Directorate Of Municipal Administration Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Directorate Of Municipal Administration - DMA Tender
Civil And Construction
Excavation
Opening Date23 Aug 2024
Closing Date9 Sep 2024
Tender Amount₹ 14,00,000
Costs
EMD
₹ 35,000Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/EL/WORK_INDENT27630Bid Award Id
ViewTender No
DMA/2024-25/EL/WORK_INDENT27630Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
cmc04 - Insulator (1.1 kV Ceramic Pin Insulator With GI pin
70
66
4620
cmc05 - No. 8 Strain Insulator
40
27
1080
cmc06 - Rabbit ACSR Conductor
3
47621
142863.06
cmc07 - Guy set with No. 15 Strain Insulator & Concreting materials as per Dwg
5
1170
5850
cmc08 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)
0.025
862666
21566.65
cmc09 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm)
0.065
691218
44929.17
cmc10 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm)
0.08
317912
25432.96
cmc11 - poxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable3.5 x 225/240/300 Sqmm (sl no 35.04 page no 445 ESCOMS SR 2023-24 Rates ) (240 SQ MM Out Door Pot head LT) (240 SQ MM IN Door Pot head LT)
3
588
1764
cmc12 - poxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable3.5 x 225/240/300 Sqmm (sl no 35.04 page no 445 ESCOMS SR 2023-24 Rates ) (185 SQ MM Out Door Pot head LT ) (185 SQ MM IN Door Pot head LT )
4
480
1920
cmc13 - Heavy Duty Long Barrel Copper Lug - 240 Sqmm (240 SQ MM Copper Lugs )
8
355
2840
cmc14 - Heavy Duty Long Barrel Copper Lug - 240 Sqmm (185 SQ MM Copper Lugs )
8
274
2192
cmc15 - Heavy Duty Long Barrel Copper Lug - 240 Sqmm (70 SQ MM Copper Lugs )
32
89
2848
cmc16 - Earthing materials pipe type for grounding as per Drawing No. BESCOM/GM/CP/15 & 34/
4
1729
6916
cmc17 - Heavy Duty Long Barrel Copper Lug - 240 Sqmm (70 SQ MM Copper Lugs )
32
89
2848
cmc18 - AC Distribution Box Single front (Outdoor type) 6 Terminal one I/C of 100A MCCB 20kA + 6 O/G MCB 16A + 1 O/G of 100A, HRC fuse, complete as per technical specification
1
43560
43560
cmc19 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.400-500 A 50 kA
1
41497
41497
cmc20 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.200 A 25kA
2
17301
34602
cmc21 - Fixing foundation frame of channels and angle iron welding fixing in concrete aligning the RMU on foundation bed, assembly of units, connecting Bus Bars from panel to panel initial filling of oil etc., complete.5 Panel
1
23354
23354
cmc22 - Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick
3960
81
320760
cmc23 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 04mm
860
63
54180
cmc24 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5mm
1280
42
53760
cmc25 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5mm
920
26
23920
cmc26 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.mm
680
19
12920
cmc27 - Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854
138
131
18193.92
cmc28 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring
10
171
1710
cmc29 - Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP
10
802
8020
cmc30 - Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube1 x 4' Tube light fitting
90
269
24210
cmc31 - Supplying and fixing/replacing of fluorescent tube
90
95
8550
cmc32 - 1.1 KV Class HR (Heat Resistant) PVC Insulated & UnSheathed Aluminium Wires Multistrand Single Core Lead wires as per IS694: 2010
3
3542
10626
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements