 x 40 x 6 mm

6

314

1884.9

... More
code26 - Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24) 14 SWG

35000

-

17850

... More
code27 - Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15, I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24) 25 A

9

1328

11958.3

... More
code28 - Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)

3

4988

14964.87

... More
code29 - Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)

3

1369

4109.7

... More
code30 - Supplying and fixing of metal clad industrial plugs and sockets. (P.No.09, I.No.3.13.3 & 3.13.4 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 16 Amps

2

465

931.38

... More
code31 - 32 Amps

2

628

1256.3

... More
code32 - Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)

4

478

1915.8

... More
code33 - Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)

1

465

465.56

... More
code34 - Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)

4

206

824

... More
code35 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.18, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)

1

164

164.8

... More
code36 - Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)

4

578

2315.44

... More
code37 - Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24)

1

1004

1004.25

... More
code38 - Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)

5

494

2472

... More
code39 - Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) .ESCOM SR 2023-24, P.No.13. I No. 32.11

0.03

184342

5530.2657

... More
code40 - 4Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24, P.No.13 I No. 32.08

0.02

185239

3704.7864

... More
code41 - 4Cx16 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.05 Pg.13

0.02

146097

2921.9452

... More
code42 - 4Cx10 Sqmm Cu Ar cable.ESCOM SR 2023-24 I No. 32.03 Pg.13

0.02

121544

2430.8824

... More
code43 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. (P.No.52, I.No.21.05 &21.06 of 2023-24 PWD Electrical Volume-6 SR) LT Cable-2.5 to 25 Sqmm

0.05

21512

1075.629

... More
code44 - LT Cable-35 to 95 Sqmm

0.03

32073

962.1951

... More
code45 - Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24 In all kind of soils, Depth upto 1.50m

6.75

498

3365.01

... More
code46 - Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.

2

195

391.4

... More
code47 - ESCOM SR 2023-24 I No. 22.14 Pg.53 3.5Cx50 Sqmm Al Ar cable.

12

96

1161.84

... More
code48 - Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2 2.5 to 25 sqmm. .ESCOM SR 2023-24 I No. 22.13 Pg.53 ESCOM SR 2023-24 I No. 22.13 Pg.53

25

71

1776.75

... More
code49 - PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-225mm dia PVC 2mm thick conduit.

25

83

2085.75

... More
code50 - PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2 32mm dia PVC 2.5mm thick conduit.

20

109

2183.6

... More
code51 - PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2 40mm dia PVC 2.5mm thick conduit.

20

153

3069.4

... More
code52 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox,the other end of the wires shall be terminated with sufficient loose length in a wood/PVCround block.complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5

10

293

2935.5

... More
code53 - Medium point above 3 Mtr upto 6 Mtr from tapping point to outlet via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5

10

405

4058.2

... More
code54 - Long point above 6 Mtr upto10Mtr from tapping point to outlet via switch PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5

6

587

3522.6

... More
code55 - Two outlet in a row,above 3 Mtr upto 6 Mtr from tapping point to outlet via switches..PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5

5

729

3646.2

... More
code56 - Three outlet in a row,above 6 Mts upto10 Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5

4

1066

4264.2

... More
code57 - Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5

200

19

3914

... More
code58 - PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5 1.5 Sqmm Cu FRLS wire.

100

26

2678

... More
code59 - PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-3 2.5 Sqmm Cu FRLS wire.

150

43

6489

... More
code60 - PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5 4.0 Sqmm Cu FRLS wire.

75

64

4866.75

... More
code61 - PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5 6.0 Sqmm Cu FRLS wire.

50

94

4738

... More
code62 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box.10 - 12 Way Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8

5

354

1771.6

... More
code63 - PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-8 3 Module.

4

165

663.32

... More
code64 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way PWD Electrical SR-2023-24, ITEM NO:3.3.2 ,CH-3, PAGE NO-8

5

127

638.6

... More
code65 - PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8 10-12 Way

5

268

1344.15

... More
code66 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9

4

105

420.24

... More
code67 - PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9 6A 3 way socket.

4

176

704.52

... More
code68 - PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9 6/16A Universal socket.

2

243

486.16

... More
code69 - Light fixture: Supply of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000hr@ Lumen Maintenance of 70%, CCT5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage /Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60 Hz application. Compliance to IS 10322/IEC60598 ,LM79 & LM80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with.......W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier wordmark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working understand ard electrical conditions as mentioned above should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source.-LED Floodlight 100W. (PWD Electrical SR-2023-24, ITEM NO:11.9.2, PAGE NO-46

10

9770

97705.8

... More
code70 - GI/Copper strips for grounding connections, using necessary fixing materials as required.25x6mm GI Earth Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54

40

84

3378.4

... More
code71 - perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-54 300x50mm 2 mm thick

15

604

9069.15

... More
code72 - Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54

2

3615

7230.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.