Bengaluru Water Supply And Sewerage Board Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bengaluru Water Supply And Sewerage Board - BWSSB Tender

Works
Water Storage And Supply
Opening Date26 Mar 2025
Closing Date9 Apr 2025
Tender Amount₹ 84,84,75,360.59 
Notes
Download

Costs

Summary

Work Of Providing Water Supply Feeder Main, Construction Of Ground Level Reservoirs, Over Head Tank

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn ordinary/soft rock without blasting upto 1.5 m depth

2864.3

390

1117735.789

... More
code05 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m to 3 m depth

2714.7

456

1240292.136

... More
code06 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.hard rock (blasting prohibited) Depth upto 1.50 m

1496.2

1090

1630932.81

... More
code07 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.hard rock (blasting prohibited) Depth exceeding 1.5 m, but not exceeding 3 m

1346.55

1204

1621246.2

... More
code08 - Excavation of Hard Rock by diamond rope cutting method using diamond rope,line draw machine,making holes by drilling machine for breaking the block by means of hydraulic breakers/splitters without any means of blasting or use of explosives,etc.,complete as per specification and directions of the Engineer-in-Charge.

1362.2

7733

10534641.81

... More
code09 - Filling available excavated earth (excluding rock) in trenches,plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

4465.4

285

1276881.13

... More
code10 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

24126.5

91

2204679.57

... More
code11 - Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.

73

2883

210469.95

... More
code12 - Providing Coursed rubble masonry (first sort) with hard stone infoundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

269.07

7114

1914258.1545

... More
code13 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates

1902.44

6711

12767712.4012

... More
code14 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse

201

6683

1343337.27

... More
code15 - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification includingspreading in uniform thickness, hand packing, rolling with vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. Using Screening Type B (11.2mm agg)

3390.34

2955

10019064.9612

... More
code16 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse

352

6758

2379002.56

... More
code17 - centering, shuttering and form work

365

675

246685.25

... More
code18 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including Formwork M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates .

5583.6

8913

49771652.04

... More
code19 - Providing and laying in position Reinforced cement concrete M30 Design Mix for vertical side walls, effluent channel baffle walls etc. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 20 mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality, labour,centering, scaffolding, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications.(Contractor will make his own arrangements for procuring water for testing). (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags).

3693.8

14343

52982869.874

... More
code20 - Providing and laying in position Reinforced cement concrete M30 Design Mix for columns below and above ground level. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags).

373.12

13322

4970883.7376

... More
code21 - Providing and laying in position Reinforced cement concrete M30 Design Mix for top cover flat slab. The Granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing in cement mortar 1:3, 12 mm thick for inside surface, labour,centering, scaffolding, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags))

2624.42

14440

37897884.5216

... More
code22 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification

1328

95505

126830839.2

... More
code23 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification

43.8

84936

3720233.154

... More
code24 - Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewe, effluent and water treatment plants, over head tanks, etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI - 212-3R-2010 ie. by reducing permeability of concrete by more than 90percentage compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats at 0.70 kg per sqm per coat

4798.7

465

2233698.876

... More
code25 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

14783.99

146

2161419.338

... More
code26 - Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts integral crystalline mortar : 1 parts water) for treatment of faulty construction joints, cracks, tie rod holes, spalled and honey combed surface, coves at junction joints of RCC structures like floor and walls of reservoirs, sewage, effluent and water treatment plants, over head tanks, etc. The crystalline mortar shall conform to EN 1504-3 having compressive strength class R4 greaterthan 45 MPa and adhesive bond strength class R3 greaterthan 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product

8760.7

516

4520521.2

... More
code27 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

4440.72

136

606291.5016

... More
code28 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications

1771.2

485

860626.08

... More
code29 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specification

46.08

964

44434.0224

... More
code30 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.

72

1258

90635.76

... More
code31 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete

8

1197

9580.4

... More
code32 - Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.

8

469

3758.24

... More
code33 - Providing and fixing 230 mm wide and minimum 5 mm thick continuous PVC waterstops of approved quality at contraction and expansion joints as per manufacturers instructions at all levels for Ground level reservoir.

4027.2

333

1342064.4

... More
code34 - Supplying and fixing PVC encapsulated CI rungs to shapes and at locations specified in drawings and specifications for Valve chambers

40

129

5160

... More
code35 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.

7061.8

878

6202237.704

... More
code36 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for flaging

180.32

7100

1280340.5216

... More
code37 - Providing and fixing 150mm dia. Cast Iron pipe for ventilatiing shaft 1m high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cementconcrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earthwork excavations and refilling in all strata, disposal of surplus earth etc.complete.

32

22668

725392.96

... More
code38 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.

384

1408

540768

... More
code39 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

768

380

292262.4

... More
code40 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

176

274

48246.88

... More
code41 - Providing and fixing 110 mm dia - 6g/cm2 PVC rain water pipes as per IS: 4984 including all fixtures such as brackets, bends etc.as directed by the Engineer.

432

411

177634.08

... More
code42 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

9150

607

5557527

... More
code43 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding

4000

180

722400

... More
code44 - Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing) Note: a) No Negative tolerance in respect of thickness is pemissible.b) Basic Cost of MS Plate is considered as Rs.68,200.00 per MT. The bare pipe cost worked out is Rs. 77.59/kg weight/m of pipe c) The pipe costs are FOR destination anywhere in Karnataka.Pipe of 355.6mm dia -9.5mm thick for Scoure pipe

234

10467

2449343.52

... More
code45 - Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing) Note: a) No Negative tolerance in respect of thickness is pemissible.b) Basic Cost of MS Plate is considered as Rs.68,200.00 per MT. The bare pipe cost worked out is Rs. 77.59/kg weight/m of pipe c) The pipe costs are FOR destination anywhere in Karnataka. 610 mm dia with 10 mm shell thickness Inlet/oulet Pipe of GLR& over flow

520

18832

9793123.6

... More
code46 - Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing) Note: a) No Negative tolerance in respect of thickness is pemissible.b) Basic Cost of MS Plate is considered as Rs.68,200.00 per MT. The bare pipe cost worked out is Rs. 77.59/kg weight/m of pipe c) The pipe costs are FOR destination anywhere in Karnataka. Pipe of 1016 mm dia-10 mm thick shell thickness Manifold Pipe of GLR

110

31814

3499609.3

... More
code47 - Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing) Note: a) No Negative tolerance in respect of thickness is pemissible.b) Basic Cost of MS Plate is considered as Rs.68,200.00 per MT. The bare pipe cost worked out is Rs. 77.59/kg weight/m of pipe c) The pipe costs are FOR destination anywhere in Karnataka. Pipe of 1219 mm dia-12.5 mm thick shell thickness Manifold Pipe of GLR

20

45945

918910

... More
code48 - Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8 mm thick such as bends, tail pieces, reduces etc. conforming to IS7322:1985 with latest amendments and including perfect linking and welding of joints to correct position including cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for testpressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minimum of 50 micron thick (after dry) and outside 25 mm thick coating in CM 1:3 by providing 50x50 mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The rates are inclusive of all taxes and duties. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make hiw own arrangements for procuring water for testing) for:-Pipe bends,branches, tail pieces, reducers etc. for above 500mm dia pipes

9500

166

1582985

... More
code49 - Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8 mm thick such as bends, tail pieces, reduces etc. conforming to IS7322:1985 with latest amendments and including perfect linking and welding of joints to correct position including cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for testpressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minimum of 50 micron thick (after dry) and outside 25 mm thick coating in CM 1:3 by providing 50x50 mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The rates are inclusive of all taxes and duties. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make hiw own arrangements for procuring water for testing) for:-Pipe bends,branches, tail pieces, reducers etc. upto 500mm dia pipes

14800

182

2704700

... More
code50 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-16:For Valve of PN - 16 and 600 mm for inlet

16

480961

7695383.2

... More
code51 - Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder or liquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed) 1000 mm dia PN 16

4

1045632

4182528.32

... More
code52 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For 300 mm dia. PN 16 size scour valves for GLR

8

75727

605818.4

... More
code53 - Supplying and fixing kinetic AIR VALVE PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside.For Air Valves of 150 mm dia.

7

42150

295055.25

... More
code54 - Providing and fixing guage with iron sheet of 3 mm to 4 mm thickness, 0.23 Mtr. Width with copper floats indicators and flexible nylon wires, painting figures with approved enamelled paint all lead and lifts etc, complete.0 to 6.5 Mtr depth

8

105350

842800

... More
code55 - Supply, delivery at site,fixing,testing and commissioing of Conductivity type Level Switch for the High Level & Low Level sensing - (2 point contact) with necessary instrumentation cabling,glands with suitable stub and flange and bolting arrangement for hook-up, as applicable and necessary. (0 - 10 m)

2

33996

67993.9

... More
code56 - Installation, Commissioning and Testing (for receipt of readings to the Bulk Flow Metering and Monitoring System SCADA Centre ) of HART output ( fl\ow rate and Totalizer) based Electromagnetic Induction Bulk Flow Meters approved make to the feeder mains . The fl ow meter shall be full bore type shall be installed as per Manufacturer Recommendations. The Electromagnetic Induction Bulk Flow meters shall comply with the specifi cations mentioned. The maximum allowable measuring error shall be plus/- 0.2 percentage of the volume. The meter transmitter shall convert the HART Output to produce reliable and correct output. The data to the remote server shall be transmitted with HART Protocol Remote Telemetry Device(RTU)..The Remote Telemetry Devices to Monitor the Real Time Water Flow and Totalizer b converting Output from Bulkflow meter (the Output is of HART output). The transmitter or the modem provided shall be of HART ( Highway Addressable Remote Transduser) type, which shall work in the master mode to read the totalizer and flow rate including panel box. The Remote Telemetry Devices shall have atleast the following specification.All data will be read via HART protocol and transmitted to the client Server via FTP Hardware:: Power: 12V DC, Connectivit: Builtin 3G with 2G fall back connectivity, Input HART: Builtin HART Modem in Master Mode to read fl ow rate and totalizer value, Digital inputs to connect to Door sensor and AC relays, One Relay output to switch on Light inside the enclosure, One MicroUSB port to configure the gateway, Customized sheet metal box, Operating Temperature: -10 to plus70 Deg C operating, High Gain GPRS Antennae. Software :: Linux based Operating System, Programmable via C and Node.js, ReAP Framework supporting HTTP and FTP, Option to configure 3 FTP Sites for data transfer, Option to configure 1 HTTP url for data transfer,automatic Upgradation of Firmware and Configuration Software via Over the Air. The cost includes all materials,accessories,labour complete. Battery Operated- 600mm dia

8

576349

4610795.44

... More
code57 - Design, fabrication, supply, erection, testing and commissioning EOT crane consisting of double girder box type construction, rail mounted end carraiges with long and cross travel arrangement, main and auxiliary hoists of specified capacity, rails, pendant control, gear boxes, electric motors, brakes, rope drums, wire ropes, sheaves, end buffer stoppers, pendant operated DSL bus bars with all accessories for main and auxiliary hoists for handling pumps and accessories in pump house including cost of all aterials,machinery, labour,cutting, aligning,welding, finishing, cleaning, greasing, applying two coats of zinc chromate red oxide primer and three coats of synthetic enamel paint etc., complete as perspecifications and approved drawings with all leads and lifts .

8

228007

1824060

... More
code58 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.

1260

1408

1774395

... More
code59 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and moving scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

1400

375

525252

... More
code60 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

1260

380

479493

... More
code61 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 ltr/10 m² over and including one coat of Special primer applied at 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

1400

169

237790

... More
code62 - Finishing walls with 100percentage Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of requiredshade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied at 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing thesurface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

1260

167

211302

... More
code63 - Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2(1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed at 2 litre per 50 kg of cement or as per direction of Engineer incharge.( including Skirting)

1000

860

860000

... More
code64 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge

1200

146

175440

... More
code65 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,mit red and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials,labour,usage charges of machinery complete as per specifications.

1080

485

524772

... More
code66 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.

60

984

59082

... More
code67 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.

544

497

270765.12

... More
code68 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.

32

1258

40282.56

... More
code69 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

48

2830

135863.04

... More
code70 - Providing and laying of 1.5 mm thick SBS modified self adhesive single stick waterproofing membrane, with minimum elongation of 300percentage and puncture resistance of greater than200 N (as per ASTM E154), with an overlap of 100mm on the side and 100mm in vertical lapping over a coat bituminuos primer at 0.25 l/m2,complete including surface preparation as per the methodology and site condition & placing the dimple board over the SBS membrane. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.

1344

818

1099499.52

... More
code71 - Providing and fixing RCC precast fencing pole of size 0.15mx0.15mx2.0m casted in M 20 with 20mm down size aggregates making holes for drawing barbed wire at 30 cm c/c using 8 mm dia vertical 4 TMT steel rods and 6 mm dia stirups at 15 cm c/c fixed 1.5 m above Ground level using steel moulding , curing , transportation to work spot including excavation in all types of soil, fixing in plain cement concrete M15 using 20 mm downsize aggregate including aligning to plumb and line providing including cost of all materials, labour,usage charges of machinery complete

600

1166

699828

... More
code72 - Providing and erecting in position, 2400 x 600 x 60 mm size precast slab panels of M25 grade design mix reinforced cement concrete with OP cement at 320 kgs/cum, 20mm and down size graded granite metal coarse aggregate, super plasticizer conforming to IS 9103-1999 reaffirmed 2008 at 3 ltr / cum, machine mixed, laid into fabricated steel form work, vibrated / compacted and cured for RCC precast slabs with groove finish, with logo of organisation and other side plain finish. The precast slabs to have reinforcements 1no. of 10mm dia. loop and round the panel, 5 Nos of 8mm dia. horizontals and 15 Nos of 8mm dia. verticals equally spaced.The thickness of panel shall be 60mm thick at the middle and 70mm thick at the edges for a width of 250mm. The gaps between the panels shall be packed with CM 1:4 and final surface between the panel and RCC post shall be finished using silicon sealant of approved make etc. The cost includes the cost of all materials, labour, HOM of machinery, casting yard, curing etc. complete as per specifications.

2160

1860

4019392.8

... More
code73 - Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire

6400

12

82560

... More
code74 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge

9344

121

1135109.12

... More
code75 - Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material

450

2673

1203084

... More
code76 - Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver/grader in sub base/ base course on well prepared surface and compacting with vibratory roller/ tamper/plate vibrator to achive the desired density. MORTH clause 406

540

2750

1485496.8

... More
code77 - Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 kg per m2 using mechanical means.

2400

44

105768

... More
code78 - Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom

2400

12

30960

... More
code79 - Providing and laying Dense Graded Bituminous Macadam with 100 TPH capacity HMP batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, at 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.

120

9343

1121268

... More
code80 - Providing and laying Bituminous Concrete with 100 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, at 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects

72

11327

815563.44

... More
code81 - Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 0 to 1.5m depth

120

321

38570.4

... More
code82 - Providing and laying in position plain cement concrete for levelling coursefor all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel Reinforcement shall be paidseparately) PCC 1:3:6 using 40 mm aggregate

960

6711

6442848

... More
code83 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

192

6811

1307750.4

... More
code84 - Form work at 35 percent

51

2383

121579.92

... More
code85 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications

192

285

54902.4

... More
code86 - Disposal off the excess excavated earth of all types by vehicle including loading,unloading with all lead and lifts, labour, HOM of machineries etc. for 4.0 to 5.0 Km

195

141

27670.5

... More
code87 - Supplying at site of work erection and commission of brand new Submerged VT Pumpset with integrally mounted on Bowl with enclosed impeller confirming to the latest IS standards Pump and Motor Mounted on a single shaft, fitted with Dual Mechanical shaft seals, Life Long greased bearings with L10h , the motor shall be of TEWC Induction type, Air Filled yet capable of Water Immersion upto 20mwc rated for S1 duty with winding should be of Class "F' or “H” insulation with IP 68 protection for Motor Casing 240 cu.m/hr capacity at 30 m. 1. Shut off head: Min 130percentage of the specified head.2.The pumps including working pumps and standby pumps shall be automatically operated in sequence such that no pump shall run continuously for longer duration. This shall be achieved through a control system.3. The duty condition of the pump should be to the left of the best efficiency point and closer to best efficiency point. 4. Minimum guaranteed efficiency of Submerged Pumpsets shall be 74percentage without negative tolerance. 6. The pump is required to work at an altitude of 800.0 m above MSL and at a maximum ambient temperature of 50 degree Centigrade.7. Single working pump should be able to deliver minimum of 5.76 MLD at the rated head.8. Submersible Motor shall be of Voltage - 415 plusor- 10percentage,Frequency - 50 plusor- 5percentage, Comined Variation plus or - 10percentage, Pump Monitoring Unit should be supplied alongwith the Pumps and the same shall be incorporated in the Control Panel. Pump casing: Cast Steel ASTM A 216 Gr.WCB & Motor Casing: Cast Iron: IS 210 Gr. FG 260, Impeller: Stainless Steel: ASTM A 743 CF8M, Shaft: Stainless Steel: BS 970 Gr. 410, Mechanical Seal: Primary seal Inboard of Silicon Carbide v/s Silicon Carbide & Secondary seal of Carbon v/s Cast Chrome Molybdenum Steel or Silicon Carbide or Tungsten Carbide,Suction Stainer:SS 304, Lifting Chain: SS 304, Bearing - Ball Bearings, Suspended Stand (Vertical): MS Fabricated Epoxy painted, Fasteners, Anchors bolts, Foundation Bolts etc. both in wet and dry areas: Stainless Steel : 316.

16

1303980

20863683.2

... More
code88 - Supply and fixing of Ductile Iron double flanged swing check valves with slanted seat or with lever weight with straight disc, with metallic corrosion proof and wear resistant seal faces with nickel overlay micro-finished with body and disc in Ductile Iron of minimum grade GGG-40, shaft of stainless steel and bearings of zinc free bronze and surfcae protection with epoxy liquid of GSK quality. 200 mm PN 1.6 on individual delivery side

16

60297

964765.28

... More
code89 - Supplying & Fixing of Motorised DI Resilient seated Non-rising spindle sluice valves as per IS 14846,Body,Bonnet in DI IS 1865 Gr.500/7 & wedge shall be fully EPDM rubber encapsulated on DI IS 1865 Gr.500/7,Spindle in SS 431/420,Fasteners in CS IS 1367 Cl 4.6/4.0.Flanges drilled to IS 1538 Table 4 & 6.The rate is inclusive of cost of valve,bolts & nuts and rubber insertions,excluding earthwork, mating flanges,bolts & Gaskets shall be inclusive 200 mm PN 1.6 on individual delivery side

16

241367

3861882.88

... More
code90 - Supplying & Fixing of DI Resilient seated soft sealing sluice valve with body,bonnet of Ductile Iron of grade GGG50,Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100percentage leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5.The stem sealing should be with toroldol sealings rings (Minimum 2 O rings). All the valves should be with Electro static powder coating both inside and outside with pocket less body passage. The rate is inclusive of cost of valve,T.P.set,bolts & nuts and rubber insertions,excluding earthwork (Note:Face to face dimensions shall be as per IS 14846-2000) 400 mm PN 1.6 for Common header pipe

16

179494

2871918.4

... More
code91 - Supply,installation,testing of SS 304 Expansion Bellows of Flange Ends with necessary mating flanges,bolts & Gaskets for Dismantling purpose 200 mm PN 1.6 on individual delivery side

32

6442

206169.6

... More
code92 - Supply,installation,testing of SS 304 Expansion Bellows of Flange Ends with necessary mating flanges,bolts & Gaskets for Dismantling purpose 200 mm PN 1.6 on individual delivery side 400 mm PN 1.6 for Common header pipe

12

16052

192628.8

... More
code93 - MS fabricated supports & chequered plates for pipeline,Ladder & I-girder for hoist,platforms for valve and pump operation & maintainence and other Equipments

9640

121

1171067.2

... More
code94 - Manufacturing, providing, transnporting, rolling, lowering, laying & Jointing, testing, commissioning of Spirally/Longitudinal welded MS pipes (Fe-410 grade) conforming to IS 3589-2001 including perfect linking,welding of joints and Flange Joints to correct position including cost and conveyance of pipes and materials with all lead and lifts, cost of all labour and giving satisfactory hydraulic test as per IS 3589 - 2001 for test pressure and working pressure both at factory and site etc., complete as per detailed specifications with Internal food grade epoxy coating 406 microns of approved make & External food grade epoxy coating 406 microns/Coal Tar Enamel Coating & Wrapping, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. The Rates are including rubber insertion or any equivalent to the required specifications with MS Bolts and nuts for Flange Joints complete (Contractor will make his own arrangement for procuring water for testing). The rates are inclusive of all taxes and duties.406 mm with 8.7 mm thk on Common delivery Header

120

11183

1341987.6

... More
code95 - Manufacturing, providing, transnporting, rolling, lowering, laying & Jointing, testing, commissioning of Spirally/Longitudinal welded MS pipes (Fe-410 grade) conforming to IS 3589-2001 including perfect linking,welding of joints and Flange Joints to correct position including cost and conveyance of pipes and materials with all lead and lifts, cost of all labour and giving satisfactory hydraulic test as per IS 3589 - 2001 for test pressure and working pressure both at factory and site etc., complete as per detailed specifications with Internal food grade epoxy coating 406 microns of approved make & External food grade epoxy coating 406 microns/Coal Tar Enamel Coating & Wrapping, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. The Rates are including rubber insertion or any equivalent to the required specifications with MS Bolts and nuts for Flange Joints complete (Contractor will make his own arrangement for procuring water for testing). The rates are inclusive of all taxes and duties.219.0 mm with 8.7 mm thk on individual delivery side of each pump

96

5977

573792

... More
code96 - Manufacturing, providing, transnporting, rolling, lowering, laying & Jointing, testing, commissioning of Spirally/Longitudinal welded MS pipes (Fe-410 grade) conforming to IS 3589-2001 including perfect linking,welding of joints and Flange Joints to correct position including cost and conveyance of pipes and materials with all lead and lifts, cost of all labour and giving satisfactory hydraulic test as per IS 3589 - 2001 for test pressure and working pressure both at factory and site etc., complete as per detailed specifications with Internal food grade epoxy coating 406 microns of approved make & External food grade epoxy coating 406 microns/Coal Tar Enamel Coating & Wrapping, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. The Rates are including rubber insertion or any equivalent to the required specifications with MS Bolts and nuts for Flange Joints complete (Contractor will make his own arrangement for procuring water for testing). The rates are inclusive of all taxes and duties.219 mm dia- 7.9 mm thick ( Scour Valve)

72

5557

400158

... More
code97 - Supplying & Fixing of DI Resilient seated soft sealing sluice valve with body,bonnet of Ductile Iron of grade GGG50,Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100percentage leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5.The stem sealing should be with toroldol sealings rings (Minimum 2 O rings). All the valves should be with Electro static powder coating both inside and outside with pocket less body passage. The rate is inclusive of cost of valve,T.P.set,bolts & nuts and rubber insertions,excluding earthwork (Note:Face to face dimensions shall be as per IS 14846-2000) 200 mm PN 1.6 on Common header for Scour Valve

4

35513

142054.8

... More
code98 - Supplying & Fixing of DI Resilient seated soft sealing sluice valve with body,bonnet of Ductile Iron of grade GGG50,Wedge fully rubber lined with EPDM & seals of NBR and the valves should be vaccum tight and 100percentage leak proof with face dimensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4/F5.The stem sealing should be with toroldol sealings rings (Minimum 2 O rings). All the valves should be with Electro static powder coating both inside and outside with pocket less body passage. The rate is inclusive of cost of valve,T.P.set,bolts & nuts and rubber insertions,excluding earthwork (Note:Face to face dimensions shall be as per IS 14846-2000) 100 mm PN 1.6 on Common header for Kinetic Air relief valve isolation arrangement

4

13390

53560.8

... More
code99 - Supplying and fixing kinetic AIR VALVE PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside.100 mm PN 1.6 on Pumping main for Air release valve arrangement

4

29680

118723

... More
code100 - Supply,Installation and commissioning of Chain Pulley Block with Trolley arrangement as per IS 3938 of 2 Ton Capacity with a height/lift of 10 m for lifting and lowering of Pumps from GLR and lowering to the FGL during maintenance.

4

48594

194376

... More
code101 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300 mm)

16

3191

51066.88

... More
code102 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.

16

760

12160.48

... More
code103 - Supplying of MS Bolts, nuts and Washers for all the Flange joints for all above listed locations

2000

170

340000

... More
code104 - Supplying of Champion gaskets (Rubber Insertions) for all the Flange joints for all above listed locations (3 Ply RI Sheet)

2000

87

174000

... More
code105 - DAS Specification Compact RMU (VCB/SF6 Type)as per IEC-62271 4 Way RMU, 2OD plus 2VL (One Incomer plus Two Breakers plus One Outgoing) 630 Amps with Copper Busbar

4

1185232

4740930.6

... More
code106 - Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work- For RMU Foundation Size - 3200L x 1900W x 800Depth mm

19.46

233

4539.6288

... More
code107 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Bed Concreting with CC 1:2:4- RMU

3.99

6711

26777.8875

... More
code108 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking,aping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationProviding Reinforcement Steel for -RMU foundation

0.24

84936

20384.8392

... More
code109 - Providing and constructing granite/trap/basalt size stone masonry in foundtaio with cement mortar 1:6 edges of stones chistle dressed in courses not less than 15 cm high, bond stones at 2 Mtr apart in each course including cost of materials, labour curing complete as per specifications

1.96

7114

13944.126

... More
code110 - Providing and constructing granite/trap/basalt size stone masonry in foundtaio with cement mortar 1:6 edges of stones chistle dressed in courses not less than 15 cm high, bond stones at 2 Mtr apart in each course including cost of materials, labour curing complete as per specifications

8.53

6031

51451.5099

... More
code111 - Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc.,

4

810

3242.2

... More
code112 - Rod type earthing with 40 mm Dia, 3 Mtr long MS rod as per specification & drawing with Bentonite clay slurry

8

2334

18679.2

... More
code113 - Labour charges for Fixing foundation frame of MS channel 100x50 mm and MS angle 40 x 40 x 5 mm welding, fixing in concrete, aligning the RMU on foundation bed, assembly of units, connecting Bus Bars from panel to panel etc., complete.

16

25105

401688.8

... More
code114 - 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)

1.2

1022312

1226774.52

... More
code115 - Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work Cable trench Size - 1000W X 1400Depth mm-

1680

279

469560

... More
code116 - Supply of Artificial Sand/Manufacture Sand -Cable Trench

300

1599

479880

... More
code117 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications

1440

172

247680

... More
code118 - Heat Shrinkable Indoor Type CableTermination Kit for XLPE Cable 3x95 Sqmm

16

6882

110114.4

... More
code119 - Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95Sqmm

16

7229

115670.08

... More
code120 - Heat Shrinkable Straight Through Jointing Kit for XLPE Cable with Copper Lug & Al Ferrule 3x95 Sqmm

48

10920

524204.64

... More
code121 - RCC Hume Pipe 2000 mm long 150 mm Dia

48

384

18472.8

... More
code122 - Collars for RCC Hume Pipe,150 mm Dia

48

150

7224

... More
code123 - Double pole structure for 100/300 kVA 4/5 Star Rated Transformer on RCC Pole - 9 Mtr Long, 145 Kg WL - GI

4

39406

157625.12

... More
code124 - 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod)

12

246

2956.92

... More
code125 - 11 kV GOS - Double Break 400 A

4

24159

96638.2

... More
code126 - 9kV, 5KA Lightning Arrester, Metal Oxide,

12

1658

19898.52

... More
code127 - Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr

24

555

13338.72

... More
code128 - 5 Star rated Aluminium Wound Distribution Transformer - 3 Phase, 11kV/433V - Amorphous Core with Oil as per IS-1180 (Part-1): Cable Entry Box Type 250 KVA

4

552111

2208445.6

... More
code129 - 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod)

48

271

13055.04

... More
code130 - Rabbit ACSR Conductor (6/3.35 mm Al plus 1/3.35 mm St), Std Wt: 214 Kg/KM as per IS-398

200

55327

11065404

... More
code131 - GI Wire 8 SWG

20

80

1613.2

... More
code132 - Guy Wire 7/10SWG

40

83

3320.8

... More
code133 - GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg including Good Quality well burnt Charcoal and salt

12

2642

31708.2

... More
code134 - LT Distribution box for 250kva with MCCB

4

26308

105233.92

... More
code135 - LT Electronic Tri-Vector Meter 5A, Class- 0.5/1.0 accuracy

4

3816

15265

... More
code136 - 11kV Lightning Arrester, Metal Oxide, 9kV, 5kA Polymeric Type with ground disconnector

4

1962

7851.8

... More
code137 - PVC Insulation tapes in rolls of 10mtr

8

16

129.04

... More
code138 - Anti Climbing Device (12mtr/Kg GI Barbed Wire) Lumpsum

8

130

1040.64

... More
code139 - Rod type earthing with 40 mm Dia, 3 Mtr long MS rod as per specification & drawing

32

2421

77503.36

... More
code140 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)

2

962064

1924129.6

... More
code141 - Supply and fixing of fully Enclosed Automatic Transfer Switch(ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources.The enclosure made of MS Power coated of necessary size.The switch comprising of EB/DG-Priority Source selection,.AdjustableTime lay(0.1secto3hours),.Double-Break Contact System offering HighShort-time Withstand(Icw),.with necessaryTerminal Shrouds,Phase Barriers & Source Separator,.Protections for UV/OV,Phase Sequence,Single Phasing,Frequency variation.There should be sufficient space for cable termination.Three Phase 415 V250 KVA

4

115951

463806.6

... More
code142 - Supply and fixing of fully Enclosed Automatic Transfer Switch(ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources.The enclosure made of MS Power coated of necessary size.The switch comprising of EB/DG-Priority Source Selection,.AdjustableTime Delay(0.1secto3hours),.Double-Break Contact System offering HighShort-time Withstand(Icw),.with necessaryTerminal Shrouds,Phase Barriers & Source Separator,.Protections for UV/OV,Phase Sequence,Single Phasing,Frequency variation.There should be sufficient space for cable termination.415 V main switch board as per specification

4

2697197

10788790.32

... More
code143 - 110 V, 15 A float and 30 A boost (with float and boost battery charger as per technical specification).

4

182105

728420

... More
code144 - BATTERY SET 110 V, 200 AH

1

652322

652322.9

... More
code145 - AC Distribution Box Single front (Outdoor type) 6 Terminal one I/C of 100A MCCB 20kA plus 6 O/GMCB 16A plus 1 O/G of 100A, HRC fuse, complete as per technical specification.

8

48451

387610.64

... More
code146 - Rod type earthing with 40 mm Dia, 3 Mtr long MS rod as per specification & drawing

8

2421

19375.84

... More
code147 - 1.1 kV Class Armoured Aluminium Cable withgla nds/lugs/ferrules : 4C x 95 Sq mm

1600

852

1364208

... More
code148 - COPPER CONTROL CABLE : 4C x 25 Sq mm

1600

953

1525456

... More
code149 - COPPER CONTROL CABLE : 4C x 4 Sq mm

4000

212

850920

... More
code150 - COPPER CONTROL CABLE : 4C x 2.5 Sq mm

4000

175

700440

... More
code151 - Copper PVC Instrumentation Cable, Armoured (Screened Cable) Copper Cable with glands/lugs/ferrules : 8P x 0.5 Sq mm

2000

164

328720

... More
code152 - Fibre Optics Distribution Panel 24F : Indoor type consisting of 1 no. of rack mounted LIU (to be housed in FODP) with 24 ports each with FCPC coupling & pigtails

4

53361

213447.72

... More
code153 - Fiber to Ethernet Media Converter :10/100/1000 Mbps

8

5203

41624

... More
code154 - Industrial Grade PC with latest specification

8

106141

849129.6

... More
code155 - HMI Monitor : 29 inch

8

26535

212282.4

... More
code156 - 2 kVA Online UPS (230 V AC, 1 phase, 50 Hz)UPS with Battery confirming to KPTCL specification

4

180804

723217

... More
code157 - DG Set :3 Ph, 50 Hz, 415 V, 0.8 pf, 250 kVA capacity Diesel Generator set mounted on box frame complete withinbuilt fuel tank and battery 2 nos. 24 V and inbuilt standard manual control panel with accoustic enclosure : NAL approved D.G. set 250 kVA capacity with AMF panel as per technical specification

4

2235599

8942396.12

... More
code158 - Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.7 m - Top 70 mm and Bottom 130 mm dia

24

15503

372087.6

... More
code159 - Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single Arm Bracket with 1500mm Standard 40/50MM dia

24

2257

54180

... More
code160 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598,LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75.LED Streetlight 70 W

24

6441

154593.6

... More
code161 - Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work. For Street Light Size 450mm Dia X 2000mm Depth

11.4

278

3174.102

... More
code162 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) at 75percentage & GGBS at 25percentage proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge.RMC M25 For Street Light

7.82

6685

52280.0626

... More
code163 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking,aping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationProviding Reinforcement Steel For Street Light

0.64

84936

54359.5712

... More
code164 - Rod type of earthing using 40mm dia, 3mtr long MS rod as ground rod, in earth pit of 300mm width and 3300mm depth and using 50x6mm flat welded to ground rod as terminal & connected to equipment ground terminal using pvc Al wire

24

2421

58127.52

... More
code165 - Sub division:Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using Dozer a) In area of light jungle

2407

4

10157.54

... More
code166 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth

187.5

102

19149.375

... More
code167 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

161.25

260

41949.1875

... More
code168 - In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 m

116.01

278

32300.6643

... More
code169 - Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting Depth upto 1.5 m depth

48.38

321

15550.7834

... More
code170 - In ordinary/soft rock without blasting upto 1.5 m-3 m depth

46.4

478

22196.832

... More
code171 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. / Lindane 20percentage E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

284.59

126

36100.2415

... More
code172 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm and down size graded crushed coarse aggregates

65.24

6088

397233.312

... More
code173 - Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

34.82

6811

237165.984

... More
code174 - Extra for Additionalties for Formwork, centering and scaffolding For Foundation upto plinth - a) Isolated

23.48

544

12794.252

... More
code175 - Extra for Additionalties for Formwork, centering and scaffolding For RCC Columns /Shaft

8.86

4767

42243.0624

... More
code176 - Extra for Additionalties for Formwork, centering and scaffolding For RCC Roof slabs

1.88

3405

6402.528

... More
code177 - Extra for Additionalties for Formwork, centering and scaffolding For staircase footings

0.6

3405

2043.36

... More
code178 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

72.79

7356

535459.9817

... More
code179 - Extra for Additionalties for Formwork, centering and scaffolding for RCC Beams, Lintels & Troughs of Aqueducts

27.64

4413

121995.7736

... More
code180 - Extra for Additionalties for Formwork, centering and scaffolding for RCC Roof Slabs

34.82

3678

128071.7902

... More
code181 - Extra for Additionalties for Formwork, centering and scaffolding for RCC Columns / Shaft (Slip Centering)

7.7

5149

39650.072

... More
code182 - Extra for Additionalties for Formwork, centering and scaffolding For Staircase and other similar structures

2.63

3678

9673.4293

... More
code183 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

1.33

7127

9479.2425

... More
code184 - Extra for Additionalties for Formwork, centering and scaffolding Chejjas, Canopy & Other Architectural projections of minor sections

1.33

3207

4265.6558

... More
code185 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.For Buildings

13.27

96166

1276126.5356

... More
code186 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

88.81

6868

609963.0658

... More
code187 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m..

153.63

285

43930.4985

... More
code188 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.

509.97

1408

718165.2525

... More
code189 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.

41.58

1186

49347.144

... More
code190 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps),but including cost of materials, labour, usage charges complete as per specifications.

0.37

148429

54918.9335

... More
code191 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification -do- 35 mm thick both side Teak

11.97

4871

58316.643

... More
code192 - Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

6

129

774

... More
code193 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

2

1197

2395.1

... More
code194 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

2

1130

2261.8

... More
code195 - Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.

6

1064

6385.5

... More
code196 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete

10

254

2547.8

... More
code197 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete

10

139

1397.5

... More
code198 - Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms

10

59

591.3

... More
code199 - Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete.

30

63

1902.9

... More
code200 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.

1.89

4813

9098.1765

... More
code201 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to bepaid separately) 30 mm thickness

9.45

3746

35403.291

... More
code202 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm

37.2

821

30552.36

... More
code203 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.

589.68

180

106496.208

... More
code204 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

265.44

607

161222.9472

... More
code205 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing completeas per specifications and as per directions of Engineer-in-charge.

476.24

413

197106.2112

... More
code206 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

675.72

393

265862.034

... More
code207 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding of corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

261.53

347

90811.0619

... More
code208 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

118.85

393

46761.5325

... More
code209 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer incharge

937.25

107

100754.375

... More
code210 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percentage and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm

233.96

1230

287976.6848

... More
code211 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge .Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.

41.39

2605

107860.2705

... More
code212 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.

27.34

1156

31624.178

... More
code213 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.

60.73

1557

94597.9064

... More
code214 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge

476.24

187

89080.692

... More
code215 - Finishing walls with 100percentage Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

937.25

167

157176.825

... More
code216 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, abour complete as per specifications and as per directions of Engineer-in-charge.

23.94

56

1364.1012

... More
code217 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge

23.94

148

3551.499

... More
code218 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

59.94

149

8956.8342

... More
code219 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification

400.05

878

351355.914

... More
code220 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size- 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)

24.18

7239

175040.229

... More
code221 - Providing and fixing storage unit of 0.60m Depth made out of 19mm thick commercial ply vertical support finished in approved 1.0mm laminate with 12mm thick ply packing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade colour and 19mm thick shutters formed out of 19mm thick ply finished 1.00mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification.

66

12074

796910.4

... More
code222 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipeshaving thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 meter spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete (concealed work including cutting chases and good the walls etc.) 20 mm nominal dia Pipes

100

407

40743

... More
code223 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 meter spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete (concealed work including cutting chases and good the walls etc.) 25 mm nominal OD Pipes .

100

512

51278

... More
code224 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 meter spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete (concealed work including cutting chases and good the walls etc.) 32 mm nominal OD Pipes,

200

598

119756

... More
code225 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore

7

318

2227.4

... More
code226 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore

7

356

2498.3

... More
code227 - Providing and fixing in position brass bib cock of approved quality 20mm nominal bore

7

327

2295.16

... More
code228 - Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete

6

236

1419

... More
code229 - Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore

5

97

489.15

... More
code230 - Providing and placing on terrace (at all floor levels) polyethylene water storage tanks IS 12701 marked with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

1000

9

9680

... More
code231 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid

5

6425

32126.4

... More
code232 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern

3

4788

14364.15

... More
code233 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

4

2520

10083.52

... More
code234 - Providing pedestal for wash basin of approved 1st quality and make conforming to ISI specifications and fixing for low down cistern as directed. Rate includes cost of materials and conveyance to work spot.

4

1529

6118.92

... More
code235 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External workand making good the same including testing of joints complete (concealed work including cutting chases and good the walls etc.) 65 mm nominal OD Pipes.

50

1505

75250

... More
code236 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.

6.91

2168

14982.8148

... More
code237 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and efective height of 88 mm, weighing not less than 170 g.

3

513

1541.55

... More
code238 - Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete.1200 mmx1250 mm

1

10259

10259.8

... More
code239 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc complete For PVC pipes 75mm dia., 6 kg/sqcm & class 3

50

236

11825

... More
code240 - For PVC pipes 110mm dia., 6 kg/sqcm & class 3

50

441

22091.5

... More
code241 - For PVC pipes 160mm dia., 6 kg/sqcm & class 3

50

664

33217.5

... More
code242 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover,

6

5150

30901.98

... More
code243 - Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete.1200 mmx1250 mm

1

10259

10259.8

... More
code244 - Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick

150

70

10642.5

... More
code245 - 25 mm dia 2 mm thick

350

83

29347.5

... More
code246 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick

150

73

10965

... More
code247 - 25mm dia 2mm thick

300

84

25479

... More
code248 - Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box

20

60

1204

... More
code249 - 19/20 mm deep Junction box

20

52

1053.6

... More
code250 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 1-2 Way

15

110

1660.95

... More
code251 - b)4-5Way

10

147

1472.8

... More
code252 - c)6Way

8

185

1487.84

... More
code253 - d)8Way

14

235

3296.02

... More
code254 - e)10-12Way

7

280

1964.06

... More
code255 - Point wiring using copper wire Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Short point upto 3Mtr from tapping point to out let via switch

10

306

3063.8

... More
code256 - b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch

20

423

8471

... More
code257 - c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch

80

612

49020

... More
code258 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module

15

147

2209.2

... More
code259 - 4 module

10

188

1881.3

... More
code260 - 6 module

8

251

2012.4

... More
code261 - 8 module

14

305

4274.2

... More
code262 - 10-12 module

7

369

2588.6

... More
code263 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

70

109

7675.5

... More
code264 - b) 6 Amps two way.

6

178

1070.7

... More
code265 - c) Stepped Fan Regulator Two Module

6

383

2302.68

... More
code266 - d) 16 Amps one way switch

15

193

2902.5

... More
code267 - e) 6 Amps 3way socket.

25

183

4595.75

... More
code268 - f) 32 Amps DP switch

6

350

2102.7

... More
code269 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm

75

37

2822.25

... More
code270 - Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm

25

23

591.25

... More
code271 - Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell

2

264

528.9

... More
code272 - Supplying and fixing of round or oblong type bulk head fitting glass cover

10

75

752.5

... More
code273 - Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 36/40 W

19

1364

25919.42

... More
code274 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearingsystem. 48" Sweep (1200 mm) Regular model

6

3207

19246.8

... More
code275 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)

4

3191

12766.72

... More
code276 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders

12

131

1573.8

... More
code277 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

8

183

1470.64

... More
code278 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

4

528

2115.6

... More
code279 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP

10

446

4461.3

... More
code280 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG

50000

-

27000

... More
code281 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm

2

596

1193.26

... More
code282 - 50 x 100 x 50 x 6 mm C channel

2

812

1625.4

... More
code283 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

3

3773

11319.75

... More
code284 - GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 6 mm GI strip

120

137

16512

... More
code285 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)

0.2

401206

80241.226

... More
code286 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-1.5 mm2

750

27

20962.5

... More
code287 - 2.5 mm2

600

45

27090

... More
code288 - 4 mm2

400

67

27092

... More
code289 - 6mm2

60

98

5934

... More
code290 - Supplying and installation of 1Hp monoblock submersible pump along with auto level controller to pump water from Sump to OHT

1

18296

18296.5

... More
code291 - Chlorination unit: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m

1200

109

131580

... More
code292 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately).

49.6

6438

319333.728

... More
code293 - Filling available excavated earth (excluding rock) in sides of foundations upto plinth in layers not exceeding 20cms. In depth, compacting each deposited layer by ramming after watering with a lead upto 50m and lift upto 1.5m including cost of all labour complete as per specifications.

400

285

114380

... More
code294 - Disposing off the excess Excavated Earth of all types upto distance mentioned below by vehicle including loading,unloading, with all lifts,labour,HOM of machinary etc. complete 4.0 to 5.0 Km

800

132

105600

... More
code295 - Providing and laying in position plain cement concrete of mix 1:3:6 using 20mm and downsize graded granite metal machine mixed, concrete laid in layers not exceeding 15 cms thick, well compacted, in foundation and plinth including cost of all materials, labour, HOM of machinery curing complete as per specifications.

25.2

6683

168418.656

... More
code296 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

67.2

6811

457712.64

... More
code297 - For Form work at 8percentage for Foundation

67.2

544

36616.608

... More
code298 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

27.72

6811

188806.464

... More
code299 - Form work for columns and piers at70percentage

27.72

4767

132164.5248

... More
code300 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

70.461

6811

479923.9632

... More
code301 - Beams & Lintels of Building and Roof (Straight & Arched) at60percentage

70.461

4086

287954.37792

... More
code302 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

54

6758

364960.62

... More
code303 - form work and Roof (Straight & Arched) at50percentage

54

3379

182482.2

... More
code304 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification

12.44

96166

1196307.9012

... More
code305 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.

947.59

1408

1334443.6175

... More
code306 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and moving scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

1581.68

317

501598.1784

... More
code307 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

366.38

380

139425.909

... More
code308 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 ltr/10 m² over and including one coat of Special primer applied at 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

1550.28

169

263315.058

... More
code309 - Finishing walls with 100percentage Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied at 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing thesurface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

344.58

167

57786.066

... More
code310 - Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2(1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed at 2 litre per 50 kg of cement or as per direction of Engineer incharge.( including Skirting)

180

860

154800

... More
code311 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.

891.001

625

557454.77565

... More
code312 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.

59.4006

1258

74775.257298

... More
code313 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

24

2830

67931.52

... More
code314 - Providing and laying of 1.5 mm thick SBS modified self adhesive single stick waterproofing membrane, with minimum elongation of 300percentage and puncture resistance of greaterthan200 N (as per ASTM E154), with an overlap of 100mm on the side and 100mm in vertical lapping over a coat bituminuos primer at 0.25 l/m2,complete including surface preparation as per the methodology and site condition & placing the dimple board over the SBS membrane. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.

198.9899

818

162787.667493

... More
code315 - Design, fabrication, supply, erection and commissioning of structural steel hoist supporting structure consisting of columns, cross beams, bracings, stiffeners, mono-rail with fixtures with all accessories for electrically operated monorail rope drum hoist for operating pump house intake vertical lift gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, applying two coats of zinc chromate red oxide primer and three coats of synthetic enamel paint and all other ancillary operations complete as per specifications and approved drawings. Note: 1. Columns with bracings / anchors / stiffeners: 150 kg per metre height. Weight proposed above is for each intake vent 2. Mono rail beam with cross beams : 100 kg per metre length3. Quantity of structural steel = 97.8 percentage of computed weight for 1 span.

3.5

146415

512452.5

... More
code316 - Water and Sanitary Works Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually Controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floorswherever required W.C. pan with ISI marked white solid plastic seat and lid

2

5200

10401.7

... More
code317 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 40x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern

2

3801

7602.4

... More
code318 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps

2

3313

6626.3

... More
code319 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

2

1311

2623

... More
code320 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

2

533

1066.38

... More
code321 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

4

682

2730.52

... More
code322 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

6

620

3721.68

... More
code323 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)25 mm nominal bore

2

779

1558.76

... More
code324 - Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk forfixing CI cover & frame etc. excluding the cost of CI frame and cover.

6

5150

30901.98

... More
code325 - Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 15mm dia

60

212

12771

... More
code326 - Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if anyFor 15 mm dia GI BEND

30

106

3192.9

... More
code327 - Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if anyFor 15 mm dia GI TEE

20

65

1311.6

... More
code328 - Providing and hoisting to the position and fixing polyethelene plastic water storage tank of 1000 litres of approved make with mosquito proof jali frame and cover 450mm dia. with locking arrangement, including copper ball cock with brass arm including washout plug, overflow GI pipe etc., complete. with lead and lift.

4

8975

35900.08

... More
code329 - Supply,Testing, Installation & Commissioing of 5 Kg/hr Capacity with 0-2 ppm dosage level Vaccum type Chlorination System (Includes FRP Floor mounted chlorinator cabinet (Cabinet,Differential Pressure regulator, Secondray Check valve, Drain valve, Remote vaccum regulator, Ejector Assembly with check valve, Chlorine flow meter (Rotameter)Chlorine rate control valve,flexible vent & vaccum tubing,Yoke clamp for reuglator mounting), Electrical Auto-change over device,Gauges & Instruments, Gas filters, Diffuser piping, Chlorine gas piping and valves assembly, motive water system (supply tapping from outletpipe of GLR) ,Service water system for Chlorine house (Eye wash and shower & other mislleaneous works) and office use,Safety equipments,Emergency Kit,Tonner lifting beam,load indicator, Instrumentation system,testing and monitoring devices,Platform weighing scale and 4 nos. of Chlorine tonners with chlorine gas filled along with Horizontal centrifugal Pump with motor 2 nos. (1w plus1s) for Booster water supply,(Safety Equipment - Air Breathing Apparatus, Canister Type Gas Mask, Spare canister, Chlorine Leak Detector with single sensor, Protective clothing, Emergency Repair Kit - B, Safety shower and eye wash, Residual Chlorine Test Kit, Instant action resuscitator, Ammonia Torch)

2

1610250

3220500

... More
code330 - Supply,Testing, Installation & Commissioing of chlorine leak absorption system with FRP frontal hood for 2 nos. of chlorine tonners, 200OD PVC Ducting as per site condition,blower with motor set (1000 m3/hr at200 mwc)-2 Nos., Pressure gauge with isolation valve on blower outlet-2 sets,Motorised Damper on suction side-2 Nos., Manual Damper on suction side-2 Nos., PP-FRP caustic recirculation tank (8 m3) empty-1 No., level gauge on tank-1 No., Dissolving basket-1 No., level switch on tank-1No., 50 NB PP diaphragm valve for drain and water inlet-2 Nos., PP tower with packing -1 No., 80 NB valve for pump suction-3 Nos., 80 NB strainer for pump suction-2 Nos.,90 OD PVC pipe on caustic pump suction of required length as per site condition, caustic recirculation pump with motor-2 Nos., 65 NB PP diaphragm valve on caustic pump delivery-4 Nos., 65 NB check valve on caustic pump delivery-2 Nos., 75 OD PVC pipe with fitting on caustic pump delivery as per site condition, pressure gauge with isolation valve-2 Nos. with HOM equipments and with all lead and lift.

2

2203500

4407000

... More
code331 - Supply, delivery and installation of chlorine cylinder of 100 Kg capacity as per IS 3196(Part-4):2001 (with chlorine filled) including explosive certificate including cost of all fittings, specials,other materials,labour,for commissioing of the work

2

18360

36720

... More
code332 - Supplying of 1440rpm heavy duty exhaust fan with bracketblades suitable to operate on 230V 50Hz, AC Supply complete15" Sweep (450 mm)Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame

4

5481

21925.8

... More
code333 - Supplying and installing 0 - 2500 kg capacity weighing machine including cost of all fittings, specials,other materials,labour,for commissioing of the work

2

35000

70000

... More
code334 - Supplying,Laying,jointing,testing and commissioning of GI pipes conforming to IS 1239:1990 with latest ammendments including fixing collars,elbows,tees,gland cocks and other fittings (Including cost of specials) with cuts and threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead & lift (contractor will make his own arrangements for procuring water for testing) 32 mm dia GI pipe - Heavy Duty (Suction & delivery piping)

80

324

25979.2

... More
code335 - Feeder main: Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Means Bituminous course

790

346

273458.5

... More
code336 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the for All Kinds of soil and as per the specifications and as dirctetions by the Engineer- in -Charge-Up to 1.5m depth

11981.9

208

2498825.245

... More
code337 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the for All Kinds of soil and as per the specifications and as dirctetions by the Engineer- in -from 1.5 m to 3 m depth

10118.359

264

2675800.03755

... More
code338 - Earth work excavation for pipeline trenches in soft rock by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the for Ordinary/soft rock (without requiring blasting) and as per the specifications and as dirctetions by the Engineer- in -Charge Up to 1.5m depth

1577.199

367

579857.21235

... More
code339 - Earth work excavation for pipeline trenches in soft rock by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the for Ordinary/soft rock (without requiring blasting) and as per the specifications and as dirctetions by the Engineer- in -Charge-Up to 3 m depth

1367.3

452

618812.634

... More
code340 - Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work hard rock (blasting prohibited) Depth upto 1.50 m

788.599

829

654458.3101

... More
code341 - Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work hard rock (blasting prohibited) Depth exceeding 1.5 m, but not exceeding 3 m

683.7

916

626939.226

... More
code342 - Excavation of Hard Rock by diamond rope cutting method using diamond rope,line draw machine,making holes by drilling machine for breaking the block by means of hydraulic breakers/splitters without any means of blasting or use of explosives,etc.,complete as per specification and directions of the Engineer-in-Charge.

1165.6

7733

9014225.88

... More
code343 - Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with: Murrum/Gravel

2160

392

847540.8

... More
code344 - Supplying and filling in trenches with sand/ Stone dust / m-sand including watering, ramming, consolidating and dressingcomplete.

5550

2574

14287365

... More
code345 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

11534.8

91

1054050.024

... More
code346 - Manufacturing, providing, trasporting, rolling, lowering, laying,jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing). 1219mm dia 12.5mm thick

3000

45945

137836500

... More
code347 - Manufacturing, providing, trasporting, rolling, lowering, laying,jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing). 914mm dia 10mm thick

150

28585

4287799.5

... More
code348 - Providing and laying Ductile Iron pipes of class conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining ( CML ) of DI pipes, if High Alumina Cement ( HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement ( SRC ), the cost of pipes may be increased by 5-6percentage from the prices listedFor DI K9 Pipes:300mm dia pipe

500

5146

2573015

... More
code349 - Providing and laying Ductile Iron pipes of class conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining ( CML ) of DI pipes, if High Alumina Cement ( HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement ( SRC ), the cost of pipes may be increased by 5-6percentage from the prices listedFor DI K9 Pipes:400mm dia pipe

1000

7869

7869000

... More
code350 - Providing and laying Ductile Iron pipes of class conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining ( CML ) of DI pipes, if High Alumina Cement ( HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement ( SRC ), the cost of pipes may be increased by 5-6percentage from the prices listedFor DI K9 Pipes:150mm dia pipe

150

2548

382324.5

... More
code351 - Providing and installing sheet piling for both sides of the trenches for following depths with mild steel sheets of not less than 6.5mm thick, stronger knife edge, recessed spreader sockets, 3 inch single or double wall shields, to be designed by the contractor to withstand all types of soils, maximum depth as per the approved design drawings, including labour charges for installing and removiing the sheet piling at variousreaches of sewer line constructions, including loading, unloading,transporting to the suitable location etc. complete with all lead and lifts. (Measurement shall be taken for one side only eventhough it is provided for both sides).

300

626

188019

... More
code352 - Supply and fixing of Cast steel ASTM A 216 Gr.WCB double flanged Dualplate check valve Conforming to API 594 with latest amendments Shaft material shall be SS420/431 and spring shall be spring steel superior grade quality as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking with appurtenances., complete with all lead and lift. The rates are inclusive of cost of Galvanised Bolts and Nuts: For class 150 etc. complete PN 1.6- 1200mm

1

1089104

1089104

... More
code353 - Providing and fixing of Double Flanged Resilient seated short body Butterfly valves of various dis. As per IS 13095/en 593 with integral DI seat face with approved soft sealing with body and disc of Ductile Iron (DI) of grade GGG-40/50, Body seat & Seal retaining ring of SS 304/CF8, Shaft of stainless steel AISI 410/420/431, Bronze shaft bearing, periferal disk, seal end O rings of EPDM, double eccentric disk. Body and disk should be coated with electrostatcially applied epoxy powder coating with a coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, TP set, galvanised bolts and nuts and rubber insertions. For PN 10.0 (All the drilled holes in the body shall be of through holes, no tapped holes will be allowed.) (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete For Valve of PN 16.0 and 800mm

1

313483

313483.98

... More
code354 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-16: etc. complete6: 300mm dia for Scour

2

75727

151454.6

... More
code355 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 O rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-16: etc. complete6: 400mm dia

2

146073

292146.3

... More
code356 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 O rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-16: etc. complete6: 150mm dia for Scour

2

22736

45472.5

... More
code357 - Manufacturing, providing, trasporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with Each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing for:Above 500 mm dia Pipes

22184.1

166

3696536.583

... More
code358 - Manufacturing, providing, trasporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with Each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing for:upto 500mm dia pipes

1109.21

182

202708.1275

... More
code359 - Providing and fixing kinetic AIR VALVE of PN 16.0 for automatic discharge.of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside etc. complete-100mm Dia

8

29680

237446

... More
code360 - Supplying and fixing of DI specials with ISI mark confoming to IS 9523 / 2000 suitable for jointing 100 mm to 600 mm dia DI pipes coated with rust prevention coatings as below:NOTE: A) External coating: a) Metalic zinc with finishing layer of bituminous as per Annexure A of IS:9523/2000 b. Zinc rich paint with finishing layer of bituminous as per Annexure Aof IS:9523 / 2000 c) Bituminous paint as per Annexure “C” of IS:9523 / 2000 B) Internal Lining: a) Portaland Cement (with or without additives) mortar as per Annexure - B of IS:9523/2000 b) Cement Mortar with coat coat as per Annexure B of IS:9523 / 2000 c) Bituminous paint as per Annexure “C” of IS:9523 / 2000

1147.4

199

229422.63

... More
code361 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) and as per the specifications and as dircted by the Engineer- in -Charge

23.21

6183

143516.714

... More
code362 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) and as per the specifications and as dircted by the Engineer- in -Charge

396.63

6725

2667416.076

... More
code363 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification

31.73

96166

3051356.0644

... More
code364 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. and as per the specifications and as dircted by the Engineer- in -Charge.

9747.22

131

1278347.903

... More
code365 - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401

1580

2673

4224177.4

... More
code366 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

1925

2750

5295540.25

... More
code367 - Prime Coat over WMM/WBM. Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg per m2 using mechanical means.

7900

44

348232

... More
code368 - Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom

7900

12

101910

... More
code369 - Providing and laying Dense Graded Bituminous Macadam with 100 TPH capacity HMP batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, at 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.

464

9343

4335569.6

... More
code370 - Providing and laying Bituminous Concrete with 100 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, at 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects

237

11327

2684565.36

... More
code371 - Installation, Commissioning and Testing (for receipt of readings to the Bulk Flow Metering and Monitoring System SCADA Centre ) of HART output ( flow rate and Totalizer) based Electromagnetic Induction Bulk Flow Meters approved make to the feeder mains . The flow meter shall be full bore type shall be installed as per Manufacturer Recommendations. The Electromagnetic Induction Bulk Flow meters shall comply with the specifications mentioned. The maximum allowable measuring error shall be plus/- 0.2 percent of the volume. The meter transmitter shall convert the HART Output to produce reliable and correct output. The data to the remote server shall be transmitted with HART Protocol Remote Telemetry Device(RTU)..The Remote Telemetry Devices to Monitor the Real Time Water Flow and Totalizer by converting Output from Bulkflow meter (the Output is of HART output). The transmitter or the modem provided shall be of HART (Highway Addressable Remote ransduser) type, which shall work in the master mode to read the totalizer and flow rate including panel box. The Remote Telemetry Devices shall have atleast the following specification.All data will be read via HART protocol and transmitted to the client Server via FTP Hardware- Power: 12V DC, Connectivity: Builtin 3G with 2G fall back connectivity, Input HART: Builtin HART Modem in Master Mode to read flow rate and totalizer value, Digital inputs to connect to Door sensor and AC relays, One Relay output to switch on Light inside the enclosure, One MicroUSB port to configure the gateway, Customized sheet metal box, Operating Temperature: -10 to plus70 Deg C operating, High Gain GPRS Antennae. Software-Linux based Operating System, Programmable via C and Node.js, ReAP Frameworksupporting HTTP and FTP, Option to configure 3 FTP Sites for data transfer, Option to configure 1 HTTP url for data transfer, Automatic Upgradation of Firmware and Configuration Software via Over the Air. The cost includes all materials,accessories,labour complete. Battery Operated-1200mm dia

1

1976400

1976400

... More
code372 - Installation, Commissioning and Testing (for receipt of readings to the Bulk Flow Metering and m onitoring System SCADA Centre ) of HART output ( flow rate and Totalizer) based magnetic Induction BulkFlow Meters approved make to the feeder mains . The flow meter shall be full bore type shall be installed as per Manufacturer Recommendations. The lectromagnetic Induction Bulk Flow meters shall comply with the specifications mentioned. The maximum allowable measuring error shall be plus/- 0.2 percentage of the volume. The meter transmitter shall convert the HART Output to produce reliable and correct output. The data to the remote server shall be transmitted with HART Protocol Remote Telemetry Device(RTU).The Remote Telemetry Devices to Monitor the Real Time Water Flow and Totalizer by converting Output from Bulkflow meter (the Output is of HART output). The transmitter or the modem provided shall be of HART ( Highway Addressable Remote Transduser) type, which shall work in the master mode to read the totalizer and flow rate including panel box. The Remote Telemetry Devices shall have atleast the following specification.All data will be read via HART protocol and transmitted to the client Server via FTP Hardware-Power: 12V DC, Connectivity: Builtin 3G with 2G fall back connectivity, Input HART: Builtin HART Modem in Master Mode to read flow rate and totalizer value, Digital inputs to connect to Door sensor and AC relays, One Relay outputto switch on Light inside the enclosure, One MicroUSB port to configure the gateway, Customized sheet metal box, Operating Temperature: -10 to plus70 Deg C operating, High Gain GPRS Antennae. Software-Linux based Operating System, Programmable via C and Node.js, ReAP Frameworksupporting HTTP and FTP, Option to configure 3 FTP Sites for datatransfer, Option to configure 1 HTTP url for data transfer, Automatic Upgradation of Firmware and Configuration Software via Over the Air. The cost includes all aterials,accessories,labour complete. BatteryOperated FOR 400mm

1

414772

414772.63

... More
code373 - OHT- 1.5 Ml-2 Nos and 1 ML-1 No.Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

2110

199

421894.5

... More
code374 - Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

1156

213

247303.08

... More
code375 - Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth

422

321

135643.46

... More
code376 - Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting Depth exceeding 1.5m, but not exceeding 3 m

231.2

478

110601.456

... More
code377 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.hard rock (blasting prohibited) Depth upto 1.50 m

211

1090

230000.55

... More
code378 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.hard rock (blasting prohibited) Depth exceeding 1.5 m, but not exceeding 3 m

115.6

1204

139182.4

... More
code379 - Excavation of Hard Rock by diamond rope cutting method using diamond rope,line draw machine,making holes by drilling machine for breaking the block by means of hydraulic breakers/splitters without any meansof blasting or use of explosives,etc.,complete as per specification and directions of the Engineer-in-Charge

163.3

7733

1262888.715

... More
code380 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

1485

285

424635.75

... More
code381 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications

1485

178

264998.25

... More
code382 - Providing and laying in position plain cement concrete for levelling coursefor all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel Reinforcement shall be paidseparately) PCC 1:3:6 using 40 mm aggregate

93

6172

574056.45

... More
code383 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, strutting, plywood / steel form work , Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement to be paid separately) (Minimum cement content: 340 kgs (6.80 bags).RCC M25 Design Mix with 20mm aggregate

719

8913

6409094.1

... More
code384 - Providing and laying in position Reinforced cement concrete for columns,braces and ring beam above ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materialsof quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags). RCC M30 Design Mix with 20mm aggregate for level upto 6 m height.

354

13250

4690659.3

... More
code385 - Providing and laying in position Reinforced cement concrete for columns,braces and ring beam above ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materialsof quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags) RCC M30 Design Mix with 20mm aggregate for level 6m to 9m height

186

14760

2745514.38

... More
code386 - Providing and laying in position Reinforced cement concrete for columns,braces and ring beam above ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materialsof quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags) RCC M30 Design Mix with 20mm aggregate for level 9m to 12m height.

186

16308

3033442.38

... More
code387 - Providing and laying in position Reinforced cement concrete for columns,braces and ring beam above ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materialsof quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)RCC M30 Design Mix with 20mm aggregate for level 12m to 15m height.

79

17894

1413661.55

... More
code388 - Providing and laying in position Reinforced cement concrete for shell portion, bottom dome / slab and ribs over the staging. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cementmortar 1:3, 12 mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisiteproportion of approved quality, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specific tions.(Contractor will make his own arrangementsfor procuring water for testing). (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20bags). M30 Design Mix with 20mm aggregate for level and 12 to 15 m heigh

626

25529

15981216.6

... More
code389 - Providing and laying in position Reinforced cement concrete for side walls of water tank over the staging above the ground level. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cementmortar 1:3, 12 mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications.(Contractor will make his own arrangements for procuring water for testing). (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)). RCC M30 Design Mix with 20mm aggregate for level and upto 12-15 m height.

323

27019

8727153.15

... More
code390 - Providing and laying in position Reinforced cement concrete for top slab of water tank over the staging above the ground level. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing in cement mortar 1:3, 12 mm thick for both inside and outside surface, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags))

272

20898

5684256

... More
code391 - Supplying of TMT steel reinforcement for RCC work (Fe 500) 250kg/m3 of concrete

411.75

84936

34972739.7525

... More
code392 - Providing two coats of water proof cement painting with approved colour and shade over one coat of primer including necessary scaffolding and scrapping of old paint and stain with wire brushes and cleaning of paint stains etc. wherever necessary for old RCC over head tanks with all lead and lifts etc. complete for:Tanks upto 6 m staging.

1418

156

222555.1

... More
code393 - Providing two coats of water proof cement painting with approved colour and shade over one coat of primer including necessary scaffolding and scrapping of old paint and stain with wire brushes and cleaning of paint stains etc. wherever necessary for old RCC over head tanks with all lead and lifts etc. complete for: Above 6m to 9m staging

1214

176

214028.2

... More
code394 - Providing two coats of water proof cement painting with approved colour and shade over one coat of primer including necessary scaffolding and scrapping of old paint and stain with wire brushes and cleaning of paint stains etc. wherever necessary for old RCC over head tanks with all lead and lifts etc. complete for: Above 9m to 12m staging

1214

198

241440.32

... More
code395 - Providing two coats of water proof cement painting with approved colour and shade over one coat of primer including necessary scaffolding and scrapping of old paint and stain with wire brushes and cleaning of paint stains etc. wherever necessary for old RCC over head tanks with all lead and lifts etc. complete for: Above 12m to 15m staging

4200

222

934626

... More
code396 - Providing and fixing M.S. ladder between landing 45 cms. wide using angle iron of size 65 mm x 65 mm x 8 mm and 20 mm M.S. bars at 25cms. centre to centre with necessary supports of same angle iron as directed including hand railing on both sides with 25mm dia G.I. pipes with angle iron props at 2 mtrs, interval and 0.5 mtr, height including fixing in ground with C.C. 1:2:4 and two coats of anticorrosive bituminous paint with all lead and lift etc., complete.

102

4705

479938.56

... More
code397 - Providing and fixing R.C.C. finial and ventialators as per approved design and specification with form work and protected with wire mesh. The plinth to be of R.C.C. circular pillars and canopy with an ornamental finish at top. The first 22.50 Cms. height to be covered with RCC panelling as per detailed drawing with all lead and lift and excluding reinforcement steel. For tank upto 2.50lakh litres capacity.

3

11608

34826.79

... More
code398 - Providing and fixing M.S. Inspection door of size 60 cms x 60 cms. including M.S. frame, size 50 x 50 x 6 mm and shutters of 3mm thickness with hinges at top and locking arrangements painting with all lead and lift etc.

3

2300

6901.5

... More
code399 - Providing and fixing Enamelled guage with iron sheet of 3 mm to 4 mm thickness, 0.23 Mtr. width with copper floats indicators and flexible nylon wires, painting figures with approved enamelled gauge plate with all lead and lift etc., complete for 4.25M heightMS Guage sheet for 2.5 Mtrs depth

3

8144

24434.22

... More
code400 - Providing and fixing lightening arrestor of aluminum strip 25 mm x 3 mm size including finial and grounding aluminum strip is to be embedded in one of the columns in an independent GI conduit of 40 mm dia pipe suitably jointed by collars with all specials with all lead and lifts etc., complete.for tanks above 12 mtrs upto 15 mtrs staging.

3

14930

44792.04

... More
code401 - Supplying & Fixing CI puddle flanges confirming to IS 7181-1986 with latest amendments in position for R.C.C. walls including hoisting and conveying them to work spot with all lead and lift etc., complete. 200mm Dia

6

3449

20698.08

... More
code402 - Supplying & Fixing CI puddle flanges confirming to IS 7181-1986 with latest amendments in position for R.C.C. walls including hoisting and conveying them to work spot with all lead and lift etc., complete. 250mm Dia

3

4848

14544.75

... More
code403 - Supplying & Fixing CI puddle flanges confirming to IS 7181-1986 with latest amendments in position for R.C.C. walls including hoisting and conveying them to work spot with all lead and lift etc., complete. 300mm Dia

9

6107

54963.72

... More
code404 - Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. 200mm Dia

108

7086

765331.2

... More
code405 - Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. 250mm Dia

54

9967

538239.6

... More
code406 - Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. 300mm Dia

210

12709

2669043.3

... More
code407 - Suppling Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 200mm Dia

6

9406

56437.5

... More
code408 - Suppling Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 250mm Dia

3

14802

44408.25

... More
code409 - Suppling Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 300mm Dia

9

19694

177246

... More
code410 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings minimum 2 “ O “ rings). Body and bonut should be coated with electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: 200mm Dia

3

30862

92586.54

... More
code411 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings minimum 2 “ O “ rings). Body and bonut should be coated with electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: 250mm Dia

3

49977

149933.49

... More
code412 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings minimum 2 “ O “ rings). Body and bonut should be coated with electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: 300mm Dia

3

64849

194548.14

... More
code413 - Supplying & fixing 40 mm dia G.I. medium duty pipes hand railing 3 rows fixed to 1:2:4 (M-150) vibrated R.C.C. post of size 100 x 150 mm at top and 150 x 150 mm at bottom placed at 2 Mtr. intervals for a height of 750 mm including curing, painting G.I. pipes with two coats of anticorrosive steel paint over a primer coat with all lead and lift etc., complete.

455.16

1426

649299.3948



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.