Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Electrical and Electronics
Electrical Works
Opening Date26 Jul 2024
Closing Date12 Aug 2024
Tender Amount₹ 23,96,862.99 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 3C x 4 mm2

170

180

30702

... More
code05 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work

6

107

642.6

... More
code06 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates

0.6

6288

3773.07

... More
code07 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - For Buildings PWD CSR 2023-24, Vol-I, P. No. 18, I. No. 2.11a

0.04

93929

3757.194

... More
code08 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

4

9800

39202.6

... More
code09 - Nut and Bolts and Fittings (25mm 1mtr length)

47

150

7050

... More
code10 - Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.

4

5085

20340.6

... More
code11 - Earthing GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip

40

86

3444

... More
code12 - LT Cable 2.5 to 25 Sqmm (Single/3.5/4 Core)

7.5

1246

9347.625

... More
code13 - Providing and fixing of LED Street Light of IS Standards Input Operating voltage range: 100-300V AC universal electronic driver with internal surge protection of 4 KV (Applicability IS 15885, Driver Safety 16104-1-2) and Power cut-off arrangement in case of phase-to-phase 440 V fault, AC Input operating frequency range: 50 HZ+3%, Average rated late span of LEDs used in the luminaries: More than 50,000 hrs., case temperature of 100C with respect to lumen maintenance of 70, Interchangeability: Suitable for pole mount, Total Harmonic Distortion for the complete fixture: 10, Ambient Temperature: 10C to +60C, Working Temperature: 5C to +60C, Working Humidity: 10 to 90% RH, Correlated Colour Temperature (CCT): 500 K (ANSI-NEMA) Wattage-Design: One Watt minimum, Wattage-all operating current: One Watt minimum, LED efficiency (Im W) (at operating current (design) and T)= 85 deg C): More than 135 lumens/watt, Luminaries Efficiency 1) A1/A2 Roads as per IS 1944 a) 90 watts b) 110 watts c) 120 watts d) 150 watts e) 180 watts f) 240 watts, 2) B1/B2 Roads as per IS 1944 a) 18 watts b) 24 watts c) 43 watts d) 65 watts 3) Floodlights, a) 60 watts b) 90 watts c) 110 watts d) 120 watts d) 150 watts: More than 100 lumens/watt, Colour Rendering Index of LEDs: 70, Power factor : More than 0.95, Driver Efficiency 85 Leeds shall be operated at a forward current 70 of rated maximum forward current in the range of 350mA to 1000mA, Surge suppresser: Internal voltage surge protection: Universal electronic driver with internal surge protection of 4KV Applicability IS 15885, driver safety 16104-1-2 Extremal voltage surge protection: External surge protection derive (SPD) with a minimum of 11KV 10 KA shall be separately installed with each fixture, Finishing: Corrosion free High pressure aluminum grey silver colour corrosion resistant polyester powder coating, Heal sink: Good thermal management System should he provided & LED must be mounted on high pressure die cast aluminum casting with sun table large surface area by Means of fins to dissipate the heat to ambient air., Corrosion resistant LT grey Silver Nano powder coating, Silicon gasket to ensure ingress protection against moisture & dust., Ingress protection Optical & Control great compartment IP-66 CPRI/NABL accredited lab test certificate shall be furnished at the time of inspection of materials at works, Cover gals Lens core Cover frame: Glass- Distortion free, clear, heat resistant roughened UV stabilized glass, Lens cover- Lens should be of martial resistant to degradation during service due to atmospheric components, to avoid adverse impact on Hight output., Cover frame Aluminium cover fixed t the housing by means of rust proof 304 grade stainless steel screws., Lens module for LEDs The luminaries shall be suitable for operation within the input supply voltage range specified The driver of the light should be above to sense and cut off power to the light mease of phase to phase 440 W fault, BIS Marl: LED street light flood light and electronic driver shall have Standard BIS Mark and registration number as below. Embossment Luminaries shall have company name Logo Embossed on the housing. Stickering is not allowed Warranty 10 Years 65 Watts As per DMA Order No. 25775 DMA 69 DEVT 2018-19 Dt: 03-01-2019 All Terms and Condition apply

20

4550

91000

... More
code14 - Providing and fixing of LED Street Light of IS Standards Input Operating voltage range: 100-300V AC universal electronic driver with internal surge protection of 4 KV (Applicability IS 15885, Driver Safety 16104-1-2) and Power cut-off arrangement in case of phase-to-phase 440 V fault, AC Input operating frequency range: 50 HZ+3%, Average rated late span of LEDs used in the luminaries: More than 50,000 hrs., case temperature of 100C with respect to lumen maintenance of 70, Interchangeability: Suitable for pole mount, Total Harmonic Distortion for the complete fixture: 10, Ambient Temperature: 10C to +60C, Working Temperature: 5C to +60C, Working Humidity: 10 to 90% RH, Correlated Colour Temperature (CCT): 500 K (ANSI-NEMA) Wattage-Design: One Watt minimum, Wattage-all operating current: One Watt minimum, LED efficiency (Im W) (at operating current (design) and T)= 85 deg C): More than 135 lumens/watt, Luminaries Efficiency 1) A1/A2 Roads as per IS 1944 a) 90 watts b) 110 watts c) 120 watts d) 150 watts e) 180 watts f) 240 watts, 2) B1/B2 Roads as per IS 1944 a) 18 watts b) 24 watts c) 43 watts d) 65 watts 3) Floodlights, a) 60 watts b) 90 watts c) 110 watts d) 120 watts d) 150 watts: More than 100 lumens/watt, Colour Rendering Index of LEDs: 70, Power factor : More than 0.95, Driver Efficiency 85 Leeds shall be operated at a forward current 70 of rated maximum forward current in the range of 350mA to 1000mA, Surge suppresser: Internal voltage surge protection: Universal electronic driver with internal surge protection of 4KV Applicability IS 15885, driver safety 16104-1-2 Extremal voltage surge protection: External surge protection derive (SPD) with a minimum of 11KV 10 KA shall be separately installed with each fixture, Finishing: Corrosion free High pressure aluminum grey silver colour corrosion resistant polyester powder coating, Heal sink: Good thermal management System should he provided & LED must be mounted on high pressure die cast aluminum casting with sun table large surface area by Means of fins to dissipate the heat to ambient air., Corrosion resistant LT grey Silver Nano powder coating, Silicon gasket to ensure ingress protection against moisture & dust., Ingress protection Optical & Control great compartment IP-66 CPRI/NABL accredited lab test certificate shall be furnished at the time of inspection of materials at works, Cover gals Lens core Cover frame: Glass- Distortion free, clear, heat resistant roughened UV stabilized glass, Lens cover- Lens should be of martial resistant to degradation during service due to atmospheric components, to avoid adverse impact on Hight output., Cover frame Aluminium cover fixed t the housing by means of rust proof 304 grade stainless steel screws., Lens module for LEDs The luminaries shall be suitable for operation within the input supply voltage range specified The driver of the light should be above to sense and cut off power to the light mease of phase to phase 440 W fault, BIS Marl: LED street light flood light and electronic driver shall have Standard BIS Mark and registration number as below. Embossment Luminaries shall have company name Logo Embossed on the housing. Stickering is not allowed Warranty 10 Years 43Watts As per DMA Order No. 25775 DMA 69 DEVT 2018-19 Dt: 03-01-2019 All Terms and Condition apply

257

3440

884080

... More
code15 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2

1049

44

46260.9

... More
code16 - Supplying and Fixing of 25mm dia class A GI pipe bracket upto 1 ms long bent at suitable angle and fixing to this bracket street ligh tfitting of all capacities to GI or GIorrailor RCC pole/wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe

277

500

138500

... More
code17 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

259

107

27738.9

... More
code18 - Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m lengthfitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, withlocking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7. 9m(5mHb, 165.1mm dia 4.85mm thick x2m Hm, 139.7mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 32 Erection of heavy duty Pole on Footpath/median

15

16275

244125

... More
code19 - Providing and fixing of LED Street Light of IS Standards Input Operating voltage range: 100-300V AC universal electronic driver with internal surge protection of 4 KV (Applicability IS 15885, Driver Safety 16104-1-2) and Power cut-off arrangement in case of phase-to-phase 440 V fault, AC Input operating frequency range: 50 HZ+3%, Average rated late span of LEDs used in the luminaries: More than 50,000 hrs., case temperature of 100C with respect to lumen maintenance of 70, Interchangeability: Suitable for pole mount, Total Harmonic Distortion for the complete fixture: 10, Ambient Temperature: 10C to +60C, Working Temperature: 5C to +60C, Working Humidity: 10 to 90% RH, Correlated Colour Temperature (CCT): 500 K (ANSI-NEMA) Wattage-Design: One Watt minimum, Wattage-all operating current: One Watt minimum, LED efficiency (Im W) (at operating current (design) and T)= 85 deg C): More than 135 lumens/watt, Luminaries Efficiency 1) A1/A2 Roads as per IS 1944 a) 90 watts b) 110 watts c) 120 watts d) 150 watts e) 180 watts f) 240 watts, 2) B1/B2 Roads as per IS 1944 a) 18 watts b) 24 watts c) 43 watts d) 65 watts 3) Floodlights, a) 60 watts b) 90 watts c) 110 watts d) 120 watts d) 150 watts: More than 100 lumens/watt, Colour Rendering Index of LEDs: 70, Power factor : More than 0.95, Driver Efficiency 85 Leeds shall be operated at a forward current 70 of rated maximum forward current in the range of 350mA to 1000mA, Surge suppresser: Internal voltage surge protection: Universal electronic driver with internal surge protection of 4KV Applicability IS 15885, driver safety 16104-1-2 Extremal voltage surge protection: External surge protection derive (SPD) with a minimum of 11KV 10 KA shall be separately installed with each fixture, Finishing: Corrosion free High pressure aluminum grey silver colour corrosion resistant polyester powder coating, Heal sink: Good thermal management System should he provided & LED must be mounted on high pressure die cast aluminum casting with sun table large surface area by Means of fins to dissipate the heat to ambient air., Corrosion resistant LT grey Silver Nano powder coating, Silicon gasket to ensure ingress protection against moisture & dust., Ingress protection Optical & Control great compartment IP-66 CPRI/NABL accredited lab test certificate shall be furnished at the time of inspection of materials at works, Cover gals Lens core Cover frame: Glass- Distortion free, clear, heat resistant roughened UV stabilized glass, Lens cover- Lens should be of martial resistant to degradation during service due to atmospheric components, to avoid adverse impact on Hight output., Cover frame Aluminium cover fixed t the housing by means of rust proof 304 grade stainless steel screws., Lens module for LEDs The luminaries shall be suitable for operation within the input supply voltage range specified The driver of the light should be above to sense and cut off power to the light mease of phase to phase 440 W fault, BIS Marl: LED street light flood light and electronic driver shall have Standard BIS Mark and registration number as below. Embossment Luminaries shall have company name Logo Embossed on the housing. Stickering is not allowed above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Post Top Lantern with 15/20 W

15

7268

109021.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.