Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Civil And Construction
Road Construction
Opening Date22 Aug 2024
Closing Date6 Sep 2024
Tender Amount₹ 2,93,31,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Code4 - Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

0.55

12038

6621.4445

... More
Code5 - Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

0.55

7648

4206.565

... More
Code6 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- as per Engineer Incharge

20.4455

100191

2048472.26472

... More
Code7 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- as per Engineer Incharge

301

297

89673.92

... More
Code8 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

23

6343

145904.64

... More
Code9 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. ---- as per Engineer Incharge

19

6963

132297.76

... More
Code10 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing- Concrete ---- as per Engineer Incharge

13

7664

99632.39

... More
Code11 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columns upto plinth ---- as per Engineer Incharge

1

12063

12063.74

... More
Code12 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Column Ground Floor ---- as per Engineer Incharge

4

13029

52116.28

... More
Code13 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Column First Floor ---- as per Engineer Incharge

6

13159

78956.16

... More
Code14 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Beam and Lintel Ground Floor ---- as per Engineer Incharge

12

12262

147151.92

... More
Code15 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Lintel and Beam First Floor ---- as per Engineer Incharge

8

12385

99082.24

... More
Code16 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Chejja Ground Floor ---- as per Engineer Incharge

3

11113

33339.09

... More
Code17 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Chejja First Floor ---- as per Engineer Incharge

3

11224

33672.48

... More
Code18 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Slab ---- as per Engineer Incharge

38

11496

436857.12

... More
Code19 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sump wall ---- as per Engineer Incharge

16

8430

134889.28

... More
Code20 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) i) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Staircase ---- as per Engineer Incharge

3

7664

22992.48

... More
Code21 - Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) For FF ---- as per Engineer Incharge

8.533

101193

863486.35408

... More
Code22 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth ---- as per Engineer Incharge

508.8

106

54136.32

... More
Code23 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- as per Engineer Incharge

102.51

179

18369.792

... More
Code24 - Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column ---- as per Engineer Incharge

2.17

12159

26385.8546

... More
Code25 - Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Beam and Lintel ---- as per Engineer Incharge

5.85

11444

66948.102

... More
Code26 - Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Slab ---- as per Engineer Incharge

10.68

10728

114584.3316

... More
Code27 - Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Staircase ---- as per Engineer Incharge

1.62

10268

16635.051

... More
Code28 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

0.49

7032

3446.0083

... More
Code29 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

25

7451

186278.5

... More
Code30 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

8

10644

85155.84

... More
Code31 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

7

12063

84446.18

... More
Code32 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

12

11354

136249.32

... More
Code33 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

2.5

10289

25724.15

... More
Code34 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

9

7805

70253.55

... More
Code35 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- as per Engineer Incharge

36.5

10644

388523.52

... More
Code36 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth PWD SR 2023-24 Vol:1 P.NO.8 I.No:1.15.1 ---- as per Engineer Incharge

332.35

406

135120.216

... More
Code37 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement ncluding cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Sl. No.2.11.H, P.No. 18/CSR 2023-24 VOL-1 ---- as per Engineer Incharge

1.2328

88492

109093.332096

... More
Code38 - Providing and laying in Cement Concrete for all Basement & surface levelworks, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevantIS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including alllead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( Page no 16, item no2.3.1 , UNI SR 2023-24) ---- as per Engineer Incharge

25.8

9560

246657.804

... More
Code39 - Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.. ---- as per Engineer Incharge

789.23

1311

1035090.9296

... More
Code40 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (1 cement : 6 coarse sand) ---- as per Engineer Incharge

79.83

7155

571237.9344

... More
Code41 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- as per Engineer Incharge

278.7

1378

384249.264

... More
Code42 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- as per Engineer Incharge

869

409

356220.48

... More
Code43 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- as per Engineer Incharge

920

194

179289.6

... More
Code44 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- as per Engineer Incharge

168.75

152

25704

... More
Code45 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc., complete as per specification I.S 3620/1979 Having compressive strength not less than 3.5 N/mm2 for saturated dry samples for superstructure in cm 1:6. For GF ---- as per Engineer Incharge

42

7565

317755.2

... More
Code46 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc., complete as per specification I.S 3620/1979 Having compressive strength not less than 3.5 N/mm2 for saturated dry samples for superstructure in cm 1:6. For FF ---- as per Engineer Incharge

35

7641

267444.1

... More
Code47 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- as per Engineer Incharge

160

285

45696

... More
Code48 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- as per Engineer Incharge

428.12

435

186450.5412

... More
Code49 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.1st Floor - Internal ---- as per Engineer Incharge

672.83

414

278565.0766

... More
Code50 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge..Ground Floor ---- as per Engineer Incharge

230

3194

734675.2

... More
Code51 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.1st Floor ---- as per Engineer Incharge

216

3226

696854.88

... More
Code52 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- as per Engineer Incharge

23

995

22900.64

... More
Code53 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete., complete. ---- as per Engineer Incharge

163

1238

201911.36

... More
Code54 - Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge., complete ---- as per Engineer Incharge

140

567

79497.6

... More
Code55 - Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface waterincluding of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- as per Engineer Incharge

1.72

1310

2253.888

... More
Code56 - Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- as per Engineer Incharge

497

188

93515.52

... More
Code57 - Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mm height with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size-1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ---- as per Engineer Incharge

67.57

5625

380132.6032

... More
Code58 - Providing Mathi/Nandi wood frames of doors, windows, clerestorywindows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete andside clamps ), but including cost of materials, labour, usage charges complete as per specifications.. ---- as per Engineer Incharge

0.4

139106

55642.496

... More
Code59 - Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) ---- as per Engineer Incharge

20.16

7724

155728.7424

... More
Code60 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- as per Engineer Incharge

298

123

36713.6

... More
Code61 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- as per Engineer Incharge

45.73

154

7068.0288

... More
Code62 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- as per Engineer Incharge

122.88

155

19129.9584

... More
Code63 - Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking to the appropriate disposal area as per direction of Engineer-in-charge ---- as per Engineer Incharge

1715.62

4

7685.9776

... More
Code64 - Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of 1m or part thereof beyond 10 m. ---- as per Engineer Incharge

3088.12

64

200604.2752

... More
Code65 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- as per Engineer Incharge

4910.69

126

621496.9264

... More
Code66 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ---- as per Engineer Incharge

524.13

636

333430.5408

... More
Code67 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- as per Engineer Incharge

176

632

111372.8

... More
Code68 - Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: ---- as per Engineer Incharge

11

9667

106346.24

... More
Code69 - Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g ---- as per Engineer Incharge

11

947

10422.72

... More
Code70 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- as per Engineer Incharge

190

271

51497.6

... More
Code71 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes ---- as per Engineer Incharge

130

356

46300.8

... More
Code72 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes ---- as per Engineer Incharge

95

600

57030.4

... More
Code73 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Providing and fixing rectangular high density polyethylene ---- as per Engineer Incharge

15000

10

151200

... More
Code74 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc., complete as per specification I.S 3620/1979 Having compressive strength not less than 3.5 N/mm2 for saturated dry samples for superstructure in cm 1:6. ---- as per Engineer Incharge

49.48

7293

360906.1304

... More
Code75 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- as per Engineer Incharge

23.98

1392

33392.3898

... More
Code76 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- as per Engineer Incharge

28.85

1406

40571.4665

... More
Code77 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- as per Engineer Incharge

180.56

272

49224.2672

... More
Code78 - Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modi fied cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge., complete ---- as per Engineer Incharge

14.27

573

8184.1304

... More
Code79 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm . ---- as per Engineer Incharge

164.14

1295

212597.4108

... More
Code80 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- as per Engineer Incharge

4.87

1005

4897.4668

... More
Code81 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete., complete. ---- as per Engineer Incharge

27.78

1251

34755.8358

... More
Code82 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ( ---- as per Engineer Incharge

0.71

154642

109796.4448

... More
Code83 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) ---- as per Engineer Incharge

11.98

6431

77043.8592

... More
Code84 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. - -do- 30 mm thick both side commercial ---- as per Engineer Incharge

11.58

3365

38973.648

... More
Code85 - Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- as per Engineer Incharge

19.41

356

6913.0656

... More
Code86 - Providing and fixing to existing door frames 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardent frade unsaturated polyster resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels confirming to IS:14856, including fixing to frames. ---- as per Engineer Incharge

14.58

3588

52320.0384

... More
Code87 - Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- as per Engineer Incharge

921.8

204

188932.128

... More
Code88 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- as per Engineer Incharge

3

6405

19215.84

... More
Code89 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- as per Engineer Incharge

170.12

196

33484.7196

... More
Code90 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (V-II, P.No 50, Sl.No.8.54.2 of PWD SR 2023-24)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- as per Engineer Incharge

733.05

112

82101.6

... More
Code91 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete- Gutter (600 mm over all girth) ---- as per Engineer Incharge

67.22

1202

80857.5936

... More
Code92 - White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap: ---- as per Engineer Incharge

9

2626

23637.6

... More
Code93 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete ---- as per Engineer Incharge

3

1366

4099.2

... More
Code94 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- as per Engineer Incharge

269

132

35551.04

... More
Code95 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc., complete as per specification I.S 3620/1979 Having compressive strength not less than 3.5 N/mm2 for saturated dry samples for superstructure in cm 1:6. For GF ---- as per Engineer Incharge

45

7221

324979.2

... More
Code96 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- as per Engineer Incharge

329

431

141864.8

... More
Code97 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge ---- as per Engineer Incharge

25.9

915

23699.536

... More
Code98 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm . ---- as per Engineer Incharge

163

234

38155.04

... More
Code99 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- as per Engineer Incharge

220

5967

1312819.2

... More
Code100 - Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. ---- as per Engineer Incharge

1

6986

6986.56

... More
Code101 - Providing and fixing brass stop cock of approved quality : 20 mm nominal bore ---- as per Engineer Incharge

6

341

2049.6

... More
Code102 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore ---- as per Engineer Incharge

8

614

4919.04

... More
Code103 - Providing and fixing 100 mm sand cast Iron grating for gully trap/ Nahani trap ---- as per Engineer Incharge

8

52

421.12

... More
Code104 - Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) ---- as per Engineer Incharge

543.92

1300

707270.0544

... More
Code105 - Providing, laying, spreading and compacting graded stoneaggregate to wet mix macadam specification including premixingthe Material with water at OMC in mechanical mix plant carriageof mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density ---- as per Engineer Incharge

483.45

2866

1385606.376

... More
Code106 - Providing and applying primer coat with SS1 grade BitumenEmulsion on prepared surface of granular base includingcleaning of road surface and spraying primer at the rate of 0.70kg/m2 using mechanical means.Sl. No.5.1-502 ---- as per Engineer Incharge

2544

45

116820.48

... More
Code107 - Providing and applying primer coat with SS1 grade BituminousEmulsion on prepared surface of granular Base including cleaningwith mechanical Broom of road surface and spraying primer at the rate of 0.90 kg/m2 using mechanical means ---- as per Engineer Incharge

2544

59

151011.84

... More
Code108 - Providing and laying Bituminous Macadam with 40/60 tphcapacity hot mix plant using crushed aggregates of specifiedgrading premixed with bituminous binder VG-30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction ---- as per Engineer Incharge

127.2

8357

1063066.368

... More
Code109 - Providing and laying Semi Dense Bituminous Concrete with40/60 TPH capacity hot mix plant batch type using crushedaggregates of specified grading premixed with bituminous binderVG-30 @ 5% by weight of mix and filler, transported to site,laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. ---- as per Engineer Incharge

63.6

11370

723147.264

... More
Code110 - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. ---- as per Engineer Incharge

3.05

1680

5124

... More
Code111 - Construction of un-reinforced plain cement concrete pavementusing RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. Thesuperplastisiser confirming to IS 9103-1999 Reaffirmed-2008,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately) Sl. No.6.6 P.No. 51/CSR 2023-24 VOL-3 ---- as per Engineer Incharge

101.85

7586

772723.728

... More
Code112 - Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test ---- as per Engineer Incharge

1

6081

6081.2

... More
Code113 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: ---- as per Engineer Incharge

50

346

17304

... More
Code114 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: ---- as per Engineer Incharge

50

433

21672

... More
Code115 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. PWD CSR 2023-24 Vol 5 P.No 139 I.No 12.2.3 ---- as per Engineer Incharge

25

2164

54124

... More
Code116 - roviding and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- as per Engineer Incharge

2

168

336

... More
Code117 - Providingand laying at site of work MS casing caps as per IS1239 (part II)1982 with all latest amendments if any for any dia.The thickness of plate used forcovering one ends hall be 3mm(minimum).The dimensions of caps and colarsshall be strictly as per IS 1239(Part-II)1982 with all amendments including cos of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- as per Engineer Incharge

2

183

367.36

... More
Code118 - Logging / scanning of borewell at any depth continuously with the help of Logger unit including the cost of transportation charges, crew charges, stationery charges and cost of consumables etc ---- as per Engineer Incharge

1

4114

4114.88

... More
Code119 - Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 7.50 HP - 120 LPM @ 132 m = 14 STG Outlet Dia - 2.00" ---- as per Engineer Incharge

1

38919

38919

... More
Code120 - Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete Medium Duty GI pipe of 32mm dia ---- as per Engineer Incharge

50

426

21336

... More
Code121 - Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendmentsSize 80 mm ---- as per Engineer Incharge

1

1960

1960

... More
Code122 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No.MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no for outdoor NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to15 HP pumps ---- as per Engineer Incharge

1

19600

19600

... More
Code123 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: 1.7 M010G PVC pipes 110mm dia., 6 kg/sqcm & class 3, ---- as per Engineer Incharge

115

460

52936.8

... More
Code124 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- as per Engineer Incharge

185

246

45584

... More
Code125 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- as per Engineer Incharge

4

6108

24433.92

... More
Code126 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN ---- as per Engineer Incharge

3

3088

9264

... More
Code127 - Supplying of TPST with rewirable porcelain channels in SM encloser made out of 14 SWG powder coated point of approved colour 63 amps ---- as per Engineer Incharge

1

4193

4193.93

... More
Code128 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ---- as per Engineer Incharge

1

515

515

... More
Code129 - Suppling fully automatic star delta starter unit push button type with suitable wires 2 conductors and adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts phase and wired after fixing to the existing wooden board for motor. Above 12.5 HP upto 25 HP ---- as per Engineer Incharge

1

8764

8764

... More
Code130 - Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motar up to 20 HP capacities. ---- as per Engineer Incharge

1

904

904.02

... More
Code131 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper conductor single core wire in open or concealed system of wiring as per IS 694:1990 & conforming to the attached GTP of group A. 4 sqmm ---- as per Engineer Incharge

870

63

54810

... More
Code132 - Supplying fixing and wiring heavy duty low voltage capacitors conforming to IS 2834 phase 400/440 volts grade, for power factor improvement of rotating machinery. ---- as per Engineer Incharge

4

480

1920

... More
Code133 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C cotouts and other equipments on the meter board using 40mm dia 2.90 thick GI pipe 2.5 mtr long buried in a pit… The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia ---- as per Engineer Incharge

1

3510

3510

... More
Code134 - Supplying and fixing porcelain fuse channel with cut out on the existing wooden block and wiring complete 63 amps ---- as per Engineer Incharge

3

401

1203

... More
Code135 - DistributionTransformer-3Phase,11kV/433V-StackedCRGOCorewithOilasperIS-1180 (Part-1): 2014 100 kVA, Aluminium Wdg, Star 2 (5 Star) (PWD Escom SR 2023-24,p- 7,It-12.06) ---- as per Engineer Incharge

1

221952

221952

... More
Code136 - Erectionof Transformer&StructuresErectionof 100kVATransformer-LabourCost (PWD Escom SR 2023-24,p- 46,It-12.06 ---- as per Engineer Incharge

1

1590

1590

... More
Code137 - DP Transformer Structure using RCC Pole - 9 Mtr Long, 145 Kg WL ---- as per Engineer Incharge

1

17402

17402

... More
Code138 - Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet.Short point upto 3mtr form tapping point to out let via switch ---- as per Engineer Incharge

30

269

8070

... More
Code139 - Medium point above 3Mtr upto 6mtr from tapping point to outlet via switch ---- as per Engineer Incharge

65

379

24635

... More
Code140 - Long point above 6 mtr upto 10mtr from tapping point to out let via switch ---- as per Engineer Incharge

70

555

38850

... More
Code141 - Two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switches ---- as per Engineer Incharge

25

677

16925

... More
Code142 - Open Conduit System : Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.. 19/20mm dia 2mm thick ---- as per Engineer Incharge

1000

69

69000

... More
Code143 - Open Conduit System : Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.. 25mm dia 2mm thick ---- as per Engineer Incharge

750

81

60750

... More
Code144 - Open Conduit System : Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.. 32mm dia 2mm thick ---- as per Engineer Incharge

165

106

17490

... More
Code145 - Groove cutting :Supplying...dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 19/20mm dia 2mm thick ---- as per Engineer Incharge

250

68

17000

... More
Code146 - Groove cutting :Supplying...dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 25mm dia 2m thick ---- as per Engineer Incharge

300

79

23700

... More
Code147 - Groove cutting :Supplying...dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 32mm dia 2.5mm thick ---- as per Engineer Incharge

100

99

9900

... More
Code148 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 1.5 sqmm ---- as per Engineer Incharge

650

26

16900

... More
Code149 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 2.5 sqmm ---- as per Engineer Incharge

1400

42

58800

... More
Code150 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 6 sqmm ---- as per Engineer Incharge

780

92

71760

... More
Code151 - Fan Box / Hook Supplying and fixing of Metal Fan Box with Round Hook. ( ---- as per Engineer Incharge

60

160

9600

... More
Code152 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall1 - 3 Way ---- as per Engineer Incharge

85

138

11730

... More
Code153 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall4 - 5 Way ---- as per Engineer Incharge

3

159

477

... More
Code154 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall6 Way ( ---- as per Engineer Incharge

21

220

4620

... More
Code155 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall8 Way ---- as per Engineer Incharge

9

261

2349

... More
Code156 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall10-12 Way ---- as per Engineer Incharge

16

319

5104

... More
Code157 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall16way ---- as per Engineer Incharge

17

363

6171

... More
Code158 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- as per Engineer Incharge

85

161

13685

... More
Code159 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- as per Engineer Incharge

3

175

525

... More
Code160 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ( ---- as per Engineer Incharge

21

234

4914

... More
Code161 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- as per Engineer Incharge

8

284

2272

... More
Code162 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- as per Engineer Incharge

13

344

4472

... More
Code163 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16 Module ---- as per Engineer Incharge

17

397

6749

... More
Code164 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.6A one way ---- as per Engineer Incharge

250

102

25500

... More
Code165 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.6A two way ---- as per Engineer Incharge

5

166

830

... More
Code166 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.6A three way socket. ---- as per Engineer Incharge

50

171

8550

... More
Code167 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.Stepped Fan Regulator. ---- as per Engineer Incharge

60

357

21420

... More
Code168 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.16A one way switch. ---- as per Engineer Incharge

11

180

1980

... More
Code169 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.6A Bell Push. ---- as per Engineer Incharge

3

177

531

... More
Code170 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.32A DP switch . ---- as per Engineer Incharge

2

326

652

... More
Code171 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.6/16A Universal Socket ---- as per Engineer Incharge

11

236

2596

... More
Code172 - Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898.5 - 32 Amps SP ---- as per Engineer Incharge

31

415

12865

... More
Code173 - Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898.6-32 Amps DP ---- as per Engineer Incharge

4

739

2956

... More
Code174 - Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898.16-25A,2P,RCCB ---- as per Engineer Incharge

3

4277

12831

... More
Code175 - Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure.16 way SP &N ---- as per Engineer Incharge

3

2932

8796

... More
Code176 - Supplying….mm dia 2mm 2.5mm thick heavy gauge PVC conduit pipe with suitable size bends, metal/ PVC junction boxes adhesive paste etc : 19/20mm dia 2mm thick ---- as per Engineer Incharge

400

66

26400

... More
Code177 - Supplying….mm dia 2mm 2.5mm thick heavy gauge PVC conduit pipe with suitable size bends, metal/ PVC junction boxes adhesive paste etc : 25mm dia 2mm thick ---- as per Engineer Incharge

200

78

15600

... More
Code178 - Fixing all types and all capacities of flouroscent / false ceiling / spot light / CFL / LED fittings on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required nos. of round blocks & clamps. On wall / ceiling / rafter / girders. ---- as per Engineer Incharge

100

122

12200

... More
Code179 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- as per Engineer Incharge

41

171

7011

... More
Code180 - Supplying fixing andwiring earth electrode for groundingof lifts, transformers,DGsetsetc.using40mmdia2.9mmthick2.5mlongGI pipewithGIfunnelwithmeshandsuitablesizereducer fixedonthetop of the earth electrode.The funnel should be enclosed in aCC chamber of 400x400x400mmwith a cast iron cover. The earthelectrodeshall havestaggeredholesof12mmdiaand theelectrode shouldbecovered150mmall-roundwithalternatelayersofsaltandcharcoalfromthebottomoftheCCchamber.Theconnectionfromthe electrode is to be established through GI strip using GI bolts and nuts ---- as per Engineer Incharge

3

4256

12768

... More
Code181 - Supplying and running of GI/copper strips for grounding connections using necessary fixing materials as required. 8 SWG copper wire ---- as per Engineer Incharge

140

128

17920

... More
Code182 - Supplying ---- feet --- PVC batten with integrated LED tube ---- watt with high quality deffuser with life of 25000 burning hours &70% lumen maintenence with CRI .2 year warranty againest any manufacturing defect - LED light fitting 1 x4' -36 watt industrial type Decorative Slim Linear LED Batten of 1150 mm length : 36 watt, (Philips -mirolta pro 36watt or equivalent)-( ---- as per Engineer Incharge

19

1269

24111

... More
Code183 - Supplying 48" Sweep (1200mm)capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles, Single phase AC supply conforming ot ISS-374-1979 and with double ball bearing system. ( Havells Or Equivalent) ---- as per Engineer Incharge

51

2984

152184

... More
Code184 - Supply of round/square recess/surface mounted rolling typeLEDDown light with ......WGU10 LEDLampRibFabricated from diecast aluminium with white powder coatedprewired tomainsconnector&hasswivellingunitofaluminiumdiecasteyeball &LEDLamppositionretainedbycircularwirespring,withLifeof25000 burning hours&70%lumenmaintenance withCRI greated than 80. PowerInput:220-240V@50/60Hz&Powerfactor greater than 0.9alongwithCEapproved. 2yearsWarrantyagainstanymanufacturingdefectworking under standard electrical condition LED square or round down light 15-18W( Philips or equivalent ---- as per Engineer Incharge

30

1324

39720

... More
Code185 - Supplying of recess mounting non integral type ........ LEDwluminairecomprising of pressuredecast/extrudedaluminiumhousing,withspringloadedfalseceilingclamps,PowerLEDswithCCT6500degreeK,CRI greater than 70%. efficacygreater than 100lumenper W,120degree beamspread, lifegreater than 25000burninghoursandCompliance toIS10322/IEC60598, LM79&LM80. Thelampcompartment isenclosedwithanti glareopal diffuserwhichenhances the lighting level LEDsaredrivenbyHFelectronicdriver integrated inaseparatecontrolgea assembly., withPFgreater than 0.95, power loss should Less than 5%of lampWage.,shortcircuit&opencircuitprotectiontobeintegrated inthecircuit,THDles than20%,LifeasperLM79. Theoperatinginputvoltageshouldbebetween130 to 275 V. BISApproved andTestedby NABL/CPRI accredited laboratory with2yearsWarranty againstany manufacturing defect working under standard electrical condition. LED Modular recess mounted panel type light 2'x2' - 34-36watt ( Philips or equivalent ) ---- as per Engineer Incharge

33

5898

194634

... More
Code186 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.TV/Telephone Socket ---- as per Engineer Incharge

11

156

1716

... More
Code187 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293.TV RJ45/I.O Outlet Cat-6 ---- as per Engineer Incharge

2

337

674

... More
Code188 - Supplyingand drawingPVCflexible onepair telephoneunarmoured tinned copper cable. 2Pair ---- as per Engineer Incharge

100

15

1500

... More
Code189 - Supplying and drawing UTP-CAT 6E LAN cable ---- as per Engineer Incharge

2

38

76

... More
Code190 - Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and coloring to match the existing wall or brackets with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame if required. ---- as per Engineer Incharge

8

707

5656

... More
Code191 - Supplying ---- feet --- PVC batten with integrated LED tube ---- watt with high quality deffuser with life of 25000 burning hours &70% lumen maintenence with CRI .2 year warranty againest any manufacturing defect - LED light fitting LEDlight fitting1x2'- 9/10watt- (Philips or equivalent) ---- as per Engineer Incharge

9

551

4959

... More
Code192 - Supplyingexhaust fanof1440RPMof450mm(15")sizewithbracketbladescompleteforheavy dutysuitableforoperateon230V50Hz,ACsupply. (HavellsOrEquivalent) ---- as per Engineer Incharge

8

4446

35568

... More
Code193 - Two outlet in a row, above 10mtr from tapping point to out let via switches ---- as per Engineer Incharge

10

989

9890

... More
Code194 - Deep Junction Box19/20mm deep junction box ---- as per Engineer Incharge

10

49

490

... More
Code195 - Deep Junction Box 25mm deep junction box ---- as per Engineer Incharge

10

51

510

... More
Code196 - Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. 8 way TP & N 6 way TP & N ---- as per Engineer Incharge

2

4940

9880

... More
Code197 - Fixing all types and Fixing halegen/LED/MH/svl/il/led FLOOD LIGHT FITTING on existing Pole /wall ceiling including lamps ,blts,nuts and wiring usiing suitable capacity wires ---- as per Engineer Incharge

4

162

648



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.