Bengaluru Metropolitan Transport Corporation Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bengaluru Metropolitan Transport Corporation - BMTC Tender

Works
Electrical and Electronics
Electrical Works
Opening Date14 Nov 2024
Closing Date21 Nov 2024
Tender Amount₹ 1,27,11,761.6 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20 mm 1.9.1

30

20

627

... More
code05 - Do- 25 mm 1.9.2

50

24

1210

... More
code06 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box 2.2.1

4

295

1183.6

... More
code07 - Do- Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 2.2.2

4

416

1667.6

... More
code08 - Do- Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box 2.2.3

4

610

2442

... More
code09 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2 2.3.2

1000

28

28600

... More
code10 - Do- 2.5 mm2 2.3.3

1500

46

69300

... More
code11 - Do- 4 mm2 2.3.4

500

69

34650

... More
code12 - Do- 6 mm2 2.3.5

50

101

5060

... More
code13 - Do- 10 mm2 2.3.6

20

183

3674

... More
code14 - Do- 16 mm2 2.3.7

10

349

3498

... More
code15 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS- 694:1990. 3C x 4 mm2 2.6.2

350

184

64680

... More
code16 - Providing Submersible Pump Set of 100 / 150 mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 7.50 HP 76 stage 7.5 HP 16 stage 13.15.7 = 40810.00 For additional 60 stages based on impeller rates add 18000/-

1

76453

76453

... More
code17 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. HDPE Grade PE80-PN16.0, 63mm dia (9.5.1) Rate =327.00 - For 50mm dia based on circumference multiplication factor is 0.79365...Rate = 259.52

350

337

118083

... More
code18 - Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm 13.25.1

1

1375

1375

... More
code19 - Labour charges for Erection, Electrification and commissioning of Pumpsets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. 13.32

1

8450

8450

... More
code20 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way 3.3.1

10

113

1133

... More
code21 - Do- 3 Way 3.3.2

5

136

682

... More
code22 - Do- 4-5 Way 3.3.3

5

150

753.5

... More
code23 - Do- 6 Way 3.3.4

10

190

1903

... More
code24 - Do- 8 Way 3.3.5

40

240

9636

... More
code25 - Do- 10-12 Way 3.3.6

20

287

5742

... More
code26 - Do- 18 Way 3.3.8

10

372

3729

... More
code27 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module 3.5.1

10

150

1507

... More
code28 - Do- 3 Module 3.5.2

5

177

885.5

... More
code29 - Do- 4 Module 3.5.3

5

192

962.5

... More
code30 - Do- 6 Module 3.5.4

10

257

2574

... More
code31 - Do- 8 Module 3.5.5

40

312

12496

... More
code32 - Do- 10-12 Module 3.5.6

20

378

7568

... More
code33 - Do- 18 Module 3.5.8

10

502

5027

... More
code34 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch 3.6.1

100

112

11220

... More
code35 - Do- 6A Two Way Switch 3.6.2

10

182

1826

... More
code36 - Do- 6A Three Way socket 3.6.3

70

188

13167

... More
code37 - Do- Stepped Fan Regulator Two Module 3.6.4

10

392

3927

... More
code38 - Do- 6A Bell Push 3.6.8

10

194

1947

... More
code39 - Do- 32A DP Switch 3.6.9

10

358

3586

... More
code40 - Do- 6/16A Universal Socket 3.6.10

10

259

2596

... More
code41 - Do- TV/Telephone Socket 3.6.11

20

171

3432

... More
code42 - Do- RJ45/I.O Outlet Cat-6 3.6.12

150

370

55605

... More
code43 - Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor. 5.2.1

4

8200

32802

... More
code44 - Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. 5.47

6

2546

15279

... More
code45 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 250 A 5.12.5

2

23963

47927

... More
code46 - Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A 5.13.1

18

1419

25542

... More
code47 - Do- 40 A 5.13.2

12

2483

29805.6

... More
code48 - Do- 60 A 5.13.3

6

6545

39270

... More
code49 - Do- 100 A 5.13.4

2

9927

19855

... More
code50 - Do- 200 A 5.13.7

1

22013

22013.2

... More
code51 - Do- 400 A 5.13.11

1

54376

54376.3

... More
code52 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 100 A 25 kA 5.15.1

17

6694

113808.2

... More
code53 - 200 A 25kA 5.15.4

6

15988

95931

... More
code54 - 400 A 50 kA 5.15.8

2

27608

55217.8

... More
code55 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole100 A 25 kA 5.15.9

14

9335

130699.8

... More
code56 - 250 A 36 kA 5.15.15

2

25899

51799

... More
code57 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT 5.16

41

1873

76805.3

... More
code58 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP 5.18.1

50

456

22825

... More
code59 - Do- 6-32 A DP 5.18.4

40

812

32516

... More
code60 - Do- 6-32 A TPN 5.18.7

20

1888

37774

... More
code61 - Do- 40 A TPN 5.18.8

12

3348

40180.8

... More
code62 - Do- 50-63 A TPN 5.18.9

8

3396

27174.4

... More
code63 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & N 5.19.8

4

2039

8157.6

... More
code64 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 4 Way TP & N 5.19.11

4

4441

17767.2

... More
code65 - 6 Way TP & N 5.19.12

2

5434

10868

... More
code66 - 8 Way TP & N 5.19.13

2

6700

13400.2

... More
code67 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. 5.21

2

10180

20361

... More
code68 - Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter 5.29

8

1567

12540

... More
code69 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. 5.38

40

566

22660

... More
code70 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. 5.30

10

1518

15180

... More
code71 - Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. 5.31

10

4829

48290

... More
code72 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy 5.33

8

10246

81972

... More
code73 - Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. 5.34

30

618

18546

... More
code74 - Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs

1

23804

23804

... More
code75 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips 5.40.1

2

2711

5423

... More
code76 - Do- 250 A 4 x 30 x 10 mm Aluminium Strips 5.40.2

1

3778

3778.5

... More
code77 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm 5.41.1

10

335

3355

... More
code78 - Do- 50 x 100 x 50 x 6 mm C channel 5.41.4

5

831

4158

... More
code79 - Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG 5.42.1

20000

-

10400

... More
code80 - Do- 16 SWG

200000

-

88000

... More
code81 - Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 5.51.4

1

115324

115324

... More
code82 - Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., 5.53

20

1463

29260

... More
code83 - Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. 5.37

30

528

15840

... More
code84 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 6.1

4

1641

6564.8

... More
code85 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300 mm) 6.2.1

20

3265

65318

... More
code86 - Do- 15" Sweep (450 mm) 6.2.2

6

4890

29343.6

... More
code87 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. 13.14

30

541

16236

... More
code88 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model 6.3.1

10

3282

32824

... More
code89 - Supplying wall mounting / Pedestal fan suitable to operate at single- phase 230v AC. supply. 400 mm Sweep 6.5.2

20

3533

70664

... More
code90 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. 13.10

30

188

5643

... More
code91 - Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 1.5 Ton capacity 6.8.5

4

61990

247962

... More
code92 - Do- 2 Ton capacity 6.8.6

6

74138

444833.4

... More
code93 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. 6.12

10

3492

34925

... More
code94 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. Split 6.13.1

60

1703

102234

... More
code95 - Supplying installation testing and commissioning of heavy duty compressor suitable for window/split type A/C. 1.5 Ton 6.14.2

2

16272

32544.6

... More
code96 - Do- 2 Ton 6.14.3

4

19825

79301.2

... More
code97 - Supply and fixing of condensing coil for Split Air Conditioners. 2 Ton 6.15.3

4

12757

51031.2

... More
code98 - Supplying and fixing capacitor's (of approved make) for window /split air conditioners. 80 to 200mfd starting capacitor. 6.16.2

20

5

100

... More
code99 - 25 to 45mfd running capacitor. 6.16.1

20

885

17710

... More
code100 - 80 to 200mfd starting capacitor. 6.16.2

20

1042

20856

... More
code101 - Supplying & fixing relay for over load protection for window and split air conditioners. 6.17

20

723

14476

... More
code102 - Supplying and fixing the fan motor for blowers and condenser of 1/5 HP, single shaft/double shaft suitable for split / window air conditioners. 6.18

10

6727

67276

... More
code103 - Supplying & filling refrigerant (F-22/F/12) for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. 6.19

80

665

53240

... More
code104 - Supplying & fixing of thermostat for window type air conditioner. Multi range 30 to 60 degree Centigrade (without probe), adjustable universal type 6.20

12

1249

14995.2

... More
code105 - Supplying and fixing electro mechanical / Pneumatic time switches. 6.21

12

1608

19298.4

... More
code106 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.

10

5287

52877

... More
code107 - Supply and fixing of out door condensing unit complete with condensing coil, blower, fan etc., complete suitable for Split Air Conditioners. 1.5 Ton 6.23.2

2

30879

61758.4

... More
code108 - 2 Ton 6.23.3

4

34827

139308.4

... More
code109 - Supplying & filling refrigerant latest R-410 / R-32 for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. 6.31

60

636

38214

... More
code110 - Supplying and commisioning of AC Remote 6.33

10

2256

22561

... More
code111 - Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 4kVA Capacity 9.1.2

10

5271

52712

... More
code112 - Supplying and drawing UTP-CAT 6E LAN cable. 8.1

1800

41

75240

... More
code113 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair 8.2.2

500

23

11550

... More
code114 - Supplying & Fixing of switch mounting rack with power manager Cable manager. 42U with 650mm depth 8.4.10

4

47484

189939.2

... More
code115 - Supplying & Fixing of switch mounting rack with power manager Cable manager. 42U with 800mm depth 8.4.11

4

49721

198884.4

... More
code116 - Supplying fixing of Network Switches 48 Port Gigabyte (manageable) 8.9.1

4

53779

215116

... More
code117 - 48 port 10/100/1000 Switch 8.9.9

4

22330

89320

... More
code118 - 24 port 10/100/1000 Switch 8.9.10

6

8156

48939

... More
code119 - 16 port 10/100/1000 Switch 8.9.11

6

7084

42504

... More
code120 - 8 port 10/100/1000 Switch 8.9.12

8

3410

27280

... More
code121 - Supplying & Fixing of ... ms Cat 6 Patch Cable 1 m. 8.11.1

100

246

24640

... More
code122 - Do- 2 m 8.11.2

40

282

11308

... More
code123 - Supplying & Fixing of Patch panel for LAN cabling 48 Port 10/100/1000 patch panel 8.12.4

6

26400

158400

... More
code124 - Do- 24 Port 10/100/1000 patch panel 8.12.5

6

8690

52140

... More
code125 - Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W 11.3.2

22

759

16698

... More
code126 - Do- LED light fitting 1 x 4' - 36/40 W 11.3.3

300

1395

418770

... More
code127 - LED Down light: Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should lesser than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W 11.4. 2

150

1395

209385

... More
code128 - Do- 15-18W

50

1838

91905

... More
code129 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x1' 24W. 11.6.2

50

4061

203060

... More
code130 - LED modular down light 2'x2' 36 W 11.6.3

150

5008

751245

... More
code131 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders 13.7.1

722

134

96892.4

... More
code132 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under conditions. LED Streetlight LED Streetlight 70W 11.8.4

30

6591

197736

... More
code133 - Do- LED Streetlight 90 W 11.8.4

22

9746

214412

... More
code134 - Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe. 13.1.2

4

1149

4598

... More
code135 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 100W 11.9.2

20

10434

208692

... More
code136 - Do- LED Floodlight 200W 11.9.6

12

20439

245269.2

... More
code137 - Do- LED Floodlight 240W 11.9.7

12

24274

291297.6

... More
code138 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. 13.5

84

178

14968.8

... More
code139 - Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws. Ding Dong Bell 12.2.1

20

270

5412

... More
code140 - Do- with Remote 12.2.3

5

1309

6545

... More
code141 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. 12.56

10

3861

38610

... More
code142 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all- round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. 12.57

10

4681

46816

... More
code143 - Supply and fixing GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip 12.58.3

60

140

8448

... More
code144 - Do- 25 x 3 mm Copper strip 12.58.7

30

627

18810

... More
code145 - Do- 600 x 600 x 3 mm Copper plate 12.58.11

10

8163

81631

... More
code146 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS- 3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) 32.05

0.25

156026

39006.55

... More
code147 - Do- 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) 32.07

1.6

153503

245606.24

... More
code148 - Do- 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm) 32.18

1.5

948932

1423398.9

... More
code149 - Do- 400 Sqmm, 3.5 Core, (39 GI Strips - 4 x 0.8 mm) 32.20

0.1

1598815

159881.59

... More
code150 - Laying LTUG cable of 2.5 to 25 Sqmm (Single/3.5/4 Core) 20.05

1.85

1305

2415.545

... More
code151 - Laying LTUG cable of 120 to 240 Sqmm (3.5/4 Core) 20.07

1.6

2973

4757.28

... More
code152 - Laying of UG Cables by Trenchless Technology (HDD) by adopting Horizontal Boring & Drawing of cable including preparation at site Normal soil 5/6'' Bore 28.01

120

1043

125268

... More
code153 - Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm 59.01

80

29

2376

... More
code154 - Do- 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm 59.10

40

390

15620

... More
code155 - Do- 400 Sqmm Copper Terminal, Apprx Wt: 395 Gm 59.12

12

949

11391.6

... More
code156 - Supply, Testing and commissioning of LT ACB 800 Amps 65.08

2

230860

461720.6

... More
code157 - Repairs and Reconditioning of 11KV class single coil/multi coil Conventional (Aluminium wound) and 3/4/5 Star Rated failed Distribution Transformers of various Capacities and Conversion of CSP to Conventional bolt & nut type on lumpsum percentage (%) basis (Material, Labour & Salvage) at Transformer repair center Note: 1.The rates are exclusive of Transformer Oil 2. The rates are for repair of 3 Coils 3. Released Oil has to be returned to the stored by concerned ESCOM officers 4. The released winding will be retained by the repair agency. (The salvage value is added in the rates)500 kVA, Aluminium Wdg, 3/4/5 Star

1

103266

103266.9

... More
code158 - Filtration of oil using filter set of the contractor to bring the insulation value to I.E. specification

1990

7

15323

... More
code159 - EHV Grade unused uninhibited mineral insulating oil in new steel barrels of 210 litres capacity strictly confirming to IEC 60296 (latest version) ( greater than 170kV class) 1.15

2

138578

277156

... More
code160 - Servicing of Air Circuit Breaker by isolating the breaker, cleaning of the ACB, cleaning of old grease, dust and oil content, cleaning of carbon from main contact terminal, cleaning of cluster contact studs, rail wheel and applying grease oil to rail. Cleaning the carbon on the Contact Mechanism and energizing including Microprocessor Logic testing including replacement of ELR, Moving contacts and relay as required., complete

15

24000

360000

... More
code161 - Supplyof Three Phase 50 Hz, 7.5 KW/10 HP Monoblock Openwell submersible pumpset made of cast iron body, stainless steel strainer with 50-75 mm discharge outlet including transport to the site in Bengaluru limits

2

45432

90864

... More
code162 - Erection charges of openwell pumpset. 13.3.19

2

2200

4400

... More
code163 - Transformer Servicing: Draining out the oil from Transformer, Removal of cable box, Removal of Terminal cables, Replacement of Bushing gasket, Oil seals (3 bushing side), Refitment of cables, stopping oil leakage, Refilling Oil to the transformer, Cleaning of all Terminal contacts, Removal of Carbon deposits, Tightening of Bolts and nuts, cleaning and Lubrication of Moving parts, rectification of contact Mechanisms and Tap positions and replacement of moving parts complete.,

3

21200

63600

... More
code164 - Spreading and forming 20/25 mm Jelly to required level as per specification including cost of all materials, labour, lead etc., complete

20

1645

32912

... More
code165 - Overhauling the Alternator of 500 KVA DG set: Dismantling the burntout Stator winding and Re-winding with 99.95% purity of copper coil and varnishing heating., Core re-rack and pressing, press out. Disamantling the bearing replacing with new 6319.13 bearing, Replacing all th diodes, Replacing the flange of Alternator, Dismantling the burntout Rotor winding and Re-winding with 99.95% purity of copper coil and varnishing heating., including Loading unloading, crane charges, Transportation charges complete.,

1

486000

486000

... More
code166 - Servicing of 250 KVA Diesel Generator including Draining out the lubricant, Removal of Terminal cables, Replacement of belts, gasket, Oil seals etc., filling of compatible lubricants, Refitment of cables, stopping oil leakage, Cleaning of all Terminal contacts, Removal of Carbon deposits, Tightening of Bolts and nuts, cleaning and Lubrication of Moving parts, rectification of contact Mechanisms and replacement of moving parts complete., with B-check of Diesel Generator sets.

1

90000

90000

... More
code167 - Servicing of 500 KVA Diesel Generator including Draining out the lubricant, Removal of Terminal cables, Replacement of belts, gasket, Oil seals etc., filling of compatible lubricants, Refitment of cables, stopping oil leakage, Cleaning of all Terminal contacts, Removal of Carbon deposits, Tightening of Bolts and nuts, cleaning and Lubrication of Moving parts, rectification of contact Mechanisms and replacement of moving parts complete., with B-check of Diesel Generator sets.

2

132000

264000

... More
code168 - Servicing of 600 KVA Diesel Generator including Draining out the lubricant, Removal of Terminal cables, Replacement of belts, gasket, Oil seals etc., filling of compatible lubricants, Refitment of cables, stopping oil leakage, Cleaning of all Terminal contacts, Removal of Carbon deposits, Tightening of Bolts and nuts, cleaning and Lubrication of Moving parts, rectification of contact Mechanisms and replacement of moving parts complete., with B-check of Diesel Generator sets.

1

174000

174000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.