Directorate Of Municipal Administration Tender
... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 51,700Document Cost
Refer DocumentsTender Fee
₹ 550
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/EL/WORK_INDENT35937/CALL-2Tender No
DMA/2024-25/EL/WORK_INDENT35937/CALL-2Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
004 - Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14stage microprocessor operation, relays LED display, self programming function for power stages and operating logicchecking facilityfor healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long termmemory for settings, protection for over voltage, power factor correction fault andnovoltage, to connect/ disconnect banks, with automatic recognition or with standard programs
1
22722
22722
... More
005 - Supply, installation, testing & commissioning of Occupancy Sensor Switch:-Surface Mount with movement detector with built-in switch. It willswitch off the lights in aroomor area when it is vacated and thus save upto 30% of electrical energy The Occu switch Surface Mount can switch any load upto 6A, Device mounting heights between 2.5 and 3.5 meter, for movement detection covering anarea of 4 to 5 square meters (desk work) and 6 to 8 meters for larger movements like walking(at 25 deg Ce ambient). "Functions-Automatic control of lights/electrical load switch ON/OFF automatically when any movement is detected, with adjustabl time settings for Switch ON/OFF (30 seconds to30 minutes).Red LED indicator on detection of movement."Smart timer-The smart timer wil extend the delay timeby the set delay time if movement is detected shortly after switch off, assuming that the area is still in use, but very little movement is made. "Power Supply-Voltage 230 V +/1 0%,. 50/60HzAC Supply,.Maximum load 6 A. (1440 VA) any load, . Maximum wire range 0.75 to 1.5mm2, .Mains distribution system T S with Neutral grounded,."
15
3360
50400
... More
006 - Supplying of .feet-PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along withCE approved. 2 year Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W
300
724
217350
... More
007 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of
round blocks and clamps. On wall/ ceiling / Rafter / Girders
300
128
38430
... More
008 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor
0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans).48" Sweep 5 Star (1200 mm)
133
2810
373843.05
... More
009 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
133
179
23880.15
... More
010 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W Syste Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 120W
2
11294
22589.7
... More
011 - Supplying and fixing/replacement of Round/ Conical/ Diamond shaped HDPE Doom suitable for 125/160W post top lamp fittings.
2
2686
5373.9
... More
012 - Fabricating supplying and mounting MS box made out SWG
suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG
80000
-
36000
... More
013 - Supplying, fixing andwiring heavy duty lowvoltage capacitors conforming toIS2834. 3phase, 400/440Vgrade, for power factor improvement of rotating machineries like induction motor.
100
504
50400
... More
014 - Supplying &fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898. 6-32 A TPN
9
1802
16225.65
... More
015 - Supplying of multi function digital meter with three line back light LCD type display for voltage,Current, frequency, Power, power factor, kVA, kWH, kVARsuitable for 3phase,4wire LT networ with IP54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
1
9780
9780.75
... More
016 - Rotary handle for MCCB
1
3935
3935.4
... More
017 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole. 250 A 36 kA
1
24722
24722.25
... More
018 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)
0.2
391875
78375.15
... More
019 - Supply and fixing of 3-pole Capacitor switching contactor with NO/NCcontacts and in built damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 60947-4-1.12.5 KVAR
4
3046
12184.2
... More
020 - Supply and fixing of 3-pole Capacitor switching contactor with NO/NCcontacts and in built damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 60947-4-1. 22 KVAR
1
4806
4806.9
... More
021 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP
10
775
7759.5
... More
022 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 Sqmm
200
27
5460
... More
023 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 Sqmm
80
44
3528
... More
024 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6Sqmm
120
96
11592
... More
025 - Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W
30
1390
41706
... More
026 - Aluminium End Terminal (Lug).95 Sqmm
12
15
189
... More
027 - Supplying . A rated 3phase with neutral bus bar using
required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete250 A 4 x 30 x 10 mm Aluminium Strips
15
3606
54101.25
... More
028 - Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.
1
2023
2023.35
... More
029 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT
4
1788
7152.6
... More
030 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.
20
540
10815
... More
031 - Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.
1500
-
555
... More
032 - Supply, installation, testing and commissioning of analogue addressable dual heat detector and standard base, It shall have multiple modes with min five different heat sensitivity adjustment from 57 Degree to 90 Degree fo static response while working on Rate of Rise response. 360 deg VisibleTr coloured led for Normal, Fault and alarm condition, addressing shall be by means of Soft addressingor dip switches or decade switches, or suitable punched cards. (For Detectors/Device with out inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: UL/VDS/EN54.
1
3465
3465
... More
033 - ABC Powder Type Fire Extinguisher. 6 Litre
8
5183
41470.8
... More
034 - FIRE FIGHTING EQUIPMENT. DCP Type. 4.5 kg
8
5366
42932.4
... More
035 - Supplying and installation of RUBBER MAT 1mtrx1mtr-1Omm thick. complete including cost of materials, labour, usage charges of machinery complete as per specifications
5
1995
9975
... More
036 - Caution/Danger Board
8
157
1260
... More
037 - Fixing Danger Board
8
84
672
... More
038 - Opeartion and Maintanance of light source High Pressure 250 Watts Metal halide flood light luminary includes supply and replacement of all components / materials such as lamps , chokes, ballasts, starters, condesners, ignitors, side holders, etc. in completer manner including cost of labour and material as directed by the engineer in charge
8
2110
16880
... More
039 - Opeartion and Maintanance of High Pressure 400 Watts Metal halide flood light luminary includes supply and replacement of all components / materials such as lamps , chokes, ballasts, starters, condesners, ignitors, side holders, etc. in completer manner including cost of labour and material as directed by the engineer in charge
6
2477
14862
... More
040 - Operation and Maintenance of Exhaust fan including rewinding of exhaust fan of all size with brackets blades etc, in completer manner including cost of labour and material as directed by the engineer in charge
35
454
15890
... More
041 - Operation and maintenance of AC One TR/Two TR/ Three TR including repair of sealed compressor/air cooled condenser, repair and replacement of ,motor capacitor and start run capacitors, relay and over load protector internal unit refilling of coolant etc, in complete manner including cost of labour and material as directed by the engineer in charge
43
7865
338195
... More
042 - Operation and Maintenance of Central control unit having powers up to 60 microphone units and supports up to 250 units. Also supports 2 language channels. Two analog audio inputs for external sources such as wireless microphones, and 8 analog audio outputs for connection to videoconferencing system, A/V recording equipment, supplemental sound reinforcement system, or wireless language distribution system.Fully digital audio transmission of floor plus 31 interpretation channels and 8 conference microphone audio channels in a single digital bus cable structure using shielded CAT5e cables in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material.
2
32500
65000
... More
043 - Operation and Maintenance of Power Supply for Central Control Unit (CCU) models and adheres to energy-efficient power standards in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material
2
24550
49100
... More
044 - Operation and Maintenance of two-channel recorder/player for network applications should have SD card recorder/players for virtually any installation. Extensive I/O including balanced, unbalanced and DANTE interconnectivity are joined by a microphone preamp with phantom power and ducking. Audio may be recorded to SD Card or USB stick and uploaded automatically to your desired FTP server. In addition, recording and playback can be controlled via SNTP, network control, the optional RC-SS150 remote control or the free iOS/Android app in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material
2
38500
77000
... More
045 - Operation and Maintenance of 2 ways ACTIVE top unit for PA, should have Compact 2-way FOH system, Multi-functional and lightweight, Suitable for mobile, portable use, Fixed installation, Mirror monitor configuration, Compatible with Powerdrive accessories, Tiltable flange in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material
1
18900
18900
... More
046 - Operation and Maintenance of Digital Processor, Highend A/D and D/A converters, 2 Inputs / 6 Outputs; Matrix routing, Crossover, EQ, Delay, Phase, Noise gate and Limiter Functions on Each Output, Crossover slope: 12dB, 18dB, 24dB, 48dB per octave, Crossover types: Linkwitz-Riley, Bessel and Butterworth Filters, 6 bands EQ through output stage. EQ types: parametric, low shelf, high shelf, Up 7ms maximum delay time for output delay, step 21ms, Full parameters for limiter: attack, release, threshold and hold time, Full parameters for noise gate: attack, release and threshold, Polarity reverse control on each output, 16 user memories, friendly user interface, Programmable by rear panel, USB, XLR Audio Connections, Balanced Inputs and Outputs, 220 characters LCD with backlight and Switch Power Supply: 90250V.in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material
2
23500
47000
... More
047 - Operation and Maintenance of power conditioner with highest level of surge & spike protection available. Noise Filtration LiFT offers AC power filtering to ensure clean power for unequaled audio & video clarity.Front panel USB Charger to charge most media devices or power a USB lamp. Voltmeter / Ammeter Large digital voltmeter / ammeter, with discrete dimmer button, displays line votlage and true RMS current draw. Isolated Banks Isolated outlet banks minimize inter-component interference and noise contamination. 16 AMP Rating 16 Amp rating featuring a high inrush magnetic circuit breaker for added protection. 11 Total Outlets (10 rear panel outlets and one front panel convenience outlet). BNC Lamp Connector Rear panel BNC connector powers any standard gooseneck lamp for rear rack illumination in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material
3
25000
75000
... More
048 - Periodic Checking and testing of Distilled water for existing UPS batteries
2000
25
51000
... More
049 - Periodic Checking and replacement of Air/ fuel/oil filter of the existing Diesel Genarator set as per the standard maintenance schedule.
6
1875
11250
... More
050 - Operation and Maintenance of 100 KVA Diesel-Generator set (Fuel tank, stator motor, batteries, control panel, accoustic enclosures) and its engine systems(Air, lube, fuel system), consumables like Air filter, engine oil, batteries servicing, AMF panel, etc including periodic cleaning of DG Set enclsoures from dust in complete manner - as per the direction of Engineer-in-charge of the work - SHOULD HAVE VALID ELECTRICAL LICENSES
1
10800
10800
... More
051 - Work of servicing, leak arresting and oil filtration upto 400 KVA power transformers as specified below: a. Removing cable connection of transformer after isolating the supply dismantling the cable connection b. Replacing the existing leakage L.V side H.T Busing Gasket, oil seal, bots and nuts etc. of the power transformer. c. Replacing the existing non-functioned damaged Dehydrating Breather by a new breather with new silica gel for the above transformer d. Arresting oil leak from exclusive vent, neutral bushing of valves, flanges, is drying arresting the leakage for L.V and HV side of power transformer and refilling of the transformer oil including cost of labour and necessary repaired materials. e. Repaint the Transformer using light grey epoxy paint of 2 coated as original. f. Filtering of oil in the transformer at the transformer center by hot process using stream line filter such that the dielectric strength of oil in the transformer conforms to ISI specification. g. Painting of entire structure of transformer yard including fencing using silver paint.
1
73017
73017
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%