Bangalore Electricity Supply Company Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bangalore Electricity Supply Company Limited - BESCOM Tender

Works
Civil And Construction
Civil Works Others
Opening Date7 Dec 2024
Closing Date8 Jan 2025
Tender Amount₹ 93,06,474.39 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
COM004 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. (Depth exceeding 1.5m, but not exceeding 3 mtr)

24

313

7521.36

... More
COM005 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications

300

176

52800

... More
COM006 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

180

129

23364

... More
COM007 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates)

70

10746

752280.2

... More
COM008 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates)

70

10877

761443.2

... More
COM009 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates)

25

11432

285804

... More
COM010 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification

11

96277

1059047.33

... More
COM011 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.

315

1455

458451

... More
COM012 - Providing 15 mm cement plaster on Solid Block wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

740

388

287120

... More
COM013 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Both Internal and External Area

740

194

143560

... More
COM014 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

1500

889

1333500

... More
COM015 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

9000

152

1368000

... More
COM016 - Providing and fixing roofing consist of 0.8 mm thick Galvanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).

24

1293

31032

... More
COM017 - Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400% and having solid content of above 90% @ 1.6kg/m2 in 2 coats to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification.

40

987

39480

... More
COM018 - Design, supplying, erecting testing and commissioning of-Passenger / Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3phase 50cycles ACsupply, powder coated/ Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or with out attendant operation, 7 segment display buttons, call register indicator, fire man drive, SS hand rails inside car, full length infra red curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS1 4665/2016 (with latest amendments part / section 1 to 5 with regards to general guidelines of firesafety rated doors, MRL Lbeams , pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of liftS Including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code(NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. (With out Machine room SS Finish) 8 passengers with 5 stops (Approved Makes : OTIS/JOHNSON/SCHINDLER/VALENS ELEVATOR PVT LTD)

1

1592677

1592677.88

... More
COM019 - Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS2509 with suitable size bends, metal / PVC Junction boxes , adhesive paste etc., and running before concreting thes lab. The conduit should be tied to there inforcementrods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2mm thick

250

72

18150

... More
COM020 - Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS2509 with suitable size bends, metal / PVC Junction boxes , adhesive paste etc., and running before concreting thes lab. The conduit should be tied to there inforcementrods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick

250

85

21450

... More
COM021 - Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS2509 with suitable size bends, metal / PVC Junction boxes , adhesive paste etc., and running before concreting thes lab. The conduit should be tied to there inforcementrods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32mm dia 2.5mm thick

50

113

5665

... More
COM022 - Supplying and fixing PVC/metal conduit deep junction box. a) 19/20mm deep junction box

50

53

2695

... More
COM023 - Supplying and fixing PVC/metal conduit deep junction box. b) 25mm deep junction box

30

61

1848

... More
COM024 - Supplying and fixing PVC/metal conduit deep junction box. c) 32mm deep junction box

5

67

335.5

... More
COM025 - Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete. a) upto 50mm conduit in CC Floor

50

75

3795

... More
COM026 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gand box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (Only for Light & Fan points) a) Short point up to 3Mtr from tapping point to out let via switch box

10

295

2959

... More
COM027 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gand box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (Only for Light & Fan points) b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

45

416

18760.5

... More
COM028 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gand box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (Only for Light & Fan points) c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

15

610

9157.5

... More
COM029 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gand box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (Only for Light & Fan points) d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box

5

744

3723.5

... More
COM030 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gand box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (Only for Light & Fan points) e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches box

5

1087

5439.5

... More
COM031 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. a) 1.5 sqmm (For 6A Sockets)

250

28

7150

... More
COM032 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. b) 2.5 sqmm (Lighting & UPS Circuits)

250

46

11550

... More
COM033 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. c) 4 sqmm

250

69

17325

... More
COM034 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. d) 6 sqmm

250

101

25300

... More
COM035 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-2 Way

12

151

1821.6

... More
COM036 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall b) 3 Way

5

174

874.5

... More
COM037 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall c) 6 Way

5

242

1210

... More
COM038 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall d) 8 Way

5

287

1435.5

... More
COM039 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. a) 1 to 3 Module

12

150

1808.4

... More
COM040 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. b) 4 Module

5

192

962.5

... More
COM041 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. c) 6 Module

5

257

1287

... More
COM042 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. d) 8 Module

5

312

1562

... More
COM043 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A 6 Amps one way switch

20

112

2244

... More
COM044 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A 6 Amps Two way switch

1

182

182.6

... More
COM045 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A 6Amps 3way socket.

10

188

1881

... More
COM046 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A Stepped fan regulator

1

392

392.7

... More
COM048 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A 16Amps one way switch

4

198

792

... More
COM049 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A 6/16Amps universal socket

4

259

1038.4

... More
COM050 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A RJ45 / I.O outlet Cat-6

4

370

1482.8

... More
COM051 - CONTROL SWITCH GEARS & ACCESSORIES- Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10KA, complete wiring as required confirming to IEC 60898. a) 6-32Amps SP

10

456

4565

... More
COM052 - CONTROL SWITCH GEARS & ACCESSORIES- Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10KA, complete wiring as required confirming to IEC 60898. b) 6-32Amps DP

1

812

812.9

... More
COM053 - CONTROL SWITCH GEARS & ACCESSORIES- Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10KA, complete wiring as required confirming to IEC 60898. d) 6-32Amps TPN

1

1888

1888.7

... More
COM054 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure b) Double Door 8 Way SP & N

1

1970

1970.1

... More
COM055 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure d) Double Door 4 Way TP & N

1

4441

4441.8

... More
COM056 - Supplying,fixingandwiringearthleakagerelaywithcorebalancedcurrenttransformersuitableforsinglephase50HzACwithlatestmicrocontrollerbased,digitalreadoutofpercentageleakagecurrent,programmabledelay/auto/manualresetfacilitysuitabletomountonDIN rail/ flush mounting on panel board. a) 32-40Amps 4 pole

1

10180

10180.5

... More
COM057 - L.T. U.G. CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover.The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

1

3861

3861

... More
COM058 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required-GI STRIPS - 25x3MM

50

90

4510

... More
COM059 - 8SWG GI Wire

30

199

5973

... More
COM060 - Supplying & Installation of 1.1KV LT UG cable XLPE or heat resistant PVC insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. including gland and lugs. 4 Core 10 Sqmm

0.5

129804

64902.2

... More
COM061 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable 2.5 Sqmm to 25 Sqmm

3

22974

68922

... More
COM062 - CIVIL WORKS RELATED TO ELECTRICAL WORKS Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc…complete. (As per civil SR KSRB I-2, P-7) In Hard soil

22.6

1245

28141.52

... More
COM063 - Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand).

22.6

16291

368176.6

... More
COM064 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

1

541

541.2

... More
COM065 - LED INDOOR Supplying of 2 feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI 8. Power Input : 220-240V @ 50 Hz & power factor 0.9 along with CE approved drivers. 2 years warrwnty against any manufacturing defect working under standard lectrical condition. a) Led light fitting 2 - 9 / 10/ 11 watts

5

606

3030.5

... More
COM066 - LED INDOOR Supplying of 2 feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI 8. Power Input : 220-240V @ 50 Hz & power factor 0.9 along with CE approved drivers. 2 years warrwnty against any manufacturing defect working under standard lectrical condition. b) Led light fitting 4' - 20 / 22 watts

5

759

3795

... More
COM067 - Supply of LED Street light with pressure die cast aluminum housing body with optimal heat sink for better thermal dissipation. Diffuser with injection moulded & is made of polycarbonate material with high transmission index, delivering supirior light output. Rated life burning Hrs 50000 hr @ lumen maintainence of 70%. CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7A & surge protection - min 4KV along with over voltage/overload, short circuit/ mis wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal voltage driver to operate wide range from 100v to 270V 50/60Hz application. Overload & short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to enxsure ease of maintainence at the sight site location with minimized minimal tools. LED Light fixture with .........W system power consumption. LEd efficiency 130ml/w at 1w and fixture efficiency 75ml/w with CRI 75. luminaire Manufacturer should have inhouse facility accredited by NABL/CPRI & any government certified agency & design & development facility certified by ISO 9001:2008. Housing with supplier word mark/name shall be engraved / embassing on the die cast housing / body part. 2 years warranty against any manufacturing defect working under standard a) LED Street light 40W

5

4426

22132

... More
COM068 - Supplying and fixing of Hot Dip Galvanized M.S Bracket suitable for out door luminairs and mounted on octoganal pole using necessary bolts, nuts etc…. Complete a) Single Arm Bracket with 1000mm Standard 40/50MM dia.

10

1870

18700

... More
COM069 - Supplying, erecting, testing and commisioning of OFF-LINE UPS System suitable for operation on 230V Input and 230V, Output, 50Hz, A/C supply with all accessories complete and excluding batteries and wiring complete. 2 KVA OFFLINE UPS (For Emergency Lighting only)

1

23422

23422.3

... More
COM070 - Supplying, installation, testing & commissioning of 12volts DC AH Batteries in poly propylene container for UPS Sealed maintainence free batteries. 12V, 75-80 AH Capacity. Acid battery.

2

11189

22378.4

... More
COM071 - Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified

6

2389

14335.2



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.