Bangalore Electricity Supply Company Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bangalore Electricity Supply Company Limited - BESCOM Tender

Works
Civil And Construction
Building Construction
Opening Date5 Dec 2024
Closing Soon20 Dec 2024
Tender Amount₹ 84,74,479.93 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (KPWD SR 2024-25/Vol 2/ Item No:4.1/Pg.No:5) ---- As per NIT and KW terms and conditions

70

121

8507.8

... More
code05 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (KPWD SR 2024-25/Vol 1/Item No:1.8/Pg.No:33,34) ---- As per NIT and KW terms and conditions

120

488

58586.4

... More
code06 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (KPWD SR 2024-25/Vol 1/Item No:1.9/Pg.No:34) ---- As per NIT and KW terms and conditions

80

273

21918.4

... More
code07 - Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. (KPWD SR 2024-25/Vol-1/Item.No.1.23 Page No 11) ---- As per NIT and KW terms and conditions

12

2762

33149.52

... More
code08 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (KPWD SR 2024-25/Vol 2/Item No:5.4/pg.No:9) ---- As per NIT and KW terms and conditions

80

6580

526453.6

... More
code09 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M7.5) Using 40 mm nominal size graded crushed coarse aggregates (KPWD SR 2024-25 /Vol 1/Item No:2.1.2/Pg.No:15 ) ---- As per NIT and KW terms and conditions

15

5833

87508.8

... More
code10 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-FOOTING Including formwork charges for Footing etc. (KPWD SR 2024-25/Vol -1/Item No-2.2.3/Pg.No-15) ---- As per NIT and KW terms and conditions

25

7048

176204.25

... More
code11 - do columns upto plinth (Including formwork charges). ---- As per NIT and KW terms and conditions

6

11094

66566.04

... More
code12 - do Plinth Beam (Including formwork charges). ---- As per NIT and KW terms and conditions

12

9789

117469.44

... More
code13 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevantIS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates(KPWD SR 2024-25/Vol -1/Item No-2.4.2/Pg.No-74) ---- As per NIT and KW terms and conditions

8

8792

70337.04

... More
code14 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do columns Ground Floor (Including formwork charges) (KPWD SR 2024-25/Vol -1/Item No: 2.5.2/Pg.No -16) ---- As per NIT and KW terms and conditions

8

11982

95856.72

... More
code15 - do columns First Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

6

12101

72611.46

... More
code16 - do columns Second Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

2

12222

24445.86

... More
code17 - do beams, lintels- Ground Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

10

11277

112772.6

... More
code18 - do beams, lintels- First Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

10

11390

113900.4

... More
code19 - do beams, lintels- Second Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

2

11503

23007.88

... More
code20 - do staircase, slab- Ground Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

15

10572

158586.6

... More
code21 - do staircase, slab- First Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

15

10678

160172.4

... More
code22 - do staircase, slab- Second Floor (Including formwork charges). ---- As per NIT and KW terms and conditions

2

10784

21569.88

... More
code23 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Do-Foundation work (KPWD SR 2024-25/Vol 1/Item No:2.11 a/Pg.No:18) ---- As per NIT and KW terms and conditions

9

92140

829266.39

... More
code24 - Do-TMT reinforcement Ground Floor ---- As per NIT and KW terms and conditions

7

92140

644984.97

... More
code25 - Do-TMT reinforcement First Floor ---- As per NIT and KW terms and conditions

7

93062

651434.77

... More
code26 - Do-TMT reinforcement Second Floor ---- As per NIT and KW terms and conditions

2

94932

189865.34

... More
code27 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (KPWD SR 2024-25/Vol 2/Item No:6.32/Pg.No:17) ---- As per NIT and KW terms and conditions

300

1349

404790

... More
code28 - Providing brickwork with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. (KPWD SR 2024-25/Vol 2/Item No:6.7/Pg.No:13) ---- As per NIT and KW terms and conditions

15

8457

126859.95

... More
code29 - Providing 12 mm cement plaster (ceiling surface) with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(KPWD SR 2024-25/Vol 2/Item No:8.1.1/Pg.No:41) ---- As per NIT and KW terms and conditions

150

262

39397.5

... More
code30 - Providing 20 mm cement plaster of mix :1:4 (internal surface) (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(KPWD SR 2024-25/Vol 2/Item No:8.3.2/Pg.No:41) ---- As per NIT and KW terms and conditions

300

342

102897

... More
code31 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (KPWD SR 2024-25-vol 2 -Item No:8.51-pg.No:50) ---- As per NIT and KW terms and conditions

300

103

30900

... More
code32 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work(Two coats applied @ 1.43 litre/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (KPWD SR 2024-25/vol 2/Item No:8.32/Pg.No:46) ---- As per NIT and KW terms and conditions

400

160

64272

... More
code33 - Providing 20 mm cement plaster (external surface) of mix :1:4 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (KPWD SR 2024-25/Vol 2/Item No:8.3.1/Pg.No:41) ---- As per NIT and KW terms and conditions

1900

364

692778

... More
code34 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (KPWD SR 2024-25/Vol 2/Item No:8.30/Pg.No:46) ---- As per NIT and KW terms and conditions

1335

179

239258.7

... More
code35 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.. Size of Tile 600x600 mm (KPWD SR 2024-25/Vol 2/Item No:9.17.2/Pg.No:61) ---- As per NIT and KW terms and conditions

115

1210

139178.75

... More
code36 - Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(KPWD SR 2024-25/Vol 2/Item No:9.32/Pg.No:64) ---- As per NIT and KW terms and conditions

10

2659

26594.6

... More
code37 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (KPWD SR 2024-25/Vol 2/Item No:9.30/Pg.No:64) ---- As per NIT and KW terms and conditions

15

5487

82317.6

... More
code38 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge (Vol 2,P.No. 69, I.No. 10.2 of PWD SR 2024-25) ---- As per NIT and KW terms and conditions

70

337

23648.8

... More
code39 - Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS: 15622 (thickness to be specified by the manufacturer), ofapproved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer- in-Charge, in skirting,risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per m2, including pointing in white cement mixed with pigmentof matching shade complete.r (KPWD SR 2024-25/Vol 2/Item No:10.14/Pg.No:71) ---- As per NIT and KW terms and conditions

32

1139

36453.76

... More
code40 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. do-Ground Floor(KPWD SR 2024-25/Vol 2/Item No:9.11/Pg.No:60) ---- As per NIT and KW terms and conditions

11

915

10072.37

... More
code41 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications (KPWD SR 2024-25/Vol 2/Item No:7.18/Pg.No:23) ---- As per NIT and KW terms and conditions

4

2077

8310.04

... More
code42 - Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. (KPWD SR 20232024Vol 2/Item No:9.2/Pg.No:59) ---- As per NIT and KW terms and conditions

180

824

148320

... More
code43 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge etc., complete with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc.,(KPWD SR 2024-25/Vol 2/Item No:15.1/Pg.No:149) ---- As per NIT and KW terms and conditions

60

841

50490.6

... More
code44 - Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(KPWD SR 2024-25/Vol 2/Item No:15.6/Pg.No:150) ---- As per NIT and KW terms and conditions

50

522

26110.5

... More
code45 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.(KPWD SR 2024-25/Vol 2/Item No:12.11/Pg.No:99) ---- As per NIT and KW terms and conditions

0.45

142216

63997.299

... More
code46 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.--do- 30 mm thick one side teak and one side commercial (KPWD SR 2024-25/Vol 2/Item No:12.57.2/Pg.No:104) ---- As per NIT and KW terms and conditions

14

3597

50369.06

... More
code47 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (KPWD SR 2024-25/Vol 2/Item No:12.60/Pg.No:105) ---- As per NIT and KW terms and conditions

6

1083

6501.36

... More
code48 - Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (KPWD SR 2024-25/Vol 2/Item No:12.58/Pg.No:105) ---- As per NIT and KW terms and conditions

6

123

741.6

... More
code49 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (KPWD SR 2024-25/Vol 2/Item No:12.62/Pg.No:105) ---- As per NIT and KW terms and conditions

12

244

2929.32

... More
code50 - Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10mm (KPWD SR 2024-25/Vol 2 /Item No:12.76.1/Pg.No:107) ---- As per NIT and KW terms and conditions

24

448

10753.2

... More
code51 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type) (KPWD SR 2024-25/Vol 2/Item No:12.75.1/Pg.No:107) ---- As per NIT and KW terms and conditions

21

283

5948.25

... More
code52 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. (KPWD SR 2024-25/Vol 2/Item No:12.51/Pg.No:104) ---- As per NIT and KW terms and conditions

6

1046

6278.88

... More
code53 - Providing & fixing Factory made single extruded Wood Polymer Composite (WPC) solid door/window, clerestory windows & frames /chowkhat of frame size 65 x 100mm(KPWD SR 2024-25/Vol 2/Item No:12.93.1 ,Pg.No: 111 ) ---- As per NIT and KW terms and conditions

20

723

14461.2

... More
code54 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness (KPWD SR 2024-25/Vol 2/Item No:12.94.2 Pg.No: 112 ) ---- As per NIT and KW terms and conditions

7

4162

29135.61

... More
code55 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.(KPWD SR 2024-25/Vol 2/Item No:11.34A/Pg.No:86) ---- As per NIT and KW terms and conditions

1000

173

173040

... More
code56 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(KPWD SR 2024-25/Vol 2/Item No:8.41/Pg.No:48) ---- As per NIT and KW terms and conditions

59

172

10148.59

... More
code57 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. (KPWD SR 2024-25/Vol 2/Item No:11.28/Pg.No:85) ---- As per NIT and KW terms and conditions

200

581

116390

... More
code58 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (KPWD SR 2024-25/Vol 2/Item No:11.16.2/Pg.No:82) ---- As per NIT and KW terms and conditions

800

151

121128

... More
code59 - Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(KPWD SR 2024-25/Vol 2/Item No:11.3/Pg.No:77) ---- As per NIT and KW terms and conditions

8

8524

68194.24

... More
code60 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(KPWD SR 2024-25/Vol 2/Item No:11.5.1/Pg.No:77) ---- As per NIT and KW terms and conditions

8

4612

36898.72

... More
code61 - PLUMBING AND SANITARY WORK Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete 2.00 HP/1.5KW, 12 STG .(KPWD SR 2024-25 / VOL5/ I.N:13.8.3/pg no:150) ---- As per NIT and KW terms and conditions

1

18146

18146.54

... More
code62 - Providing and placing on terrace, (at all floor levels) polyethylene water storage tanks IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting sand the base support for tank. (Vol-2, I.No : 13.34) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charge sand all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. (KPWD SR 2024-25 / VOL2/ I.N:13.34 Page 123) ---- As per NIT and KW terms and conditions

2000

9

18540

... More
code63 - Supplying PVC ring tite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials(excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to th required pressure as per ISS(Contractor will make his own arrangements for procuring water for testing)etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 (Vol-5 , P.No-113/10.1.8) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., (KPWD SR 2024-25 / VOL5/ I.N:10.1.8/P.N:113) ---- As per NIT and KW terms and conditions

60

601

36091.2

... More
code64 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials(excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to th required pressure as per ISS(Contractor will make his own arrangements for procuring water for testing)etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. (KPWD SR 2024-25 / VOL5/ Item No:10.1.7 M010G/Pg.No:113) ---- As per NIT and KW terms and conditions

70

423

29633.1

... More
code65 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials(excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to th required pressure as per ISS(Contractor will make his own arrangements for procuring water for testing)etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. KPWD SR 2024-25 / VOL5/ Item No:10.1.5 M010E M010G/Pg.No:113 ---- As per NIT and KW terms and conditions

50

226

11330

... More
code66 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 40mm nominal OD pipes, with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. (KPWD SR 2024-25 / VOL2/ Item No:13.31.5/Pg.No:122) ---- As per NIT and KW terms and conditions

50

552

27604

... More
code67 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming toIS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 32mm nominal OD pipes , with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:1.13.31.4/Pg.No:122) ---- As per NIT and KW terms and conditions

50

412

20600

... More
code68 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 25 mm nominal OD pipes , with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charge sand all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.31.3/Pg.No:122) ---- As per NIT and KW terms and conditions

80

327

26203.2

... More
code69 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 20mm nominal OD pipes ., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charge sand all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.31.2/Pg.No:122) ---- As per NIT and KW terms and conditions

50

249

12463

... More
code70 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.4.1/Pg.No:117) ---- As per NIT and KW terms and conditions

5

565

2827.35

... More
code71 - Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore, Horizontal, with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.6.1.1/Pg.No:117) ---- As per NIT and KW terms and conditions

5

638

3193

... More
code72 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern &C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Vol-2, P.No-131/14.3.1) etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.-W.C. pan with ISI marked white solid plastic seat and lid (KPWD SR 2024-25 / VOL2/ Item No:14.3.1/Pg.No:131) ---- As per NIT and KW terms and conditions

2

6156

12312.62

... More
code73 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps, with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. -White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (KPWD SR 2024-25 / VOL2/ Item No:14.7.1/Pg.No:132) ---- As per NIT and KW terms and conditions

2

3174

6348.92

... More
code74 - Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.(KPWD SR 2024-25 / VOL2/ Item No:14.22A/Pg.No:135) ---- As per NIT and KW terms and conditions

2

834

1668.6

... More
code75 - Providing and fixing 100 mm sand cast Iron grating for gully trap. etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:14.29/Pg.No:136) ---- As per NIT and KW terms and conditions

5

48

242.05

... More
code76 - Providing and fixing brass bib cock of approved quality : 20 mm nominal bore etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.2.2/Pg.No:117) ---- As per NIT and KW terms and conditions

5

314

1570.75

... More
code77 - Providing and fixing brass stop cock of approved quality : 20 mm nominal bore, with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL2/ Item No:13.3.2/Pg.No:117) ---- As per NIT and KW terms and conditions

5

314

1570.75

... More
code78 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ( KPWD SR 2024-25/VOL 2/Item 14.40.2/ Page No 137) ---- As per NIT and KW terms and conditions

2

510

1021.76

... More
code79 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. KPWD SR 2024-25 / VOL2/ Item No:14.31/Pg.No:136 ---- As per NIT and KW terms and conditions

2

1256

2513.2

... More
code80 - Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL5/ Item No:16.8 Pg.No:191) ---- As per NIT and KW terms and conditions

3

4934

14804.19

... More
code81 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover, with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.(KPWD SR 2024-25 / VOL5/ Item No: 16.9 Pg.No:191) ---- As per NIT and KW terms and conditions

3

5617

16852.86

... More
code82 - Providing and fixing PVC ( SWR) Nahani trap of approved make conforming to ISI specifications 10cms x 10 cms., Complete as per specification, all lead, lifts, curing and the directions of Engineer in-charge of the site. ( KPWD SR 2024-25/VOL 2/Item 13.59 Page 127) ---- As per NIT and KW terms and conditions

5

226

1133

... More
code83 - WARDROBE AND FURNISHING Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately)(KPWD SR 2024-25/Vol 2/Item No:22.3/Pg.No:217) ---- As per NIT and KW terms and conditions

75

3048

228660

... More
code84 - ELECTRICAL WORKS :- Concealed Conduit System -Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick, confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary-(KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.2.1 /Pg.No:2 -105) ---- As per NIT and KW terms and conditions

100

67

6798

... More
code85 - Concealed Conduit System -Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick,confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary- (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.2.2 /Pg.No:2 -105) ---- As per NIT and KW terms and conditions

150

80

12051

... More
code86 - Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.3.1 / Pg.No:2 -105) ---- As per NIT and KW terms and conditions

50

70

3502

... More
code87 - Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick -25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-. (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.3.2 / Pg.No:2 -105) . ---- As per NIT and KW terms and conditions

150

81

12205.5

... More
code88 - Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required. 20mm size- (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.8.1 / Pg.No:3 -105) . ---- As per NIT and KW terms and conditions

25

28

721

... More
code89 - Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required. 25mm size- (KPWD SR 2024-25 /Volume-6- part-3 / Item No:1.8.2 / Pg.No:3 -105) . ---- As per NIT and KW terms and conditions

25

36

901.25

... More
code90 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet.-Short point upto 3Mtr from tapping point to out let via switch . (KPWD SR 2024-25 /Volume-6- part-3 / Item No:2.2.1 / Pg.No:5 -105) ---- As per NIT and KW terms and conditions

4

277

1108.28

... More
code91 - Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. -Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.(KPWD SR 2024-25 / VOL6/ Item No:2.2.2 /Pg.No:5 of 105). ---- As per NIT and KW terms and conditions

10

390

3903.7

... More
code92 - Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.(KPWD SR 2024-25 / VOL6/ Item No:2.2.3 /Pg.No:5 of 105) ---- As per NIT and KW terms and conditions

41

571

23437.65

... More
code93 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches. .(KPWD SR 2024-25 / VOL6/ Item No:2.2.4 /Pg.No:5 of 105) ---- As per NIT and KW terms and conditions

2

697

1394.62

... More
code94 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box.(KPWD SR 2024-25 / VOL6/ Item No:2.2.5 /Pg.No:5 of 105) ---- As per NIT and KW terms and conditions

4

1018

4074.68

... More
code95 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/ C.C. wall 3 way .(KPWD SR 2024-25 / VOL6/ Item No:3.4.2 /Pg.No:8 of 105) ---- As per NIT and KW terms and conditions

50

163

8188.5

... More
code96 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 4-5 way .(KPWD SR 2024-25 / VOL6/ Item No:3.4.3 /Pg.No:8 of 105) ---- As per NIT and KW terms and conditions

50

182

9115.5

... More
code97 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 6way. (KPWD SR 2024-25 / VOL6/ Item No:3.4.4 /Pg.No:8 of 105) ---- As per NIT and KW terms and conditions

15

226

3399

... More
code98 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 8way. (KPWD SR 2024-25 / VOL6/ Item No:3.4.5 /Pg.No:8 of 105) ---- As per NIT and KW terms and conditions

15

268

4032.45

... More
code99 - supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 10-12way. (KPWD SR 2024-25 / VOL6/ Item No:3.4.6 /Pg.No:8 of 105) ---- As per NIT and KW terms and conditions

5

328

1642.85

... More
code100 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 3 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.2 /Pg.No:8 of 105) ---- As per NIT and KW terms and conditions

50

165

8291.5

... More
code101 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 4 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.3 /Pg.No: 8 of 105) ---- As per NIT and KW terms and conditions

50

180

9012.5

... More
code102 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 6 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.4 /Pg.No: 8 of 105) ---- As per NIT and KW terms and conditions

15

241

3615.3

... More
code103 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 8 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.5 /Pg.No: 8 of 105) ---- As per NIT and KW terms and conditions

15

292

4387.8

... More
code104 - Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 10-12 module. (KPWD SR 2024-25 / VOL6/ Item No:3.5.6 /Pg.No:8 of 105) ---- As per NIT and KW terms and conditions

5

354

1771.6

... More
code105 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. 6Amps one way Switch. (KPWD SR 2024-25 / VOL6/ Item No:3.6.1 /Pg.No: 9 of 105) ---- As per NIT and KW terms and conditions

71

105

7459.26

... More
code106 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293.- 6Amps two way Switch. (KPWD SR 2024-25 / VOL6/ Item No:3.6.2 /Pg.No:9 of 105) ---- As per NIT and KW terms and conditions

6

170

1025.88

... More
code107 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293.- 6Amps 3way socket. (KPWD SR 2024-25 / VOL6/ Item No:3.6.3 /Pg.No:9 of 105) ---- As per NIT and KW terms and conditions

55

176

9687.15

... More
code108 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. -Stepped Fan Regulator. (KPWD SR 2024-25 / VOL6/ Item No:3.6.4 /Pg.No: 9 of 105) ---- As per NIT and KW terms and conditions

13

367

4780.23

... More
code109 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. - 6/16Amps One way switch. (KPWD SR 2024-25 / VOL6/ Item No:3.6.7 /Pg.No: 9 of 105) ---- As per NIT and KW terms and conditions

32

185

5932.8

... More
code110 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. - 6/16Amps universal socket. (KPWD SR 2024-25 / VOL 6/ Item No:3.6.10 /Pg.No: 9 of 105). ---- As per NIT and KW terms and conditions

17

243

4132.36

... More
code111 - Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293.- RJ 45/I.O outlet cat -6. (KPWD SR 2024-25 / VOL6/ Item No:3.6.12 /Pg.No: 9 of 105) ---- As per NIT and KW terms and conditions

15

347

5206.65

... More
code112 - Supplying and drawing UTP-CAT 6E LAN cable. - (KPWD SR 2024-25 / VOL6/ Item No:8.1 /Pg.No: 36 of 105) ---- As per NIT and KW terms and conditions

350

39

13699

... More
code113 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments-1.5 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.2 /Pg.No: 5 of 105) ---- As per NIT and KW terms and conditions

1400

26

37492

... More
code114 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments- 2.5 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.3 /Pg.No: 5 of 105) ---- As per NIT and KW terms and conditions

1800

43

77868

... More
code115 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010confirming to latest amemndments-4 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.4 /Pg.No: 5 of 105) ---- As per NIT and KW terms and conditions

600

64

38934

... More
code116 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments- 6 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.5 /Pg.No: 5 of 105) ---- As per NIT and KW terms and conditions

40

94

3790.4

... More
code117 - Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments- 10 Sqmm. (KPWD SR 2024-25 / VOL6/ Item No:2.3.6 /Pg.No: 5 of 105) ---- As per NIT and KW terms and conditions

3

172

516.03

... More
code118 - FITTINGS - Supplying and fixing of 4' feet - PVC Batten with integrated LED tube 20/22.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (KPWD SR 2024-25 / VOL6/ Item No:11.3.2 /Pg.No: 43 of 105) ---- As per NIT and KW terms and conditions

30

710

21321

... More
code119 - Supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.-12" Sweep (300mm) (KPWD SR 2024-25 / VOL6/ Item No:6.2.1 /Pg.No: 30 of 105) ---- As per NIT and KW terms and conditions

2

3058

6116.14

... More
code120 - Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. (KPWD SR 2024-25 / VOL6/ Item No:13.13 /Pg.No: 57 of 105) ---- As per NIT and KW terms and conditions

2

728

1456.42

... More
code121 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. ( BLDC fans) (KPWD SR 2024-25 / VOL6/ Item No:6.4.1 /Pg.No: 30 of 105)- 48" sweep 5star (1200mm) ---- As per NIT and KW terms and conditions

8

2757

22058.48

... More
code122 - Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(KPWD SR 2024-25 / VOL6/ Item No:13.11 /Pg.No: 57 of 105) ---- As per NIT and KW terms and conditions

13

324

4217.85

... More
code123 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely.(KPWD SR 2024-25 / VOL6/ Item No:5.45.2/Pg.No: 21 of 105) ---- As per NIT and KW terms and conditions

7

1000

7000.91

... More
code124 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (KPWD SR 2024-25 / VOL6/ Item No:5.18.4 /Pg.No:17 of 105). ---- As per NIT and KW terms and conditions

7

761

5328.19

... More
code125 - Supply of round/square recess/surface mounted rolling type LED Down light with LED square or round down light 15-18W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working (KPWD SR 2024-25 / VOL6/ Item No:11.5.3/Pg.No:44 of 105) ---- As per NIT and KW terms and conditions

6

1363

8182.32

... More
code126 - CONSUMER CONTROL PANEL :- Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings. confirming to IS/IEC 60898 - 2. - 8way .(KPWD SR 2024-25 / VOL6/ Item No:5.17.2/Pg.No: 17 of 105) ---- As per NIT and KW terms and conditions

1

12983

12983.15

... More
code127 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.- 100A MCCB -25KA-4Pole. (KPWD SR 2024-25 / VOL6/ Item No:5.15.9/Pg.No:17 of 105) ---- As per NIT and KW terms and conditions

1

8741

8741.61

... More
code128 - Supplying and fixing Miniature Circuit Breakers in existing MCB distribution boards using necessary fixing material and C type curve, indicator ON/OFF, energy cross -3 with short circuit breaking capacity of 10k and complete wiring as required confirming to IEC60898. 63Amps TPN MCB .(KPWD SR 2024-25 / VOL6/ Item No:5.18.9 /Pg.No:18 of 105) ---- As per NIT and KW terms and conditions

5

3180

15903.2

... More
code129 - Supplying and fixing Miniature Circuit Breakers in existing MCB distribution boards using necessary fixing material and C type curve, indicator ON/OFF, energy cross -3 with short circuit breaking capacity of 10k and complete wiring as required confirming to IEC60898. 6-32A SP MCB. (KPWD SR 2024-25 / VOL6/ Item No:5.18.1 /Pg.No: 17 of 105) ---- As per NIT and KW terms and conditions

9

427

3847.05

... More
code130 - FLOOR WISE DB :- Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.- 8 way TP&N Double door DB . (KPWD SR 2024-25 / VOL6/ Item No:5.19.13 /Pg.No: 18 of 105) ---- As per NIT and KW terms and conditions

2

6273

12547.46

... More
code131 - Supplying, fixing and wiring Residual current Circuit Breaker ( RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. - 63A 4 pole. (KPWD SR 2024-25 / VOL6/ Item No:5.20.10 /Pg.No: 18 of 105) ---- As per NIT and KW terms and conditions

2

5711

11422.7

... More
code132 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ( 50-63A TPN MCB ). (KPWD SR 2024-25 / VOL6/ Item No:5.18.8 /Pg.No: 18 of 105) ---- As per NIT and KW terms and conditions

2

3180

6361.28

... More
code133 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ( 6-32A SP MCB ). (KPWD SR 2024-25 / VOL6/ Item No:5.18.1 /Pg.No: 17 of 105) ---- As per NIT and KW terms and conditions

40

427

17098

... More
code134 - UPS-DB :- Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.- 12way SP & N -UPS-DB(KPWD SR 2024-25 / VOL6/ Item No:5.19.9 /Pg.No:18 of 105) ---- As per NIT and KW terms and conditions

1

2398

2398.87

... More
code135 - Supplying, fixing and wiring Residaul current Circuit Breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board.( 32-40A 2 pole).(KPWD SR 2024-25 / VOL6/ Item No:5.20.4 /Pg.No:18 of 105) - UPS INCOMER ---- As per NIT and KW terms and conditions

1

4695

4695.77

... More
code136 - Supplying and fixing Miniature Circuit Breakers in existing MCB distribution boards using necessary fixing material and C type curve, indicator ON/OFF, energy cross -3 with short circuit breaking capacity of 10k and complete wiring as required confirming to IEC60898. 6-32A SP MCB. (KPWD SR 2024-25 / VOL6/ Item No:5.18.1 /Pg.No: 17 of 105) ---- As per NIT and KW terms and conditions

10

427

4274.5

... More
code137 - EB - METER BOARD :- Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.-600mm x 600mm x 170mm. (KPWD SR 2024-25 / VOL6/ Item No:5.44.4 /Pg.No:21 of 105) ---- As per NIT and KW terms and conditions

1

14955

14955.6

... More
code138 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.(KPWD SR 2024-25 / VOL6/ Item No:5.38 /Pg.No: 19 of 105) ---- As per NIT and KW terms and conditions

3

530

1591.35

... More
code139 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (KPWD SR 2024-25 / VOL6/ Item No:5.35 /Pg.No:19 of 105) ---- As per NIT and KW terms and conditions

1

5876

5876.15

... More
code140 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.-100A. (KPWD SR 2024-25 / VOL6/ Item No:5.7.4 /Pg.No:14 of 105) ---- As per NIT and KW terms and conditions

3

711

2135.19

... More
code141 - EARTHING:-Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (KPWD SR 2024-25 / VOL6/ Item No:12.56 /Pg.No:54 of 105) ( 2 for Bescom meter board + 1 for UPS DB) ---- As per NIT and KW terms and conditions

2

3615

7230.6

... More
code142 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.-25x3mm GI strip. (KPWD SR 2024-25 / VOL6/ Item No:12.58.2 /Pg.No: 54 of 105) ---- As per NIT and KW terms and conditions

100

84

8446

... More
code143 - Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor.(KPWD SR 2024-25 / VOL6/ Item No:5.37 /Pg.No: 19 of 105) - 10-kvar ---- As per NIT and KW terms and conditions

5

494

2472

... More
code144 - supplying and fixing metal fan box with round hook. (KPWD SR 2024-25 / VOL6/ Item No:1.13 /Pg.No: 4 of 105) ---- As per NIT and KW terms and conditions

13

120

1566.63

... More
code145 - TELEPHONE WORKS :- Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS 1293. TV/Telephone socket.(KPWD SR 2024-25 / VOL6/ Item No:3.6.11 /Pg.No: 9 of 105 ) ---- As per NIT and KW terms and conditions

15

160

2410.2

... More
code146 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 pair. (KPWD SR 2024-25 / VOL6/ Item No:8.2.2 /Pg.No: 36 of 105) ---- As per NIT and KW terms and conditions

325

21

7029.75

... More
code147 - Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 50 pair (KPWD SR 2024-25 / VOL6/ Item No:8.13.4 /Pg.No: 37 of 105) ---- As per NIT and KW terms and conditions

2

649

1299.86

... More
code148 - Supplying & Fixing of switch mounting rack with power manager & cable manager. 6U with 450 mm depth . (KPWD SR 2024-25 / VOL6/ Item No:8.4.2 /Pg.No: 36 of 105) ---- As per NIT and KW terms and conditions

1

7186

7186.31

... More
code149 - Supplying fixing of Network Switches - 24port 10/100 switch. (KPWD SR 2024-25 / VOL6/ Item No:8.9.5 /Pg.No: 36 of 105) ---- As per NIT and KW terms and conditions

1

4841

4841

... More
code150 - Supplying and Fixing of Patch panel for LAN cabling 24 port 10/100 patch panel. (KPWD SR 2024-25 / VOL6/ Item No:8.12.2 /Pg.No: 37 of 105) ---- As per NIT and KW terms and conditions

1

4223

4223



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.