Bhabha Atomic Research Centre Tender
... More
The BARC has issued a formal invitation for competitive bids for the Bhabha Atomic Research Centre project, for CATEGORY: ANNUAL MAINTENANCE SERVICE - AUDIO CONFERENCING
SYSTEM - NON-COMPREHENSIVE ANNUAL MAINTENANCE
CONTRACT FOR PUBLIC ADDRESS SYSTEMS AT BARC SITE
MYSORE; VARIOUS MAKES; OEM Authorised Service Provider in Mysuru, Karnataka, with an estimated contract value of Rs. 4,50,000. The bid opening date for this tender is 28-04-2025 and the last date for bid submission is 02-06-2025. Interested bidders for Bhabha Atomic Research Centre tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2025/B/6178236Tender No
GEM/2025/B/6178236Tender Authority
Bhabha Atomic Research Centre ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
PA System No. PAS-3/11 as per item no. 3 of Annexure ….….. MAINTENANCE
1
-
-
... More
PA System No. PAS-5/15 as per item no. 5 of Annexure …..…. MAINTENANCE
1
-
-
... More
Attending Breakdown Maintenance of Public Address Systems at BARC Mysore on per day basis. Maintenance involves trouble-shooting of Public Address systems by skilled Bosch trained Service Engineer with Technician. (When No Authorized Laptop/Dongle/Software is required.) …......... BREAKDOWN MAINTENANCE
5
-
-
... More
Supply and Installation of Electrical grade ISI marked rigid heavy duty 2.0 mm thick 19 mm dia reputed make FRLS PVC conduits in Ivory/white color at a height of 4.0 metres above ground alongwith all types of accessories, viz., Junction boxes, wooden plugs, spacer saddles at regular intervals on RCC /brick wall surface/ MS fabricated surface. (All accessories are included in this item and will not be measured separately.) ................................................. SUPPLY
500
-
-
... More
PA System No. PAS-8/18A as per item no. 8 of Annexure ……. MAINTENANCE
1
-
-
... More
PA System No. PAS-9/ITMF as per item no. 9 of Annexure ….. MAINTENANCE
1
-
-
... More
PA System No. PAS-6/17 as per item no. 6 of Annexure …..…. MAINTENANCE
1
-
-
... More
PA System No. PAS-7/18 as per item no. 7 of Annexure ….….. MAINTENANCE
1
-
-
... More
PA System No. PAS-4/12 as per item no. 4 of Annexure ……... MAINTENANCE
1
-
-
... More
PA System No. PAS-2/8 as per item no. 2 of Annexure ………. MAINTENANCE
1
-
-
... More
PA System No. PAS-10/PCF as per item no. 10 of Annexure … MAINTENANCE
1
-
-
... More
PA System No. PAS-1/6 as per item no. 1 of Annexure ………. MAINTENANCE
1
-
-
... More
PA System No. PAS-13/AF3 as per item no. 13 of Annexure …. MAINTENANCE
1
-
-
... More
Attending Breakdown Maintenance of Public Address Systems at BARC site, Mysore on per visit (per call) basis. Maintenance involves trouble-shooting of Public Address systems by skilled Bosch trained Service Engineer with Technician Using Licensed software /Dongle. (Bosch authorised Laptop/Dongle/Software used to attend maintenance call.) ……........…. BREAKDOWN MAINTENANCE
1
-
-
... More
Installation of 2/4/5 Pair flexible Communication cables/LAN cables in the existing Metal /PVC conduit of 25 mm/19 mm size. Note: Flexible Communication cables/LAN cables will be issued as Free Issue Materials by the department. ………………………………................................….…........... INSTALLATION
500
-
-
... More
Preventive Maintenance of Public Address Systems as per the following and as per the Specific Technical Requirements enclosed herewith.
-
-
-
... More
Supply and Installation of Electrical grade ISI marked rigid heavy duty 2.0 mm thick 19 mm dia reputed make FRLS PVC conduits in Ivory/white color at a height of 4.0 metres above ground alongwith all types of accessories, viz., Junction boxes, wooden plugs, spacer saddles at regular intervals on RCC /brick wall surface/ MS fabricated surface. (All accessories are included in this item and will not be measured separately.) ..................................... INSTALLATION
500
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements