Central Food Technological Research Institute Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Central Food Technological Research Institute - CFTRI Tender

Works
Electrical and Electronics
Eprocure
Opening Date17 Sep 2024
Closing Date23 Sep 2024
Tender Amount₹ 3,56,649 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, Testing and Successful Commissioning of 12 Inch Dia, 300 mm sweep, industrial type ready to use Exhaust Fan having Bird Cage with 1.5 FRLS PVC insulated, copper conductor, single core cable and to fix with required size of MS frame duly painted with one coat of primer and 2 coats of paint, suitable hardwares etc., and provide one no. of 3 Pin 5/6 Amps ISI make Socket along with Gangbox and 3 Pin 5/6A Amps ISI make Plugtop as required. Make for All : Please refer Special Electrical Conditions under Tender Document File.

4

-

-

... More
Supply, Installation, Testing and Successful Commissioning of 8” x 10” Teakwood Switch Board covered with 3 mm thick hylem sheet and consisting of the following pre-wired with 4 sq.mm FRLS copper wire for Phase, Neutral and Earth and ready for use to fix on the wall using neccesssary hardwares as required. a) 15Amps, 5 Pin Flush Type Socket - 2 Nos. b) 15 Amps Flush Type Switch - 2 Nos. c) 5 Amps Flush Type Indicator - 1 No. d) 20 Amps DP, 10kA, 230V MCB - 1 No. Make for All: Please refer Special Electrical Conditions under Tender Document File.

10

-

-

... More
Labour charges for digging 8 feet of depth below ground level, including to remove hard soil / rock / tree root etc., if any encountered, fixing the Item No:10, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:10 as required, as mentioned under S.No.10).

4

-

-

... More
Supply, Installation, Successful Commissioning and Testing of LT Single Door IP55 Indoor Panel Box of size 18" (W) x 18" (H) x 18" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of red oxide & 2 coats of Siemens Gray colour paint and consisting of 1 x 125A, 30kA, 4P MCCB. The Output from the 125A MCCB shall be connected to the existing Power DB using suitable range Copper Cables. Provision for earth connection through bolt & nut to be provided on both sides of the box along with 1 Nos of plate cutting for fixing glands, entry and exit of Copper / UG Cable(s) and the existing 50/70 sq.mm UG Cable shall be terminated to this MCCB. The LT Box shall be mounted on the wall using suitable hardwares. 6" x 6" water proof vents shall be provided on both the sides of the Panel, covered with wire mesh from inside and LED Indicator Lights for R,Y and B. Make for All: Please refer Special Electrical Conditions under Tender Document File. Panel Design: As per Engineer In-Charge. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker.

1

-

-

... More
Supply, Installation, Successful Commissioning and Testing of LT Double Door IP55 Indoor Panel Box of size 30" (W) x 36" (H) x 20" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of red oxide & 2 coats of Siemens Gray colour paint and consisting of items as mentioned in a) to e) & g). At the bottom of the Panel, 1 x 200A, 30kA, 4P MCCB shall be fixed. The Output from the 200A MCCB shall be connected to 4 x 250A range Copper Bus-Bars using Copper Cable / Copper Bus-Bar. From the Bus-Bar, input shall be tapped for 2 x 125A MCCB through rated copper cable / copper bus-bar and to 3 x 63 Amps 4 Pole RCCB through rated FRLS multistrand copper wire using suitable type of lugs and standard colour code of wiring, neatly dressed. All Lighting Circuit (Lights & Fans), Switch Board Cicuits to be connected to this LT Panel. A Separate Aluminium Bus-Bar for connecting the Sub-Circuits Earth Wires in the Panel and extended for 2 Inches outside the Panel on both sides, for connecting Bare Copper Wires from the Earthpit should be provided. 3 Nos of plate cutting for fixing glands, entry and exit of Copper / UG Cable(s), Cable Alley are to be made available. The panel shall be have individual hinges with locking arrangement doors for each MCB / RCCB / MCCB distribution chamber within the compartment. The LT Box shall be mounted on the floor with total stand height of 0.75-1.5 Feet grouted to the floor, doors on front with locking arrangements. The stand portion from the floor on all 4 sides shall be suitable covered with removable type metal sheet (screwed to the stand) painted with same colour as of LT Box. All visible Bus-Bars inside the Panel shall be suitably covered with the 6mm Hylem sheets from. 6" x 6" water proof vents shall be provided on both the sides of the Panel, covered with wire mesh from inside. a) Copper Bus Bar of size 50mm x 5 mm insulated with fire proof tape, mounted on Bus Bar Insulators - 04 Nos; b) 200A, 36KA, 4Pole MCCB - 01 No; c) 125A, 36KA, 4Pole MCCB - 02 No.; d) 63A, 4P RCCB 440V AC with 30mA sensitivity - 03 Nos.; e) RYB LED Phase Indication Lamps with Fuse Unit for Input and Output - 2 Sets; f) HT Rubber Mat of 6' x 3' - 01 No.; g) Aluminium Earth Bus-Bar 50mm x 5mm - 01 No. Important: All incoming / outgoing armoured cables / Sub-Main Circuits shall be terminated with suitable size copper / aluminium lugs (for copper cables / wires, coppler lugs and for aluminium cables / wires, aluminium lugs). During connections, if any Incoming / Outgoing cables is / are need to be extended, part of the work (Cable / Wires for extension of connection will be provided by CSIR-CFTRI). S.No: a), e), f) & g) Make: Any ISI Brand; S.No: b), c) & d) Make : Please refer Special Electrical Conditions under Tender Document File. Panel Design: As per Engineer In-Charge. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker.

1

-

-

... More
Group A wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make for All : Please refer Special Electrical Conditions under Tender Document File.

10

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make: Same as Item No: 8.

120

-

-

... More
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. Note: Masonry enclosure size is 1.5 Feet x 1.5 Feet x 1.5 Feet. As per IS 3043, charcoal/ coke and salt should be refilled with 50 Kg each per earthpit. The copper plate has to be coated with tin, connected copper flat(s) / 2 runs of 4.0 dia solid copper wire (from bottom of the plate upto top of the funnel) and GI Pipe are tto be brazed / bolted and only SS nut, bolts and washers to be used.

4

-

-

... More
Providing and laying earth connection from earth electrode with 4.00mm dia copper wire in 15mm G.I. pipefrom earth electrode including connection with copper thimble excavation and refilling as required.

60

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.

10

-

-

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

1

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 35 sq. mm and upto 95 sq. mm (clamped with 25 x 3mm MS flat clamp) on wall surface as required.

70

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3 1/2 x 35 sq.mm (32mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Lugs and Brass Compression Gland Make: Please refer Special Electrical Conditions under Tender Document File. Note: Each means, all leads at one end of the Cable.

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3 1/2 x 50 sq.mm (35mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Lugs and Brass Compression Gland Make: Please refer Special Electrical Conditions under Tender Document File. Note: Each means, all leads at one end of the Cable.

1

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3 1/2 x 70 sq.mm (38mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Lugs and Brass Compression Gland Make: Please refer Special Electrical Conditions under Tender Document File. Note: Each means, all leads at one end of the Cable.

1

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerence as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required. Ceiling Fan Make: Make: Please refer Special Electrical Conditions under Tender Document File. Note: a) The fan should have an connectivity option to control the motor speed through Mobile Phone App of both Android & iPhone b) For the chosen make by the contractor from the choice of brand given as in above, the fan colour be as per the choice of the Engineer Incharge.

6

-

-

... More
Demolishing cement concrete Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-incharge.

1

-

-

... More
Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tampling complete.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.