Bruhat Bengaluru Mahanagara Palike Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Bruhat Bengaluru Mahanagara Palike - BBMP Tender
Electrical Generators And Transformers
Electrical and Electronics
Opening Date10 Feb 2025
Closing Soon17 Feb 2025
Tender Amount₹ 25,42,081.05
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
₹ 640
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
BBMP/2024-25/EL/WORK_INDENT6468Tender No
BBMP/2024-25/EL/WORK_INDENT6468Tender Authority
Bruhat Bengaluru Mahanagara Palike ViewPurchaser Address
-Website
http://http://bbmp.gov.in/home
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Others - GUBBI VEERANNA RANGA MANDIRA LOCATION
BOQ Items
... More
code04 - Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition.LED square or round down light 15-18W
80
1324
105920
... More
code05 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4' - 20/22 W
80
690
55200
... More
code06 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep 1200 mm Regular model
15
2984
44760
... More
code07 - Supplying wall mounting fan suitable to operate at single- phase
230v AC. supply400 mm Sweep
15
3212
48180
... More
code08 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep 300 mm
5
2969
14845
... More
code09 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2
3000
26
78000
... More
code10 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2
3000
42
126000
... More
code11 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2
2000
63
126000
... More
code12 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 mm2
1500
92
138000
... More
code13 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch
80
102
8160
... More
code14 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket
80
171
13680
... More
code15 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
15
357
5355
... More
code16 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32 A DP Switch
40
326
13040
... More
code17 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket
40
236
9440
... More
code18 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way
10
177
1770
... More
code19 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way
10
220
2200
... More
code20 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way
10
261
2610
... More
code21 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
10
319
3190
... More
code22 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 2 Module
10
137
1370
... More
code23 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 Module
10
175
1750
... More
code24 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module
10
234
2340
... More
code25 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module
15
284
4260
... More
code26 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box10-12 Module
10
344
3440
... More
code27 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 A SP
40
793
31720
... More
code28 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN
20
3088
61760
... More
code29 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG MS enclosure.II - Double Door 4 Way SP & N
10
1524
15240
... More
code30 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG MS enclosure.II - Double Door 8 Way SP & N
3
1854
5562
... More
code31 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG MS enclosure.II - Double Door 12 Way SP & N
3
2329
6987
... More
code32 - Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum
IP43 protection provided with Polyurethane PUR gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable
type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of
single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 8 Way
3
12605
37815
... More
code33 - Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum
IP43 protection provided with Polyurethane PUR gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable
type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of
single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way
2
15529
31058
... More
code34 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA
4
8487
33948
... More
code35 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia
5
3510
17550
... More
code36 - Supply and installation of 9kg Fire Extinguisher Mono Ammonium Phos phate Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight 14.9 Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter 175M M, Discharge Time less than 13Secs, Controllable discharge mechanism Squeeze grip with easy snap safety seal, Range minimum 4 meters, applicable on Class A,B, C and electrically started Fire, A Rating 4A, B Rating 348, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 2.00 M M, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete IS 15683 and CE Approved
5
3100
15500
... More
code37 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders
160
122
19520
... More
code38 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
15
171
2565
... More
code39 - Fixing one exhaust fan in the nitch already left in the wall with boltsand nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire
5
492
2460
... More
code40 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm
20
395
7900
... More
code41 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete 14 SWG
145000
-
72500
... More
code42 - Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.
40000
-
14000
... More
code43 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 A 4 x 30 x 6 mm Aluminium Strips
10
2465
24650
... More
code44 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, 11 GI Strips - 4 x 0.8 mm
0.6
141842
85105.2
... More
code45 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 120 Sqmm, 3.5 Core, 23 GI Strips - 4 x 0.8 mm material code 287212
0.35
456889
159911.15
... More
code46 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm
0.95
20886
19841.7
... More
code47 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Ordinary Rock without Blasting
250
345
86250
... More
code48 - DIESEL GENERATOR SET 10. 1 Supplying installing testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per BS 5514 ISO 3046 ISO 8528 & IS 1002 ISO 3046 Generator set specifications. Engine Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled four stroke and multi cylinder conforming to ISO 3046. The scope of supply includes Electrical starter motor12V DC Battery charging alternator Bosch fuel system with mechanical governor A1 Class. Spin on lube oil filter Spin on dual fuel filter with water separator Turbocharger Charge air cooler Silencer Hospital grade Dry type air cleaner Shutoff coil Flywheel and flywheel housing First fill of lube oil and coolant Safety for low lube oil pressure Safety for high water temperature Permissible overload of 10 percent for one hour in 12 hours of operation Capacity of Fuel Tank Fuel tank suitable for 8 hours of operation Alternator Alternator is suitable for operation at 1500 RPM 415 V 0.8 pf lag suitable for 50 Hz 3 phase 4 wire systems conforming to IS IEC 60034 1. The Alternator is brush less type screen protected revolving field self excited self regulated through an AVR. The alternator shall have 1.0 percent Voltage regulation max in static conditions IP 23 protections with insulation class F&H. Mounting arrangement Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel The control panel is manufactured with 14 16 gauge CRCA sheet and is powder coated for weather proof and long lasting finish. The control panel consists of the following parts PS0500 Controller Aluminium bus bars with suitable capacity within outgoing terminals Indicating lA for Load On and Set Running Instrument fuses duly wired and ferruled MCCB of suitable rating with overload and short circuit protections. Genset Controller microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set manual and remote start stop control shutdown fault indication and an LCD hour counter. The integration of all functions into a single control system providesenhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features Functions protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory Provide Alternator Data. Voltage 1 ph or 3 ph line to line and line to neutral voltage Current 1 ph or 3 ph kVA 3 ph and total Frequency Provide Engine Data Starting battery voltage Engine running hours Engine Temp Engine oil pressure Control includes provision for Service adjustment and calibration of DG control functions Voltage frequency selection Configurable input and output set up Meter calibration Engine controls Power Start operates on 12 VDC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. Engine Starting The control system supports automatic engine starting Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0 300 sees to start after remote start signal and time delay of 0 600secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include Configurable alarm output Emergency stop Annunciated whenever an emergency stop signal is received by the control. Low lube oil pressure warning and ......30KVA 24kw
1
457067
457067
... More
code49 - Supply, Erection, testing and commissioning of AMF panel suitable
for .....kVA DG set. The panel is of cubical type base/floor mounting
control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No
of starts, Fault indication, over / under speed, Fails to start, Low oil
pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.15 KVA to 30 KVA
1
58711
58711
... More
code50 - Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate
for shaft, IS 2062 for base plate with door opening arrangements,
including suitable boards, Bakelite sheet and MCBs as per IS
specifications suitable to withstand the wind speed of 47 m/s for .......m
Pole in single section and single joint welded as per IS
9595/IS10178AWS having dimensions bottom ..... mm , top.... mm
with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along
with template and the Pole shall be hot dip galvanized in single
dipping with not less than 65micron as per ASTM-A123 and 153 etc.,
excluding foundation as per drawing appended.7 m - Top 70 mm and Bottom 130 mm dia
4
13500
54000
... More
code51 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/umileds/Osram make LED Source. LED Floodlight 200W
20
18581
371620
... More
code52 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
20
162
3240
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%