Directorate Of Municipal Administration Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 7,825Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/OW/WORK_INDENT19916Bid Award Id
ViewTender No
DMA/2024-25/OW/WORK_INDENT19916Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
code04 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). CSR 2023-24 Sl. No.5.4, Page No.9Volume2.
10.66
6580
70149.9422
... More
code05 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. CSR 2023-24 Sl. No.1.10, Page No.7 Volume1.
13.944
164
2297.9712
... More
code06 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. CSR 2023-24 I NO 6.32 P 17 V -2
5.271
1349
7112.1603
... More
code07 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 Sl. No.8.5.1, Page No.42 Volume2.
24.5999
376
9273.670302
... More
code08 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement
: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.CSR2023-24 I NO 9.9 Page No.60, V-2
6.72
1108
7447.6416
... More
code09 - Providing and fixing Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer ,including welding and bolted with special shaped washers etc.complete. Hot finished welded type tubes including cost of materials, labour , usage charges of machinery complete as per specifications and as per directions oft he Engineer-in-Charge.CSR 2023-24 si no 11.16.1 pg 89 vol 2
550
112
61748.5
... More
code10 - Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation asapproved byEngineer-in-charge)0.50mm(+0.05%)total coated thickness with zinc coating 120gram sperm 2 asper IS:277,in240m pa steel grade,5-7microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns. Sheet shouldhave protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12m or as desired by Engineer-in-charge. The sheet shall be fixed usingself drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cuttingtosize andshape whereverrequired..CSR 2023-24 si no 7.38 pg 26 vol 2
27.5
572
15748.7
... More
code11 - Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. CSR 2023-24 I No.8.30, Page No.46 Volume2.
26.65
179
4776.213
... More
code12 - Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.2.1, VOL-6, 19/20 mm dia 2 mm thick,
15
67
1019.7
... More
code13 - Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, IN-CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.2.2, PN-2, VOL-6, 25 mm dia 2 mm thick,
15
80
1205.1
... More
code14 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.3.1, PN-2, VOL-6, 19/20 mm dia 2 mm thick
2
70
140.08
... More
code15 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-1.3.2, PN-2, 25 mm dia 2 mm thick
4
81
325.48
... More
code16 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.1.1, PN-5, Vol-6, Short point upto 3m from tapping point to out let via switch box.
1
293
293.55
... More
code17 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, in-2.1.2, pn-5, vol-6, Medium point above 3m upto 6m from tapping point to out let via switch box.
3
405
1217.46
... More
code18 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.1.3, PN-5, VOL-6, Long point above 6m upto 10m from tapping point to out let via switch box
1
587
587.1
... More
code19 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.3.2, PN-5, 1.5 mm2
20
26
535.6
... More
code20 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.3.3, PN-5, VOL-6, 2.5 mm2
15
43
648.9
... More
code21 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-2.3.4, PN-5, VOL-6, 4 mm2
10
64
648.9
... More
code22 - Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654,CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.1.2, PN-8, VOL-6, 6A 3/5 Way
1
151
151.41
... More
code23 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.6.9, PN-9, VOL-6, 32A DP Switch
1
335
335.78
... More
code24 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.4.2, PN-8, VOL-6, 1-3 Way.
1
127
127.72
... More
code25 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.4.6, PN-8, VOL-6, 10-12 Way.
1
268
268.83
... More
code26 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.5.2, PN-8, VOL-6, 3 Module
1
165
165.83
... More
code27 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.5.6, PN-8, VOL-6, 10-12 Module
1
354
354.32
... More
code28 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greaterthan 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greaterthan IK08. Power Factor Greaterthan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED fficiencyGreaterthan1301m/w, nominal CRI Greaterthan 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.Note : 3) LED street lights that is procured, shall comply to the specification as per DMA Order(No. 25775DMA 69 DEVT 2018-19 Dated : 03-01-2019 ).(PWD Electrical CSR 2021-2022, IN-3.5.6, PN-5(Part-1)), LED Streetlight 25 W
1
2497
2497.75
... More
code29 - Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 24, IN-13.2.1, PN-56, VOL-6, Using 25mm dia G.I.Pipe
1
1239
1239.09
... More
code30 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-13.5, PN-56, VOL-6.
1
166
166.86
... More
code31 - Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI reaterthan 80. Power Input: 220-240V@ 50/60Hz & Power factor greaterthan 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-11.3.2, PN-43, VOL-6, LED light fighting LED light fitting 1 x 4 - 20/22 W
1
710
710.7
... More
code32 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greaterthan 70%. efficacy greaterthan 80 lumen per W, life greaterthan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greaterthan 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.,CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-11.11.4, PN-47, VOL-6, 9W, 6500K
1
158
158.62
... More
code33 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-13.7.1, PN-56, VOL-6.
2
125
251.32
... More
code34 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-3.14.6, PN-10, VOL-6, 6A Lamp Holder
2
73
146.26
... More
code35 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-6.1, PN-30, VOL-6.
3
1536
4610.28
... More
code36 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-13.13, PN- 57, VOL-6
3
728
2184.63
... More
code37 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.18.4, PN-17, VOL-6, 6-32 A DP
1
761
761.17
... More
code38 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.42.1, PN-20, VOL-6, 14SWG.
1000
-
510
... More
code39 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.40.1, PN-20, VOL-6, 100 A 4 x 30 x 6 mm Aluminium Strips
1
2538
2538.95
... More
code40 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-5.30, PN-19, VOL-6
1
1421
1421.4
... More
code41 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-12.56, PN-54, VOL-6.
1
3615
3615.3
... More
code42 - Guy Wire & GI Wire as per IS-2141, GI Wire 8 SWG, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-8.02, PN-55, VOL-6
0.025
77291
1932.28
... More
code43 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m, PWD CSR 2023-2024, IN 1.6.1, PN-6, VOL-1
9
498
4486.68
... More
code44 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 24, IN-32.05, PN-13, VOL-6, 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)
0.06
146097
8765.8356
... More
code45 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm, CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-21.05, PN-52, VOL-6.
0.06
21512
1290.7548
... More
code46 - Aluminium End Terminal (Lug), CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024, IN-60.02, PN-27, VOL-6. 16Sqmm
2
3
6.18
... More
code47 - Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. CSR for Water Supply & Sewerage Works 2023 - 24, IN-11.2.5, PN-127, VOL-5, .Medium Duty GI pipe of 40mm dia
2
502
1005.28
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements