Bruhat Bengaluru Mahanagara Palike Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bruhat Bengaluru Mahanagara Palike - BBMP Tender

Works
Electrical and Electronics
Electrical Works
Opening Date10 Feb 2025
Closing Soon17 Feb 2025
Tender Amount₹ 25,41,957 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. Supply 400 mm Sweep

15

3212

48180

... More
code05 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)

10

2969

29690

... More
code06 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2

2500

26

65000

... More
code07 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2

2500

42

105000

... More
code08 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2

2500

63

157500

... More
code09 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

104

102

10608

... More
code10 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket

100

236

23600

... More
code11 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch

50

326

16300

... More
code12 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 400W Dimmer

23

276

6348

... More
code13 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 2 Module

22

137

3014

... More
code14 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 Module

25

175

4375

... More
code15 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module

25

234

5850

... More
code16 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module

24

284

6816

... More
code17 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 Module

20

344

6880

... More
code18 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

5

3510

17550

... More
code19 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A SP

26

793

20618

... More
code20 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP

20

739

14780

... More
code21 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN

25

3088

77200

... More
code22 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & N

10

1854

18540

... More
code23 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA

7

8487

59409

... More
code24 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box

100

269

26900

... More
code25 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

100

379

37900

... More
code26 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

100

555

55500

... More
code27 - 3.14 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose

30

78

2340

... More
code28 - 3.14 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose 6A Batten Holder

30

74

2220

... More
code29 - Supplying......TR split Air conditioners suitable for operation on A/C supply single phase 50Hz2 30V with hermetically sealed compressor with air cooled condenser ,motor capacitor and start run capacitors, relay and over load protect or inter nalunit,with one indoor and one outdoor unit Thecondenserunitwillbeplacedoutsidethe room on the terrace to avoid noise including standard length of suitabe size copper tubing covered with insulation tube. (Highwallchorded/cordless) suitable capacity 3core sheathed/PVCcopper cable and a battery operated wireless remote unit 2 Ton capacity

7

54048

378336

... More
code30 - Installation charges for split type air conditioner with allied works for one indoor and one out door unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.

7

3175

22225

... More
code31 - Supplying and installation of insulated refrigerant copper tubing of 5/8"and3/8"with polythene foamin sulation 3 core 80 stand copper wiring between indoor and out door unit Leak testing oil and gas charging for additional piping length of tube Split

35

1549

54215

... More
code32 - Supplying & filling refrigerant(F-22/F/12)for air conditioning equipment's. Which includes the labour&Nitrogen gas for pressure and leak testing.

40

605

24200

... More
code33 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle/L angle of size 6mmx50mm for mounting outdoor/indoor A.C. unit/ Batteries.

9

4807

43263

... More
code34 - Supplying,erecting,testing and commissioning of voltage stabilizer suitable for170to270v input and load variation from noload to full load,with over load protection,spike suppression,operating at 00Cto 400 C. Range etc., complete. 5kVA Capacity

14

9666

135324

... More
code35 - Supplying,erecting,testing & commissioning of ON-LINE UPS system suitable for operation on 230V,50Hz,A/Csupply,with isolation transforme rall accessories complete and Excluding batteries and wiring complete. 3 kVA ON LINE UPS

3

38719

116157

... More
code36 - Supplying,erecting,testing&commissioning of ON-LINE UPS system suitable for operation on 230V,50Hz,A/C supply,with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS

2

68383

136766

... More
code37 - Supplying,installation,testing&commissioningof12V..AHbatteriesinpolypropylenecontainerforD.G.sets.Lowmaintenancebatteries, plate type. 100 AH capacity

9

20133

181197

... More
code38 - Supplying,installation,testing&commissioningof12V..AHbatteriesinpolypropylenecontainerforD.G.sets.Lowmaintenancebatteries, plate type. 150 AH capacity

8

28187

225496

... More
code39 - Supplying and fixing hylumplasticsheet 3mm thick with necessary nitches for fixing switches, regulators etc.,and fixing on existing wood or metal box using N. F. screws.

10000

-

3500

... More
code40 - Fabricating supplying and mounting MS box madeout....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG

85000

-

42500

... More
code41 - Supplying.........A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrink able coloured PVC sleeve, mounted on henolic/FRP/DMC insulator which aremountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips

2

2465

4930

... More
code42 - Supply,Erection,testing and commissioning ofAMF panel suitable for.....kVA DGset.The panel is of cubical type base/floor mounting control panel with hinged doors,undrilled bottom glandplate,aluminium BusBar with the accommodation for.....A4 pole contactor for alternator with thermal O/Lrelay,.....A4 pole contactorformains,HRCfuseforshortcircuitprotection,MicroprocessorbasedAMFmodulewithsupplyfailuretimer,Restorationtimer,3impulseautomaticenginestart/stoplogic,Mains/generatorvoltage,....capacitybypassswitchandfrequencysensing,PCC1301controllerwithwatertemperature/Lubeoilpressure/enginespeed,Voltage/ampere/Frequency/kVA,Running-hourcount,Noofstarts,Faultindication,over/underspeed,Failstostart,Lowoilpleasure,Highenginetemperature,Under/overvoltage,overcurrent,Earthfaultrelay,withindicationsforMainson,LoadonMains,BatterychargeronPushbuttonsAMFmodulebypassMode,BatterychargerunitwithinbuiltAuto/ManualandFlat/Boostfacility.ThecompletesetshallhavesufficientsafetyandadheretoNEC,NBC2016,IEC,CPWDspecifications, PCB norms and KSGEI Acts and Rules .62.5 KVA

1

77768

77768

... More
code43 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

1

515

515

... More
code44 - Supplying ,fixing and wiring 0 to 30V Direct Reading DC Voltmeter/Ammeter.

2

690

1380

... More
code45 - Supplying of on load change over switches 4 poles,AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 125 A

2

10326

20652

... More
code46 - Supplying,fixing and wiring rotary selector switch suitable for Ammeter

1

200

200

... More
code47 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter

1

160

160

... More
code48 - Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay out put for high/low frequency and wiring complete.

1

975

975



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.