Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Solid Waste Management
Opening Date16 Aug 2024
Closing Date31 Aug 2024
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring stripthickness and resistivity 95 Sqmm 3.5 Core(21 GI Strip-4 X 0.8)as per IS-3975.(P.No.9, I.No.32.05 & 32.14 in Bescom Common SR 2021-22 Part III)

0.2

514040

102808

... More
code05 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring stripthickness and resistivity 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)as per IS-3975.(P.No.9, I.No.32.05 & 32.14 in Bescom Common SR 2021-22 Part III)

0.2

1186071

237214.2

... More
code06 - Hydraulic Crimping Tool with suitable Dies for crimping lugs of size upto 400 Sqmm.(P.No.22, I.No.65.58 in Bescom Common SR 2021-22 Part III)

1

10626

10626

... More
code07 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff..(P.No.9, I.No.31.01 & 31.05 in Bescom Common SR 2021-22 Part IV) 2.5 to 25 Sqmm

0.1

16159

1615.9

... More
code08 - aying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff..(P.No.9, I.No.31.01 & 31.05 in Bescom Common SR 2021-22 Part IV) 3x95 to 150 Sqmm

0.2

45284

9056.8

... More
code09 - Supplying and Fixing of Heavy duty cable glands suitable for UG Cable of 1.1 KV class(metal only) .(P.No.42, I.No.6.11.8 inPWD Electrical SR 2019-20 ) 100mm

4

965

3860

... More
code10 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.15, I.No.5.41.3 inPWD Electrical SR 2020-21 ) 75 x 75 x 6 mm

20

497

9940

... More
code11 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.15, I.No.5.42.2 inPWD Electrical SR 2020-21 ) 16 SWG

43200

-

16416

... More
code12 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.(P.No.12, I.No.5.14.1 inPWD Electrical SR 2020-21 ) 100 A 25 kA

4

5641

22564

... More
code13 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.(P.No.12, I.No.5.14.1 inPWD Electrical SR 2020-21 ) 125 A 25 kA

1

8586

8586

... More
code14 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. (P.No.15, I.No.5.40.2 inPWD Electrical SR 2020-21 ) 250 A 4 x 30 x 10 mm Aluminium Strips

20

3078

61560

... More
code15 - Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.14, I.No.5.22 inPWD Electrical SR 2020-21 )

1

407

407

... More
code16 - Supplying, fixing and wiring 0 to 100 A Direct Reading AC analog type Ammeter (P.No.14, I.No.5.25 inPWD Electrical SR 2020-21 )

1

472

472

... More
code17 - Supplying, fixing and wiring rotary selector switch suitable for Ammeter.(P.No.14, I.No.5.27 inPWD Electrical SR 2020-21 )

1

178

178

... More
code18 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter (P.No.14, I.No.5.28 inPWD Electrical SR 2020-21 )

1

146

146

... More
code19 - Supplying and fixing digital frequency meter with latest micro controller technology, ultra bright 4 digit LED display, from 30-500V AC and optional or relay output for high/low frequency and wiring complete.(P.No.14, I.No.5.32 inPWD Electrical SR 2020-21 )

1

875

875

... More
code20 - Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. (P.No.14, I.No.5.34 in PWD Electrical SR 2020-21 )

3

505

1515

... More
code21 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (P.No.14, I.No.5.38 in PWD Electrical SR 2020-21 )

6

464

2784

... More
code22 - Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. -63 A SP (P.No.16, I.No.5.46.1 in PWD Electrical SR 2020-21 )

4

338

1352

... More
code23 - Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of700mm using NF screws. -25 mm dia 2 mm thick (P.No.01, I.No.1.1.2 in PWD Electrical SR 2020-21 )

300

80

24000

... More
code24 - Supplying and fixing PVC/metal conduit Deep junction box .25 mm deep Junction box (P.No.01, I.No.1.5.2 in PWD Electrical SR 2020-21)

75

51

3825

... More
code25 - Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely-25 mm .(P.No.02, I.No.1.9.2 in PWD Electrical SR 2020-21 )

100

31

3100

... More
code26 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.-2.5 mm2 (P.No.03, I.No.2.3.3 & 2.3.7 in PWD Electrical SR 2020-21 ) 2.5 mm2

500

40

20000

... More
code27 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.-2.5 mm2 (P.No.03, I.No.2.3.3 & 2.3.7 in PWD Electrical SR 2020-21 )16 mm2

20

318

6360

... More
code28 - Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires. -.(P.No.45, I.No.13.1.2 in PWD Electrical SR 2020-21 ) Using 32mm dia G.I.Pipe

25

902

22550

... More
code29 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.(P.No.45, I.No.13.5 in PWD Electrical SR 2020-21 )

25

189

4725

... More
code30 - Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.(P.No.164,SOR Code:P430A in KUWS&DB SR 2021-22)

4

3750

15000

... More
code31 - GI Pipe B - Class as per IS-1239 .GI Pipe - 150 mm Dia (P.No.16, I.No.49.09 in Bescom Common SR 2021-22 Part III)

10

1529

15290



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.