Bruhat Bengaluru Mahanagara Palike Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 50,850Document Cost
Refer DocumentsTender Fee
₹ 640
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
BBMP/2024-25/EL/WORK_INDENT6143Tender No
BBMP/2024-25/EL/WORK_INDENT6143Tender Authority
Bruhat Bengaluru Mahanagara Palike ViewPurchaser Address
-Website
http://http://bbmp.gov.in/home
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
code04 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m
210
484
101640
... More
code05 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm
2.11
31139
65703.29
... More
code06 - Heat shrinkable Straight Through Joint LT UG Cable 35 to 95 Sqmm
3
284
852
... More
code07 - 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 1995 3x25 + 1x25 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral)
2.6
164831
428560.6
... More
code08 - Accessories for ABC Cables as per NF-33, as per IS-13573 for Joints & Terminations Suspension Clamp suitable for insulated Messsenger wire of size 25 to 95 Sqmm
4
355
1420
... More
code09 - Piercing Connector Suitable for 16 Sqmm - 95 Sqmm AB Cable - Street Light Connection
25
186
4650
... More
code10 - Dead End Clamp/Anchor Clamp Assembly 25 to 95 Sqmm Bare Messenger(Exclusive of Pole Clamp and Eye Hook)
10
152
1520
... More
code11 - Pre - Insulated Lug - CPTAU for 25 Sqmm
20
287
5740
... More
code12 - Pole Clamp for HT/LT AB cable
80
109
8720
... More
code13 - Stringing of 1.1 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size (3x95) (Phase Conductor) + (1x70) (Insulated Messenger Neutral) + (1x25) (Street Light Control)
2.6
33660
87516
... More
code14 - Installation of Insulation piercing connector for Main to Street Light Main : 16-95 Sqmm, Tap: 1.5-10 Sqmm (EP95)
80
90
7200
... More
code15 - Installation of Pre-Insulated Lug - CPTAU for 25 Sqmm
20
160
3200
... More
code16 - Supply and fixing of 3-pole Capacitor switching contactor with NO/NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest in rush current, fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 60947-4-1.50 KVAR
1
15067
15067
... More
code17 - Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 32 A
9
4090
36810
... More
code18 - Supplying, fixing and wiring heavy duty low voltage capacitors conforming toIS2834. 3phase, 400/440Vgrade, for power factor improvement of rotating machineries like induction motor.
3
480
1440
... More
code19 - Supplyingofmulti function digital meter with three lineback light LCD type display for voltage,Current, frequency, Power, power factor, kVA, kWH, kVARsuitable for 3phase,4wireLTnetwork with IP54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
1
9315
9315
... More
code20 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which aremounted on powder coated 40x6mmM.S.flat framework inexistingpanel board.The busbar shall havesuitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips
2
4445
8890
... More
code21 - Supplying ......... A rated 3phase with neutral bus bar using
required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which aremounted on powder coated 40x6mmM.S.flat framework inexistingpanel board.Thebusbar shall havesuitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250 A 4 x 30 x 10 mm Aluminium Strips
2
3435
6870
... More
code22 - Fabricating supplying and mounting MSboxmade out ....SWG suitableforfloor /wallmounting, fullyweather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessarycable entry pipe with gland and box should be finishedwith7tanks treatment withpowder coatedpaint and finally finished with approved colour etc., complete.18 SWG
62000
-
23560
... More
code23 - Supplyingand fixingangle iron framework fabricatedout ofM.S. angle iron.. andM.S. Flat......withbolts,washers etc., andpainted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm
32
395
12640
... More
code24 - Rotary handle for MCCB
4
3748
14992
... More
code25 - Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter
2
1425
2850
... More
code26 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest microcontroller based, digital read out of percentage leakage current, programmable delay/auto /manual reset facilitysuitable tomounton DIN rail/ flush mounting on panel board.
2
9255
18510
... More
code27 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4PMCCB, all Poles should have protection for Short-Cicrcuit/ Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loadsmust be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal powercircuits to avoidany accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single echanism.FOUR Pole 100 A 25 kA
2
8487
16974
... More
code28 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4PMCCB, all Poles should have protection for Short-Cicrcuit/ Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loadsmust be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal powercircuits to avoidany accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single chanism.Four Pole 160 A 25 kA
1
13447
13447
... More
code29 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4PMCCB, all Poles should have protection for Short-Cicrcuit/ Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loadsmust be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal powercircuits to avoidany accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single echanism.FOUR Pole 400 A 36 kA
1
28216
28216
... More
code30 - Supplying&fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energycross-3 withShort circuitbreaking capacityof10Kandcomplete wiringas requiredconfirmingtoIEC 60898.50-63 A TPN
10
3088
30880
... More
code31 - Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 120 W
80
10060
804800
... More
code32 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 180 W
10
15464
154640
... More
code33 - Supplying and fixing telescopic M.S. bracket fabricated byusing 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracket and are welded with suitable angle, using 6mm thick M. S.sheet, grip bolts & nuts, as required, suitable for 9to12 ms.M.S. tubular pole, with necessary two coats of painting, with all other accessories.Single bracket 1.5 m. Length
80
1461
116880
... More
code34 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existingpole /wall ceilingincluding clamps, bolts, nutsandwiring using suitable capacity wires.
10
162
1620
... More
code35 - Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/GI or any other pipe using required size of reducer, wiring using suitable wires.
80
198
15840
... More
code36 - Supplying & fixing-flexible LED Strip Light ..... WPower consumption in 5ms length CCT6500 degree K,CRI 70%. efficacy 80lumenper W, life 25000 burning hours and Compliance toIS 10322/IEC 60598, LM79 & LM80. The LED are driven by HF electronic driver nonintegrated,with PF 0.95, power loss should 5% of lamp Wage., short circuit &open circuit protection to be integrated in the circuit ,THD less than 20%, Life asper LM79. The operating input voltage should be between 130 to 275 V. BIS Approved with 2 yearsWarranty against any manufacturing defect working under standard electrical condition.
94
1291
121354
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements