Bharat Sanchar Nigam Limited Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 8,670Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Attending Of Major Ht Lt Faults In Electricals Installations In Te Bldgs Under Belagavi Ba.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_212151_1Bid Award Id
ViewTender No
67/CEE/BSNL/BGL/2024-2025Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bsnl.co.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Attending of major HT LT faults in Electricals installations in TE Bldgs under Belagavi BA.
Attending of major HT LT faults in Electricals installations in TE Bldgs under Belagavi BA.
BOQ Items
c) Above 100 KM
2
-
-
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : (Make: Raychem/ss )a) 95 / 120 sq mm (Indoor)
2
-
-
b) 95 / 120 sq mm (Outdoor)
2
-
-
c) 95 / 120 sq mm straight joint
2
-
-
Arresting fault in 11 KV HT breaker switch / HT panel including disconnection of HT cables , and replacing minor spares reconnecting HT cables testing, commissioning on exchange load etc. complete as reqd.
1
-
-
Supplying and fixing of following items/spares for 11 KV substation i/c testing, comm. etc complete as required.a)15 Amp areil DO fuses with porcelein tube
3
-
-
b)11 KV Pin insulator with washers & nuts
3
-
-
c)11 KV disc insulator
3
-
-
d)11 KV lightning arrester with GI clamps, nuts , bolts
2
-
-
e) Complete set of 11 KV Load break switch/AB switch
1
-
-
f) ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc.
20
-
-
g) HT fuses 25 Amps, bolted Type
2
-
-
Supplying & Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium power HT cable of 11 kV grade of ISI Marked of size 3 x 95sq.mm in Following ways etc. as required. ( Make: Polycab/ Havells / ss ) a)direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
10
-
-
b)in the existing RCC/ HUME/ METAL pipe as required.
10
-
-
c)in the existing masonry open duct as required.
10
-
-
Supplying and erection of Potential Transformer of rating 11 KV / 110 V, 50 VA, single phase with insulation level of 15/35/95 KV as per IS 3156 and 0.5 class accuracy i/c testing commissionin etc as required.
1
-
-
Supplying and Fixing of HT current transformer of -/5A of suitable ratio as per site requirement with Burden of 3.75 VA, Accuracy class 0.5 and suitable for 11KV HT supply in the existing HT metering cubicle panel i/c reconnections with existing wires / bus with necessary replacement / suitable modifications as per requirement, e work also involves " Arranging for HESCOM power supply shut down & MRT AEE for testing & commissioning etc., as required. (Make: Kappa/Kalpa/AE/ss/any Hescom approved Make)Note : The HT PT/CTs shall be got Tested from the MRT Lab of HESCOM /BESCOM by the agency apart from Manufacturers test certificate by paying testing fees from their end on behalf of BSNL & nothing extra shall be payable in this regard.
1
-
-
SH-II (Attending faults in LT installations ) Servicing and carrying out maintenance of LT panel including cleaning with blower,tightning of all contacts , checking for of damaged/faulty wires/cables / terminals/connector upto 63amps and attending faults by replacing the same with suitable capacity rating etc complete as required. (Note- This item does not include any major electrical item that is there in LT panel) Note-Only first visit for attending the fault shall be paid by the BSNL. Agency is required to carry spares required for rectification of routine fault with him, The necessary meters / T & P required shall be arranged by the contractor. Any subsequent site visit for attending the fault shall be bourn by contractor and nothing shall be paid by BSNL on this account. a) Up to 50 KM
2
-
-
b) From 51KM to 100 KM
2
-
-
c) Above 100 KM
2
-
-
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker / isolators suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 6 A to 32 Amp SP MCB
3
-
-
b) 16 A to 32 Amp SPN MCB
2
-
-
c) 32 Amp TPN MCB
2
-
-
d) 63 Amp FP isolator
2
-
-
S/F following electrical accessories / items in the existing LT panel etc complete as required. a)63 Amp 4 pole SFU
2
-
-
b)32 Amp 4 pole SFU
2
-
-
c)16 Amp HRC fuses
6
-
-
d)32 Amp HRC fuses
6
-
-
e)63 Amp HRC fuses
6
-
-
h) 1.5 sq mm copper conductor FRLS flexible wire of 1.1 kv grade
50
-
-
i) 4.0 sq mm copper conductor FRLS flexible wire of 1.1 kv grade
50
-
-
j) 10 sq mm copper conductor FRLS flexible wire of 1.1 kv grade
50
-
-
Supplying and laying of one number following size PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 grade in following manner as required. A) On surface of wall clamped with suitable thick GI saddle a) 2 core x 6 sq mm
10
-
-
b) 4 core x 16 sq mm
10
-
-
c) 3.5 core x 25 sq mm
10
-
-
d) 3.5 core x 50 sq mm
10
-
-
b) In existing RCC/Hume/Metal pipe a) 2 core x 6 sq mm
10
-
-
b) 4 core x 16 sq mm
10
-
-
c) 3.5 core x 25 sq mm
10
-
-
d) 3.5 core x 50 sq mm
10
-
-
C) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) 2 core x 6 sq mm
10
-
-
b) 4 core x 16 sq mm
10
-
-
c) 3.5 core x 25 sq mm
10
-
-
d) 3.5 core x 50 sq mm
10
-
-
Supplying and laying 1.1 KV grade, 2 x 10 sq mm aluminium conductor flexible service cable as per following etc complete as required. ( HESCOM approved make) a) on wall surface (clamped with 1mm thick saddle)
100
-
-
b) In air alongwith existing GI Wire
100
-
-
Supplying and laying 1.1 KV grade, 4 x 16 sq mm aluminium conductor flexible service cable as per following etc complete as required. ( HESCOM approved make) a) on wall surface (clamped with 1mm thick saddle)
50
-
-
b) In air alongwith existing GI Wire
50
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 4 core x 16 sq mm
2
-
-
b) 3.5 core x 25 sq mm
2
-
-
d) 3.5 core x 50 sq mm
2
-
-
Supplying and fixing 63 Amps kit-kat fuse with suitable size of fuse wire link etc.complete as required.
5
-
-
Providing and fixing/ Laying 8 SWG dia G.I. wire on surface or in recess for loop earthing / supporting along with existing surface/ recessed conduit/ submain wiring/ cable as required
150
-
-
S/F aluminium lugs of foloowing size for existing power cable i/c making necessary taping, connections etc complete as required. a) 4 sq mm
2
-
-
b) 6 sq mm
2
-
-
c) 16 sq mm
6
-
-
d) 25 sq mm
6
-
-
e) 35 sq mm
6
-
-
f) 50 sq mm
6
-
-
g) 70 sq mm
6
-
-
h) 120 sq mm
3
-
-
i) 185 sq mm
3
-
-
j) 240 sq mm
3
-
-
k) 300 sq mm
3
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 25 sq. mm
2
-
-
b) 3½ X 50 sq. mm
2
-
-
c) 3½ X 95 sq. mm
1
-
-
d) 3½ X 185 sq. mm
1
-
-
e) 3½ X 240 sq. mm
1
-
-
f) 3½ X 300 sq. mm
1
-
-
Supplying and fixing following capacity ON Load type change over switch i/c making connections, testing etc complete as required. a) 32 Amp , 4 pole
2
-
-
b) 63 Amp 4 pole
2
-
-
c) 125 amp 4 pole
1
-
-
Supplying and fixing Sheet steel enclosure for following capacity ON Load type change over switch etc complete as required. a) 32 Amp , 4 pole
1
-
-
b) 63 Amp 4 pole
1
-
-
c) 125 amp 4 pole
1
-
-
Servicing of following size monoblock pump set/submersible i/c gressing, varnishing of pump set i/c replacement of bearing, making it free and operational , attending water leakage in the system if any, replacement of gland rope , checking and tightning of all priming arrangement , including removing the pump set, taking it to workshop, and again refixing the same , tesing etc complete as required. a) 1 HP up to 4 HP
2
-
-
b) 5 HP to 7.5 HP
1
-
-
Rewinding of following capacity Monoblock / submersible including removing the pump set, taking it to workshop, and again refixing the same , tesing etc complete as required. a)2 HP
1
-
-
b)3 HP
1
-
-
c)5 HP
1
-
-
d)7.5 HP
1
-
-
S/F following items in pumping system i/c fixing with all required hardware i/c testing,comm. Etc as required. a) 40/50 mm foot valve
1
-
-
b) 40/50 50 mm UPVC suction pipe
3
-
-
c)DOL starter (L & T)
1
-
-
Evaluation Notes How It Works ?