Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction
Solid Waste Management
Opening Date4 Dec 2024
Closing Date21 Dec 2024
Tender Amount₹ 8,54,99,999.99 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vol-1 2.1.3 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ( CM SR 2023-24 P.No.15/Vol-1/2.1.3 )

133.69

6288

840702.8805

... More
Vol-2 5.4 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (CM SR 2023-24/P.No.9/Vol-2/5.4)

303.74

6708

2037624.603

... More
Vol-1 21.6 - Ruled/ Flush pointing on White sand stone masonry surface with lime, surkhi and marble dust mortar in the ratio of 1:1.5:1/2 One lime : 1.5 surkhi (15 dark red and 85 light yellow surkhi) : 1/2 marble dust. (The rate is inclusive of all materials labours involved except scaffolding). ( CM SR 2023-24 P.No.218/Vol-1/21.6)

4.05

258

1046.115

... More
Vol-2 6.4 - Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour,scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.( CM SR 2023-24 P.No.13/Vol-2/6.4 )

12.45

9094

113220.9225

... More
Vol-1 Sl.No7 - Providing and laying 40mm size graded coarse aggregates /pebble stones for side as per drawing, specifications with all leads and lifts complete etc.,as directed by the Engineer.The rate includes cost of material, transportion, laying and compacting with all labour etc., (For drainage layers) :( CM SR 2023-24 P.NO.A-38/Vol-1/Sl.No7)

4.31

1190

5128.9

... More
Vol-1 Sl.No9 - Providing and laying 100mm size graded coarse aggregates /pebble stones (For filter bed)as per drawing, specifications with all leads and lifts complete etc.,as directed by the Engineer.The rate includes cost of material, transportion, laying and compacting with all labour etc., (For drainage layers) :( CM SR 2023-24 P.NO.A-38/Vol-1/Sl.No9)

5.22

1143

5966.46

... More
Vol-1 1.11 - Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete. (CM SR 2021-22/P.No.7/Vol-1/1.11) Filling.

2.78

2177

6052.06

... More
Vol-1 Sl.No5 - Providing and laying 25mm size graded coarse aggregates /pebble stones (For filter bed)as per drawing, specifications with all leads and lifts complete etc.,as directed by the Engineer.The rate includes cost of material, transportion, laying and compacting with all labour etc., (For drainage layers) :( CM SR 2023-24 P.NO.A-38/Vol-1/Sl.No5)

2.16

1333

2879.28

... More
Vol-1 2.2.5 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(CM SR 2023-24/P.No.15/Vol-1/2.2.5) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For footing

505.62

7369

3726353.6694

... More
Vol-1 2.3.3 - Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (CM SR 2023-24/P.No.16/Vol-1/2.3.3) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for plinth beam

98.08

10402

1020314.4704

... More
Vol-1 2.4.2 - Providing and laying in cement concrete for all Substructures of building irrigation works, Sub structures bridges return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (CM SR 2023-24/P.No.16/Vol-1/2.4.2) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for plinth beam

4.54

7303

33155.9378

... More
Vol-1 2.4.2 - Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CM SR 2023-24/P.No.16/Vol-1/2.4.2) For septic tank top slab 14.2

0.83

9958

8265.7459

... More
Vol-1 1.11 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CM SR 2023-24/P.No.7/Vol-1/1.11) Filling.

2757.48

454

1253688.282

... More
Vol-2 6.32 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( CM SR 2023-24/ P.No.17/Vol-2/6.32)

1680.3

1375

2311252.65

... More
Vol-2 6.33 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( CM SR 2023-24/ P.No.17/Vol-2/6.33)

189.08

1159

219181.536

... More
V3 1 2.1.5 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates(CM SR 2023-24/P.No.15/Vol-/2.1.5)

6.42

6463

41497.596

... More
V-3 Clause 401 - Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (i) For Grading -I Material

992.38

2611

2591451.513

... More
V-1 2.4.2 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol I I.No. 2.4.2 P.No. 16)SR 2023-24

56.7

8962

508193.595

... More
Vol-1 2.4.2 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol I I.No. 2.4.2 P.No. 16)SR 2023-24

37.8

6971

263507.958

... More
Vol-3 Item No 16.28 - Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (CM SR 2023-24/P.No.149/Vol-3/16.28)

995.59

7091

7060425.603

... More
Vol-3 4.17 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (CM SR 2023-24/P.No.26/Vol-3/4.17)

992.38

2686

2666475.441

... More
ele01 - Line Supports Pole -RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section Dwg No. BESCOM/GM/QSS/51 Dtd 24.11.2018 as per IS-785 Sl.No. 1, I.No. 1.02 , P.No. 3of 81, Vol-6, ESCOM's SR 2023-24

6

8731

52390.8

... More
ele02 - Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. Labour Charges in Common SR 2023-24 11 kV System Sl.No. 1, I.No. 1.1.1 , P.No. 43 , Vol-6, ESCOM's SR 2023-24

6

660

3962.7

... More
ele03 - Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth Labour Charges in Common SR 2023-24 11 kV System Sl.No. 1, I.No. 2.02 , P.No. 44 , Vol-6, ESCOM's SR 2023-24

6

1168

7011.9

... More
ele04 - Cross Arms MS GI as per IS-1977- 11 2.01 11 kV, Horizontal Cross Arm - Mild Steel MS Dwg No.BESCOM/GM/QSS/04 Dtd 24.11.2018

4

390

1562.4

... More
ele05 - H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - For DP structure for providing New GOS for sectionalisation - MS Sl.No2, I.No. 2.01 , P.No. 3of 81, Vol-6, ESCOM's SR 2023-24

2

4548

9097.2

... More
ele06 - DISC Insulator 45 kN Porcelain Sl.No55, I.No.6.09 , P.No. 5of 81, Vol-6, ESCOM's SR 2023-24

12

535

6426

... More
ele07 - Spiral Earth Electrode Sl.No.26, I.No. 2.16 , P.No. 4of 81, Vol-6, ESCOM's SR 2023-24

6

250

1505.7

... More
ele08 - Providing Spiral Earth Electrode type earthing without Labour Charges in Common SR 2023-24 11 kV System Sl.No. 36, I.No.2.08 , P.No. 44 , Vol-6, ESCOM's SR 2023-24 charcoal, salt etc.,

6

97

585.9

... More
ele09 - Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing Labour Charges in Common SR 2023-24 11 kV System Sl.No. 51, I.No.5.03 , P.No. 45 , Vol-6, ESCOM's SR 2023-24

6

269

1619.1

... More
ele10 - ACSR Conductor as per IS-398 Part - 2/1996 -Rabbit ACSR Sl.No59, I.No. 7.02 , P.No. 3of 81, Vol-6, ESCOM's SR 2023-24 6/3.35 mm Al + 1/3.35 mm St, Std Wt 214 Kg/KM

0.2

48545

9709.14

... More
ele11 - Stringing of conductor Rabbit ACSR, binding of conductor on each insulator and dead ending on strain or disc/strain insulator bymeans of clamps Labour Charges in Common SR 2023-24 11 kV System Sl.No. 64, I.No.6.02 , P.No. 46 , Vol-6, ESCOM's SR 2023-24

0.2

4579

915.81

... More
ele12 - 11 kV, 200 Amps Single Break GOS, Vertically Operated Sl.No168, I.No. 24.03 , P.No.11, Vol-6, ESCOM's SR 2023-24

2

14413

28826.7

... More
ele13 - Fixing of GOS including wiring 11 kV Single Break 200 Amps Labour Charges in Common SR 2023-24 11 kV System Sl.No. 97, I.No.13.02 , P.No.48 , Vol-6, ESCOM's SR 2023-24

2

1159

2318.4

... More
ele14 - 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR Dwg No. BESCOM/GM/QSS/26 Dtd 24.10.2007 Sl.No137, I.No. 19.01 , P.No.9, Vol-6, ESCOM's SR 2023-24

3

966

2898

... More
ele15 - Fixing of 3 Nos Lightning Arrestor including wiring Labour Charges in Common SR 2023-24 11 kV System Sl.No.101, I.No.13.06 , P.No.48 , Vol-6, ESCOM's SR 2023-24

1

124

124.95

... More
ele16 - 11 kV, HG Fuse Unit with Solid Core Insulator Dwg No. BESCOM/GM/QSS/21 Dtd 24.11.2018 3 nos Sl.No139, I.No. 20.01 , P.No.9, Vol-6, ESCOM's SR 2023-24

3

1122

3367.35

... More
ele17 - Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring Labour Charges in Common SR 2023-24 11 kV System Sl.No.96, I.No.13.01 , P.No.48 , Vol-6, ESCOM's SR 2023-24

1

248

248.85

... More
ele18 - Conventional RMU VCB Type with Copper Busbar, 350 MVA, 630 Amps as per IEC 62271/IS-3427,One Breaker VL Panel with Copper Busbar As per ESCOM SR 2023-24 page no 16 of 81, SL NO -38 item no 38.05

1

489260

489260.1

... More
ele19 - Fixing foundation frame of channels and angle iron welding fixing in concrete aligning the RMU on foundation bed, assembly of units, connecting Bus Bars from panel to panel initial filling of oil etc.,complete. 1 panel

1

5084

5084.1

... More
ele20 - Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., Labour Charges in Common SR 2023-24 11 kV SystemSl.No.201,I.No.23.07 , P.No.53 , Vol-6, ESCOM's SR 2023-24

1

1009

1009.05

... More
ele21 - Distribution Transformer - 3Distribution Transformer - 3 Phase,11kV/433V - Stacked CRGO Core with Oil as per IS-1180 Part-1 2014.250 kVA, 250 kVA, Aluminium Wdg, Star 2 5 Star B CABLE ENTRY TYPE As per ESCOM SR 2023-24 page no 7 of 81, SL NO 102item no 12.18

1

569830

569830.8

... More
ele22 - 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated as per revised Specification Dwg No. BESCOM/GM/QSS/-- Dtd 24.11.2018 As per ESCOM SR 2023-24 SL NO - 455 Item No - 58.01 - Page No - 26

1

255645

255645.6

... More
ele23 - 11kV HT XLPE U/G CABLE 11 kV, 3 Core,3c x 240 sqmm. Al conductor XLPE 11KV grade XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 Part-2 Armouring wires dia and Resistivity as per IS-3975 P.No.258, I.No.36.05- I Vol-6 of KPWD S.R 2023-243c x 240 sqmm. Al conductor XLPE 11KV grade

0.16

1738850

278216.064

... More
ele24 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools other appurtenaces required to complete the work. Sl.No.1.4, I.No.1.4.1 , P.No. 5 , Vol-1, PWD SR 2023-24

180

254

45738

... More
ele25 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff Labour Charges in Common SR 2023-24 11 kV System Sl.No. 170, I.No.21.02 , P.No. 52 , Vol-6, ESCOM's SR 2023-24

0.2

67360

13472.13

... More
ele26 - Supply and making 11KV E Extruted X Linked for tubing moulded and cross linked componets using heat shrinked stress control tube having high permittivity XLPE terminations INDOOR OUTDOOR JOINTING KIT confirming to the GTP Page 183 Item No 22.05 Of Ele SR - 2023-2024Out door type 3x185 to 3x240 Sqmm

24

2790

66981.6

... More
ele27 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. SM Enclosure Sheet Metal Execution Page 15 of 105 Item No 5,12.6. Vol-6 of Ele SR - 2023-24 400 Amps

1

34589

34589.1

... More
ele28 - Supplying and fixing hylum plastic sheet 3 mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws P. No. 9, Sl. No. 3.9, Vol-6, Part-III of PWD Ele SR 2023-24

13000

-

4810

... More
ele29 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100 lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open.Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. a FOUR Pole - 400 A 36 kA PWDElectrical SR 2023-24 - Page no - 16 of 105, Item no - 5.15.16

1

29626

29626.8

... More
ele30 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole - 250 A 25 kA PWDElectrical SR 2023-24 - Page no - 16 of 105, Item no - 5.15.13

2

22460

44921.1

... More
ele31 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.125Amps 4Pole 25kA Page 17 Item No 5.15.10 Vol-6 of SR - 2023-24

2

10858

21716.1

... More
ele32 - Supplying fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. PWDElectrical SR 2023-24 - Page no - 17of 105, Item no - 5.18.8 40 A TPN

4

3196

12784.8

... More
ele33 - Supplying 400 A 4 x 50 x 10 mm A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete a 400 A 4 x 50 x 10 mm Aluminium Strips PWDElectrical SR 2023-24 - Page no - 20of 105, Item no - 5.40.3

8

4667

37338

... More
ele34 - Supplying 400 A 4 x 50 x 10 mm A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips PWDElectrical SR 2023-24 - Page no - 20of 105, Item no - 5.40.2

4

3606

14427

... More
ele35 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. PWDElectrical SR 2023-24 - Page no - 18 of 105, Item no - 5.21

1

9717

9717.75

... More
ele36 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. PWDElectrical SR 2023-24 - Page no - 19 of 105, Item no - 5.38

3

540

1622.25

... More
ele37 - Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter PWDElectrical SR 2023-24 - Page no - 19 of 105, Item no - 5.29

2

1496

2992.5

... More
ele38 - Supply and fixing of 75 x 75 x 6 mm angle iron frame work fabricated out of ms angle iron,.. With bolts , washer, etc, and painted with 2 coat of red oxide and then two coats of approved paint. P. No. 20, Sl. No. 5.41.3, Vol-6, Part-III of PWD Ele SR 2023-24

12

582

6993

... More
ele39 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Page 19 Item No 5.33 Vol-6 of SR - 2023-24

1

9780

9780.75

... More
ele40 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. Page 19 Item No 5.34 Vol-6 of Ele SR - 2023-24

3

590

1770.3

... More
ele41 - Supplying and fixing 50-63Amps TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. Page 18 Item No 5.18.9 Vol-6 of SR - 2023-24

4

3242

12969.6

... More
ele42 - Supplying ,fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor.. Cost per KVAR. Page 19 Item No 5.37 Vol-6 of SR - 2023-24

20

504

10080

... More
ele43 - Supplying of -1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a 3.5core x 240 sqmm Page 13 of 81 Item No 32.18Vol-6 Of Ele Escom SR - 2023-24

0.35

905799

317029.755

... More
ele44 - Supplying of -1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-39753.5core x 25 sqmm Page 13 Item No 32.07 Vol-6 Of SR - 2023-24

0.2

146526

29305.29

... More
ele45 - Supplying of -1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4core x 16 sqmmPage 13 Item No 32.05 Vol-6 Of SR - 2023-24

0.3

148934

44680.23

... More
ele46 - Labour Charges for laying of 1.1Kv class UG cable when supplied departmentally/agency in existing trench GI pipe/stoneware pipe/on wall /on pole as required In existing trench/duct a 120 to 240 Sqmm sl no 176 item no21.07 of VOL 6 2023-24 CSR

0.35

33891

11862.165

... More
ele47 - Labour Charges for laying of 1.1Kv class UG cable when supplied departmentally/agency in existing trench GI pipe/stoneware pipe/on wall /on pole as required In existing trench/duct 2.5 to 25 Sqmm Sl no 174 item no 21.05 of VOL 6 2023-24 CSR

0.5

21930

10965.15

... More
ele48 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes Heavy Duty Copper Terminal Long Barrel a 240 Sqmm Copper Terminal, Apprx Wt 218 Gm Sl.No. 462, item no 59.10, P.No. 26,Vol -6 Escom SR 2023-24

24

372

8946

... More
ele49 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes Heavy Duty Copper Terminal Long Barrel Brass Cable Gland for 10 to 16 mm cable -25 SqmmP. No. 28 of 81 Escom SR, Sl. No.507, I. No. 63.01, Vol-6, Part-III of ESCOM's SR 2023-24

10

82

829.5

... More
ele50 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer in-charge. Made of G.I. wire of dia 4 mm Transformer yard 6m x 4 m = 24sqm Vol-02 Item No.11.58 PG NO-95

48

843

40471.2

... More
ele51 - Jelly Spreading 20-25 mm Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedPage 158 item no 01 of KPWD SR - 2023-2024 vol -6

4.8

1861

8935.92

... More
ele52 - Supplying and fixing regular MCB distribution boards on wall/woodboard/flush mounting using required clamps ,bolts,nuts,etc with provision for fixing suitable type capacity MCB's single phase/3phase /double door with powder coated painting. Made out of 14 SWG MS Enclousure. 8 way SP N Page 18 Item No 5.19.8 Vol-6 Of Ele SR - 2023-24

4

1946

7786.8

... More
ele53 - Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a 6 to 32Amps DP Page 17 Item No 5.18.4 Vol-6 Of SR - 2023-24

9

775

6983.55

... More
ele54 - Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps TPN Page 17 Item No 5.18.7 Vol-6 Of Ele SR - 2023-24

3

1802

5408.55

... More
ele55 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS6942010 a1.5sqmm Page 5 Item No 2.3.2 Vol-6 Of SR - 2023-24

2000

27

54600

... More
ele56 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 sqmm Page 5 Item No 2.3.3 Vol-6 Of SR 2023-24

1500

44

66150

... More
ele57 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4.0sqmm Page 5 Item No 2.3.4 Vol-6 Of SR - 2023-24

800

66

52920

... More
ele58 - Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws a 19/20mm dia,2mm thick Page 2 Item No 1.2.1 Vol-6 Of SR - 2023-24

1000

69

69300

... More
ele59 - Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws25mm dia,2mm thick Page 2 Item No 1.2.2 Vol-6 Of SR - 2023-24

300

81

24570

... More
ele60 - Supplying heavy gauge PVC conduit pipe…. Dia 2mm, 2.5mm thick with suitable size bends, metal junction boxes, adhesive paste etc., by groove cutting in the wall fixing by bracing "U" or "J" hooks cement plastering up to the wall surface and run with 18SWG GI fish wire run throut the conduit wherever necessary. a 19/20mm dia,2mm thick Page 2 Item No 1.3.1 Vol-6 Of SR - 2023-24

100

71

7140

... More
ele61 - Supplying heavy gauge PVC conduit pipe…. Dia 2mm, 2.5mm thick with suitable size bends, metal junction boxes, adhesive paste etc., by groove cutting in the wall & fixing by bracing "U" or "J" hooks & cement plastering up to the wall surface and run with 18SWG GI fish wire run throut the conduit wherever necessary. 25mm dia,2mm thick Page 2 Item No 1.3.2 Vol-6 Of SR - 2023-24

50

82

4147.5

... More
ele62 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm Phase Neutral 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694 and latest amendments with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. aShort point upto 3Mts from tapping pt to out let via Switch boxPage 5 Item No 2.1.1 Vol-6 Of SR - 2023-24

40

299

11970

... More
ele63 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3M upto 6M from tapping pt to out let via Switch boxPage 5 Item No 2.1.2 Vol-6 Of SR - 2023-24

35

413

14479.5

... More
ele64 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6M upto 10M from tapping pt to out let via Switch box Page 5 Item No 2.1.3 Vol-6 Of SR - 2023-24

20

598

11970

... More
ele65 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlets in a row above 3M upto 6M from tapping pt to out let via Switch box Page 5 Item No 2.1.4 Vol-6 Of SR - 2023-24

4

743

2973.6

... More
ele66 - LT Feeder Piller Box MS Thermoset Plastic 8 Way with Poreclain Rewireable Cutout and 1 No of 630 Amps Load Break Switch with Copper Busbar as per IS-13947 Part-12 Refer Dwg No. BESCOM/GM/QSS/41 Dtd 24.11.2018 Page 190 Item No 30.01 Vol-6 Of SR - 2023-24

3

54724

164174.85

... More
ele67 - Errection of LT Feeder piller box MS Thermoset Plastic Enclosure including necessary civil works like soil excavation concreting etc. complete Labour Charges in Common SR 2023-24 11 kV System Sl.No. 80, I.No.9.03 , P.No.47 , Vol-6, ESCOM's SR 2023-24

3

1756

5269.95

... More
ele68 - Supplying flush mounting powder coated / Galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/C.C wall a6 way Page 8 Item No 3.4.4 Vol-6 Of SR - 2023-24

3

231

693

... More
ele69 - Supplying & flush mounting powder coated / Galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/C.C wall10-12 way Page 8 Item No 3.4.6 Vol-6 Of SR - 2023-24

3

334

1004.85

... More
ele70 - Supplying and fixing Metal fan box with round hook Page 4 Item No 1.13 Vol-6 Of SR - 2023-24

16

122

1965.6

... More
ele71 - Supplying and fixing of modular switch connected accessories on existing modular switch plate as per IS 3854 and IS 1293. a6Amps one way Switch Page 9 Item No 3.6.1 Vol-6 Of SR - 2023-24

70

107

7497

... More
ele72 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch Page 9 Item No 3.6.2 Vol-6 Of SR - 2023-24

8

174

1394.4

... More
ele73 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket Page 9 Item No 3.6.3 Vol-6 Of SR - 2023-24

46

179

8259.3

... More
ele74 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A universal socket Page 9 Item No 3.6.10 Vol-6 Of SR - 2023-24

12

247

2973.6

... More
ele75 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch Page 9 Item No 3.6.7 Vol-6 Of SR - 2023-24

3

189

567

... More
ele76 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped fan regulator Page 9 Item No 3.6.4 Vol-6 Of SR - 2023-24

16

374

5997.6

... More
ele77 - Supplying fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. a8 Module Page 8 Item No 3.5.5 Vol-6 SR - 2023-24

3

298

894.6

... More
ele78 - Supplying & fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. 10 -12 Module Page 8 Item No 3.5.6 Vol-6 SR - 2023-24

3

361

1083.6

... More
ele79 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input 220-240V 50/60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 4' - 28 watts Page No.43 Sl No.11.3.2 Vol-6 SR 2023-24

40

724

28980

... More
ele80 - Supply of LED Streetlight with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation. Diffuser with injection moulded is made of polycarbonate material with high transmission index, delivering superior light output. Rated life Burning Hrs 50000hr Lumen Maintenance of 70. CCT 5500K, IP 66 optical and electrical compartment impact resistance of complete luminare 1K08. Power Factor 0.9 with mains Current should not be greater than 0.1A to 0.7A Surge Protection- Min 4KV alongwith Over voltage/Overload, short circuit/ miss-wiring protection. Compatable for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operates wide voltage range from 100V to 270V 50/60Hz application. Over load Short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access streetlight with single screw to encure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .......W System Power consumption. LED Efficiency130/w at Fixture Efficiency 80lm/w with nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI any Government certified agency Design Development facility certified by ISO 90012008. Housing with supplier word make/name shall be Engraved / Embossing on the die cast housing/Body part. Warranty of 5 years against any manufacturing defect working under standard electrical conditions Suitable for B1/B2 Roads as per IS 1944 Part Port II. LED Streetlight 200 wattsPage 46 Item No 11.8.8 Vol-6 SR - 2023-24

27

20048

541314.9

... More
ele81 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI any Government certified agency Design Development facility certified by ISO 90012008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 200 wattsPage 46 Item No 11.9.2 Vol-6 SR - 2023-24

25

9960

249007.5

... More
ele82 - Supplying fixingof Hot dip galvanized MS bracket suitable for out door Luminaries and mounted on Octoganal pole using necessary bolts, nuts etc., Complete.fixing to wall of the building Single arm Bracket with 1500 mm standard 40/50 mm dia Page 13 Item No 4.6.2 Vol-6 Of SR - 2023-24

27

2205

59535

... More
ele83 - Supplying capacitor type 48" sweep ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. single phase AC supply confirminf to ISS-374-1979 and with double ball bearing system. 48" Sweep 1200mm Regular model Page 30 Item No 6.3.1 Vol-6 Of SR - 2023-24

16

3133

50131.2

... More
ele84 - Supplying exhaust fan of 1440 RPM of 300mm 12" size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC supply, Page 30 Item No 6.1 Vol-6 Of SR - 2023-24

8

1566

12532.8

... More
ele85 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep450 mm Page 30 Item No 6.2.2 Vol-6 SR - 2023-24

2

4668

9336.6

... More
ele86 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires Page 56 , Item No 13.05 Vol-6 SR - 2023-24

45

170

7654.5

... More
ele87 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. Page 56 Item No 13.7.1 Vol-6 SR - 2023-24

60

128

7686

... More
ele88 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Page 57 Item No 13.10 Vol-6 SR - 2023-24

46

179

8259.3

... More
ele89 - Supplying fixing and wiring earth electrode for grounding of lift, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all around with alternate layers of salt and charcoal form the bottom of the pipe to the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts. Page 54 Item No12.57 Vol-6 Of SR - 2023-24

14

4468

62563.2

... More
ele90 - Supplying Fixing Chemical earthling for grounding. Conduits, IC cutouts other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance capable of achieving ohmic value less than one ohm Using 10ft. Copper bonded rod with backfill compound Using 10ft. Copper bonded rod with backfill compound Page 55 Item No 12.60.3 Vol-6 Of SR - 2023-24

4

8918

35674.8

... More
ele91 - Supplying and running of GI / Copper strips for grounding connections using necessary fixing materials as required a 25x6mm GI strip Page 54 Item No 12.58.7 Vol-6 Of SR - 2023-24

50

134

6720

... More
ele92 - Supplying and running of GI / Copper strips for grounding connections using necessary fixing materials as required 600X600X3mm Copper Plate Page 55 Item No 12.58.11 Vol-6 SR - 2023-24

2

7792

15584.1

... More
ele93 - Supplying and running of GI / Copper strips for grounding connections using necessary fixing materials as required25X3mm GI strip Page 54 Item No 12.58.2 Vol-6 SR - 2023-24

50

86

4305

... More
ele94 - Geophysical investigation of site for sinking bore well for supplying drinking water to the habitation either through the hand pump, MWSS or PWSS by verticle electrical sounding by adopting venner or schluber's method ,including reconnaissa nce survey of geological formation, geophy sical investigation of existing ground water in the vicinity, its quality, quantity acceotability of the users indicating the location of site, recommended depth of casing pipe required to seal the top uncon solidated formation for proper seating of casing pipe, depth of 1.0 meter in consoildated formation for proper seating of casing pipe ,depth of drilling required to coverfull depth of aquifer proposed to be tapped probable yield and other information of instrument and accessories to work site, engaging technical personal and labour required etc.common SR 2023-24 vol-5,IN12.4PN-140

1

5552

5552.4

... More
ele95 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG above 1100 CMF above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour Excluding cost of casing pipes,collars, cap etc., complete common SR 2024-23 vol-5,IN12.1.1,2,3.1.PN-139.Borewell depth of 0 to 50 m,

50

388

19425

... More
ele96 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG above 1100 CMF above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour Excluding cost of casing pipes,collars, cap etc., complete common SR 2024-23 vol-5,IN12.1.1,2,3.1.PN-139.above 50 m upto 100m,2nd correngendum w.e.f.7/6/2022

50

487

24360

... More
ele97 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG above 1100 CMF above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour Excluding cost of casing pipes,collars, cap etc., complete common SR 2024-23 vol-5,IN12.1.1,2,3.1.PN-139.above 100 m upto 150m,2nd correngendum w.e.f.7/6/2022

50

517

25882.5

... More
ele98 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipegrade of steel Fe 410 of wall thickness conforming to IS 4270-2001 andlatest ammendments, electrical resistance welded steel tubes, materialand conforming to IS 1387-1993 and manufactured by basic openhearth electric or basic oxygen process in random length of 5-7m bothends.threaded conforming to IS 554-1985 one end fixed with socketconforming to IS 4270-2001 and the other end with screwed pipes allshall be responsibaly free from defects. The tubes shall be responsiblestraight end should be with ISI marking weighing 25.10kg/m.pricesinclude Collar-Medium duty.common SR 2023-24 vol-5,I.no12.32.PN-143

36

2029

73067.4

... More
ele99 - Providing and fixing MS casing collars as per IS 1239 part-II 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm minimum. The dimensions of caps and colars shall be strictly as per IS 1239 Part-II 1982 with all amendments common SR 2023-24 vol-5,IN 12.33,PN-143

6

157

945

... More
ele100 - Providing and laying at site of work MS casing caps as per IS 1239 part-II 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm minimum. The dimensions of caps and colars shall be strictly as per IS 1239 Part-II 1982 with all am en d m en ts in clu d in g cost of m aterial an d lab ou r charg es for fixing, if any etc. complete with all lead and lifts and as d irected b y the En g in eer in charg ecommon SR 2023-24 vol-5,IN12.34.PN-143

1

172

172.2

... More
ele101 - Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work common SR 2023-24 vol-5,.PN-156, I.no.13.32

1

6825

6825

... More
ele102 - Providing,supplying to work site, Submersible Pump Set of 150mm diasuitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl Impeller with Low volt Motor as per specifications,as per necessaryammendments and instructions of engineer incharge of work.5.00 HP - 90 LPM 110 m = 10 STG Outlet Dia - 2.00”.common SR 2023-24 vol-5,IN13.13.3PN-151

1

28980

28980

... More
ele103 - Supplying,laying,jointing ,testing and commissioning of G.I. Pipes conforming to IS 12391990 with latest amendments, including fixing Collars, Elbows, Tees, b en d s, Glad Cocks an d other Fittin g s Excl u d in g Cost of Specials with Cuts and Threads wherever n ecessary in clu d in g conve yi n g the m aterials to w orksp ot, in clu d in g testin g f or w ater tig htn ess w ith all lead an d lif ts etc com plete Con tractor shall m ake his ow n arran g em en ts for procu rin g w ater for testin g Class-B Medium 50mm dia common SR 2023-24 vol-5,IN11.2.6.PN-127,N010F,

120

613

73584

... More
ele104 - Supplyinganddrawing3coreflatPVCsheathedsubmersiblepumpcablemanufacturedwithelectrolyticgradecopperwithflexiblecopperwithlowresistanceconductorconfirmingto1381301984andvirgingradePVCinsulationandpowdercoatingextrudedPVCsheathedsuitable for working voltage upto 1100 Volts as per IS6941990.P.no.7,I.no.2.6.2

250

176

44100

... More
ele105 - Providing wrought mild steel galvanized 50 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. 50mm dia common SR 2023-24 vol-5,IN 11.6.6.4.PN-129,

20

280

5607

... More
ele106 - Supply and delivery at site wrought middle steel galvanized 50 mm dia GI union confirming to IS 1239- II, 1991 with latest amendments if any. 50mm dia common SR 2023-24 vol-5,PN-131, I.no.11.12.6

2

280

560.7

... More
ele107 - Supply and delivery at site wrought middle steel galvanized 15 mm dia GI bend confirming to IS 1239- II, 1991 with latest amendments if any. 50mm dia common SR 2023-24 vol-5,N 11.8.6.PN-130

1

375

375.9

... More
ele108 - Supply and delivery at site of brand new best make non-return valve asper IS 778/1984 with ISI Mark and as per its latest amendments.common SR 2023-24 vol-5,.PN-154.I.no. 13.25.1Size 50 mm

1

1312

1312.5

... More
ele109 - Cutting Asphalt /Concrete road surface using machine cutter for leakagepit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor,Jeep with all kinds of Labour in a Complete manner. V-5 3.3 SR23-24 pg no 48

3.6

1214

4373.46

... More
ele110 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOINGfor Main Electrical Pump 1 No. MCB 1 No. DOL of S/D Startersuitable for respective HP 1 No. Electrcal Protection Like single Phasepreventor, under voltage over Volage, under current over current dryrun protection suitable for the pump described above 1 no Indoor type NOTE 1 DOLDirect Online Starter 2S-D- Star Delta StarterUpto 6 HP pumps.common SR 2021-22 vol-5,I.no.13.23.2.1,PN-155.

1

10027

10027.5

... More
ele111 - Providing main connection from pole PVC insulated sheathed steel wirecable in new trench as per IS 1554/ 1988 with latest amendments with ISImark from KPTCL pole to meter board unit..common SR 2021-22 vol-5,.PN-156. I.no.13.36

25

141

3543.75

... More
ele112 - Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesP.no15, I.no2.2.1,2023-24SR

0.53

6601

3498.7155

... More
ele113 - Supplying, fixing and wiring Electronic Trivector Meter ETV 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. Common SR 2023-24 Item No 5.35 Pg No 18

1

5990

5990.25

... More
ele22 - Construction of platform with size stone, cement concret for erectionof 250 KVA Transformers/ Heavy Equipment. Construction of platform (1.5X 1.5 X1.52 ) mtr in size stone, for erection of Transformers/Heavy equipment including all materials, labour. Excavation of (1.5 X 1.5 x1.5)mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement mortor 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., platering the concrete surfaces in cement mortor 1:4 including smooth rendering curing etc., curing at every stages completely. BESCOM SR 2022-23 PAGE NO 2 - Item No 4.06

3

31879

95637.15

... More
ele28 - LT PANEL - 1 Nos. 250kva Transformer- Supply, Installation, Testing and Commissioning of METER PANEL . 16 GAUGE CRCA SHEET panels including the cost of pedestals required to fix the panels shall be generally as per the SLD and specification). : Fabrication suppling and mountuing MS box, made out 14 SWG suitable floor / wall mounting , fully weather proof with privision for better heat disspation , provided with hinged front cover, equipped with temper proof locking arrangements , with suitable size clamps with necessary cable entey pipe with gland and box should be finsihed with 7 tanks treatment with powder coated paint and finllay finished with approved colour etc,. complete. 14 SWG(P. No. 20, Sl. No. 5.42.1, Vol-6, Part-III of PWD Ele SR 2023-24)

250000

-

132500

... More
Non SR Item - Providing and fixing of self supported mechanically seamed roofing system such as proflex, green curve, Kialash roofing or equivalent made of high strength quality steel, having 340 MPA yield strength, pre coated galvalume sheet as per ASTM A792 M of base metal thickness 1.4 mm (Tolerance (+/- 0.02 mm). high grade steel sheet should have 55% aluminium and 45% Zinc coating by hot dip process of minimum 25 micron on top side and 12 micron on back side with epoxy primer and polyester wash -coat as per AZM 150. Roofing should be designed as per ASCE 7-20 international building code 2002. The analysis should carried out for span and centre arch -rise considering the required live load, wind load, dead load and seismic factor. The analysis should also determine the thickness of steel and the end reaction at the beam level. Shop drawing of roofing system shall be submitted by contractor through consultant and same shall be checked and approved by the department. The roof panel formation shall be done as per the required length and curvature using hydraulic profile machine to give it the trapezoidal shape in required curvature. In this process the width of sheet the width of sheet reduces from 0.914 meter to 0.61 meter (tolerance +/- 0.02 mm). The roof panel shall be lifted using a suitable crane and using a spreader bar and a sling evenly placed to ensure no distortion of panel till the alignment is done and completed using plumb and a water tube and bolted into beam. These curved panels have interlocking formation and are crimped together using mechanical seaming machine which imposed a load of approximately five tonnes to ensure the seaming of required rigidity. After seaming a clear epoxy lacquer is applied on the inner side of panel and concrete beam. Theses panel are installed over water proof concrete gutter - beams having bevelled edge to receive (support) curved panels. Beam shall designed for arch reaction and vertical loads. Plaster shall not be applied on the beam. Schmitt hammer test of concrete should be carried before erection to ensure that the anchor bolt can be securely fixed on the support. In case of steel structure a steel runner plate of 6 mm thickness and GI sheet gutter of suitable size shall be provided for installation of panels, G.I. anchor bolt of required sizes and type with G.I. washer and neoprene asher shall be as design. After installation of panels, rapezoidal voids are created between gutter-beam and panels which should be covered by a flashing fabricated or brick masonry which is to be paid separately. Area of this roof shall be measured along the periphery on hem-top between end to end panels. Ridge and valley shall not taken in to consideration for measuring length transverse to periphery. The rate includes supplying, fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolt, epoxy, paint and all wastage etc. complete. Accessories and fixtures like hangers /clamp for installation of lighting/ fixtures /utility/duct as per requirement and ventilators, skylight can also be provided at crown/ridge by making cuts into the panels which is to be paid separately. This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise.

5500

2300

12650000

... More
Non SR Item - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

965

596

575526

... More
Vol-2 7.69.3 - Providing and fixing Aluminium Turbo ventilator complete as per technical specifications Non Power Driven with 1.3mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not less than 6kg for Industrial use for area upto 100m2 for Industrial use ( CM SR 2023-24/ P.No.38/Vol-2/7.69.3)

81

5880

476280

... More
V-2, P.No.42, I-8.8 - Providing 18mm cement plaster in two coats under layer 12mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with atuoplayer 6mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2023-24 V-2,/P.No.42, I-8.8)

3926.63

389

1529618.7165

... More
Vol-2 8.1.1 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ( CM SR 2023-24/ P.No.40/Vol-2/8.1.1)

15.71

267

4206.3525

... More
Vol-2 8.2.1 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( CM SR 2023-24/ P.No.41/Vol-2/8.2.1)

120.3

309

37262.925

... More
Vol-2 8.3.1 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc-tions of Engineer-in-charge ( CM SR 2023-24/ P.No.41/Vol-2/8.3.1)

19.52

371

7255.584

... More
Vol-2 8.11 - Providing Neat cement punning to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( CM SR 2023-24/ P.No.41/Vol-2/8.11)

73.43

59

4394.7855

... More
Vol-2 8.33.1 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) ( CM SR 2023-24/ P.No.46/Vol-2/8.33.1)

107.79

165

17882.361

... More
Vol-2 9.7.2 - Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ( CM SR 2023-24/ P.No.60/Vol-2/9.7.2)

43.51

113

4934.034

... More
Vol-2 8.30 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2023-24/P.No.46/Vol-2/8.30)

3926.63

182

717395.301

... More
Vol-2 8.28 - Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2023-24/P.No.45/Vol-2/8.28)

17.2

93

1607.34

... More
Vol-2 8.34.1 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( CM SR 2023-24/ P.No47/Vol-2/8.34.1)

4.91

55

273.2415

... More
Vol-2 8.34.3 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( CM SR 2023-24/ P.No47/Vol-2/8.34.3)

5.76

52

302.4

... More
Vol-2 9.7.2 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile ( CM SR 2023-24/ P.No.60/Vol-2/9.7.2)

87.83

1323

116199.09

... More
Vol II I.No. 9.12.2 - Providing and laying vitrified floor tiles (Size of Tile 600x600 mm) (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.(Vol II I.No. 9.12.2 P.No. 60)

11.42

1202

13729.695

... More
Vol-2 12.16 - Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) ( CM SR 2023-24/ P.No100/Vol-2/12.16)

1.89

7816

14772.618

... More
Vol-2 12.7 - Providing Honne wood frames for false ceiling, partitions etc., main battens of size 50x12.5mm at 600mm c/c and cross battons 38mmx50mm at 600 mm c/c sawn and putup including cost of materials, labour complete as per specifications. ( CM SR 2023-24/ P.No99/Vol-2/12.7)

0.05

145412

7270.62

... More
Vol II I.No. 12.84 - Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size

2.88

5274

15189.552

... More
Vol-2 12.55.1 - Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges do- with both side prelam ( CM SR 2023-24/ P.No.104/Vol-2/12.55.1)

10.08

2484

25041.744

... More
Vol-2 12.54 - Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge ( CM SR 2023-24/ P.No.104/Vol-2/12.54)

34.8

333

11619.72

... More
Vol-2 12.85 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mmthickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass.

3.24

6004

19456.038

... More
Vol-2 - Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

5

5128

25641

... More
Vol V I.No. 60.1 - Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete. 110m dia (Vol V I.No. 60.1 P.No. 202)

2

8214

16428.3

... More
Vol V I.No. 16.10 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (Vol V I.No. 16.10 P.No. 191)

5

4133

20669.25

... More
v-2 I.No. 13.34 - Providing and placing on terrace(at all floor levels) polethylene water storage tanks, IS:12701 marked, with cover and suitable locking arrangements and making neccesary holes for inlet, outlet and overflow pipes but without fittings and base support for tank v-2 I.No. 13.34)

4000

9

37800

... More
Vol II I.No. 13.22.1.1 - Providing and fixing PTMT grating of approved quality and colour.100 mm nominal dia (Vol II I.No. 13.22.1.1 P.No. 118)

10

43

430.5

... More
Vol II I.No. 13.8.2.1 - Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 15mm Nominal Bore(Vol II I.No. 13.8.2.1 P.No. 118)

10

95

955.5

... More
Vol II I.No. 13.17.2 - PProviding and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 122mm long, weighing not less than 99 g(Vol II I.No. 13.17.2 P.No. 120)

10

221

2215.5

... More
Vol II I.No. 13.3.0 - Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having therma stability for hot & cold water supply, including all cpvc plain and brass threaded fittings, i/c fixing the pipes with clamps at 1.00m spacing, this includes joiting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and maiking good the same including testing of joints complete as per direction of Engineer in-charge. Conceled work, including cutting chases and making good the wall etc.15mm nominal dia pipes. Vol II I.No. 13.3.0P.No. 122)

125

191

23887.5

... More
Vol II I.No. 13.3.3 - Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having therma stability for hot & cold water supply, including all cpvc plain and brass threaded fittings, i/c fixing the pipes with clamps at 1.00m spacing, this includes joiting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and maiking good the same including testing of joints complete as per direction of Engineer in-charge. Conceled work, including cutting chases and making good the wall etc.25mm nominal dia pipes. Vol II I.No. 13.3.3P.No. 122)

125

333

41737.5

... More
Vol V I.No. 1.6 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 (Vol V I.No. 1.6 P.No. 134)

110

308

33957

... More
Vol V I.No. 1.6.1 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 (Vol V I.No. 1.6 P.No. 134) 75mm Dia

20

231

4620

... More
Vol II I.No. 15.1 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (Vol II I.No. 15.1 P.No. 134)

17.96

857

15406.986

... More
Vol II I.No. 14.7.3 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15mm C.P. brass pillar taps(Vol II I.No. 14.7.3 P.No. 132)

8

2689

21512.4

... More
Vol II I.No. 14.40.2 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm andeffective height of 88 mm, weighing not less than 190 g.(Vol II I.No. 14.40.2 P.No. 130)

8

520

4166.4

... More
Vol-2 11.25.2 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (CM SR 2023-24/P.No.84/Vol-2/11.25.2)

29410

142

4199748

... More
Vol-211.34B - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ( CM SR 2023-24/ P.No86/Vol-2/11.34B)

60.48

192

11621.232

... More
Vol-2 11.6.1 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CM SR 2023-24/P.No.78/Vol-2/11.6.1)

90.23

2764

249454.3695

... More
Vol-2 11.8.4 - Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CM SR 2023-24/P.No.79/Vol-2/11.8.4)

4

25920

103681.2

... More
Vol-2 8.33.3 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CM SR 2023-24/P.No.45/Vol-2/8.33.3)

1417.22

145

206843.259

... More
Vol-2 12.57.3 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial (CM SR 2023-24/P.No.105/Vol-2/12.57.3)

7.35

3155

23191.0875

... More
Vol-2 12.61 - Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (CM SR 2023-24/P.No.105/Vol-2/12.61)

8

1039

8316

... More
Vol-2 12.62 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (CM SR 2023-24/P.No.105/Vol-2/12.62)

4

248

995.4

... More
Vol-1 2.5.3 - Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (CM SR 2023-24/P.No.16/Vol-1/2.5.3) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for plinth beam and slab

35.64

11036

393323.7528

... More
Vol-1 2.5.3 - Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for columns

273.01

12507

3414672.575

... More
Vol-1 2.5.3 - Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for lintels and beams

174.44

11771

2053465.8144

... More
Vol-1 2.5.3 - Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (CM SR 2023-24/P.No.16/Vol-1/2.5.3) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for chejjas

0.5

10668

5334.08

... More
Vol-1 2.5.3 - Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (CM SR 2023-24/P.No.16/Vol-1/2.5.3) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Slab for soak pit 15.4

0.52

10442

5429.97

... More
Vol-1 2.11 a - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (CM SR 2023-24/P.No.18/Vol-1/2.11 a)

125.35

93929

11774106.6975

... More
Vol II I.No.8.33.2 P.No. 46 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer

4.91

144

711.459



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.