Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction
Building Construction
Opening Date16 Dec 2024
Closing Soon1 Jan 2025
Tender Amount₹ 32,49,350.21 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(PWD DSR 2023-24, Volume-I Page No. 9, Item No. 5.2)

6.97

6948

48433.833

... More
005 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.( PWD DSR 2023-24 Volume-II Page No. 7 Item No. 1.9)

64.91

279

18129.363

... More
006 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PWD DSR 2023-24 Volume-I Page No. 9 Item No. 2.2.1

8.86

6601

58487.961

... More
007 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD DSR 2023-24 Volume-I Page No. 9 Item No. 2.3.1

8.08

6639

53644.332

... More
008 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD DSR 2023-24 Volume-I Page No. 9 Item No. 2.5.1

27.4

6961

190745.1

... More
009 - Form work Foundation upto Plinth(Isolated)(PWD DSR 2021-22 Volume-I Page No. 111 Item No.1(a) 8% OF CONCRETE RATE)

8.86

528

4679.0546

... More
010 - Form work Foundation uptoPlinth Beams of Buildings and RCC Roof Slabs (PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 50% OF CONCRETE RATE)

8.08

3319

26822.2064

... More
011 - Form work Foundation upto RCC Roof Slabs (PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 50% OF CONCRETE RATE)

14.81

3480

51549.9075

... More
012 - Form work Foundation uptoRCC Beams, Lintels & Troughs of Aqueducts(PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 50% OF CONCRETE RATE)

6.42

4176

26815.698

... More
013 - Form work Foundation uptoRCC Columns / Shaft (Slip Centering)(PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 70% OF CONCRETE RATE)

5.51

4873

26850.5055

... More
014 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (All other type of structures).PWD DSR 2023-24 Volume-I Page No. 18, Item No. 2.11h

3.694

93929

346976.8659

... More
015 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(PWD DSR 2023-24 Volume-II Page No. 13 Item No. 6.2

33.57

8376

281212.533

... More
016 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-24 Volume-II Page No.41,Item No. 8.2.1)

485.55

309

150399.1125

... More
017 - Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-24 Volume-II Page No.44,Item No. 8.19.1)

18.4

267

4926.6

... More
018 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.(PWD DSR 2023-24 Volume-II Page No.44,Item No. 8.19.1)

67.6

1231

83259.54

... More
019 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(PWD DSR 2023-24 Volume-II Page No.44,Item No. 8.19.1)

172.02

27

4696.146

... More
020 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-24 Volume-II Page No.44,Item No.8.25)

172.02

143

24745.077

... More
021 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.(PWD DSR 2023-24 Volume-II Page No.86,Item No.8.25)

194.04

192

37284.786

... More
022 - Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)(PWD DSR 2023-24 Volume-II Page No.100,Item No.12.15)

2.25

7241

16294.1625

... More
023 - Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.(PWD DSR 2023-24 Volume-II Page No.99,Item No.12.12)

0.216

130412

28169.0136

... More
024 - PVC liner material(including import duty ,freight charges) PVC pipe - OD 32mm and 10 Kg/sqcm

40

34

1386

... More
025 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD CSR 2023-24, Vol-II, P. No. 123, I. No. 13.34

1500

9

14175

... More
026 - SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.PWD ELE CSR 2023-24, Vol-VI, P. No.105, I. No.1.1.1

40

72

2898

... More
027 - Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall(PWD ELE CSR 2023-24, Vol-VI, P. No.105, I. No.1.1.1)

40

144

5796

... More
028 - Supplyingandflushmountingteakwoodenboxwithoutfrontplank,madeofnotlessthan12mmthickwood,afterduegroovecutting,finishing with necessary cement plastering complete.12" x 12" x 3" (300 x 300 x 76 mm) PWD ELE 2023-24 pg no 3 of 105, It no 1.6.1

8

126

1008

... More
029 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.PWD ELE 2021-22 pg no 2 It no 2.1.1

10

289

2898

... More
030 - Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch. (PWD ELE 2023-24 pg no 3 of 105, It no 2.1.2)

4

413

1654.8

... More
031 - C)Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch.(PWD ELE 2023-24 pg no 3 of 105, It no 2.1.2)

4

598

2394

... More
032 - Supplyingandfixinghylumplasticsheet3mmthickwithnecessarynitchesforfixingswitches,regulatorsetc.,andfixingonexistingwood or metal box using N. F. screws.(PWD ELE 2023-24 pg no 3 of 105, It no 3.9)

1000

-

370

... More
033 - Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.6A Two Way Switch.(PWD ELE 2023-24 pg no 3 of 105, It no3.14.2)

4

73

294

... More
034 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 6-32 A TPN PWD ELE 2021-22 pg no 13 It no 5.17.7

4

1865

7463.4

... More
035 - SupplyingofCeilingFanwithCapacitorratingAsperguidelineofBEE5starratingandIS:374/19andalsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Ratedpowerupto35W+/10%,RatedcurrentAsperIS:374/19,Ratedpowerfactor0.9lagging(min),Ratedspeed350+/10%RPM,Ratedairdelivery210+/10%CubicMeterMinimum,Ratedservicevalue6.2CMM/W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet,ClassBmotorinsulation,BearingTwoballbearings,Top6202,Bottom6201,asperISspecification,Motorwinding.TempriseShallnotexceed75degCoverandambientof400Cbyresistancemethodat245V,InsulationresistanceShallnotbelessthanTwoMegaOhms(2MOhms),LeakagecurrentShouldnotexceed210MicroAmp,Powerinput,W¤t,AirDelivery&FanSpeedasperIS:374/2019withlatestamendment,2yearmanufacturerWarranty.(BLDC fans)48" Sweep 5 Star (1200 mm)(PWD ELE 2023-24 pg no 3 of 105, It no3.14.2)

4

2810

11243.4

... More
036 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring PWD ELE 2021-22 pg no 23 It no 6.4

4

170

680.4

... More
037 - Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps.On wall/ ceiling / Rafter / Girders(PWD ELE 2023-24 pg no 3 of 105, It no3.14.2)

4

128

512.4

... More
038 - Supplyandfixingpolishedwoodboardmadeofnotlessthan15mmthickplankonbothsidesofnotmorethan2piecesandfixingthesametothewallusingtaperedinvertedwoodenplugsscrews.12" x 12" x 2"(PWD ELE 2023-24 pg no 14 of 105, It no 5.6.4)

2

190

380.1

... More
039 - Supplying and fixing of porcelain fuse channel with cut out 16 Amps on existing wooden/panel using necessary nuts, bolts, and washers etc complee (32/3)(PWD ELE 2023-24 pg no 62 of 105, It no 14.04)

5

144

724.5

... More
040 - SupplyingofSwitchdisconnectorfuseunit(TPN)HRCtype(butwithout HRC fuses). With AC-23A duty and as per IS- 13947.63 A(PWD ELE 2023-24 pg no 15 of 105, It no 5.8.1)

1

2427

2427.6

... More
041 - SupplyofLEDpolemountingtypeposttoplanternwithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonate/clearglassmaterial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hr at LumenMaintenanceof70,CCT5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireIK08.PowerFactor0.9withmains,SurgeProtectionMin5KValongwithOvervoltageOverload,shortcircuitmisswiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V5060Hzapplication.CompliancetoIS10322/1EC60598,LM79LM80AdherencewithRoHS.ULapprovedMCPCBLEDEfficiency1301m w,nominalCRI75.LuminairemanufacturershouldhaveinhousefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/BodypartWarrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osrammake LED Source.LED Post Top Lantern with 25/30 W(PWD ELE 2023-24 pg no 45 of 105, It no11.7.2)

1

8108

8108.1

... More
042 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) PWD CSR 2023-24, Vol-II, P. No. 46, I. No. 8.33.1

313.53

165

52014.627

... More
043 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. PWD CSR 2023-24, Vol-II, P. No. 60, I. No. 9.10

99.53

1161

115584.189

... More
044 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. PWD CSR 2023-24, Vol-II, P. No. 63, I. No. 9.24

1.56

2994

4671.576

... More
044 - Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (0.1 mm) wall thickness and 3 nos.stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section PWD CSR 2023-24, Vol-II, P. No. 108, I.No.12.83.2

75

250

18821.25

... More
046 - Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) PWD CSR 2023-24, Vol-II, P. No. 111, I. No. 12.92

23.94

6557

156980.565

... More
047 - Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) PWD CSR 2023-24, Vol-II, P. No. 108, I. No. 12.84

1.8

5173

9312.642

... More
048 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) PWD CSR 2023-24, Vol-II, P. No. 109, I. No. 12.85

1.62

6004

9728.019

... More
049 - Water proofing materials PWD CSR 2023-24, Vol-II, P. No.A-43 I. No.1028

50

46

2310

... More
050 - Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length, 20mm NB PWD CSR 2023-24, Vol-II, P. No. 118, I. No. 13.8.2.2

12

115

1386

... More
051 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.32.3 25 mm nominal dia pipes

30

500

15025.5

... More
052 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.33.4 32 mm nominal dia Pipes

20

390

7812

... More
053 - Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A, including jointing with seal ring conforming to IS 5382, leaving 10mm gap for thermal expansion, (i) single socketed pipes 100 mm diameter PWD CSR 2023-24, Vol-II, P. No. 125, I. No. 13.48

40

305

12222

... More
054 - Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete PWD CSR 2023-24, Vol-II, P. No. 127, I. No. 13.59

12

226

2719.2

... More
055 - Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge Orissa pattern W.C Pan of size 580x440 mm (PWD CSR 2023-24, Vol-II, P. No. 202, I. No. 20.44.2)

12

3653

43840.92

... More
056 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD CSR 2023-24, Vol-II, P. No. 132, I. No. 14.7.1

2

3236

6472.2

... More
057 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm (PWD CSR 2023-24, Vol-II, P. No. 136, I. No. 14.32.4)

2

1812

3624.6

... More
058 - Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Economy Class PWD CSR 2023-24, Vol-II, P. No. 139, I. No. 14.55a

14

1150

16107.14

... More
059 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from theexcavationetc. complete. 6 Kg/m2: 200mm(weight of pipe -6.233 kg) (p.no.120. it.no 10.14.14) 2023-24 WATER SUPPLY AND UGD WORKS COMMON SCHEDULE OF RATES VOLUME-V

40

1015

40614

... More
060 - Concealed PVC Conduit System Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2mm thick (P.no.2.it.no.1.1.1) (PWD CSR for Electrical Works for the Year 2023-24)

70

72

5071.5

... More
061 - PVC/metal conduit Deep Junction Box Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box (P.no.2.it.no.1.5) (PWD CSR for Electrical Works for the Year 2023-24)

10

51

514.5

... More
062 - Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8" x 6" x 3" (203 x 152 x 76 mm) (P.no.3.it.no.1.6.4) (PWD CSR for Electrical Works for the Year 2023-24)

6

90

541.8

... More
063 - Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 4" x 4" x 3" ( 101 x 101 x 76 mm) (P.no.3.it.no.1.6.6) (PWD CSR for Electrical Works for the Year 2023-24)

24

77

1864.8

... More
064 - Wiring for Lightings/Power Circuit Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 Sqmm (P.no.5.it.no.2.3.2) (PWD CSR for Electrical Works for the Year 2023-24)

250

27

6825

... More
065 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmm (P.no.5.it.no.2.3.3) (PWD CSR for Electrical Works for the Year 2023-24)

200

44

8820

... More
066 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 Sqmm (P.no.5.it.no.2.3.4) (PWD CSR for Electrical Works for the Year 2023-24)

125

66

8268.75

... More
067 - Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way (P.no.9.it.no.3.6.1) (PWD CSR for Electrical Works for the Year 2023-24)

14

107

1499.4

... More
068 - Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps two way. (P.no.9.it.no.3.6.2) (PWD CSR for Electrical Works for the Year 2023-24)

4

166

664

... More
069 - Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch (P.no.9.it.no.3.6.7) .(PWD CSR for Electrical Works for the Year 2023-24)

5

189

945

... More
070 - Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch. (P.no.9.it.no.3.6.9) (PWD CSR for Electrical Works for the Year 2023-24)

4

342

1369.2

... More
071 - 4mm Thick Plastic Sheets Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. (P.no.9.it.no.3.8) (PWD CSR for Electrical Works for the Year 2023-24)

200

-

86

... More
072 - Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps (P.no.10.it.no.5.7.2) (PWD CSR for Electrical Works for the Year 2023-24)

2

253

506.1

... More
073 - Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (p.no.17.it.no.5.18.1) (PWD CSR for Electrical Works for the Year 2023-24)

2

435

871.5

... More
074 - Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP .(p.no.17.it.no.5.18.4) (PWD CSR for Electrical Works for the Year 2023-24)

2

775

1551.9

... More
075 - MCB Distribution Boards Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door 8 Way SP & N (p.no.18.it.no.5.19.3)(PWD CSR for Electrical Works for the Year 2023-24)

2

1566

3133.2

... More
076 - PVC Batten with LED Tubes Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 5060Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4- 20/22 w (p.no.43.it.no.11.3.2) (PWD CSR for Electrical Works for the Year 2023-24)

12

724

8694

... More
077 - LED Down Lights Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 5060Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W (p.no.43.it.no.11.5.3) (PWD CSR for Electrical Works for the Year 2023-24)

2

1390

2780.4

... More
078 - Lamp Holder Supplying & Fixing of 70-150 Watts lamp holder 2 Pin (p.no.52.it.no.12.46) (PWD CSR for Electrical Works for the Year 2023-24)

12

66

793.8

... More
079 - Fixing all type of Luminaries Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders (p.no.56.it.no.13.7.1) (PWD CSR for Electrical Works for the Year 2023-24)

4

128

512.4

... More
080 - Fixing of LED Lights Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.(p.no.58.it.no.13.19) (PWD CSR for Electrical Works for the Year 2023-24)

2

514

1029

... More
081 - Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply. (PWD CSR for Electrical Works for the Year 2023-24 P.no.30.it.no.6.1)

1

1492

1492

... More
082 - Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewholecurrentclass-1AccuracyEnergyMeter. (PWD CSR for Electrical Works for the Year 2023-24 P.no.30.it.no.5.35)

1

5705

5705

... More
083 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (All other type of structures).PWD DSR 2023-24 Volume-I Page No. 18, Item No. 2.11h

0.494

82961

40983.0057

... More
084 - Fabrication,Supplying,Erection,TestingandCommissioningof.mslongPolygonhighmastwithSingle/Multipletelescopicsectionshaving,(minimumoverlapdistanceof1.5timesoftopsection)thicknessasperBSEN10025grades355JO/ASTMA57250steelsheetplateforshaftsuitabletowithstandawindvelocityof47m/sasperIS875part3(asperGADrawing).BaseplateasperIS2062/ASTMA57250.ThemastshallbeGalvanizedinsingleHotdipasperBSENISO1461/ASTMA123withanaverage70micronsasperIS2629,andweldedasperBS5135SingleLSeamjointThemastshallhave2WayheadframewithdiecastLM6pulleys,stainlesssteelaxle,PhosphorusBronzebearingbushpressfittedwithseparateguidesfor2runsof5mmdia,stainlesssteelwireropeofAISI304grade7/19core,(FactorofSafetyasperTRno7).2.5mm2EPRinsulatedPCPsheathedtrailingpowercablehousedinsidethebottomshaftofmastwithdoorhavinglockingarrangementThemastshallhavemanual/powertool(Suitablereversiblegearedmotoroperatingon230/415V,50Hz,shallbeprovideabove15Mtrmast)Themastshallhavelanternof2segments,suitablediawithmaxloadcarryingcapacityasperIS1239.ThemastshallbeerectedonexistingRCCfooting.Themastshallbesuppliedwith3mmthicktemplate,lightningarresterof1.2mlengthgalvanizedpipewithtoparrowfittedontopoftheheadframecoverandGLStypeaviationtwinlAfittingwithwiringcomplete.(excludingfoundation)asper technical data.12 m/12.5 m - Top 100 mm and Bottom 310 mm dia (PWD ELE SR 2023-24 Volume-VI Page No. 13 OF 105, Item No. 4.5.1

2

137550

275100

... More
085 - SupplyofLEDfloodlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonate/clearglassmaterial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hr@LumenMaintenanceof70,CCT5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireIK08.PowerFactor0.9withmains,SurgeProtectionMin5KValongwithOvervoltage/Overload,shortcircuit/misswiringprotection.Compatibleforpolemaulingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM80AdherencewithRoHS.ULapprovedMCPCB.Topaccessstreetlightwithsinglescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.WSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI75.LuminairemanufacturershouldhaveinhousefacilityaccreditedbyNABLCPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngravedEmbossingonthediecasthousing/BodypartWarrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osrammake LED Source.LED Floodlight 200W(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 11.9.6

16

19510

312160.8

... More
086 - Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires.(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 13.5

16

170

2720

... More
087 - Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.3.5x6 Sqm(PWD SR 2023-24 Volume-V Page No. 46 OF 105, Item No. 13.38.1)

60

393

23625

... More
088 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm dia(PWD SR 2023-24 Volume-V Page No.95 , Item No. 9.1.1)

80

198

15876

... More
089 - SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS81301984and(Virgin)PVCinsulationsheathedsuitableforworking voltage upto 1100 Volts as per IS-694:1990,3C x 2.5 mm2(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 2.5.8

60

118

7119

... More
090 - SupplyingandfixingMicroprocessorbasedElectronictimer(withoutcontactor,DinMountingusingnecessarybolts,nutsandwashersetc.,.)3-120sec setting.(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 5.47)

2

2430

4861.5

... More
091 - Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.(PWD SR 2023-24 Volume-V Page No.157 , Item No. 13.39)

2

3937

7875

... More
092 - FabricatingsupplyingandmountingMSboxmadeout.SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete.14 SWG(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 5.42.1)

4000

-

2120

... More
093 - SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm.(PWD ELE SR 2023-24 Volume-VI Page No. 20 OF 105, Item No. 5.41.2)

60

414

24885

... More
094 - Supplying.Arated3phasewithneutralbusbarusingrequiredcapacityelectrolyticaluminiumstripscoveredwithheatshrinkablecolouredPVCsleeve,mountedonphenolic/FRP/DMCinsulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete100 A 4 x 30 x 6 mm Aluminium Strips.(PWD ELE SR 2023-24 Volume-VI Page No. 20 OF 105, Item No. 5.40.1)

2

2588

5176.5

... More
095 - SupplyingandfixingregularMCCBdistributionPanelconfirmingtoIS/IEC61439-3andIK09testedasperIS/IEC62262withminimumIP43protectionprovidedwithPolyurethane(PUR)gasket,withsuitableearthingsystem,onwall/woodboard/flushmountingusingrequiredclA,bolts,nuts,etc.,withprovisionforfixingofsuitabletypecapacityMCCB'sasanincomerfor3phaseDoubledoorwithnecessarybusbarcompletelywiredtouseon440V3phase4wirepowdercoatedpaintingetc.,completewithaprovisionforfixingofsingle/threephasesuitablecapacityMCB'sasoutgoingsconfirmingtoIS/IEC 60898 - 2.4 Way(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.5.17.1)

2

10845

21690.9

... More
096 - Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.95/100 A(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.5.17.1)

2

17436

34872.6

... More
097 - Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers. 320 A Page No. 10 Item No.5.7.6 Electrical SR 2021-22

2

1934

3868.2

... More
098 - SupplyingofmultifunctiondigitalmeterwiththreelinebacklightLCDtypedisplayforvoltage,Current,frequency,Power,powerfactor,kVA,kWH,kVARsuitablefor3phase,4wireLTnetworkwithIP54degreeofprotectionandcompletelywiredasrequiredwithcommunication Port and Class 0.5s accuracy.(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.5.33)

2

9780

19561.5

... More
099 - SupplyingandFixing.mmdiaclampsssAGIpipebracketupto2.7meterslongterminatedwithareducingcollarof40x25mmtowhichextrapipeof175mmlengthisfixedforfixingMV/SV/MH/FTLstreetlightfittingofallcapacitiesonrail/RCC/wall/tubularpole,usingsuitableclamps,bolts,nutsandwiringusingsuitablecapacitywires. Using 32mm dia G.I.Pipe(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.13.2.2)

16

1359

21756

... More
100 - GESCOM Deposit and Service Charegs for Power Connection

1

15000

15000

... More
101 - Providing half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in cement mortar 1:3 (1 Cement : 3 coarse sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10cm / 11.4 cm wide bitumen felt type 3 grade 1 including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.PWD CSR 2023-24, Vol-II, P. No. 13, I. No. 6.29

18.9

360

6806.835



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.