Department Of Archaeology Museum And Heritage Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Department Of Archaeology Museum And Heritage Tender

Electrical and Electronics
Electrical Works
Opening Date5 Mar 2024
Closing Date26 Mar 2024
Tender Amount₹ 16,21,272.6 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - b) 400 A 4 x 50 x 10 mm Aluminium Strips

2

4445

8890

... More
code05 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

12

515

6180

... More
code06 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy

1

9315

9315

... More
code07 - Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.

3

562

1686

... More
code08 - Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. a) 100 A

1

4503

4503

... More
code09 - b) 160 A

9

6299

56691

... More
code10 - Supplying and fixing HRC fuse units base on existing switch / panel board. 100 to 300 A

30

919

27570

... More
code11 - Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703. Above 63 A to 200 A

30

381

11430

... More
code12 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 250 A 35 kA

1

23545

23545

... More
code13 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT

1

1703

1703

... More
code14 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 6-32 A DP

80

739

59120

... More
code15 - b) 40 A TPN

6

3044

18264

... More
code16 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole

6

5545

33270

... More
code17 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 12 Way SP & N

4

2329

9316

... More
code18 - Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19/20 mm dia 2 mm thick

200

69

13800

... More
code19 - b) 25 mm dia 2 mm thick

200

81

16200

... More
code20 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25 mm

100

35

3500

... More
code21 - Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm

100

29

2900

... More
code22 - Supplying Galvanized steel flexible conduit pipe....mm dia fixing on surface over inverted tape red wooden plugs or phillp lugs or rawl plugs and clamped using heavy gauges add lesatan interval of 300 mm usingNFscrews and on either end of the pipe terminated completely 40 mm

50

90

4500

... More
code23 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. a) 1.5 mm2

500

26

13000

... More
code24 - b) 2.5 mm2

1000

42

42000

... More
code25 - c) 4 mm2

500

63

31500

... More
code26 - d) 6 mm2

200

92

18400

... More
code27 - f) 10 mm2

100

167

16700

... More
code28 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010 a) 3C x 2.5 mm2

100

113

11300

... More
code29 - b) 3C x 4 mm2

50

172

8600

... More
code30 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. a) 6A One Way Switch

100

102

10200

... More
code31 - b) 6A Three Way socket

50

171

8550

... More
code32 - c) Stepped Fan Regulator Two Module

10

357

3570

... More
code33 - d) 6A Bell Push

10

177

1770

... More
code34 - e) 32A DP Switch

10

326

3260

... More
code35 - f) 6/16A Universal Socket

10

236

2360

... More
code36 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. a) 6A Three Pin Top

10

87

870

... More
code37 - b) 6A Lamp Holder

20

74

1480

... More
code38 - c) 6A Bell Buzzer

10

130

1300

... More
code39 - d) 16A Three Pin Top

10

115

1150

... More
code40 - Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED light fitting 1 x 4- 20/22 W

50

690

34500

... More
code41 - b) LED light fitting 1 x 4' - 36/40 W

20

1269

25380

... More
code42 - GI/Copper strips for grounding connections, using necessary fixing materials as required. GI/Copper strips 25 x 6 mm GI strip

100

128

12800

... More
code43 - GI/Copper strips for grounding connections, using necessary fixing materials as required. GI/Copper strips 25 x 3 mm Copper strip

50

570

28500

... More
code44 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitablesize reducer fixed on the top of the earth electrode.The funnel should been closed in a CC chamber of 400 x 400 x 400 mm with a cast iron cover.The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts.

10

4256

42560

... More
code45 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.. On wall/ ceiling / Rafter / Girders

60

122

7320

... More
code46 - Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.

25

315

7875

... More
code47 - Rewinding a ... mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing.

10

765

7650

... More
code48 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)

5

2969

14845

... More
code49 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model

10

2984

29840

... More
code50 - Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit 5star 2 Ton capacity

5

54048

270240

... More
code51 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.

5

3175

15875

... More
code52 - Supplying wall mounting fan suitable to operate at singlephase 230v AC. supply. 400 mm Sweep

10

3212

32120

... More
code53 - Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS

1

68383

68383

... More
code54 - Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. 150 AH capacity

4

28187

112748

... More
code55 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

12

515

6180

... More
code56 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)

120

79

9507.6

... More
code57 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 120 Sqmm, 3.5 Core, (23 GI Strips - 4 x 0.8 mm)

300

456

137064

... More
code58 - Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting sockets/coupling/Tees/Bends/End caps of same materials in existing trench as per IS 14930 part II suitable for drawing under ground cables. 90 mm OD/ 32 mm ID

300

250

75000

... More
code59 - Heavy Duty Copper Terminal Long Barrel a) 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm

100

27

2700

... More
code60 - b) 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm

4

89

356

... More
code61 - c) 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm

12

140

1680

... More
code62 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 120 to 240 Sqmm

300

32

9681

... More
code63 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil

100

260

26000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.