Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Civil And Construction
Water Storage And Supply
Opening Date3 Sep 2024
Closing Date12 Sep 2024
Tender Amount₹ 64,86,800.03 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For-PVC pipes 110mm dia., 6 kg/sqcm &class 3(Page No.113. Iitem no.10.1.7 of Vol-5-CSR-KPWD 2023-2024)

1250

423

529162.5

... More
code05 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For-PVC pipes 90mm dia., 6 kg/sqcm &class 3(Page No.113. Iitem no.10.1.6 of Vol-5-CSR-KPWD 2023-2024)

1350

302

408807

... More
code06 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with lectrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete(Page No.22. Iitem no.2.23 of Vol-5-CSR-KPWD 2023-2024)For sluice Valve of PN10.0 and 150mm

15

18014

270220.5

... More
code07 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with lectrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete(Page No.22. Iitem no.2.23 of Vol-5-CSR-KPWD 2023-2024)For sluice Valve of PN - 10.0 and 100mm

20.833

11210

233548.76316

... More
code08 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with lectrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete(Page No.22. Iitem no.2.23 of Vol-5-CSR-KPWD 2023-2024)For sluice Valve of PN -10.0 and 80mm

20

10704

214095.8

... More
code09 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cm in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications(Page No.35. Iitem no.1.10 of Vol-1-CSR-KPWD 2023-2024)

1944

164

320371.2

... More
code10 - Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of ontractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804(Page No. 151, I.No. 4 of KPWD S.R 2023-24). Volume3

3

9270

27810

... More
code11 - Providing and laying of a reinforced cement concrete pipe duct,300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills,constructing head walls at both ends, providing a minimumfill of granular material over top and sides of RCC pipe as perIRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.Single row for one utility service(Page No. 71, I.No. 8.29.1 of KPWD S.R 2023-24). Volume3

70

2278

159485.2

... More
code12 - Providing and Fhing of 11KV LBS pole assembly for Brezicuer MH VCB 3.3KV 110 Volts

6

31200

187200

... More
code13 - Providing and Fixing of 11KV LBS pole insulater for Breaker MH VCS 3.3KV 110 volts

12

6400

76800

... More
code14 - Providing and Fixing of 230volt Ac Spring Charge Motor for Breaker MH VCB 3.3KV 110 volts

2

46800

93600

... More
code15 - Providing and Fixing of 11KV Moving & fixed arm for Breaker MiH VCD 3.3k 110 volts

1

32000

32000

... More
code16 - Providing and Fixing of 11KV LBS fuce 10a din type for Breaker MH VCB 3.3k 110 volts

6

9600

57600

... More
code17 - Providing and Fixing of 32A HRC Fuse 85 type

6

16700

100200

... More
code18 - Providing and Fixing of Auxiliary Switch for 1.3Kv 500P FCMA Starter Penal Jou Starter (Vacuum contactor).

4

28000

112000

... More
code19 - Providing and Fixing of 3.3KV 258KVAR Capacitor Sank

516

432

222912

... More
code20 - Providing and fixing of close coll Unic for Kv 300hp ICMA Starter Punal iyesi Starter (Vacuum contactor)

4

28000

112000

... More
code21 - Providing and Fixing of trip coll Unit for 3.3Kv 500 FCMA Starter Penal Jyot Starter (Vacuum contactor

4

28000

112000

... More
code22 - 630 Kva transformer Rewinding: Providing 630 te copper now wind in place el 10 damaged winding cust of materials, labour drying etc. IV-Side HV Winding (All the above rates are after deducting the scarp material cost

264

1250

330000

... More
code23 - Providing 630 Kva copper wind in place of damaged winding cost of 11 materials, labour drying ett. LV-Sice LV Winding (All the above rates are after deducting the scarp material cost)

178

1480

263440

... More
code24 - HV Porcelain Rushings.

3

350

1050

... More
code25 - HV Termirnal Bolts with 4 nuts & wash.

3

526

1578

... More
code26 - LV Bushing

4

536

2144

... More
code27 - LV Terminal Bolts with 4 nuts & wash.

4

2016

8064

... More
code28 - Top cover gasiet and gasket of oil gauge, breather cap, oif cap etc.

1

1700

1700

... More
code29 - HV/LV red gasket eg: flat gasket, D bush, cone bush

6

405

2430

... More
code30 - Breather with Silica Gel

1

1220

1220

... More
code31 - Tap changer with accessories

1

3563

3563

... More
code32 - Oil Level indicator with Glass.

1

726

726

... More
code33 - core Bolt with Insulation

18

310

5580

... More
code34 - Insulating materials such as press board, cotton tape, kraft paper

25

410

10250

... More
code35 - Out side painting of Transformer body & Conservator Tank

1

3920

3920

... More
code36 - MS bolts and nuts washers spring washers of different size.

1

130

130

... More
code37 - Soldering Lead-Fulx Brazing Rod.

1

3700

3700

... More
code38 - SRBP Tube

28

45

1260

... More
code39 - Replacement of deterioarated breack down valve and corbon contaminated EHV grade oil supplying & Topping up of new transil Oil (Rate should be Considered after deducting Deteriorated oil)

550

192

105600

... More
code40 - Loading and Unloading & 630KVA transportation of repaired transformers from work shop to work spot to Jack well & unloading the existing platform with help of 10 Ton capacity hydro crane carefully without damaging to the parts.

1

30000

30000

... More
code41 - Drying of active parts by ovening for 48 to 72 hours at 90 to 100 C temperature for removal of Moisture of the Repaired Transformer.

1

12000

12000

... More
code42 - Testing and Commissioning charges.

1

16000

16000

... More
code43 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia, with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2" 0 rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. 80 mm dia PN 25 (Bwssb shedule rate Page no 72 SL no 27.2 SOR code B075B)

1

20576

20576

... More
code44 - Removing of Existing parts for 475 hp FCMA Soft starter and Providing and fixing of PLC with HMI 1 No, Under current relay 1 No, Control relay 8 No, CURRENT TRANSFORMER CT-1 Core -1 CL 7.5VA for metering 100/1 A 3 No, Core -1 CL 7.5VA for metering 600/1 A 1 No, Digital Ammeter 0-600A 1 No, Space Heater 40W,230V AC 1 No, and wherever required with extra Nut Control relay bolts, and including cost of Rewiring all material & complete as directed by the Engineer-in- Charge.

1

187000

187000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.