Bengaluru Water Supply And Sewerage Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bengaluru Water Supply And Sewerage Board - BWSSB Tender

Civil And Construction
Opening Date18 Sep 2024
Closing Date25 Sep 2024
Tender Amount₹ 58,41,856.79 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and laying Ductile Iron pipes of class conforming to IS 8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials excluding cost of specials and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. the contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately Note In sewerage projects for internal cement mortal lining CML of DI pipes, if High Alumina Cement HAC as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement SRC, the cost of pipes may be increased by 5-6 percentage from the prices listed. For DI K9 pipes 100mm dia K9

780

1671

1303380

... More
code05 - 200mm dia K7

572

2551

1459172

... More
code06 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete 200mm dia

2

28709

57418

... More
code07 - 100mm dia Sluice valve

5

10884

54420

... More
code08 - Providing Ductile Iron Push on special confirming to IS 9523:2000 - All Socketed D.I. Un-Equal Tees 200 X 100

3

4867

14601

... More
code09 - Providing Ductile Iron Push on special confirming to IS 9523:2000 All Socketed D.I. Un-Equal Tees 250 X 200

1

7978

7978

... More
code10 - Providing Ductile Iron Push on special confirming to IS 9523:2000 All Socketed D.I. Equal Tees 100 x 100 X 100

3

2499

7497

... More
code11 - Providing Ductile Iron Push on special confirming to IS 9523:2000 200 mm dia 90 degree bends

3

12980

38940

... More
code12 - 200mm dia 45 degree bends

1

9387

9387

... More
code13 - 200 mm dia 22.5 degree bends

1

7641

7641

... More
code14 - 100mm diameter 22.5 degree

3

3294

9882

... More
code15 - 100mm diameter 90 degree

5

4087

20435

... More
code16 - 100mm dia 45 degree bends

3

3685

11055

... More
code17 - Supplying and fixing DI MJ specials Providing Ductile Iron Push on special confirming to IS 9523:2000 - All D.I. Flanged MJ COLLAR: DI MJ specials - collar 100 mm dia.

18

1231

22158

... More
code18 - DI MJ specials - collar 200 mm dia.

8

3171

25368

... More
code19 - Providing, fabricating and fixing at site various diameter MS MJ ends with dummy plates (END CAPS) to suit CI / DI spigots end as per the sketch. The cost is inclusive of all materials, i.e, rubber 'O' rings, flanges, bolts and nuts, dummy plates, consumables, hire charges, tools and welding equipments, lead and lifts, etc. complete as per the instructions of Engineer in charge. 100mm dia

6

1158

6948

... More
code20 - Manufacturing, providing, trasporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with Each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing for: Note: 1) For small works where the C.M. lining is not practicable for inside surface of the pipe, food grade expoxy painting of two coat over one coat of epoxy primer may be proposed and got approved. The above rates are applicable only for Pipe bends,branches, tail pieces, reducers etc. for upto 500mm dia pipes pipe works etc. complete

684.65

170

116390.5

... More
code21 - Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and Providing and laying of MDPE pipe (PE80)-PN 12.5 manufactured in accordance with ISO 4427-1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm/ GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. "A" class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making "U" shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on the distribution main pipe with SS / Brass ferrule of size 1/2" x 3/4" and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS). The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles, PE 100 black colour pipe of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter cum flow regulator, water tight cap with O'ring, long spigot for making bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for drinking water service in WRC - NSF, UK and DVGW certificate, Germany. The Saddle should be manufactured Virgin Compounded PE 100 material. Tapping Tee or Saddles with coupler and compression fittings with cost of GI pipes, as per diagram, all specials such as GI tee, GI elbow, GI coupler, stopper with appurtenances, and brass or SS tap The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed offto a distance with an initial lead of 10 Kms. etc. complete for the following diameters: (for minimum length of 2m) etc. complete for 15mm dia

95

6547

621965

... More
code22 - For connection pipe length beyond 2.0 mtrs for every 1 mtr. or part thereof

30

945

28350

... More
code23 - Removal of unserviceable soil with disposal upto a suitable distance as directed by the Engineer incharge of work. for:

145.77

85

12390.45

... More
code24 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications

563.11

160

90097.6

... More
code25 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density

169.52

2559

433801.68

... More
code26 - Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg per m2 using mechanical means.

798

41

32718

... More
code27 - Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction complete in all respects & as per specification.

39.9

7536

300686.4

... More
code28 - Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2on the prepared bituminous surface cleaned with mechanicalbroom

798

12

9576

... More
code29 - Providing and laying Bituminous Concrete with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.2 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respect

39.9

10705

427129.5

... More
code30 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.

11.09

6630

73526.7

... More
code31 - Installation, Commissioning and Testing (for receipt of readings to the Bulk Flow Metering and Monitoring System SCADA Centre ) of HART output ( flow rate and Totalizer) based Electromagnetic Induction Bulk Flow Meters approved make to the feeder mains . The flow meter shall be full bore type shall be installed as per Manufacturer Recommendations. The Electromagnetic Induction Bulk Flow meters shall comply with the specifications mentioned. The maximum allowable measuring error shall be +/- 0.2 % of the volume. The meter transmitter shall convert the HART Output to produce reliable and correct output. The data to the remote server shall be transmitted with HART Protocol Remote Telemetry Device(RTU)..The Remote Telemetry Devices to Monitor the Real Time Water Flow and Totalizer by converting Output from Bulkflow meter (the Output is of HART output). The transmitter or the modem provided shall be of HART ( Highway Addressable Remote Transduser) type, which shall work in the master mode to read the totalizer and flow rate including panel box. The Remote Telemetry Devices shall have atleast the following specification.All data will be read via HART protocol and transmitted to the client Server via FTP Hardware:: Power: 12V DC, Connectivity: Builtin 3G with 2G fall back connectivity, Input HART: Builtin HART Modem in Master Mode to read flow rate and totalizer value, Digital inputs to connect to Door sensor and AC relays, One Relay output to switch on Light inside the enclosure, One MicroUSB port to configure the gateway, Customized sheet metal box, Operating Temperature: -10 to+70 Deg C operating, High Gain GPRS Antennae. Software :: Linux based Operating System, Programmable via C and Node.js, ReAP Framework supporting HTTP and FTP, Option to configure 3 FTP Sites for data transfer, Option to configure 1 HTTP url for data transfer, Automatic Upgradation of Firmware and Configuration Software via Over the Air. The cost includes all materials,accessories,labour complete. Battery Operated 200 mm dia

1

248746

248746



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.