Directorate Of Municipal Administration Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Directorate Of Municipal Administration - DMA Tender
Civil And Construction
Excavation
Opening Date9 Jul 2024
Closing Date24 Jul 2024
Tender Amount₹ 14,96,039.91
Costs
EMD
₹ 37,500Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/OW/WORK_INDENT19174Bid Award Id
ViewTender No
DMA/2024-25/OW/WORK_INDENT19174Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
code04 - Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (CSR 2023-24),Vol- II, I.No : 5.4, Page No : 9
5.3158
6389
33962.6462
code05 - Providing Flush/ Ruled/ Struck or weathered pointing: Pointing on tile brickwork with cement mortar 1:3(1 cement:3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24),Vol- II, I.No : 8.18, Page No : 44
11.86
236
2798.96
code06 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CSR 2023-24),Vol- I, I.No : 1.9, Page No : 7
8.67
266
2306.22
code07 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (CSR 2023-24),Vol- II, I.No : 6.8, Page No : 14
20.03
7969
159619.07
code08 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. For Buildings (CSR 2023-24), Vol-I, I.No : 2.11, Page No : 18
1.034
89457
92498.538
code09 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (CSR 2023-24),Vol-I, I.No : 2.4.3, Page No : 75
3.0399
9377
28505.963073
code10 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to
complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (CSR 2023-24),Vol-I, I.No : 2.5.2, Page No : 79
8.78
10127
88920.6792
code11 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CSR 2023-24),VolI-I, I.No : 11.5.1, Page No : 77
7.02
4478
31435.56
code12 - Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. (CSR 2023-24),Vol-II, I.No : 12.53, Page No : 104
3.15
1588
5002.2
code13 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (CSR 2023-24),Vol-II, I.No : 12.85, Page No : 109
1.35
5719
7720.65
code14 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24),Vol-II, I.No : 8.8, Page No : 42
88.0299
371
32659.0929
code15 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24),Vol-II, I.No : 8.2.2, Page No : 41
66.6699
279
18600.9021
code16 - Providing 12 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24),Vol-II, I.No : 8.1.2, Page No : 41
27.85
241
6711.85
code17 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). (CSR 2023-24),Vol-II, I.No : 8.33.1, Page No :46
165.1599
158
26095.2642
code18 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.(CSR 2023-24),Vol-II, I.No : 10.14, Page No : 71
35.5999
1106
39373.4894
code19 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge..(CSR 2023-24),Vol-II, I.No : 9.19, Page No : 61
33.39
1173
39166.47
code20 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter. (CSR 2023-24),Vol-II, I.No : 13.48, Page No :125
26.4
291
7682.4
code21 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (CSR 2023-24),Vol-II, I.No : 14.1.1, Page No :131
2
4884
9768
code22 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. (CSR 2023-24),Vol-II, I.No : 10.8, Page No :70
3
4884
14652
code23 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (CSR 2023-24),Vol-II, I.No : 14.4.1, Page No :131
2
4454
8908
code24 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (CSR 2023-24),Vol-II, I.No : 14.7.1, Page No :132
2
3082
6164
code25 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall, 15 mm nominal dia Pipes (CSR 2023-24),Vol-II, I.No : 13.31.1, Page No :122
60
182
10920
code26 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (CSR 2023-24),Vol-II, I.No : 13.34, Page No :123
1000
9
9000
code27 - Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (CSR 2023-24),Vol-II, I.No : 13.2.1, Page No :117
6
286
1716
code28 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.. (CSR 2023-24),Vol-II, I.No : 11.25.2, Page No :123
225
136
30600
code29 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24),Vol-II, I.No : 8.41, Page No : 48
9
167
1503
code30 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm and down size graded crushed coarse aggregates (CSR 2023-24),Vol-II, I.No : 2.16, Page No : 60
1.92
6243
11986.56
code31 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. In All kinds of soils, Depth Upto 1.50 m (Common SR of Engineering Departments 2023-24),Vol- I, :1.17.1, Page No :10
21.11
262
5530.82
code32 - Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5 (CSR 2023-24),Vol-II, I.No : 13.5.1, Page No :125
4
1706
6824
code33 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 200mm dia. (CSR for Water Supply & Sewerage Works 2023-24),Vol- V, I.No:10.2.3 , Page No :114
45
385
17325
code34 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.(Common SR of Engineering Departments 2023-24),Vol- I, :1.10, Page No :7
12.2443
160
1959.088
code35 - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401, For Grading -II Material (CSR 2023-24),Vol-II, I.No : 9.25, Page No :63
20.4
2560
52224
code36 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(CSR 2023-24),Vol-III, I.No : 4.1, Page No :23
193.8
800
155040
code37 - Concealed Conduit System Supplying heavygauge PVC conduit pipe......mm dia..........mm thick confirming to IS250 with suitable size bends, metal/PVC Junctionboxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes and pipe ends should be covered using PVC enenclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick .PWD Elec. SR 2-23-24,Vol-VI, I.No : 1.2.2, Page No :2
65
78
5070
code38 - Supplying and fixing PVC/metal conduit accessories.(3/1.5.2) deep junction box 25mm junction box. PWD Elec. SR 2-23-24,Vol-VI, I.No : 1.5.2, Page No :3 25mm dia deep junction box
8
56
448
code39 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.Cwall, including necessary rawl plugs, Machine/NF screws etc., complete. PWD Elec. SR 2-23-24,Vol-VI, I.No : 3.3.1, Page No : 8, 1-2 way modular box
8
103
824
code40 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.Cwall, including necessary rawl plugs, Machine/NF screws etc., complete. PWD Elec. SR 2-23-24,Vol-VI, I.No : 3.3.6, Page No : 8, 10-12 way modular box
6
261
1566
code41 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting backplate with required nos. of machine screws, bolts nut setc., complete on the existing metal/PVC box. PWD Elec. SR 2-23-24,Vol-VI, I.No : 3.5.2, Page No : 8, 3 Module
6
161
966
code42 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Elec. SR 2-23-24,Vol-VI, I.No : 3.6.3, Page No : 9, 6A Three Way socket
4
171
684
code43 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Elec. SR 2-23-24,Vol-VI, I.No : 3.6.4, Page No : 9, Stepped Fan Regulator 2 Module
1
357
357
code44 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PWD Elec. SR 2-23-24,Vol-VI, I.No : 3.6.9, Page No : 9, 32A DP Switch
1
326
326
code45 - Supplying And Fixing Metal Fan Box with Round Hook.. PWD Elec. SR 2-23-24,Vol-VI, I.No : 1.13 Page No :3
1
117
117
code46 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm(Earthwire) FRLS multistrand PVC insulated copper wire (confirmingtoIS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (Short point upto 3Mtr from tapping point to out let via switch box). PWD Elec. SR 2-23-24,Vol-VI, I.No : 2.2.1 Page No :5- Short point upto 3Mtr
4
269
1076
code47 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm(Earthwire) FRLS multistrand PVC insulated copper wire (confirmingtoIS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box). PWD Elec. SR 2-23-24,Vol-VI, I.No : 2.2.2 Page No :5, Medium point above 3Mtr
4
379
1516
code48 - Wiring for lighting/power circuit using oneof FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 (1.5 mm2). PWD Elec. SR 2-23-24,Vol-VI, I.No : 2.3.2 Page No :5, 1.5 sqmm
135
26
3510
code49 - Wiring for lighting/power circuit using oneof FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 (2.5 mm2). PWD Elec. SR 2-23-24,Vol-VI, I.No : 2.3.2 Page No :5, 2.5 sqmm
270
42
11340
code50 - Wiring for lighting/power circuit using oneof FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 (2.5 mm2). PWD Elec. SR 2-23-24,Vol-VI, I.No : 2.3.3 Page No :5, 4 sqmm
135
63
8505
code51 - Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.(10/3.10) 80mm. PWD Elec. SR 2-23-24, Vol-VI, I.No : 3.10.2, Page No : 9, Plastic plate 80/90 mm
10
15
150
code52 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. PWD Elec. SR 2-23-24, Vol-VI, I.No : 5.18.4, Page No : 9, 6-32 Amps DP
1
739
739
code53 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. PWD Elec. SR 2-23-24, Vol-VI, I.No : 5.18.7, Page No : 9, 50-63Amps TPN
1
1717
1717
code54 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.12 Way SP & N PWD Elec. SR 2-23-24, Vol-VI, I.No : 5.19.9, Page No : 18, 12 Way SP & N
1
2329
2329
code55 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. PWD Elec. SR 2-23-24, Vol-VI, I.No : 5.35, Page No : 19, Electronic Trivector Meter
1
5705
5705
code56 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 12 mm dia. PWD Elec. SR 2-23-24, Vol-VI, I.No : 12.56, Page No :54, 50-63Amps TPN
1
3510
3510
code57 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. ESCOMs SR 2-23-24, Vol-VI, I.No : 8.02, Page No :5, 8 SWG GI Wire
15
75
1125.6
code58 - Supplying of ....... feet - LED PVC Square Batten ..W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50Hz & Power factor greater than0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1x 4' - 20 /22 w PWD Elec. SR 2-23-24, Vol-VI, I.No : 11.3.2, Page No :43
4
690
2760
code59 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per watt, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldless than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' /1' X 4' 34 -36watt PWD Elec. SR 2-23-24, Vol-VI, I.No : 11.6.5, Page No :45
1
5898
5898
code60 - Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling /Rafter / Girders PWD Elec. SR 2-23-24, Vol-VI, I.No : 13.7.1, Page No :56
5
122
610
code61 - Supplying capacito type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230V, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model. PWD Elec. SR 2-23-24, Vol-VI, I.No : 6.3.2, Page No :30
1
3031
3031
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements