Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Civil And Construction
Building Construction
Opening Date26 Aug 2024
Closing Date9 Sep 2024
Tender Amount₹ 10,59,793.96 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Repair of pull and push type rolling shutters of made of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations the which ever parts unserviceable should be replace (Springs, wheels, Shaft & replace the leafs which corroded) new one with all necessary including cost of materials, labour, complete as per specifications including cost of all materials, with all lead,

22.5

518

11657.025

... More
code05 - Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage units, furnitures,electrical & electronic equipments, doors, windows, curtains, blinds etc., including cleaning of dust, etc., using suitable bombay broom stick, squezers

818.699

3

2529.77991

... More
code06 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement trenching, refilling and testing of joints complete. ( External Work) - 25mm nominal OD pipes

71

304

21646.48

... More
code07 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & testing of joints complete. ( External Work Exposed on Wall.) - 20mm nominal OD pipes

25

249

6231.5

... More
code08 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) - 15mm nominal OD pipes

35

318

11139.45

... More
code09 - Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings &fixtures for tank shall be paid separately.

1500

9

13905

... More
code10 - Providing and fixing brass stop cock of approved quality 15mm nominal bore

14

307

4311.58

... More
code11 - Providing and fixing brass bib cock of approved quality 15mm nominal bore

6

294

1767.48

... More
code12 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25mm nominal bore

3

565

1696.41

... More
code13 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 110mm dia., 6 kg/sqcm & class 3

50

423

21166.5

... More
code14 - Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover

2

4934

9869.46

... More
code15 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth

2.4

97

234.84

... More
code16 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work

14.4

105

1512.864

... More
code17 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates

2.4

6168

14804.808

... More
code18 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates Form work for Walls of Item No 2.4.2 at 8%

10.56

7033

74275.9776

... More
code19 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other types of works

0.739

81381

60140.80287

... More
code20 - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.

41.6

488

20309.952

... More
code21 - Construction of M30 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawing

9.6

8074

77512.032

... More
code22 - Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick

30

83

2502.9

... More
code23 - Supplying and fixing PVC/metal conduit accessories.(Vol-6 P.No 3 SL No 1.5.2)deep junction box 25mm junction box

40

57

2307.2

... More
code24 - Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely (3/1.9.2)25 mm

15

22

339.9

... More
code25 - Supplying 4 mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws(9/3.8)

1000

-

420

... More
code26 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (8/3.3.1) 1-2Way

10

106

1060.9

... More
code27 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (8/3.3.6)10-12Way

20

268

5376.6

... More
code28 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(8/3.5.1) 1 to 2 Module

10

141

1411.1

... More
code29 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(8/3.5.6)10-12 Moudule

20

354

7086.4

... More
code30 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293. (Vol-6 P.No 9 SL No 3.6.1) 6Amps one way.

160

105

16809.6

... More
code31 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (Vol-6 P.No 9 SL No 3.6.3)6A Three Way socket

40

176

7045.2

... More
code32 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (Vol-6 Vol-6 P.No 9 SL No 3.6.4) Stepped Fan Regulator Two Module

20

367

7354.2

... More
code33 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (Vol-6 P.No 9 SL No 3.6.9) 32A DP Switch

5

335

1678.9

... More
code34 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (Vol-6 P.No 9 SL No3.6.10) 6/16A Universal Socket

5

243

1215.4

... More
code35 - Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws.(Vol-6 P.No 9 SL No 3.10.2) 90mm

40

10

412

... More
code36 - Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(Vol-6 P.No 5 SL No 2.2.1) Short point up to 3Mtr from tapping point to out let via switch

40

277

11082.8

... More
code37 - Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(Vol-6 P.No 5 SL No 2.2.2) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch

40

390

15614.8

... More
code38 - Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(Vol-6 P.No 5 SL No 2.2.3) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

40

571

22866

... More
code39 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (Vol-6 P.No5 SL No 2.3.1) 1 mm2

400

19

7828

... More
code40 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (Vol-6 P.No5 SL No 2.3.2) 1.5 mm2

400

26

10712

... More
code41 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (Vol-6 P.No5 SL No 2.3.3) 2.5 mm2

800

43

34608

... More
code42 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . (Vol-6 P.No5 SL No2.3.4)4 mm2

400

64

25956

... More
code43 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . (Vol-6 P.No5 SL No2.3.5)6 mm2

40

94

3790.4

... More
code44 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (Vol-6 P.No 17 SL No 5.18.4)6-32 Amps DP

4

761

3044.68

... More
code45 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (Vol-6 P.No 18 SL No 5.18.9)50-63 Amps TPN

1

3180

3180.64

... More
code46 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 Amps 4 pole (Vol-6 P.No 18 SL No5.20.8)

1

5301

5301.41

... More
code47 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.(Vol-6 P.No 18 SL No 5.19.9 )II- Double Door 12Way SP &N

1

2398

2398.87

... More
code48 - Fabricating supplying and mounting MS box made out SWG suitable for floor or wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.18SWG(Vol-6 P.No 19 SL No 5.42.3)

30000

-

11700

... More
code49 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm(Vol-6 P.No 19 SL No 5.41.2)

2

406

813.7

... More
code50 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips (Vol-6 P.No18 SL No 5.40.1)

0.5

2538

1269.475

... More
code51 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 100Amps(14/5.7.4)

3

711

2135.19

... More
code52 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm allround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.(Vol-6 P.No 54 SL No 12.57)

2

4383

8767.36

... More
code53 - GI/Copper strips for grounding connections, using necessary fixing materials as required. (Vol-6 P.No 54 SL No 12.58.2)2 x 3 mm GI Strip

20

131

2636.8

... More
code54 - Supplying of ..... feet - LED PVC Square Batten ..W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50Hz & Power factor 0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition ( Vol-6 P.No 43 SL No11.3.2)LED light fitting 1 x 4' - 20/22 W

80

710

56856

... More
code55 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm)(Vol-6 P.No 30 SL No 6.2.1)

4

3058

12232.28

... More
code56 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.(30/6.3.2)56" Sweep (1200mm)

40

3121

124877.2

... More
code57 - Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. (Vol-6 P.No 56 SL No 13.7.1)On wall / ceiling /Rafter / Girders

100

125

12566

... More
code58 - Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook wisth fan regulator to the existing board together wisth wupplying and fixing 5amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (Vol-6 P.No 57 SL No 13.10)

40

176

7045.2

... More
code59 - Extra length of GI pipe of class B 19mm dia for down rod. (Vol-6 P.No 57 SL No 13.12)

40

202

8116.4

... More
code60 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with ufficient length of 23 / 0.0076 inch PVC insulated twin core wire.(Vol-6 P.No 57 SL No 13.14)

4

506

2027.04

... More
code61 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (ESCOM P.No 13/ SL No 201/32.08) 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) (11 GI Strips - 4 x 0.8 mm)

0.04

185239

7409.5728

... More
code62 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm(ESCOM P.No 52/21.05)

0.04

21512

860.5032

... More
code63 - Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatlydressed disposing off or leveling the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work (Vol I P.No 79 SL No 1.5.1) In ordinary/soft rock without blasting upto 1.5 m depth (0.5*0.75*80)

15

400

6010.05

... More
code64 - Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.(Vol -5 Water Supply P.No 128 SL No 11.3.6) Heavy Duty GI pipe of 50mm dia

3

699

2098.11



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.