Bangalore Electricity Supply Company Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bangalore Electricity Supply Company Limited - BESCOM Tender

Works
Civil And Construction
Building Construction
Opening Date5 Dec 2024
Closing Soon20 Dec 2024
Tender Amount₹ 50,84,701.03 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - do staircase & roof slab -Second Floor (Including formwork charges). ---- as per NIT and KW terms and conditions

25

10892

272319.75

... More
code05 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Do-TMT reinforcement Second Floor (KPWD SR 2024-25/Vol 1/Item No:2.11 a/Pg.No:18) ---- as per NIT and KW terms and conditions

9.5

93992

892930.935

... More
code06 - Providing brickwork with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. do-Second Floor Brick work (KPWD SR 2024-25/Vol 2/Item No:6.7/Pg.No:13) ---- as per NIT and KW terms and conditions

25

8637

215945.5

... More
code07 - Providing 12 mm cement plaster (ceiling surface) with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.do-Second Floor ceiling Plastering (KPWD SR 2024-25/Vol 2/Item No:8.1.1/Pg.No:41) ---- as per NIT and KW terms and conditions

300

267

80376

... More
code08 - Providing 20 mm cement plaster (internal surface) of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. do-Second Floor Internal surface Plastering (KPWD SR 2024-25/Vol 2/Item No:8.3.2/Pg.No:41) ---- as per NIT and KW terms and conditions

250

349

87470

... More
code09 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. do-Second Floor putty (KPWD SR 2024-25-vol 2 -Item No:8.51-pg.No:50) ---- as per NIT and KW terms and conditions

500

105

52535

... More
code10 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)do-Ground Floor (KPWD SR 2024-25/vol 2/Item No:8.33.1/Pg.No:46) ---- as per NIT and KW terms and conditions

1800

162

292932

... More
code11 - Providing 20 mm cement plaster of mix :1:4 (External surface) (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(KPWD SR 2024-25/Vol 2/Item No:8.3.1/Pg.No:41) ---- as per NIT and KW terms and conditions

450

371

167373

... More
code12 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kgs/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. do-Ground Floor (KPWD SR 2024-25/Vol 2/Item No:8.30/Pg.No:46) ---- as per NIT and KW terms and conditions

1700

179

304674

... More
code13 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kgs/ m2 including grouting the joints with white cement and matching pigments etc., complete.. Size of Tile 600x600 mm do-Second Floor vitrified floor Size of Tile 600x600 mm (KPWD SR 2024-25/Vol 2/Item No:9.17.5/Pg.No:61) ---- as per NIT and KW terms and conditions

150

1398

209724

... More
code14 - Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS: 15622 (thickness to be specified by the manufacturer), ofapproved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer- in-Charge, in skirting,risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3Kgs per m2, including pointing in white cement mixed with pigmentof matching shade complete.do- Second Floor ceramic glazed wall tiles (KPWD SR 2024-25/Vol 2/Item No:10.14/Pg.No:71) ---- as per NIT and KW terms and conditions

50

1162

58103.5

... More
code15 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kgs/ m2 including pointing the joints with white cement and matching pigments etc., complete. (KPWD SR 2024-25/Vol 2/Item No:9.11/Pg.No:60) ---- as per NIT and KW terms and conditions

35

934

32692.45

... More
code16 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in2coats @ 1.6Kgs per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge etc., complete with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc.,(KPWD SR 2024-25/Vol 2/Item No:15.1/Pg.No:131) ---- as per NIT and KW terms and conditions

250

841

210377.5

... More
code17 - Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 Kgs/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(KPWD SR 2024-25/Vol 2/Item No:15.6/Pg.No:132) ---- as per NIT and KW terms and conditions

50

522

26110.5

... More
code18 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.(KPWD SR 2024-25/Vol 2/Item No:12.11/Pg.No:99) ---- as per NIT and KW terms and conditions

0.25

142216

35554.055

... More
code19 - Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) (KPWD SR 2024-25/Vol 2/Item No:12.2/Pg.No:100) ---- as per NIT and KW terms and conditions

10

6334

63345

... More
code20 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.--do- 30 mm thick one side teak and one side commercial (KPWD SR 2024-25/Vol 2/Item No:12.57.2/Pg.No:104) ---- as per NIT and KW terms and conditions

30

3597

107933.7

... More
code21 - Providing & fixing Factory made single extruded Wood Polymer Composite (WPC) solid door/window, clerestory windows & frames /chowkhat of frame size 65 x 100mm(KPWD SR 2024-25/Vol 2/Item No:12.93.1 ) ---- as per NIT and KW terms and conditions

94

723

67967.64

... More
code22 - Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge. (KPWD SR 2024-25/Vol 2/Item No:22.3/Pg.No:217) ---- as per NIT and KW terms and conditions

75

3048

228660

... More
code23 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(KPWD SR 2024-25/Vol 2/Item No:8.41/Pg.No:48) ---- as per NIT and KW terms and conditions

65

172

11180.65

... More
code24 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (KPWD SR 2024-25/Vol 2/Item No:11.16.2/Pg.No:81) ---- as per NIT and KW terms and conditions

650

151

98416.5

... More
code25 - WARDROBE AND FURNISHING Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge. (KPWD SR 2024-25/Vol 2/Item No:22.3/Pg.No:217) ---- as per NIT and KW terms and conditions

75

3048

228660

... More
code26 - Providing and supplying Kitchen cabinet with 19mm thick one side Architect recommended decorative Acrylic Glossy or Matt finished laminate (1.5mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand . complete as per direction of engineer in-charge.(KPWD SR 2024-25/Vol 2/Item No:22.4/Pg.No:217) ---- as per NIT and KW terms and conditions

45

3193

143685

... More
code27 - Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge.150 mm length (KPWD SR 2024-25/Vol 2/Item No:22.9 B/Pg.No:218) ---- as per NIT and KW terms and conditions

80

1390

111240

... More
code28 - PLUMBING AND SANITARY WORK Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete 2.00 HP/1.5KW, 12 STG .(KPWD SR 2024-25 / VOL5/ I.N:13.8.3/pg no:150) ---- as per NIT and KW terms and conditions

1

18146

18146.54

... More
code29 - Providing and placing on terrace, (at all floor levels) polyethylene water storage tanks IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting sand the base support for tank. (Vol-2, I.No : 13.34) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charge sand all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. (KPWD SR 2024-25 / VOL2/ I.N:13.34 Page 123) ---- as per NIT and KW terms and conditions

2000

9

18540

... More
code30 - Supplying PVC ring tite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials(excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to th required pressure as per ISS(Contractor will make his own arrangements for procuring water for testing)etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 (Vol-5 , P.No-113/10.1.8) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., (KPWD SR 2024-25 / VOL5/ I.N:10.1.8/P.N:113) ---- as per NIT and KW terms and conditions

60

601

36091.2

... More
code31 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials(excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to th required pressure as per ISS(Contractor will make his own arrangements for procuring water for testing)etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (Vol-5 , P.No-113/10.1.7) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. (KPWD SR 2024-25 / VOL5/ Item No:10.1.7 M010G/Pg.No:113) ---- as per NIT and KW terms and conditions

70

423

29633.1

... More
code32 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials(excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to th required pressure as per ISS(Contractor will make his own arrangements for procuring water for testing)etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3(Vol-5 , P.No-113/10.1.5) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. KPWD SR 2024-25 / VOL5/ Item No:10.1.5 M010E M010G/Pg.No:113 ---- as per NIT and KW terms and conditions

50

226

11330

... More
code33 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 40mm nominal OD pipes (Vol-2 , P.No-122/13.31.5) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. (KPWD SR 2024-25 / VOL2/ Item No:13.31.5/Pg.No:122) ---- as per NIT and KW terms and conditions

50

552

27604

... More
code34 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming toIS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 32mm nominal OD pipes (Vol-2 , P.No-122/13.31.4) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:1.13.31.4/Pg.No:122) ---- as per NIT and KW terms and conditions

70

412

28840

... More
code35 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 25 mm nominal OD pipes (Vol-2 , P.No-122/13.31.3) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charge sand all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.31.3/Pg.No:122) ---- as per NIT and KW terms and conditions

110

327

36029.4

... More
code36 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 20mm nominal OD pipes (Vol-2 , P.No-122/13.31.2) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charge sand all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.31.2/Pg.No:122) ---- as per NIT and KW terms and conditions

60

249

14955.6

... More
code37 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore ( Vol-2, P.No-117/13.4.1) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.4.1/Pg.No:117) ---- as per NIT and KW terms and conditions

5

565

2827.35

... More
code38 - Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore, Horizontal (Vol-2, P.No-117 / 13.6.1.1) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.6.1.1/Pg.No:117) ---- as per NIT and KW terms and conditions

5

638

3193

... More
code39 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern &C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Vol-2, P.No-131/14.3.1) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.-W.C. pan with ISI marked white solid plastic seat and lid (KPWD SR 2024-25 / VOL2/ Item No:14.3.1/Pg.No:131) ---- as per NIT and KW terms and conditions

2

6156

12312.62

... More
code40 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps(Vol-2, P.No-132/14.7.1)etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. -White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (KPWD SR 2024-25 / VOL2/ Item No:14.7.1/Pg.No:132) ---- as per NIT and KW terms and conditions

2

3174

6348.92

... More
code41 - Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.(KPWD SR 2024-25 / VOL2/ Item No:14.22A/Pg.No:135) ---- as per NIT and KW terms and conditions

2

834

1668.6

... More
code42 - Providing and fixing 100 mm sand cast Iron grating for gully trap. etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:14.29/Pg.No:136) ---- as per NIT and KW terms and conditions

5

48

242.05

... More
code43 - Providing and fixing brass bib cock of approved quality : 20 mm nominal bore etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.2.2/Pg.No:117) ---- as per NIT and KW terms and conditions

5

314

1570.75

... More
code44 - Providing and fixing brass stop cock of approved quality : 20 mm nominal bore(Vol-2, P.No-117/13.3.2) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.3.2/Pg.No:117) ---- as per NIT and KW terms and conditions

5

314

1570.75

... More
code45 - Providing and fixing SS towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, ., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. ( KPWD SR 2024-25/VOL 2/Item 14.40.2/ Page No 137) ---- as per NIT and KW terms and conditions

2

510

1021.76

... More
code46 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. KPWD SR 2024-25 / VOL2/ Item No:14.31/Pg.No:136 ---- as per NIT and KW terms and conditions

2

1256

2513.2

... More
code47 - Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (P.No-191 Item 16.8) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL5/ Item No:16.8 Pg.No:191) ---- as per NIT and KW terms and conditions

3

4934

14804.19

... More
code48 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ( P.No-191 Item 16.9) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL5/ Item No: 16.9 Pg.No:191) ---- as per NIT and KW terms and conditions

3

5617

16852.86

... More
code49 - Providing and fixing PVC ( SWR) Nahani trap of approved make conforming to ISI specifications 10cms x 10 cms., Complete as per specification, all lead, lifts, curing and the directions of Engineer in-charge of the site. ( KPWD SR 2024-25/VOL 2/Item 13.59 Page 127) ---- as per NIT and KW terms and conditions

5

226

1133

... More
code50 - ELECTRICAL WORKS :- Concealed Conduit System -Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary-19/20mm dia 2mm thick.(KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.2.1 /Pg.No:2 -105) ---- as per NIT and KW terms and conditions

100

67

6798

... More
code51 - Concealed Conduit System -Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary- 25mm dia 2mm thick. (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.2.2 /Pg.No:2 -105) ---- as per NIT and KW terms and conditions

150

80

12051

... More
code52 - Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-19/20mm dia 2mm thick-. (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.3.1 / Pg.No:2 -105) ---- as per NIT and KW terms and conditions

50

70

3502

... More
code53 - Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-25mm dia 2mm thick -25mm dia 2mm thick. (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.3.2 / Pg.No:2 -105) . ---- as per NIT and KW terms and conditions

150

81

12205.5

... More
code54 - Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required. 20mm size- (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.8.1 / Pg.No:3 -105) . ---- as per NIT and KW terms and conditions

25

28

721

... More
code55 - Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required. 25mm size- (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.8.2 / Pg.No:3 -105) . ---- as per NIT and KW terms and conditions

25

36

901.25

... More
code56 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet.-Short point upto 3Mtr from tapping point to out let via switch . (KPWD SR 2024-25 /Volume-6- part-3 / Item No:2.2.1 / Pg.No:5 -105) ---- as per NIT and KW terms and conditions

4

277

1108.28

... More
code57 - Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. -Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.(KPWD SR 2024-25 / VOL6/ Item No:2.2.2 /Pg.No:5 of 105). ---- as per NIT and KW terms and conditions

10

390

3903.7

... More
code58 - Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.(KPWD SR 2024-25 / VOL6/ Item No:2.2.3 /Pg.No:5 of 105) ---- as per NIT and KW terms and conditions

41

571

23437.65

... More
code59 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches. .(KPWD SR 2024-25 / VOL6/ Item No:2.2.4 /Pg.No:5 of 105) ---- as per NIT and KW terms and conditions

2

697

1394.62

... More
code60 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box.(KPWD SR 2024-25 / VOL6/ Item No:2.2.5 /Pg.No:5 of 105) ---- as per NIT and KW terms and conditions

4

1018

4074.68

... More
code61 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/ C.C. wall 3 way .(KPWD SR 2024-25 / VOL6/ Item No:3.4.2 /Pg.No:8 of 105) ---- as per NIT and KW terms and conditions

50

163

8188.5

... More
code62 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 4-5 way .(KPWD SR 2024-25 / VOL6/ Item No:3.4.3 /Pg.No:8 of 105) ---- as per NIT and KW terms and conditions

50

182

9115.5

... More
code63 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 6way. (KPWD SR 2024-25 / VOL6/ Item No:3.4.4 /Pg.No:8 of 105) ---- as per NIT and KW terms and conditions

15

226

3399

... More
code64 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 8way. (KPWD SR 2024-25 / VOL6/ Item No:3.4.5 /Pg.No:5 of 105) ---- as per NIT and KW terms and conditions

15

268

4032.45

... More
code65 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 10-12way. (KPWD SR 2024-25 / VOL6/ Item No:3.4.6 /Pg.No:8 of 105) ---- as per NIT and KW terms and conditions

5

328

1642.85

... More
code66 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 3 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.2 /Pg.No:8 of 105) ---- as per NIT and KW terms and conditions

50

165

8291.5

... More
code67 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 4 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.3 /Pg.No: 8 of 105) ---- as per NIT and KW terms and conditions

50

180

9012.5

... More
code68 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 6 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.4 /Pg.No: 8 of 105) ---- as per NIT and KW terms and conditions

15

241

3615.3

... More
code69 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 8 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.5 /Pg.No: 8 of 105) ---- as per NIT and KW terms and conditions

15

292

4387.8

... More
code70 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 10-12 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.6 /Pg.No:8 of 105) ---- as per NIT and KW terms and conditions

5

354

1771.6

... More
code71 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. 6Amps one way Switch. (KPWD SR 2024-25 / VOL6/ Item No:3.6.1 /Pg.No: 9 of 105) ---- as per NIT and KW terms and conditions

71

105

7459.26

... More
code72 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293.- 6Amps two way Switch. (KPWD SR 2024-25 / VOL6/ Item No:3.6.2 /Pg.No:9 of 105) ---- as per NIT and KW terms and conditions

6

170

1025.88

... More
code73 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293.- 6Amps 3way socket. (KPWD SR 2024-25 / VOL6/ Item No:3.6.3 /Pg.No:9 of 105) ---- as per NIT and KW terms and conditions

55

176

9687.15

... More
code74 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. -Stepped Fan Regulator. (KPWD SR 2024-25 / VOL6/ Item No:3.6.4 /Pg.No: 9 of 105) ---- as per NIT and KW terms and conditions

13

367

4780.23

... More
code75 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. - 6/16Amps One way switch. (KPWD SR 2024-25 / VOL6/ Item No:3.6.7 /Pg.No: 9 of 105) ---- as per NIT and KW terms and conditions

32

185

5932.8

... More
code76 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. - 6/16Amps universal socket. (KPWD SR 2024-25 / VOL 6/ Item No:3.6.10 /Pg.No: 9 of 105). ---- as per NIT and KW terms and conditions

17

243

4132.36

... More
code77 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293.- RJ 45/I.O outlet cat -6. (KPWD SR 2024-25 / VOL6/ Item No:3.6.12 /Pg.No: 9 of 105) ---- as per NIT and KW terms and conditions

15

347

5206.65

... More
code78 - Supplying and drawing UTP-CAT 6E LAN cable. - (KPWD SR 2024-25 / VOL6/ Item No:8.1 /Pg.No: 36 of 105) ---- as per NIT and KW terms and conditions

350

39

13699

... More
code79 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments-1.5 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.2 /Pg.No: 5 of 105) ---- as per NIT and KW terms and conditions

1400

26

37492

... More
code80 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments- 2.5 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.3 /Pg.No: 5 of 105) ---- as per NIT and KW terms and conditions

1800

43

77868

... More
code81 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010confirming to latest amemndments-4 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.4 /Pg.No: 5 of 105) ---- as per NIT and KW terms and conditions

600

64

38934

... More
code82 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments- 6 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.5 /Pg.No: 5 of 105) ---- as per NIT and KW terms and conditions

40

94

3790.4

... More
code83 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments- 10 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.6 /Pg.No: 5 of 105) ---- as per NIT and KW terms and conditions

3

172

516.03

... More
code84 - FITTINGS - Supplying and fixing of .4' feet - PVC Batten with integrated LED tube 20/22.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-4 feet LED Fitting. (KPWD SR 2024-25 / VOL6/ Item No:11.3.2 /Pg.No: 43 of 105) ---- as per NIT and KW terms and conditions

30

710

21321

... More
code85 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. ( BLDC fans) (KPWD SR 2024-25 / VOL6/ Item No:6.4.1 /Pg.No: 30 of 105)- 48" sweep 5star (1200mm) ---- as per NIT and KW terms and conditions

4

2757

11029.24

... More
code86 - Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(KPWD SR 2024-25 / VOL6/ Item No:13.11 /Pg.No: 57 of 105) ---- as per NIT and KW terms and conditions

4

324

1297.8

... More
code87 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely.(KPWD SR 2024-25 / VOL6/ Item No:5.45.2/Pg.No: 21 of 105) ---- as per NIT and KW terms and conditions

7

1000

7000.91

... More
code88 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (KPWD SR 2024-25 / VOL6/ Item No:5.18.4 /Pg.No:17 of 105). ---- as per NIT and KW terms and conditions

7

761

5328.19

... More
code89 - Supply of round/square recess/surface mounted rolling type LED Down light with LED square or round down light 15-18W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working (KPWD SR 2024-25 / VOL6/ Item No:11.5.3/Pg.No:44 of 105). ---- as per NIT and KW terms and conditions

6

1363

8182.32

... More
code90 - CONSUMER CONTROL PANEL :- Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings. confirming to IS/IEC 60898 - 2. - 8way .(KPWD SR 2024-25 / VOL6/ Item No:5.17.2/Pg.No: 17 of 105) ---- as per NIT and KW terms and conditions

1

12983

12983.15

... More
code91 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.- 100A MCCB -25KA-4Pole. .(KPWD SR 2024-25 / VOL6/ Item No:5.15.9/Pg.No:17 of 105) ---- as per NIT and KW terms and conditions

1

8741

8741.61

... More
code92 - Supplying and fixing Miniature Circuit Breakers in existing MCB distribution boards using necessary fixing material and C type curve, indicator ON/OFF, energy cross -3 with short circuit breaking capacity of 10k and complete wiring as required confirming to IEC60898. 63Amps TPN MCB .(KPWD SR 2024-25 / VOL6/ Item No:5.18.8 /Pg.No:17 of 105) ---- as per NIT and KW terms and conditions

5

3180

15903.2

... More
code93 - Supplying and fixing Miniature Circuit Breakers in existing MCB distribution boards using necessary fixing material and C type curve, indicator ON/OFF, energy cross -3 with short circuit breaking capacity of 10k and complete wiring as required confirming to IEC60898. 6-32A SP MCB. (KPWD SR 2024-25 / VOL6/ Item No:5.18.1 /Pg.No: 17 of 105) ---- as per NIT and KW terms and conditions

9

427

3847.05

... More
code94 - FLOOR WISE DB :- Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.- 8 way TP&N Double door DB . (KPWD SR 2024-25 / VOL6/ Item No:5.19.13 /Pg.No: 18 of 105) ---- as per NIT and KW terms and conditions

2

6273

12547.46

... More
code95 - Supplying, fixing and wiring Residual current Circuit Breaker ( RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. - 63A 4 pole. (KPWD SR 2024-25 / VOL6/ Item No:5.20.4 /Pg.No: 18 of 105) ---- as per NIT and KW terms and conditions

2

5711

11422.7

... More
code96 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ( 6-32A SP MCB ). (KPWD SR 2024-25 / VOL6/ Item No:5.18.1 /Pg.No: 17 of 105) ---- as per NIT and KW terms and conditions

5

427

2137.25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.