Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Opening Date24 Jan 2025
Closing Date31 Jan 2025
Tender Amount₹ 43,84,614.08 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Erection of HT Metering Cubicle, LT Metering Cubicle, LT Feeder Piller Box, LT Distribution Box Erection of HT metering Cubicle on Platform.

1

1936

1936.2

... More
005 - 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification(Dwg No. BESCOM/GM/QS&S/- Dtd 24.11.2018

1

255645

255645.6

... More
006 - Fabricating supplying and mounting MS box made out 14 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG

60000

-

31200

... More
007 - Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips (5.40.2)

1

3606

3606.75

... More
008 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism FOUR POLE FOUR POLE 700-800 A 50 kA

1

52395

52395

... More
009 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism FOUR POLE FOUR POLE 250 A 36 kA

2

24722

49444.5

... More
010 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism200 A 36 kA

1

22495

22495.2

... More
011 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism100 A 25 kA

3

8911

26734.05

... More
012 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. 50-63 A TPN

1

3242

3242.4

... More
013 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. 6-32 A TPN

3

1802

5408.55

... More
014 - Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board

2

474

949.2

... More
015 - Supplying, fixing and wiring 0 to 100 A Direct Reading AC analog type Ammeter

2

550

1100.4

... More
016 - Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT

2

504

1008

... More
017 - Supplying, fixing and wiring rotary selector switch suitable for Ammeter

4

210

840

... More
018 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter

4

168

672

... More
019 - Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter

2

1496

2992.5

... More
020 - Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer

6

882

5292

... More
021 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

18

540

9733.5

... More
022 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. (5.210)

1

9717

9717.75

... More
023 - SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS81301984and(Virgin)PVCinsulationsheathedsuitableforworking voltage upto 1100 Volts as per IS-694:1990 3C x 2.5 mm2

400

118

47460

... More
024 - SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS81301984and(Virgin)PVCinsulationsheathedsuitableforworking voltage upto 1100 Volts as per IS-694:1990 4C x 4 mm2

380

236

89775

... More
025 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greaterthan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greaterthan IK08. Power Factor greaterthan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiencygreaterthan130lm/w, nominal CRI greaterthan75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 100W

20

9960

199206

... More
026 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greaterthan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greaterthan IK08. Power Factor greaterthan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiencygreaterthan130lm/w, nominal CRI greaterthan75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 150W

10

13114

131145

... More
027 - Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.

30

170

5103

... More
028 - 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)

0.1

934149

93414.93

... More
029 - 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm

1

4270

4270.35

... More
030 - 12 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm

8

3931

31449.6

... More
031 - 13 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm

4

4270

17081.4

... More
032 - Making and Fixing pot head for HT Cable only Heat shrinkable Type Terminations 3x95 to 3x150 Sqmm

12

2790

33490.8

... More
033 - Caution/Danger Board

5

157

787.5

... More
034 - Supplying and Providing Pre cast Cable Route/ Joint marker using M15 grade Concrete, MS rods of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.

10

359

3591

... More
035 - Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmallroundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia

4

3685

14742

... More
036 - Supplyingfixingandwiringearthelectrodeforgroundingoflifts,transformers,DGsetsetc.using40mmdia2.9mmthick2.5mlongGIpipewithGIfunnelwithmeshandsuitablesizereducerfixedonthetopoftheearthelectrode.ThefunnelshouldbeenclosedinaCCchamberof400x400x400mmwithacastironcover.Theearthelectrodeshallhavestaggeredholesof12mmdiaandtheelectrodeshouldbecovered150mmallroundwithalternatelayersofsaltandcharcoalfromthebottomoftheCCchamber.Theconnectionfromtheelectrode is to be established through GI strip using GI bolts and nuts

10

4468

44688

... More
037 - GI pipe 100 mm (Nominal bore), medium class (including accessories)

20

1417

28350

... More
038 - 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm

60

60

3654

... More
039 - 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm

24

135

3250.8

... More
040 - 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm

32

372

11928

... More
041 - 400 Sqmm Copper Terminal, Apprx Wt: 395 Gm

16

906

14498.4

... More
042 - Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable 3.5 x 400/500 Sqmm

8

751

6014.4

... More
043 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm)

0.1

217553

21755.37

... More
044 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)

0.1

391875

39187.575

... More
045 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)

0.18

905799

163043.874

... More
046 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 400 Sqmm, 3.5 Core, (39 GI Strips - 4 x 0.8 mm)

0.08

1526142

122091.396

... More
047 - Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete

20

97

1953

... More
048 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 Sqmm

0.1

64388

6438.81

... More
049 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm

0.1

32695

3269.595

... More
050 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 120 to 240 Sqmm

0.18

33891

6100.542

... More
051 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 300 to 400 Sqmm

0.08

35884

2870.784

... More
052 - RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section (Dwg No. BESCOM/GM/QS&S/51 Dtd 24.11.2018) as per IS-785

2

8731

17463.6

... More
053 - 11 kV, Horizontal Cross Arm - Galvanised Iron (GI)

4

511

2045.4

... More
054 - 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod)

3

232

696.15

... More
055 - DISC Insulator 45 kN Porcelain

3

535

1606.5

... More
056 - 11 kV, 45 kN Polymeric Insulator

3

195

585.9

... More
057 - 11 kV, 200 Amps Single Break GOS, Vertically Operated

1

14413

14413.35

... More
058 - H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI

2

6374

12749.1

... More
059 - DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - GI

1

9306

9306.15

... More
060 - DOLO Cutout as per IS-9385, Part-1 to 3 DOLO Cutout as per IS-9385, Part-1 to 3 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification

1

6168

6168.75

... More
061 - Erection of 2 Pole Structure using RCC/PSCC Pole 9 to 10 Mtr long

1

4340

4340.7

... More
062 - Providing Spiral Earth Electrode type earthing (without charcoal, salt etc.,)

2

97

195.3

... More
063 - Erection of H-Frame.

2

339

678.3

... More
064 - HG Fuse Unit as per IS-5350 Part-2 11 kV, HG Fuse Unit with Solid Core Insulator(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)

1

1122

1122.45

... More
065 - Lightning Arrester as per IEC-60099-4 10 kV, 5 kA Lightning Arrester Polymeric type with GROUND DISCONNECTOR

3

1663

4989.6

... More
066 - Guy Wire & GI Wire as per IS-2141 7/10 SWG Guy Wire(7/3.251 mm Dia), Std Wt: 680 Kg/KM

0.05

81087

4054.365

... More
067 - GSM modem with connecting cable for remote communicating capabilities

1

15135

15135.75

... More
068 - CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port UNIDIRACTIONAL (Used for HT Installation, LT Metering Cubicle 50-150 KW

1

20595

20595.75

... More
069 - Insulated GOS Operating Handle/Rod for Redesigned & Modified GOS

1

2127

2127.3

... More
070 - Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr

1

542

542.85

... More
071 - GI/Copperstripsforgroundingconnections,usingnecessaryfixingmaterials as required GI/Copper strips 25 x 6 mm GI strip

20

134

2688

... More
072 - GI/Copperstripsforgroundingconnections,usingnecessaryfixingmaterials as required GI/Copper strips 40 x 6 mm GI strip

30

190

5701.5

... More
073 - GI/Copperstripsforgroundingconnections,usingnecessaryfixingmaterials as required GI/Copper strips 25 x 6 mm Copper strip

10

1155

11550

... More
074 - GI/Copperstripsforgroundingconnections,usingnecessaryfixingmaterials as required GI/Copper strips 600 x 600 x 3 mm Copper plate

2

7792

15584.1

... More
075 - 2mmthickperforatedcableGItraywithonexistingMSanglesupportusing necessary GI bolts/nuts and washer or welding as required. 450 x 50 mm

60

958

57519

... More
076 - SupplyingandinstallationofRUBBERMAT1mtrx1mtr-1Ommthick.completeincludingcostofmaterials,labour,usagechargesofmachinerycomplete as per specifications

2

1995

3990

... More
077 - Supplying of four bucket stand alongwith buckets. Complete

1

1942

1942.5

... More
078 - FRP Telescopic Discharge Rod 10 ft (Comprising of 2 Sticks, Closed Height of 6 Ft and extended Height of 10 Ft.Outer Dia of the stick as followsTop Section: 25 mmBottom Section: 30 mmWall Thickness: 2.25 mmTotal Weight: 2.8 Kgs (Rod: 1.5 Kgs + Earth Cable & Clamp: 1.3 KgsTolerannce for Weight/Length/Dia: +/- 5%))

1

6098

6098.4

... More
079 - SupplyingPVCflexibleconduitpipe.mmdiafixingonsurfaceoverinvertedtaperedwoodenplugsorphillplugsorrawlplugsandclampedusingheavygaugesaddlesatanintervalof300mmusingNFscrews and on either end of the pipe terminated completely 25 mm

200

23

4620

... More
080 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete(Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0,110mm dia

150

492

73867.5

... More
081 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete(Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE Grade PE80-PN6.0, HDPE Grade PE80-PN6.0, 75mm dia

100

257

25725

... More
082 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work

153.2

254

38928.12

... More
083 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite / trap/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates

22.08

6601

145757.808

... More
084 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

4.08

6639

27087.732

... More
085 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

24.69

6708

165631.6305

... More
086 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge

10.3

384

3958.29

... More
087 - Providing and laying in position '40mm down size at Transformer Yard

36

1249

44982

... More
088 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Instringers,treads, landings etc. of stair cases, including use of chequered plate wherever required,allcompleteincluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge

212

118

25153.8

... More
089 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Instringers,treads, landings etc. of stair cases, including use of chequered plate wherever required,allcompleteincluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge

613.64

118

72808.386

... More
090 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge

68

937

63760.2

... More
091 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge

136

52

7140

... More
092 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge

163.5

120

19742.625



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.