Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Civil And Construction
Civil Works Others
Opening Date2 Sep 2024
Closing Date10 Sep 2024
Tender Amount₹ 30,21,231.3 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)

1.63

12998

21188.1744

... More
code05 - KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)

28.62

8258

236347.1082

... More
code06 - KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)

4.824

11588

55903.11696

... More
code07 - KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Item No. 2.11 Page No. 18 Vol.1 PWD SR)

2773.1

110

307370.404

... More
code08 - KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)

16.67

7915

131959.2199

... More
code09 - KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,allmaterials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)

128.79

587

75635.7912

... More
code10 - KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)

13.6619

1525

20837.12988

... More
code11 - KSRB 8-8.3.1: Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)

187.56

358

67247.7624

... More
code12 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)

6500

140

910000

... More
code13 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)

518.21

703

364690.2875

... More
code14 - KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)

187.56

123

23238.684

... More
code15 - KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)

187.56

90

16962.9264

... More
code16 - KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)

187.56

90

16962.9264

... More
code17 - KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)

9

3262

29360.52

... More
code18 - KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)

1

30585

30585.95

... More
code19 - KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)

240

560

134404.8

... More
code20 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Three Pole- 100 A 25 kA (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24)

5

7396

36984.6

... More
code21 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Four Pole-100 A 25 kA (P.No.17, I.No.5.15.9 in CSR Electrical SR Volume-6 2023-24)

5

10315

51575.45

... More
code22 - Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.16-32 A SP (P.No.21, I.No.5.46.1 in CSR Electrical SR Volume-6 2023-24)

6

255

1531.38

... More
code23 - Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 63 A TP (P.No.21, I.No. 5.46.6 in CSR Electrical SR Volume-6 2023-24)

5

1452

7262

... More
code24 - Supplying.........A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Strips (P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24)

12

2995

35951.52

... More
code25 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron..and M.S.Flat......with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24)

6

370

2224.14

... More
code26 - Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24)

35000.04

-

21000.024

... More
code27 - Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15 , I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24)

2

1567

3135.72

... More
code28 - Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)

2

5886

11772.36

... More
code29 - Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)

3

1616

4849.44

... More
code30 - Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 16 Amps (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24)

2

549

1099.02

... More
code31 - Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 32 Amps (P.No.9, I.No.3.13.4 in CSR Electrical SR Volume-6 2023-24)

2

741

1482.44

... More
code32 - Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)

4

565

2260.64

... More
code33 - Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)

1

549

549.36

... More
code34 - Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)

4

243

972.28

... More
code35 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)

1

194

194.46

... More
code36 - Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)

4

683

2732.2

... More
code37 - Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24)

1

1185

1185.01

... More
code38 - Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)

5

583

2916.95

... More
code39 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.3.5Cx50 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.11 Pg.13

0.03

217523

6525.7134

... More
code40 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.08 Pg.13

0.02

218582

4371.6478

... More
code41 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx16 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.05 Pg.13

0.02

172394

3447.8952

... More
code42 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx10 Sqmm Cu Ar cable.ESCOM SR 2023-24 I No. 32.03 Pg.13

0.02

143422

2868.4412

... More
code43 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT cable 2.5 to 25 sqmm ESCOM SR 2023-24 I No. 21.05 Pg.52

0.06

25384

1523.0904

... More
code44 - 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 21.06 Pg.52

0.03

37846

1135.3902

... More
code45 - Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24 In all kind of soils, Depth upto 1.50m

6.75

588

3970.6875

... More
code46 - Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations 2.5 to 25 Sqmm .ESCOM SR 2023-24 I No. 22.13 Pg.53

12

114

1370.88

... More
code47 - Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53

2

230

461.84

... More
code48 - Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2 19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2

25

83

2096.5

... More
code49 - 25mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2

25

98

2461

... More
code50 - 32mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2

20

128

2576.6

... More
code51 - 40mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2

20

181

3621.8

... More
code52 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch. PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5

10

346

3463.8

... More
code53 - Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch .PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5

10

478

4788.6

... More
code54 - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5

6

692

4156.62

... More
code55 - Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5

5

860

4302.5

... More
code56 - Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5

2

1257

2515.86

... More
code57 - Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.1.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5

200

23

4618

... More
code58 - 1.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5

80

31

2528

... More
code59 - 2.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5

80

51

4083.2

... More
code60 - 4.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5

40

76

3062.8

... More
code61 - 6.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5

30

111

3354.3

... More
code62 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8

5

418

2090.45

... More
code63 - 3 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-5

4

195

782.68

... More
code64 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way PWD Electrical SR-2023-24, ITEM NO:3.3.2 ,CH-3, PAGE NO-8

5

150

753.5

... More
code65 - 10-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8

5

317

1586.05

... More
code66 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9

4

123

495.88

... More
code67 - 6A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9

4

207

831.32

... More
code68 - 6/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9

2

286

573.66

... More
code69 - Supply & fixing of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000hr Lumen Maintenance of 70%, CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. PowerFactor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage /Overload, short circuit/ miss-wiring protection.Compatible for pole mauling with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60 Hz application.Compliance to IS 10322/IEC60598 ,LM79 & LM80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with.......W System Power consumption.LED Efficiency 1301m/w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier wordmark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working understand ard electrical conditions as mentioned above should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source. LED flood light 100W PWD Electrical SR-2023-24, ITEM NO:11.9.2, PAGE NO-46

2

11529

23058.56

... More
code70 - GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54

40

99

3986.4

... More
code71 - 2 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55 300x50mm

10

713

7134.3

... More
code72 - Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54

2

4266

8532.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.