Directorate Of Municipal Administration Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction
Civil Works Others
Opening Date20 Feb 2025
Closing Date21 Mar 2025
Tender Amount₹ 8,00,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
cmy04 - Taking out doors windows and clerestory window shutters steel or wood including stacking to the appropriate disposal area as per direction of Engineer in charge Of area beyond 3 m2 with all lead and lift and directions of the Engineer In charge of the work

24.12

126

3055.7628

... More
cmy05 - Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in charge with all lead and lift and directions of the Engineer In charge of the work

67.81

496

33664.9526

... More
cmy06 - Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer in charge. For thickness of tiles 10 mm to 25 mm with all lead and lift and directions of the Engineer-In-charge of the work

75.65

49

3740.136

... More
cmy07 - CIVIL WORKS Earth work excavation for Foundation by Mechanical means depth upto 1.50m as per drawing and technical specifications, including setting out shoring strutting barricading caution lights including cost of explosives dressing of excavated surfaces disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour blasting materials tools usage of Machinery and all other appurtenaces required to complete the work In Hard Rock requiring blasting Depth upto 1.50m with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Spetic Tank

710.73

105

74669.2938

... More
cmy08 - Earth work excavation by manual means for drains canals waste weir draft approach channels key trench foundation of Bridges and such similar works as per drawing and technical specifications including setting out shoring strutting barricading caution lights excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage and other appurtenances required to complete the work In ordinary soft rock without blasting upto 1.5 m depth with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Spetic Tank

142.15

570

81113.633

... More
cmy09 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In ordinary soft rock without blasting upto 1.5 m depth with all lead and lift and directions of the Engineer In charge of the work Entrance Arch

29.94

373

11194.2666

... More
cmy10 - Providing and injecting chemical emulsion for Pre constructional Anti Termite Treatment creating continuous chemical barrier under and around the column pits walls trenches basement excavatio top surface of the plinth filling junction of wall and floor along the external perimeter of building expansion joints over the top surface of consolidated earth on which apron is to be laid surrounding of pipes and conduits with chloropyriphos emulsifiable concentrates of 20 prencetage concentration including cost of chemical diluting in water to one percent concentration labour HOM of equipments, complete as per specifications Plinth area of the building at ground floor only shall be measured Ground Floor

344.13

121

41825.5602

... More
cmy11 - Providing and laying in position plain cement concrete for levelling course for all works in foundation The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications.Mix 1 4 8 Using 40 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Ground Floor

34.89

5833

203545.4688

... More
cmy12 - Providing and laying in position plain cement concrete for levelling course for all works in foundation The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications Mix 1 3 6 M10 Using 40 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Spetic Tank Entrance Arch

146.97

6168

906609.4299

... More
cmy13 - Filling available excavated earth excluding rock in trenches plinth sides of foundations and other similar works etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mwith all lead and lift complete as per specifications Ground Floor Ritual Hall Entrace Arch

417.14

273

114288.0172

... More
cmy14 - Filling approved earth excluding rock in trenches plinth sides of foundations and other similar works etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m with all lead and lift complete as per specifications Ground Floor

244

445

108821.56

... More
cmy15 - Providing and laying in position Reinforced cement concrete for all Foundation works The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Ground Floor Footing

93.46

7048

658721.9682

... More
cmy16 - Providing and laying in position Reinforced cement concrete for all Foundation works The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all lead and lift and directions of the Engineer In charge of the work Entrance Arch Footing

5.4

6852

37002.852

... More
cmy17 - Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1 6 1 cement 6 coarse sand with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Entrance Arch

113.32

6580

745721.5244

... More
cmy18 - Providing and laying in position Reinforced cement concrete for all Foundation works The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all lead and lift and directions of the Engineer In charge of the workGround Floor Ritual Hall Entrance Arch Plinth Beam

37.75

9789

369539.28

... More
cmy19 - Providing and laying in position Reinforced cement concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Ritual Hall Flooring

97.45

6828

665476.305

... More
cmy20 - Providing and laying in position Reinforced cement concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specificationsM25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer-In-charge of the work Ground Floor Pedestal Concrete

41.16

11982

493182.8244

... More
cmy21 - Providing and laying in position Reinforced cement concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Roof slab and Stair case

31.31

10572

331023.0964

... More
cmy22 - Providing and laying in position Reinforced cement concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Entrance arch Roof Beam Lintel and Ramp

56.07

11277

632315.9682

... More
cmy23 - Providing and laying in position cement concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators The cost includes all lead and lifts cost of all materials, quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Ground Floor Retaining Wall

28.99

7753

224762.9488

... More
cmy24 - Providing and laying in Reinforced cement concrete for all Basement and surface level works return walls, retaining walls, sunken floors etc The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators providing weep holes wherever necesary including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Spetic Tank

5.1

7341

37443.384

... More
cmy25 - Supplying fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery labour cleaning straightening cutting bending hooking laping welding joints tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification with all lead and lift and directions of the Engineer In charge of the work Ground floor Ritual Hall Spetic tankEntrance Arch

36.24

92140

3339179.3304

... More
cmy26 - Providing and constructing load bearing wall with concrete solid blocks having block ebsity not less than 1800 kg pre m3 Having aq minimum average compressive strength of 5.00 Nmm2 confirming to IA 2185 Part q 2005 and constructed with CM 1 4 as per IS 2572 2005 including cost of all materials labour charges scaffolding curing hire charges of machineries etc as per specifications Solid concrete blocks of Size 400x200x200 mm with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Spetic tank

1052.48

1349

1420111.264

... More
cmy27 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg prem3 and minimum compressive strength of 4.00 N pre mm2 conforming to IS 2185 Part I 2005 and constructed with CM 1 4 as per IS 2572 2005 including cost of all materials labour scaffolding and curing usage charges of machinery etc complete as per specifications with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

52.33

1137

59505.4896

... More
cmy28 - Providing and laying in position Reinforced cement concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers well compacted using needle vibrators The cost includes all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Chajja

2.75

10220

28105.055

... More
cmy29 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix 1 4 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing andremoving scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Ceiling

38.17

321

12266.3112

... More
cmy30 - Providing 12 mm cement plaster with cement mortar 1 4 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge with all lead and lift and directions of the Engineer In charge of the work SpeticTank

6

262

1575.9

... More
cmy31 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1 4 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall

1391.29

359

500127.0163

... More
cmy32 - Providing 20 mm cement plaster with cement mortar 1 3 1 cement 3 coarse sand finished with a floating coat of neat cement to brick stone masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding, including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Spetic Tank Entrance Arch

956.55

441

422670.7485

... More
cmy33 - Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge Applying priming coats with primer of approved brand and manufacture having low VOC Volatile Organic Compound content With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall

1429.45

157

225267.0255

... More
cmy34 - Wall painting with premium acrylic emulsion paint of interior grade having VOC Volatile Organic Compound content less than 50 grams pre litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour Two coats as per specifications and as per directions of Engineer in charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall

1429.45

113

161956.685

... More
cmy35 - Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied at 1.67 ltr pre 10 m2 over and including priming coat of exterior primer applied at 2.20 kg per10 m2 with paint of approved quality to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge and with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall Entrance Arch

944.65

179

169300.173

... More
cmy36 - Supplying and fixing rolling shutters of approved make, made of required size M S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 part 1 and M S top cover of required thickness for rolling shutters 80x1.25 mm M S laths with 1 25 mm thick top cover including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor

30

2711

81359.7

... More
cmy37 - Providing and fixing double glazed hermetically sealed glazing in aluminium windows ventilators and partition etc with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket perforated aluminium spacers desiccants sealant Both primary and secondary sealant etc as per specifications drawings and direction of Engineer in charge complete including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor

43

4475

192440.05

... More
cmy38 - Providing and fixing pressed steel door frames conforming to IS 4351 manufactured from commercial mild steel sheet of 1.60 mm thickness including hinges jamb lock jamb bead and if required angle threshold of mild steel angle of section 50x25 mm or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means including M S pressed butt hinges 2.5 mm thick with mortar guards lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineer in charge Profile E Fixing with carbon steel galvanised dash fastener of required dia and size to be paid for separately including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Chargeand with all lead and lift and directions of the Engineer In charge of the work Ground Floor

1.3

2711

3525.587

... More
cmy39 - Providing and fixing glass panes with putty and glazing clips in steel doors windows clerestory windows all complete with 5.5 mm thick glass panes including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor

2.1

2711

5695.179

... More
cmy40 - Providing Sal wood frames of doors windows clerestory windows ventilators and other frames wrought framed or assembled including making plaster groves excluding cost of cement concrete and side clamps but including cost of materials labour usage charges complete as per specifications with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall

2.5

101779

254448.625

... More
cmy41 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials labour usage charges complete as per specifications excluding cost of fixtures with all lead and lift and directions of the Engineer In charge of the work Ground Floor

9.06

7667

69465.9192

... More
cmy42 - Providing and fixing flush door shutter made out of solid core block board type well seasoned chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part I 1991 from manufacturer complete as per spcification do 30 mm thick both side Teak.with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

17.19

4164

71584.1451

... More
cmy43 - Providing and fixing of 3track x 2 panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPV Thermo Plastic Vulcanized and lead free gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame The outer frame havinga overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 30mm x 48.5mm. Glazing bead for fixing of glass shall be of size 20mm x 24 mm Windows shall be provided with 5mm plain float glass standard hardware and single point locking system with touch lock Wall thickness of frame and sash shall be of 2mm-2.5mm Maximum possible size 2419mm x 2200mm The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

32

6936

221952.64

... More
cmy44 - Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm The cost is inclusive of all fixtures and separate charges for minorTandP s shall not be made with all lead and lift and directions of the Engineer In charge of the work Ground Floor

24

5890

141373.68

... More
cmy45 - Providing and fixing M S grills of required pattern in frames of windows etc with M S flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to steel windows by welding with all lead and lift and directions of the Engineer In charge of the work Ground Floor,Ritual Hall

1612.8

173

279078.912

... More
cmy46 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1 4 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc all complete as specified and as directed by the Engineer in Charge. Polished Granite stone slab Black Cat Eye River Pink or equivalentwith all lead and lift and directions of the Engineer In charge of the work Ground Floor

146.64

2937

430763.7984

... More
cmy47 - Providing and laying flamed finish Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1 4 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc all complete as specified and as directed by the Engineer in Charge Flamed finish granite stone slab Black Cat Eye River Pink or equivalent with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall

370.28

2539

940503.7944

... More
cmy48 - Providing and laying Vitrified tiles in different sizes thickness to be specified by manufacturer with water absorption less than 0.08prencentage and conforming to I S 15622 of approved make, in all colours and shade over 12 mm thick bed of cement mortar 1 3 1 cement 3 coarse sand jointing with grey cement slurry at 3.3 kg prem2 including grouting the joint with white cement and matching pigments etc complete Size of Tile 1000x1000 mm with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall

46.49

1919

89257.0808

... More
cmy49 - Providing skirting, dadooing rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1 3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials labour complete as per specifications with all lead and lift and directions of the Engineer In charge of the work Ground Floor Ritual Hall

353.13

1492

527035.9311

... More
cmy50 - Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1 2 4 1 cement 2 coarse sand 4 graded stone aggregate 20 mm nominal size and top layer 12 mm thick cement hardener consisting of mix 1 2 1 cement hardener mix 2 graded stone aggregate 6 mm nominal size by volume, hardening compound mixed at 2 L per 50 kg of cement or as per direction of Engineer incharge with all lead and lift and directions of the Engineer In charge of the work Ground Floor

58.59

824

48278.16

... More
cmy51 - Providing and laying Cement concrete pavement with 1 2 4 for commercial and residential building floors hardpaths footpaths using 1 cement 2 coarse sand 4 graded stone aggregate 20 mm nominal size including finishing complete as per Engineer incharge with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

2.33

6865

15997.7334

... More
cmy52 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS 15622 thickness to be specified by the manufacturer of approved make in all colours shades except burgundy bottle green black of any size as approved by Engineer in Charge in skirting risers of steps and dados over 12 mm thick bed of cement Mortar 1 3 1 cement 3 coarse sand and jointing with grey cement slurry at 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

42.4

1139

48301.232

... More
cmy53 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.with all lead and lift and directions of the Engineer-In-charge of the work.Ritual Hall

138.31

1139

157559.9858

... More
cmy54 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1 6 20 mm thick and joints finished with cement mortar 1 3 over existing cement concrete bed including cost of materials mortar labour curing complete as per specifications with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

7.85

5487

43079.544

... More
cmy55 - Providing edge moulding to 18mm thick Granite stone counters vanities etc including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer in charge Ritual Hall

20.3

337

6858.152

... More
cmy56 - Providing and fixing SFRC frame and cover conforming to IS 12592 part I 1988 and IS 12592 part II 1991 with latest amendment including cutting slabs to the required size for the opening and fixing the cover in C C 1 2 4 and C M 1 3 plastering 20 mm thick to all exposed faces curing for 10 days with all lead and lift with appurtenances. complete Heavy Duty with all lead and lift and directions of the Engineer In charge of the work Spetic Tank

1

2640

2640.92

... More
cmy57 - Providing 20mm square M S Footrest and fixing in manhole with 1 3 6 cement concrete block of 20x20x10 cms using 20mm an ddown size metal of size including cost of materials, labour charges curing complete as per specifications with all lead and lift and directions of the Engineer In charge of the work Spetic Tank

8

284

2274.24

... More
cmy58 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC Bathroom cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400 precentage and tensile strength greater than 2MPa as per ASTM D412 The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT dry film thickness of 1mm including prime coat of epoxy primer at 150 g per m2 and protection with 120gsm Geo textile over the waterproofing membrane The finished cost to include surface preparation making coving at Junction Bore Packing treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.with all lead and lift and directions of the Engineer In charge of the work Ground Floor

43.48

841

36588.8548

... More
cmy59 - Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied cold applied moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400 precentage and having solid content of above 90 precentage at 1.6kg per m2 in 2 coats to achieve final DFT dry film thickness of 1mm including prime coat of epoxy primer at 150 g pre m2 The cost is inclusive of surface preparation crack filling repair of loose mortar etc completely as per specification with all lead and lift and directions of the Engineer In charge of the work Spetic Tank

17.9

914

16372.056

... More
cmy60 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite grey granite in CM 1 3 1 cement 3 coarse sand proportion cut to required shape pattern with paper joints finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials mortar labour curing etc complete. with all lead and lift and directions of the Engineer In charge of the work Ground Floor

89.18

3459

308542.2886

... More
cmy61 - Providing and fixing 10 mm thick plaster of Paris gypsum anhydrous ceiling up to a height of 5 m above floor level over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame Flat surfaceswith all lead and lift and directions of the Engineer In charge of the work Ground Floor

239.3

1312

314014.246

... More
cmy62 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections trusses and framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete including cost of materials labour usage charges of machinery complete as Charge with all lead and lift and directions of the Engineer In charge of the work Ground Floor

21581.86

116

2511912.6854

... More
cmy63 - Providing and fixing Steel work in built up tubular round square or rectangular hollow tubes etc trusses etc including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc complete Hot finished seamless type tubes including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

12086.8

151

1830062.388

... More
cmy64 - Providing and fixing corrugated G S sheet roofing including vertical curved surface fixed with polymer coated J or L hooks bolts and nuts 8 mm diameter with bitumen and G I limpet washers or with G I limpet washers filled with white lead including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings up to any pitch in horizontal vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g pre m² with all lead and lift and directions of the Engineer In charge of the work Ground Floor

620.22

905

561528.5814

... More
cmy65 - Fabricating ,providing and erecting in position of MS Hot Dip Galvanized Gate using 72X72X4.8mm sq GI pipe frame with pipe bending in heavy duty hydrautic press with sand packing and hot bending to form doublearch as per drawing including providing hot dip galvanised forged ornmental design in between sq.rods and heads at top,middle and bottom Intermediate supports of 75X12mm and 50X6mm arch bent to hot dip galvanised flats the work is inclusive of thoughing GI flat GI sq rods placing welding all the joints including grinding finishing metal patty painting two coats enamel painting The rate is inclusive of all materials like GI sq. pipeGI sq.rods GI forged designs etc heavy duty hinges are made out of 75mm soild sq block assembled with 20mm sia bearing in three places for each dkop Heavy duty locking arrangements at tow places including cost of labour painting erecting charges using hoist pullry cranes with all lead and lift,loading transportation unloading scaffolfing charges and all other incidental charges for successful completion of the work as per directions of the Engineer in charge of the workwith all lead and lift and directions of the Engineer In charge of the work Ground Floor

6

12475

74850

... More
cmy66 - Providing and placing on terrace at all floor levels polyethylene water storage tank IS 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank with all lead and lift and directions of the Engineer In charge of the work Ground Floor

5000

9

46350

... More
cmy67 - Providing and fixing of Door locking arrangements with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

16

348

5568

... More
cmy68 - Providing and fixing of Handles powder coated 150mm with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

48

60

2880

... More
cmy69 - Providing and fixing of Hinges 5 inch heavy duty.with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

48

38

1824

... More
cmy70 - Providing and fixing of Hold fasts M S with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

64

50

3200

... More
cmy71 - Providing and fixing of Tower bolt 300mm long with all lead and lift and directions of the Engineer In charge of the work Ritual Hall

32

101

3254.08

... More
cmy72 - Providing and fixing chorinated poly vinyl Chloride CPVC pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement, trenching refilling and testing of joints complete external work 25mm nominal OD pipes with all lead and lift and directions of the Engineer In charge of the work Ground Floor

250

327

81885

... More
cmy73 - Providing and fixing C P brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g Ground Floor

100

871

87138

... More
cmy74 - Providing and fixing Brass full way valve gate with C I wheel of approved quality screwed end 32.mm Ground Floor

2

615

1231.88

... More
cmy75 - Providing and fixing in position below given nominal bore gun metal non return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments specification Ground Floor

50

988

49440

... More
cmy76 - Executive Benchs Made out Of sadarahally Grey stone with hand supporters with 3 linesfinishing witharch Design with 100mm slab height 90 X Length 150 Width 45 cms with all lead and lift and directions of the Engineer In charge of the work Ground Floor

20

18200

364000

... More
cmy77 - PHE WORKS Providing and fixing white vitreous china pedestal type water closet European type W C pan with seat and lid 10 litre low level white P V C flushing cistern including flush pipe with manually controlled device handle lever conforming to IS 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required W C pan with ISI marked white solid plastic seat and lid

6

4983

29898.84

... More
cmy78 - Providing and fixing wash basin with C I brackets 15 mm C P brass pillar taps 32 mm C P brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C P brass pillar taps

2

3174

6348.92

... More
cmy79 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C P brass spreaders with brass unions and G I clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required One urinal basin with 5 litre white P V C automatic flushing cistern

5

4587

22938.1

... More
cmy80 - Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C P brass screws and washers complete

2

1256

2513.2

... More
cmy81 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm width 78 mm and effective height of 88 mm weighing not less than 190 g

3

510

1532.64

... More
cmy82 - Providing and fixing PTMT angle stop cock 15 mm nominal bore weighing not less than 85 g

20

170

3419.6

... More
cmy83 - Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer in charge

15

834

12514.5

... More
cmy84 - Providing and fixing PTMT push cock of approved quality and colour 15 mm nominal bore 98 mm long weighing not less than 75 gms

3

131

395.52

... More
cmy85 - Providing and fixing in position brass stop cock of approved quality of as per dia nominal bore including cost of all materials,labour and HOM of equipments with all leads complete as per specifications 15mm Nominal Bore

5

307

1539.85

... More
cmy86 - Providing and fixing in position brass stop cock of approved quality of as per dia nominal bore including cost of all materials labour and HOM of equipments with all leads complete as per specifications 20mm nominal bore

5

314

1570.75

... More
cmy87 - Providing and fixing in position brass bib cock of approved quality of as per dia nominal bore including cost of all materials labour and HOM of equipments with all leads complete as per specifications

5

314

1570.75

... More
cmy88 - Providing and fixing PTMT soap Dish Holder having length of 138mm breadth 102mm height of 75mm with concealed fitting arrangements weighing not less than 106 g

10

103

1030

... More
cmy89 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished of size 75x50 cm deep and 1 8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1 2 4 1 cement 2 coarse sand 4 graded stone aggregate 6 mm nominal size as per direction of Engineer in charge and finished smooth

5.25

2872

15081.5175

... More
cmy90 - Providing and fixing bright finished brass hard drawn hooks and eyes 300mm

5

86

432.6

... More
cmy91 - WATER SUPPLY WORKS Providing and fixing Chorinated Poly Venyl CPVC pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete External work and Burried 25mm dia

50

304

15244

... More
cmy92 - Providing and fixing Chorinated Poly Venyl CPVC)pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete External work and Burried 32mm dia

55

383

21073.8

... More
cmy93 - Providing and fixing Chorinated Poly Venyl CPVC pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete External work and Burried 40mm dia

60

491

29478.6

... More
cmy94 - Providing and fixing Chorinated Poly Venyl CPVC pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamp at 1 mtr spacing This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete Concealed work including cutting chasing and good the walls etc 15mm dia

20

318

6365.4

... More
cmy95 - Providing and fixing Chorinated Poly Venyl CPVC pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamp at 1mtr spacing This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete Concealed work including cutting chasing and good the walls etc 20mm dia

30

390

11711.1

... More
cmy96 - Providing and fixing Chorinated Poly Venyl CPVC pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamp at 1 mtr spacing This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete Concealed work including cutting chasing and good the walls etc 25mm dia

40

491

19652.4

... More
cmy97 - Providing and fixing water meter with stop cock jam nut socket in G I pipe line including cutting and threading the pipe and making long screws including cost of all materials, labour HOM of equipments and testing complete as per specifications

1

1359

1359.6

... More
cmy98 - Providing and fixing ball valve brass of approved quality High or low pressure with plastic floats complete

5

341

1709.8

... More
cmy99 - Providing and fixing Brass full way valve gate with C I wheel of approved quality screwed end 32mm dia

5

615

3079.7

... More
cmy100 - Providing and fixing Brass full way valve gate with C I wheel of approved quality screwed end 40mm dia

5

723

3615.3

... More
cmy101 - Providing and fixing in position below given nominal bore gun metal non return valve horizontal type of approved make including cost of all materials labour and HOM of equipments specification

5

1261

6308.75

... More
cmy102 - DRAINAGE WORKS Supplying PVC ringtite pipes conforming to IS 4985 2000 with latest amendments and conveying to worksite rolling and lowering into trenches laying true to line and level and perfect linking at joints testing and commissioning including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc for:BWSSB SR 2021 2022 75 mm dia

50

216

10815

... More
cmy103 - Supplying PVC ringtite pipes conforming to IS 4985 2000 with latest amendments and conveying to worksite rolling and lowering into trenches laying true to line and level and perfect linking at joints testing and commissioning including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc 110mm dia

60

405

24349.2

... More
cmy104 - Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet Sand Cast Iron Sand S as per IS 1729a

10

1179

11793.5

... More
cmy105 - Providing and fixing PTMT grating of approved quality and colour

20

45

906.4

... More
cmy106 - Cleaning and desilting of gully trap chamber including removal of rubbish mixed with earth etc and disposal of same, all as per the direction of Engineer in charge

20

80

1606.8

... More
cmy107 - Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1 6 bed concrete 150mm thick with 1 3 6 plastering 12 mm thick with cement mortar 1 4 CC 1 2 4 coping 75mm thk for fixing CI cover and frame etc excluding the cost of CI frame and cover

2

4505

9010.44

... More
cmy108 - Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland Pozzolana cement conical in shape at top with CC 1 3 6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber Construct Brick masonry in CM 1 4 340 mm thick with wirecut bricks of approved quality plaster inside and out side with CM 1 3 12mm thick except for the conical surface outside where the plaster thickness shall be 20mm Slope inside to be 1 6 in the concrete towards central drain and finished smooth Fixing of pipes in CC 1 2 4 with graded metal of 20mm and down size Supplying and fixing SFRC Machinehole frame and cover Heavy Duty conforming to IS 12592 with latest amendment in CC 1 2 4 Supplying and fixing footsteps made of 12mm dia steel bars Fe-500 with 3mm thick plastic encapsulation I S 10910 The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall The whole works include watering curing barricading danger lighting pouring tar over MH frame and cover, cost of tar shoring strutting dewatering engraving Machinehole number with flow direction on the inner conical surface etc as per the drawing etc as per technical specifications and for the following diameters and depth etc for 1.2mm diaCirc B M.H Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. 1.0 M depth and SFRC cover and frame

1

28763

28763.78

... More
cmy109 - MAIN FURNACE : Supply, Installation, Testing, and Commissioning of Main Furnace: Supply of Fabricated main frame for housing refractory bricks and other equipment, Furnace the main door, Furnace supporting frame, Main door lifting mechanism by hydraulic system, Hand pump is provided to operate manually, Ash removing door and Ashtray, Ash removing tools, Other accessories, front SS sheet covering, top, side, and back covered with MS sheet.Materials used for Main Furnace as per fabrication drawing MS angle size 50 x 50x5mm, MS sheet-2mm, 5mm, MS Flats-100x5mm, 100x16 mm, 50 x 10 mm,40x5 mmS S sheet 1.5 mm sheet and Sq rod-20x20mm.M S Pipe 75x25 mm, Bolts and Nuts of various sizes, Hinges self threading screws Shaft dia 50 Sprockets chain Gearbox motor and other accessories to complete the furnace frame The Furnaces overall dimensions will be 2200 W X 2540 H X 3750 L

1

820650

820650

... More
cmy110 - REFACTORY MATERIALS Supply Installation Testing and Commissioning of refractory items such as ceramic fiber blankets insulation bricks Hot Zone bricks IS8 Cold Zone bricks IS6 body resting bricks arch supporting bricks arch bricks For the construction of refractory items binding agents such as Fire clay Ref cast super Castables etc to build the furnace body burning chamber with all side refractory walls and Door with a ceramic blanket. Bottom of the chamber, 9 Body resting bricks Heat resisting bricks shaped suitably smoke trenches are provided to let out the smoke below the chamber it passes through apx 13 mtr before going out of the furnace To provide oxygen to the furnace chamber to improve burning passage to the main chamber and smoke trenches from a fresh air blower were provided The main body burning chamber size is 2850mm L x 1150mm H x 1000mm W suitable for charging one body at a time Refractory Materials used for constructing the furnace chamberRefractory bricks of Standard IS8, IS6 of which withstanding temperatures up to 1200 degreeRefractory bricks size IS8 and IS6 230 x 115 x 75 mm Slabs 600 x 300 x 150 mm Arch bricks 230 x 115 x 75 / 55 mm Insulation bricks 230 x 115 x 75 mm c Body resting bricks (Heat resisting bricks) size 600 x 300x150 mm Refractory binding agent Fire clay Fire crate supper mortarCeramic blanket size: 600 x 25 mm Gr 64,128 kg pre m3Any other other accessories are required to complete the furnace chamber construction

1

720650

720650

... More
cmy111 - ELECTRICAL HEATING COOL: Supply, Installation, Testing, and Commissioning of vertical Heating coil Power of 42 KW. Heating coils are made out of 8 swg Kanthal APM wire / Nichrome 80/20 wire of 8 Gauge with terminal rods. Vertically mounted 12 No’s coils of each of 3.5 KW, Housed in S S pipe (Stainless Steel pipe) of 310 grade with insulation made out of ceramic material with pipe suitable mounting arrangement. Any other accessories required to complete the system.

1

966000

966000

... More
cmy112 - BODY CHARGING TROLLEY: Supply, Installation, Testing, and Commissioning of Body Charging Trolley Supply of fabricated Hydraulically operated Body Charging Trolley with power pack and connecting pipelines and control desk to operate with all accessories. The total operation time is is minimum to place the body inside the chamber.The body charging trolley is made out of a rigid framework, a hydraulically operated Lifting and Pushing system with all necessary equipment required. The above trolley is mounted on a solid suitable moving system. Fully operated from the Control desk Any other accessories required to complete the system.

1

750000

750000

... More
cmy113 - ELECTRICAL REMOTE CONTROL PANEL Supply Installation Testing and Commissioning of Electric Remote Control panel The control panel is built with the following components housed in Panel made out of M S sheet duly powder coated, with floor mounting arrangements.Main incoming switch MCCB 200A Copper bus bar mounted on insulators to terminate distribute supply to motors Main power coils Measuring instruments such as Voltmeter Ammeter Energy meter Temperature Controller through CTs Each motor circuit will have MCB contactors operating push buttons indication lamps ON OFF switches for all circuits All electrical components are connected with wiring upto outgoing terminal Any other accessories required to complete the remote control panel The incoming power supply 3 phase with neutral to be connected at MCCB installed in our control panel by user

1

420000

420000

... More
cmy114 - CONTROL AND POWER CABLES Supply Laying Testing and Commissioning of Control and Power CablesSupply of power cables, bus bar laying supporting tray conduit pipes from the control panel to various equipments, heating coils motors water pump Exhaust Blower Fresh Air Blower Power Pack Thermocouple Aviation Lamp will be laid and connected on either side with MCB to Switch off the equipment within hand reach distance of items installed with suitable capacities as per electrical inspectorate guidelines and standard Earthing of all equipment connected to furnace installation will be connected as per electrical inspectorate guidelines and standard We will connect all earthing connections to the earthing pit provided by the user one pit for the chimney and the other for the furnace and other equipment Any other accessories required to complete the system.

1

321000

321000

... More
cmy115 - WATER PUMP Supply Installation Testing and Commissioning of Water pump Supply of water pump for scrubber unit 1 Hp motor 3 Phase 415V for circulating the water in wet venture scrubber unit and necessary pipelines inlet outlet openings of suitable sizes required to circulate the water maintenance easy fittings water tank level maintaining ball valve water tank drain out system to soak pit Any other accessories required to complete the system Soak pit should be provided by the user

1

82785

82785

... More
cmy116 - FRESH AIR BLOWER Supply Installation, Testing and Commissioning of Fresh air blower Made out of M S Sheet direct driven motor of 1 Hp 3 Phase 415V of suitable capacities mounted on a M S rigid angle frame, connected by means of M S pipeline with butterfly valves to blow the fresh air inside the furnace chamber Any other accessories required to complete the system

1

83630

83630

... More
cmy117 - WET VENTURI SCRUBBER UNIT Supply Installation Testing and Commissioning of Scrubber unit Wet scrubber unit with venturi arrangements made out of S S 304G sheets. In unit 1 smoke will completely come in contact with water and pass through the neck to Unit 2 where water is separated and drained out to the water tank further filtration of other particles left out with smoke will pass through the louver arrangement The above unit is mounted on a M S rigid supporting structure with a suitable height The water storage tank for the above unit is made out of S S 304G with suitable size Apx 2150 L x1050 W x730 H mm is placed below the scrubber unit with a proper support to have clearance from the groundAll inlet and outlet connections, square duct made out of S S 304G with required bends and connected with flange joints from the furnace to scrubber unit inlet and scrubber unit outlet to Exhaust Blower inlet and Exhaust Blower outlet to Chimney with suitable sizes Any other accessories required to support pipeline etc to complete the system

1

628500

628500

... More
cmy118 - ONLINE EXHAUST BLOWER Supply Installation Testing and Commissioning of online Exhaust BlowerFabricated with an S S 304G sheet the impeller driving shaft is also made out of S S with bearing support mounted on a suitable rigid supporting frame with suction and delivery pipelines The blower is driven by a belt drive with 5Hp 3 Phase 415V 50 Hz motor with a protection guard

1

384000

384000

... More
cmy119 - Erection charges for Erection, testing commissioning handing over the cremation furnace a Fixing of Frame Main Door Counterweight Mechanical and Electrical operating door system b Refractory lining work Fixing of Fresh air blower Construction of Trench Fabrication of Scrubber lining work Fixing of scrubber unit Erection of self-supporting chimney Erection and fixing of related Panels and other Systems Equipment.

1

450000

450000

... More
cmy120 - TRANSPORTATION CHARGES Packing forwarding Loading and Unloading charges from our factory in Bangalore to the crematorium site

1

220000

220000

... More
cmy121 - Supply Installation Testing and Commissioning ofSelf supporting chimneyThe chimney is made out of M S Plates, angles, flats, grouting bolts and gusset plates ladder platform with a protection cage up to the platform Climbing steps from the platform to the top of the chimney The chimney bottom cone dia 700 dia 300 up to 12 mtr and traight pipe of dia 300 mm up to 12 mtr 30 mtrThe bottom cone is made out of 8 mm plate up to 12 mtr in heightStraight pipe made of 5mm thick Base plate made out of25mm M S Plate of 1200x1200 mmRing flange made out of 16 mm thick M S PlateVertical ribs with rigid supportChimney connecting flanges 10mm thick 07 nos with gusset platesConical segment flange 02 nosInspection door of suitable size Foundation bolts of dia 40 mm x 2000mm 10 nosdia 40 mm x 1500mm 04 nosWith washers nuts and checknutsHood is made out of 3 mm plate of suitable size withsupports ladder made out of 25x25x4mm angle with stepsPlatform and platform protection railing made out of 50 x 50 x 5 mm Angle pipe flat Safety measures like aviation lamps lighting arrester and earthing strips etc

1

1105500

1105500

... More
cmy122 - ELECTRICAL WORKS Open Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends junction boxes adhesive paste etc and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick

300

83

25029

... More
cmy123 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends metal PVC Junction boxes adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19 20 mm dia 2 mm thick

650

67

44187

... More
cmy124 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends metal PVC Junction boxes adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick

450

80

36153

... More
cmy125 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxe adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thick

100

106

10609

... More
cmy126 - Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends metal junction boxes adhesive paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19 20 mm dia 2 mm thick

450

70

31518

... More
cmy127 - Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends metal junction boxes adhesive paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thick

250

81

20342.5

... More
cmy128 - Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends metal junction boxes adhesive paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32 mm dia 2.5 mm thick

70

101

7137.9

... More
cmy129 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends junction box elbows, screws at an interval of 300 mm etc as required. 25 mm

20

36

721

... More
cmy130 - Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm

25

22

566.5

... More
cmy131 - Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 32 mm

15

29

448.05

... More
cmy132 - Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable conduit entry as required with one coat of primer of approved make etc 200 x 90 x 65 mm

5

184

921.85

... More
cmy133 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 Phase and Neutral and 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments without control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet Short point upto 3m from tapping point to out let via switch box

45

277

12468.15

... More
cmy134 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 Phase and Neutral and 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet Medium point above 3m upto 6m from tapping point to out let via switch box

75

390

29277.75

... More
cmy135 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 Phase and Neutral and 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments without control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet Long point above 6m upto 10m from tapping point to out let via switch box

55

571

31440.75

... More
cmy136 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 Phase and Neutral and 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments without control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet Two outlet in a row, above 3m upto 6m from tapping point to out let via switches

5

697

3486.55

... More
cmy137 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 Phase and Neutral and 1x1.0 mm2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS 694 and latest amendments without control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet Three outlet in a row above 6m upto 10m from tapping point to out let via switches box

4

1018

4074.68

... More
cmy138 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments 1 mm2

1500

19

29355

... More
cmy139 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 1.5 mm2

850

26

22763

... More
cmy140 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 2.5 mm2

1200

43

51912

... More
cmy141 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 4 mm2

750

64

48667.5

... More
cmy142 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 6 mm2

155

94

14687.8

... More
cmy143 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments 10 mm2

50

172

8600.5

... More
cmy144 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick Stone C C wall 1 2 Way

13

142

1847.82

... More
cmy145 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick Stone C C wall 3 Way

10

163

1637.7

... More
cmy146 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way

6

182

1093.86

... More
cmy147 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick Stone C C wall 6 Way

8

226

1812.8

... More
cmy148 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick Stone C C wall 8 Way

3

268

806.49

... More
cmy149 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way

5

328

1642.85

... More
cmy150 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick Stone C C wall 16 Way

2

373

747.78

... More
cmy151 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 Way

2

417

834.3

... More
cmy152 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal/PVC box 1 2 Module

13

141

1834.43

... More
cmy153 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal/PVC box 3 Module

10

165

1658.3

... More
cmy154 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal/PVC box 4 Module

6

180

1081.5

... More
cmy155 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc complete on the existing metal/PVC box 6 Module

8

241

1928.16

... More
cmy156 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal PVC box 8 Module

3

292

877.56

... More
cmy157 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal PVC box 1012 Module

5

354

1771.6

... More
cmy158 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal PVC box 16 Module

2

408

817.82

... More
cmy159 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing metal PVC box 18 Module

2

470

941.42

... More
cmy160 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch

175

105

18385.5

... More
cmy161 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket

25

176

4403.25

... More
cmy162 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two Module

24

367

8825.04

... More
cmy163 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch

3

185

556.2

... More
cmy164 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Bell Push

1

182

182.31

... More
cmy165 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch

2

335

671.56

... More
cmy166 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6 16A Universal Socket

5

243

1215.4

... More
cmy167 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV Telephone Socket

1

160

160.68

... More
cmy168 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ45 I O Outlet Cat 6

5

347

1735.55

... More
cmy169 - Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws 80 90 mm

175

15

2703.75

... More
cmy170 - Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws 110 mm

24

21

519.12

... More
cmy171 - Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote Ding Dong Bell

1

253

253.38

... More
cmy172 - Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 precentage lumen maintenance with CRI less than 80 Power Input 220-240V at 50 pre 60Hz and Power factor less than 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 2 feer 9 by 10 W

2

567

1135.06

... More
cmy173 - Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70prtecentage lumen maintenance with CRI less than 80 Power Input 220 240V at 50 pre 60Hz and Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 by 4feet 20 by 22 W

30

710

21321

... More
cmy174 - Supply of round square recess surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring with Life of 25000 burning hours and 70precentage lumen maintenance with CRI less than 80 Power Input 220 by 240V at 50pre 60Hz and Power factor less than 0.9 along with CE approved 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15 18W

5

1363

6818.6

... More
cmy175 - Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 23 pre 0.0076inches twin twisted PVC insulated wires required Nos of round blocks and clA On wall ceiling Rafter Girders

185

125

23247.1

... More
cmy176 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE star rated and IS 374 79 and also comply with IS 1709 1984 with latest amendment Rated voltage 220 V 50 Hz Rated power input 48 W 10 precentage Rated current As per IS 374 79 Rated power factor 0.9 lagging min Rated speed 350 10 precentage RPM Rated air delivery 210 10precentage Cubic Meter Minimum Rated service value 4.2 CMM pre W Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet Class B motor insulation Bearing Two ball bearings Top 6202 Bottom 6201 as per IS specification Motor winding Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms 2M Ohms Leakage current Should not exceed 210 Micro Amp Power input Wand current Air Delivery and Fan Speed as per IS 374 1979 with latest amendment 2 year manufacturerWarranty 48inches Sweep BEE Star Rated 1200 mm

24

2757

66175.44

... More
cmy177 - Supplying wall mounting fan suitable to operate at single phase 230v AC supply 300 mm Sweep

2

2566

5133.52

... More
cmy178 - Fixing a ceiling wall mounting fan of all capacities and all types, with necessary clA and S hook made out of 15mm dia MS rod with 5 A ceiling rose of approved quality with necessary length of 23per 0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wooden board and wired

10

176

1761.3

... More
cmy179 - Fixing a ceiling wall mounting fan of all capacities and all types with necessary clamps and S hook made out of 15mm dia MS rod, with 5 A ceiling rose of approved quality with necessary length of 23 pre 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired

16

324

5191.2

... More
cmy180 - Extra length of GI pipe of class B 19mm dia for down rod

42

202

8522.22

... More
cmy181 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz AC Supply complete. 12 inch Sweep 300 mm

6

3058

18348.42

... More
cmy182 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A ceiling rose with sufficient length of 23 pre 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame

6

728

4369.26

... More
cmy183 - Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRI less than 70 precentage efficacy less than 80 lumen per W life less than 25000 burning hours and Compliance to IS 10322 per IEC 60598 LM 79 and LM 80 The LED are driven by HF electronic driver integrated in the system with PF less than 0.95 power loss should greater than 5 precentage of lamp Wage short circuit and open circuit protection to be integrated in the circuit THD less than 20 precentage Life as per LM 79 The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by ABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 9W 6500K

20

158

3172.4

... More
cmy184 - Supplying and Fixing of 70 to 150 W lamp holder 2 Pin

65

64

4217.85

... More
cmy185 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate or clear glass material delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 precentage CCT less than 5500K IP 66 optical and electrical compartment and impact resistance of complete luminaire less than IK08 Power Factor less than 0.9 with mains Surge Protection Min 5KV along with Over voltage Overload short circuit miss wiring protection Compatible for pole mauling with outer dia of 40mm to 50mm Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 pre 60Hz application Compliance to IS 10322pre IEC 60598 LM 79 and LM 80 Adherence with RoHS UL approved MCPCB Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools LED Light fixture with W System Power consumption LED Efficiency less than 1301m per w nominal CRI less than 75 Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008 Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source LED Floodlight 100W

16

9770

156329.28

... More
cmy186 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonateper clear glass material delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 precentage CCT less than 5500K IP 66 optical and electrical compartment and impact resistance of complete luminaire less than IK08 Power Factor and 0.9 with mains Surge Protection Min 5KV along with Over voltage Overload short circuit miss wiring protection Compatible for pole mauling with outer dia of 40mm to 50mm Universal Voltage driver to operate wide voltage range from 100 V to 270V 50pre 60Hz application Compliance to IS 10322 IEC 60598 LM 79 and LM 80 Adherence with RoHS UL approved MCPCB Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools LED Light fixture with W System Power consumption. LED Efficiency less than 1301m pre w nominal CRI less than 75 Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source LED Floodlight 70W

22

6971

153362.88

... More
cmy187 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 precentage maximum light intensity should be between 60 degrees to 70 degrees CCT less than 5500K IP66 optical and electrical compartment and impact resistance of complete luminaire less than IK08 Power Factor less than 0.9 with mains Surge Protection Min 5KV along with Over voltage Overload short circuit miss wiring protection Compatible for pole mounting with outer dia of 40mm to 50mm Universal Voltage driver to operate wide voltage range from 100V to 270V 50 pre 60Hz application Compliance to IS 10322 IEC 60598 LM 79 and LM 80 Adherence with RoHS UL approved MCPCB Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption LED Efficiency less than1301m pre w nominal CRI less than75 Luminaire manufacturer should have in-house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008 Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source LED Streetlight 70W

16

6171

98748.16

... More
cmy188 - Supplying and Fixing of mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole wall using suitable clamps, bolts and nuts and wiring using suitable capacity wires Using 25mm dia G I Pipe

12

1007

12088.08

... More
cmy189 - Fixing halogen metal halide SVL IL LED floodlight fitting over existing pole wall ceiling including clamps bolts nuts and wiring using suitable capacity wires

54

166

9010.44

... More
cmy190 - Fabricating supplying and erection of ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft IS 2062 for base plate with door opening arrangements, including suitable boards Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m pre sec for m Pole in single section and single joint welded as per IS 9595 IS10178AWS having dimensions bottom mm top mm with 3 mm thick suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM A123 and 153 etc excluding foundation as per drawing appended 6 m - Top 75 mm and Bottom 135 mm dia

4

13081

52324

... More
cmy191 - Supplying, and fixing of Hot dip Galvanized M S Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts nuts etc complete Single Arm Bracket with 1500 mm Standard 40 and 50 mm dia

4

2163

8652

... More
cmy192 - Supply and Installation Fixing Provision of Pole box with HRC Fuse MCB provision and suitable connector terminal for 3 Ph 1 Ph connections with Loop In and Loop Out terminals for 10 mm2 per 25 mm2 3.5 C AI Ar Cu Ar Cable and branch out 2.5 mm2 2 core AI Cu PVC Insulated cable enclosed in a Thermoplastic Polystyrene enclosure, which should be shock proof safe IP65 Weather Proof rust proof dust proof water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic polyamide glands and/or grommets. 200 mm x 200 mm x 98 mm

4

2369

9476

... More
cmy193 - Automatic Switch for Street Light

1

2372

2372.09

... More
cmy194 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 2 Pair

25

21

540.75

... More
cmy195 - Supplying and fixing of MDF krone junction box with KRONE Module Telephone cable termination 10 Pair

1

355

355.35

... More
cmy196 - Supplying installing testing and commissioning of Diesel Generator set with following specifications Power rating as per standard reference condition as per BS 5514 ISO 3046 ISO 8528 and IS 1002 ISO 3046 Generator set specifications 62.5KVA pre 50kw

1

660313

660313.13

... More
cmy197 - Supply, Erection, testing and commissioning of AMF panel suitable for kVA DG set The panel is of cubical type base floor mounting control panel with hinged doors undrilled bottom gland plate aluminium Bus Bar with the accommodation for A 4 pole contactor for alternator with thermal O or L relay A 4 pole contactor for mains HRC fuse for short circuit protection Microprocessor based AMF module with supply failure timer Restoration timer 3 impulse automatic engine start or stop logic Mains or generator voltage capacity bypass switch and frequency sensing, PCC 1301controller with water temperature Lube oil pressure engine speed Voltage ampere Frequency kVA Running hour count No of starts Fault indication over under speed Fails to start Low oil pleasure High engine temperature Under over voltage over current Earth fault relay with indications for Mains on Load on Mains Battery charger on Push buttons AMF module by pass Mode Battery charger unit with inbuilt Auto/Manual and Flat Boost facility The complete set shall have sufficient safety and adhere to NEC NBC 2016 IEC CPWD specifications PCB norms and KSGEI Acts and Rules 62.5 KVA

1

80101

80101.14

... More
cmy198 - Supplying fixing and wiring earth electrode for grounding of lifts transformers, DG sets etc using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrodeThe funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all round with alternate layers of salt and charcoal from the bottom of the CC chamber The connection from the electrode is to be established through GI strip using GI bolts and nuts

24

4383

105208.32

... More
cmy199 - GI Copper strips for grounding connections using necessary fixing materials as required GI Copper strips 25 x 6 mm GI strip

70

131

9228.8

... More
cmy200 - GI Copper strips for grounding connections using necessary fixing materials as required GI Copper strips 25 x 6 mm Copper strip

25

1133

28325

... More
cmy201 - GI/Copper strips for grounding connections, using necessary fixing materials as required GI/Copper strips 600 x 600 x 3 mm Copper plate

4

7643

30574.52

... More
cmy202 - RCC Pole 9 Mtr Long 145 Kg WL Dwg No BESCOM GM Qs and S 02 Dtd 24 nov 2018 as per IS785

25

7288

182207

... More
cmy203 - PSCC Pole 8 Mtr Long 140 Kg WL Dwg No BESCOM GM Qs and S 17 Dtd 24 nov 2018 as per REC Standards

4

2754

11016.88

... More
cmy204 - 11 kV Special 3 Pin Cross Arm GI

28

1185

33194.84

... More
cmy205 - HT ST Support 50 by 8 mm Flat GI

28

124

3489.64

... More
cmy206 - Spiral Earth Electrode

25

246

6154.25

... More
cmy207 - Anticlimbing Device GI Barbed wire 12 Mtr preKg

10

91

916.7

... More
cmy208 - Guarding for Road crossing Telephone Line Crossing between HT and LT Line Crossing

20

95

1915.8

... More
cmy209 - LT 4 Pin Cross Arm GI

22

390

8588.14

... More
cmy210 - No 8 Strain Insulator

96

27

2669.76

... More
cmy211 - RCC Pole Clamp GI

28

112

3143.56

... More
cmy212 - Guy Clamp GI

5

118

592.25

... More
cmy213 - 11 kV GI Pin for 11 kV Ceramic Shell Insulator

75

67

5098.5

... More
cmy214 - DISC Insulator 45 kN Porcelain

12

525

6303.6

... More
cmy215 - Rabbit ACSR 6 pre 3.35 mm Al pluse 1 per 3.35 mm St Std Wt 214 Kg pre KM

1

47621

47621.02

... More
cmy216 - 7 to 10 SWG Guy Wire 7 pre 3.251 mm Dia Std Wt 680 Kg pre KM

0.01

79542

795.4278

... More
cmy217 - PG Clamp Rabbit to Rabbit

16

105

1680.96

... More
cmy218 - 9 kV 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR Dwg No BESCOM GM QS and S 26 Dtd 24 oct 2007

3

947

2842.8

... More
cmy219 - 11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QSandS/21 Dtd 24.11.2018)

1

1101

1101.07

... More
cmy220 - For 100 to 300 kVA 4 to 5 Star Rated Transformer on RCC Pole 9 Mtr Long 145 Kg WL GI

1

31614

31614.82

... More
cmy221 - Three H Frame with Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA UG Cable GI

1

48132

48132.93

... More
cmy222 - 11 kV 200 Amps Single Break GOS Dwg No BESCOM GM QS and S 23 Dtd 24 nov 2018

1

9733

9733.5

... More
cmy223 - 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification

1

6051

6051.25

... More
cmy224 - Transparent Alkathine tube 19 mm dia 2 mm thick in coils of 30 Mtr

1

532

532.51

... More
cmy225 - Caution Danger Board

12

154

1854

... More
cmy226 - Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel RCC PSCC supports as per approved Drawing Hard Soil

25

1165

29149

... More
cmy227 - Digging of Pit for GUY SET Hard Soil

5

647

3239.35

... More
cmy228 - Erection of RCC PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth

25

1146

28659.75

... More
cmy229 - Providing Spiral Earth Electrode type earthing without charcoal salt etc

25

95

2394.75

... More
cmy230 - For Three H Frame without Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA UG Cable excluding erection of Pole

1

2947

2947.86

... More
cmy231 - Fixing of 4 Pin cross arm with Insulator and Braces fixing

22

164

3625.6

... More
cmy232 - Fixing of HT and LT Single Top Support

25

115

2884

... More
cmy233 - Fixing of GUY Set with break insulator making use of 7 to 3 15 mm 7 per 10 SWG galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing Excluding excavation of PIT

10

273

2739.8

... More
cmy234 - Stringing of conductor Rabbit ACSR, binding of conductor on each insulator and dead ending on strain or disc strain insulator by means of clamps.

1

4491

4491.83

... More
cmy235 - Fixing DOLO Cutout Horn Gap Fuse including fixing of cross arm and wiring

1

244

244.11

... More
cmy236 - Fixing of GOS including wiring 11 kV Single Break 200 Amps

1

1137

1137.12

... More
cmy237 - Numbering and Scheduling of Pole

1

733

733.36

... More
cmy238 - Distribution Transformer 3 Phase 11kV per 433V Stacked CRGO Core with Oil as per IS 1180 Part 1 2014 B CABLE ENTRY TYP 250 kVA UG Cable excluding erection of Pole

1

458702

458702.26

... More
cmy239 - LT Distribution Box for 100 to 250 kVA DTC with MCCBs SMC

1

25160

25160.84

... More
cmy240 - 3 Phase CT PT operated alternating current Smart Meter of Accuracy Class 0.2s DLMS with GPRS Communication Module

1

30892

30892.79

... More
cmy241 - 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT and 3 PT With Transparent Cover TTB with 30x8 mm Copper Busbar Modem and 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated as per revised Specification Dwg No BESCOM GM QS and S Dtd 24 nov 2018

1

250776

250776.16

... More
cmy242 - Erection of 200 250 kVA Transformer

1

2346

2346.34

... More
cmy243 - Erection of HT metering Cubicle on Platform

1

1899

1899.32

... More
cmy244 - 11 kV 3 Core XPLE HTUG Cable with pressure extruded inner sheeth ROUND WIRE ARMOURED as per IS 7098 Part 2 Armouring wires dia and Resistivity as per IS 3975 95 Sqmm 54 GI Wires 2.5 mm Dia

0.1

916355

91635.598

... More
cmy245 - Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm

8

3856

30850.56

... More
cmy246 - Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm

2

4189

8378.02

... More
cmy247 - Laying of cable in Existing Trench GI pipen Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 Sqmm

0.1

63161

6316.166

... More
cmy248 - 1.1 kV XLPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 Part 1 or IS 7098 Part 1 Armouring strip thickness and resistivity as per IS 3975 185 Sqmm 3.5 Core 28 GI Strips 4 x 0.8 mm

0.3

711954

213586.362

... More
cmy249 - 1.1 kV X LPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 Part1 or I 7098 Par Armouring strip thickness and resistivity as per IS 3975 120 Sqmm 3.5 Core 28 GI Strips 4 x 0.8 mm

0.2

470595

94119.134

... More
cmy250 - 1.1 kV XLPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 Part 1 or IS 7098 Part 1 Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 4 Core 13 GI Strips 4 x 0.8 mm

0.18

185239

33343.0776

... More
cmy251 - 1.1 kV XLPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 Part 1 or IS 7098 Part 1 Armouring strip thickness and resistivity as per IS 3975 50 Sqmm 3.5 Core 16 GI Strips 4 x 0.8 mm

0.075

184342

13825.66425

... More
cmy252 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm

0.15

121544

18231.618

... More
cmy253 - Aluminium End Terminal Lug 10 sqmm

40

82

3280

... More
cmy254 - Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal Apprx Wt 11 Gm

76

27

2113.56

... More
cmy255 - Heavy Duty Copper Terminal Long Barrel 50 Sqmm Copper Terminal Apprx Wt 26 Gm

60

59

3584.4

... More
cmy256 - Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal Apprx Wt 58 Gm

12

132

1594.44

... More
cmy257 - Heavy Duty Copper Terminal Long Barrel 120 Sqmm Copper Terminal Apprx Wt 64 Gm

12

144

1730.4

... More
cmy258 - Heavy Duty Copper Terminal Long Barrel 185 Sqmm Copper Terminal Apprx Wt 158 Gm

36

282

10159.92

... More
cmy259 - Brass Cable Gland 25

4

81

325.48

... More
cmy260 - Brass Cable Gland 32

2

97

195.7

... More
cmy261 - Brass Cable Gland 40

2

152

304.88

... More
cmy262 - Route and Joint indicating slab with MS Anchor rod

10

136

1369.9

... More
cmy263 - Laying of cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm

0.33

21512

7099.1514

... More
cmy264 - Laying of cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm

0.08

32073

2565.8536

... More
cmy265 - Laying of cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff LT Cable 120 to 240 Sqmm

0.5

33246

16623.17

... More
cmy266 - Fabricating supplying and mounting MS box made out SWG suitable for floor wall mounting fully weather proof with provision for better heat dissipation provided with hinged front cover equipped with tamper proof locking arrangements with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc complete 14 SWG

250000

-

130000

... More
cmy267 - Supplying fixing and wiring 50 or 5 to 400 or 5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound

4

578

2315.44

... More
cmy268 - Supplying and fixing Electronic Trivector Meter ETV suitable for operation LT operation and CT operated meter in polycarbonate body in class0.5 accuracy as per IS 14697 and completely wired

1

4521

4521.7

... More
cmy269 - Supplying and fixing of Shunt trip suitable for MCCB CBCT

1

1754

1754.09

... More
cmy270 - Supplying fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based digital readout of percentage leakage current programmable delay auto manual reset facility suitable to mount on DIN rail flush mounting on panel board

1

9532

9532.65

... More
cmy271 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230 to 440VAC 50 Hz 12 to 24V D C

3

530

1591.35

... More
cmy272 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON or OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 32 A SP

22

427

9403.9

... More
cmy273 - Supplying of multi function digital meter with three line back light LCD type display for voltage Current frequency Power power factor kVA kWH kVAR suitable for 3 phase 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0 5s accuracy

1

9594

9594.45

... More
cmy274 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood panel board using necessary screws bolts nuts necessary phase separators handle and wiring complete Protection of Overload and Short circuitwith adjustable thermal magnetic release Micro processor release shall have Earth Fault as per IS IEC 60947 2 Icu 100precentage lcs In 4P MCCB, all Poles should have protection for Short Cicrcuit Over Load For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism FOUR Pole 400 A 36 kA

1

29062

29062.48

... More
cmy275 - Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts nuts and washers etc complete 400 A 4 x 50 x 10 mm Aluminium Strips

4

4578

18313.4

... More
cmy276 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts nuts necessary phase separators handle and wiring complete Protection of Overload and Short circuitwith adjustable thermal magnetic release Micro processor release shall have Earth Fault as per IS IEC 60947 2 Icu 100 precentage lcs In 4P MCCB all Poles should have protection for Short Cicrcuit Over Load For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism FOUR Pole 200 A 25kA

2

17820

35640.06

... More
cmy277 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood panel board using necessary screws bolts nuts necessary phase separators handle and wiring complete Protection of Overload and Short circuitwith adjustable thermal magnetic release Micro processor release shall have Earth Fault as per IS IEC 60947 2 Icu 100precentage lcs In 4P MCCB all Poles should have protection for Short Cicrcuit Over Load For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism FOUR Pole 100 A 25kA

2

8741

17483.22

... More
cmy278 - Rotary handle for MCCB

5

3860

19302.2

... More
cmy279 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON or OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50 to 63 A TPN

8

3180

25445.12

... More
cmy280 - Supplying of on load change over switches 4poles AC Aduty 415V 50Hz AC Supply With all accessories SM Enclosure Sheet Metal Execution 100 A

1

8790

8790.02

... More
cmy281 - Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts nuts and washers etc complete 100 A 4 x 30 x 6 mm Aluminium Strips

3

2538

7616.85

... More
cmy282 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN

8

3180

25445.12

... More
cmy283 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP

2

1091

2183.6

... More
cmy284 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm

25

406

10171.25

... More
cmy285 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 12 Way SP and N

2

2398

4797.74

... More
cmy286 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 pole

2

4695

9391.54

... More
cmy287 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 4 Way TP and N

2

4159

8318.28

... More
cmy288 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole

2

5711

11422.7

... More
cmy289 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON and OFF energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 32 A DP

8

761

6089.36

... More
cmy290 - Fixing Danger Board

12

82

988.8

... More
cmy291 - Supply and installation in position, testing and commissioning 6kg Fire Ex tinguisher Mono Ammonium Phos phate Powder 50 Stored Pressure Type Pressure Gauge Gross Weight 9.5 Kg empty weight 3.5 Kg Can Height 435MM Diameter 160MM Discharge Time less than 9 Sees, Controllable discharge mechanism Squeeze grip with easy snap safety seal Range minimum 4 meters applicable on Class A 8 C and electrically started Fire A Rating 3A 8 Rating 218 Can construction Deep drawn and Co Mig welded valve Construciton Forging and Mechining Internal Coating of Can Epoxy powder coating External Coating of Can Epoxy PoIyster power coating Sheet metal thickness 1.60MM 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc including cost cost of supporting materials like MS stand and accessaries if it is fixing n floor MS brackets and accessories if it is fixing on wall labour usage charges of machinery complete as per specificed.with regards to general guidelines of fire safe

4

2935

11742

... More
cmy292 - Supplying of four bucket stand alongwith buckets Complete

2

1905

3811

... More
cmy293 - Supplying of Hand gloves complete

1

1004

1004.25

... More
cmy294 - Supplying of first aid box Complete

1

618

618

... More
cmy295 - Supplying of SAFETY MASK Complete

1

154

154.5

... More
cmy296 - Supplying of FIRST AID CHART with lamination Complete

2

412

824

... More
cmy297 - Supplying and installation of RUBBER MAT 1mtr x 1mtr 1Omm thick complete including cost of materials labour usage charges of machinery complete as per specifications

4

1957

7828



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.