Department Of Youth Empowerment And Sports Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Department Of Youth Empowerment And Sports - DYES Tender
Civil And Construction
Electrical Cables And Wires
Electrical and Electronics
Opening Date10 Sep 2024
Closing Date20 Sep 2024
Tender Amount₹ 18,70,311.96
Costs
EMD
₹ 46,758Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DYES/2024-25/EL/WORK_INDENT13Bid Award Id
ViewTender No
DYES/2024-25/EL/WORK_INDENT13Tender Authority
Department Of Youth Empowerment And Sports ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
ITEM04 - Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm (V-6/P.No.-13/I.No.-32.13)
0.234
410536
96065.541
... More
ITEM05 - Laying and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortor complete (I no 29.19,pg no 64vol 6,SR 2023-24)
584
38
22484
... More
ITEM06 - Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr .(I no 29.07,pg no 63,Vol 6, SR 2023-24)
323.64
176
56960.64
... More
ITEM07 - Supplying of on load change over switches 4 poles,AC-23A Duty,415V,50Hz,ACSupply. Withallaccessories. (SMEnclosure Sheet Metal Execution) 400 A (5.12.6)
3
32942
98826
... More
ITEM08 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100percent lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. four pole,400 A 36 kA (5.15.16,SR 2023-24)
3
31037
93112.8
... More
ITEM09 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100percent lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism four pole, 250 A 25 kA (5.15.13,SR 2023-24)
12
23530
282361.2
... More
ITEM10 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100percent lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanismfour pole,125 A 25 kA (5.15.10,SR 2023-24)
12
11375
136501.2
... More
ITEM11 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100percent lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism three pole,125 A 25 kA (5.15.2,SR 2023-24)
3
9457
28373.4
... More
ITEM12 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100percent lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism three pole, 250 A 25 kA (5.15.5,SR 2023-24)
3
18670
56010.9
... More
ITEM13 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete .400 A 4 x 50 x 10 mm Aluminium Strips(I no 5.40.3)
111
4889
542734.5
... More
ITEM14 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVARsuitable for 3phase, 4wire LT network with IP54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy (5.33)
3
10246
30739.5
... More
ITEM15 - Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and-CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.(5.31)
3
4829
14487
... More
ITEM16 - Supplying, fixingandwiringearth leakage relaywithcorebalanced current transformer suitable for single phase50HzACwithlatest microcontrollerbased, digital read out of percentage leakage current, programmable delay/auto/manual reset facilitysuitable tomounton DIN rail/ flush mounting on panel board.(5.21)
3
10180
30541.5
... More
ITEM17 - Supplying, fixing andwiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer.(5.36)
3
924
2772