Bangalore Development Authority Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Bangalore Development Authority Tender

Works
Energy, Oil and Gas
Electrical and Electronics
Electrical Works
Opening Date7 Apr 2025
Closing Date22 Apr 2025
Tender Amount₹ 88,13,99,530.93 
Notes
Download

AI Insights

Work Experience Requirements
... View More
The required prior work experience for the bidder includes executing works of a similar nature. The experience requirements are based on the maximum value of electrical works executed in any one year during the last five years. The bidder needs to demonstrate prior work experience in executing electrical works, specifically EHV UG Cable & Cable Accessories, with a manufacturing experience of Five (5) years for the equipment manufacturer and satisfactory service of 2 years for the equipment manufacturer. The bidder should provide details of quantities of work executed during the last 10 years for EHV UG cable and Tower works. The monetary values mentioned include Rs 2203.50 Lakhs, which is 25% of the Amount Put to Tender, as the required liquid assets and/or availability of credit facilities. The bidder should also upload audited financial statements for the last five years. No specific percentage of similar works completed is mentioned, but the bidder's assessed available tender capacity is calculated based on the maximum value of electrical works executed, the number of years prescribed for completion, and the value of existing commitments and ongoing works.
Class Of Bidder
... View More
Super Grade Electrical Contractor’s License
Bid Capacity
... View More
The formula for bid capacity, also referred to as "Assessed available tender capacity", is: Assessed available tender capacity = (A*N*1.5 - B) Where: A = Maximum value of electrical works executed in any one year during the last five years, taking into account the completed as well as works in progress. B = Value, at the current price level, of existing commitments electrical works and on-going works electrical works to be completed during the next 1½ Years. N = Number of years prescribed for completion of the works for which tenders are invited.

Costs

Summary

Establishing 2x31.5mva, 66/11kv Sub-station Along With Supply & Laying Of 66kv Voltage Class 1000sqmm Ehv Ug Cable For Regular Source From The Kptcl Proposed Gis Substation

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
ele4 - Circuit Breaker : Sf6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting Structures arrangements with rigid, bi-metallic terminal connectors complete suitable for Drake ACSR conductor and mounting structures. 66KV, 1250A, 40KA Class a. for 66kV Line -2Nos b. for 66kV transformer - 2Nos (UNISR 2023-24, Vol-6, Pg No.27 SL No.3.4, Pg no116-117, SL No. 13)

5

755735

3778678.75

... More
ele5 - Erection Charges for the 66KV, 1250A, 40KA Class Sf6 Circuit Breaker

5

9300

46504.5

... More
ele6 - testing and Commissioning Charges for the 66KV, 1250A, 40KA Class Sf6 Circuit Breaker

5

45472

227362.5

... More
ele7 - Isolators : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators: A) 66KV, 1250A, 31.5KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSR. (UNISR 2023-24, Vol-6, Pg No.37 SL No.9.13, Pg no119, SL No. 17 a) Upright mounting type with earth switch (Live point height 4600mm)

3

299172

897517.5

... More
ele8 - Erection Charges for the Isolators

3

4614

13844.94

... More
ele9 - testing and Commissioning Charges for the Isolators

3

887

2663.85

... More
ele10 - Isolators : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators: A) 66KV, 1250A, 31.5KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSR. (UNISR 2023-24, Vol-6, Pg No.37 SL No.9.13, Pg no119, SL No. 17 b) Upright mounting type without earth switch. (Live point height 6300mm)

6

258849

1553095.5

... More
ele11 - Erection Charges for the Isolators

6

4614

27689.88

... More
ele12 - testing and Commissioning Charges for the Isolators

6

887

5327.7

... More
ele13 - B) 11 KV ISOtAORS 11kV isolators, Double Break 400A, 25kA capacity, with rigid bi-metallic terminal connectors suitable for coyote ACSR for outgoing feeders/capacitor bank. (15Nos for feeders + 4Nos for Cap.Bank) (ESCOMSR 2023-24, Vol-6, Pg No.11 SL No.169, Pg No.48, slno.98)

4

22854

91418

... More
ele14 - Erection Charges for the Isolators

4

1305

5220.2

... More
ele15 - CURRENt transformer: Current transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR conductor. (UNISR 2023-24, Vol-6, Pg No.31 SL No.5.2, Pg no118, SL No. 14,15)66KV class, 31.5KA, C.t of ratio: i) 66 kV class, 40KA, Ct of ratio 1200-800 / 1-1-1 A for Lines Core-1:Purpose - Dist/Dif, Acc Class -PS, Vk -1400, Rct: 5 Ohm at 800/1A. Core-2:Purpose- Metering, Acc Class - 0.2S, Burden-10VA Core-3:Purpose-Back up, Acc Class-5P20, Burden-30VA.

9

143082

1287742.5

... More
ele16 - Erection charges for the Current transformers of 66 kV class, 40KA, Ct of ratio 1200-800 / 1-1-1 A for Lines

9

1617

14560.92

... More
ele17 - testing and Commissioning charges for the Current transformers of 66 kV class, 40KA, Ct of ratio 1200-800 / 1-1-1 A for Lines

9

5052

45475.74

... More
ele18 - CURRENt transformer: Current transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR conductor. (UNISR 2023-24, Vol-6, Pg No.31 SL No.5.2, Pg no118, SL No. 14,15)66KV class, 31.5KA, C.t of ratio: ii) 66 kV class, 40 KA, Ct of ratio 400-200 / 1-1-1A for transformer Core-1:Purpose - Dist/Dif, Acc Class -PS, Vk -1600, Rct: 4 Ohm at 400/1A. Core-2:Purpose- Metering, Acc Class - 0.2S, Burden-10VA Core-3:Purpose-Back up, Acc Class-5P20, Burden-30VA.

6

105360

632164.5

... More
ele19 - Erection charges for the Current transformers of 66 kV class, 40 KA, Ct of ratio 400-200 / 1-1-1A

6

1617

9707.28

... More
ele20 - testing and Commissioning for the Current transformers of 66 kV class, 40 KA, Ct of ratio 400-200 / 1-1-1A

6

5052

30317.16

... More
ele21 - iii) 11 kV class, 25 KA, NCt of ratio 2000-1200/1-1A for REfR protection (of similar rating and ratio as that of incomer of 11KV switch gear) with terminal connector suitable for 2Nos of 100x8mm copper flats.

2

45526

91052.5

... More
ele22 - Erection charges for the Current transformers of 11 kV class, 25 KA, NCt of ratio 2000-1200/1-1A

2

787

1575.96

... More
ele23 - testing and Commissioning charges for the Current transformers of 11 kV class, 25 KA, NCt of ratio 2000-1200/1-1A

2

4885

9771.76

... More
ele24 - Voltage transformers: 66KV single phase, oil filled with Out door type including Marshalling KIOSK with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specification. Ratio: 66KV/sqrt3/110V/sqrt3-110V/sqrt3-110 V/sqrt3. Core-1:Purpose - Metering, Acc Class -0.2, Burden:-300VA. Core-2:Purpose- Protection, Acc Class - 3P, Burden-200VA Core-3:Purpose-Open/Delta, Acc Class-3P, Burden-50VA. (UNISR 2023-24, Vol-6, Pg No.33 SL No.7.3, Pg no118, SL No. 14)

3

106661

319984.5

... More
ele25 - Erection charges for the Voltage transformers: of 11 kV class, Ratio: 66KV/sqrt3/110V/sqrt3-110V/sqrt3-110 V/sqrt3

3

1617

4853.64

... More
ele26 - testing and Commissioning charges for the Voltage transformers: of 11 kV class, Ratio: 66KV/sqrt3/110V/sqrt3-110V/sqrt3-110 V/sqrt3

3

5087

15261.78

... More
ele27 - Surger Arrestors (Porcelain Housing) metal Oxide Gap less type as per technical Specification with terminal connector suitable for vertical and horizontal take off: 1) 60 kV, 10 kA, class - II for transformers

6

33819

202917

... More
ele28 - Erection charges for the surge Arrestors

6

262

1575.96

... More
ele29 - Surger Arrestors (Porcelain Housing) metal Oxide Gap less type as per technical Specification with terminal connector suitable for vertical and horizontal take off: 2) 60 kV, 10 kA, class - III for line

9

36421

327789

... More
ele30 - testing and Commissioning charges for the surge Arrestors

9

262

2363.94

... More
ele31 - Surger Arrestors (Porcelain Housing) metal Oxide Gap less type as per technical Specification with terminal connector suitable for vertical and horizontal take off: 3) 9KV, 10kA Class (ESCOM SR Vol-6 Pg.No.9 Sl.no.137 and Pg.No.48 Sl.No.101)

45

989

44505

... More
ele32 - testing and Commissioning charges for the surge Arrestors

45

42

1918.8

... More
ele33 - Control and Relay panels: Simplex type control and relay panel complete as per specifications: with SCADA campatability. (UNISR 2023-24, Vol-6, Pg No.41 SL No.16.2, Pg no118, SL No. 14) a)for Power transformer 66/11 kV

2

688096

1376193.5

... More
ele34 - Erection charges for the Control and Relay panels for Power transformer 66/11kV

2

4505

9010.66

... More
ele35 - testing and Commissioning charges for the Control and Relay panels for Power transformer 66/11kV

2

46195

92391.96

... More
ele36 - Control and Relay panels: Simplex type control and relay panel complete as per specifications: with SCADA campatability. (UNISR 2023-24, Vol-6, Pg No.41 SL No.16.2, Pg no118, SL No. 14) b)for 66kV transmission line with differential protection.

3

490382

1471148.25

... More
ele37 - Erection charges for the Control and Relay panels 66kV transmission line with differential protection.

3

4505

13515.99

... More
ele38 - testing and Commissioning charges for the Control and Relay 66kV transmission line with differential protection.

3

46195

138587.94

... More
ele39 - B. 11KV ODS and take off structure i) Supplying and Erection of D.P. Structure using 9.0 Mtr long, 145Kg WL suitable for mounting GOS along with all accessories. (12Nos for feeders) (ESCOM SR Vol-6 Pg.No.9 Sl.no.142 and Pg.No.44 Sl.No.38)

12

18707

224485.8

... More
ele40 - Erection Chargers for the 11KV ODS and take off structure

12

6154

73852.56

... More
ele41 - GI Mounting Structures including bolts and nuts (Lattice type) (UNISR 2023-24, Vol-6, Pg No.43 SL No.18, Pg no113, SL No. 1.1.c) i) 66 kV Isolator Live point height 4600 mm

3

77581

232745.79

... More
ele42 - Erection Chargers

3

6152

18456.69

... More
ele43 - GI Mounting Structures including bolts and nuts (Lattice type) (UNISR 2023-24, Vol-6, Pg No.43 SL No.18, Pg no113, SL No. 1.1.c) ii) 66 kV Isolator Live point height 6350mm

6

89390

536340.84

... More
ele44 - Erection Chargers

6

6152

36913.38

... More
ele45 - GI Mounting Structures including bolts and nuts (Lattice type) (UNISR 2023-24, Vol-6, Pg No.43 SL No.18, Pg no113, SL No. 1.1.c) iii)66KV Current transformers and 11kV NCt ( 0.158Mt per Struct)

17

23111

392899.41

... More
ele46 - Erection Chargers

17

6152

104587.91

... More
ele47 - GI Mounting Structures including bolts and nuts (Lattice type) (UNISR 2023-24, Vol-6, Pg No.43 SL No.18, Pg no113, SL No. 1.1.c) iv)66KV Potential transformers ( 0.148Mt per Strcut)

3

21647

64941.24

... More
ele48 - Erection Chargers

3

6152

18456.69

... More
ele49 - GI Mounting Structures including bolts and nuts (Lattice type) (UNISR 2023-24, Vol-6, Pg No.43 SL No.18, Pg no113, SL No. 1.1.c) v)66KV Lightening arrestors ( 0.116Mt per Struct)

9

16985

152866.71

... More
ele50 - Erection Chargers

9

6152

55370.07

... More
ele51 - GI Mounting Structures including bolts and nuts (Lattice type) (UNISR 2023-24, Vol-6, Pg No.43 SL No.18, Pg no113, SL No. 1.1.c) vi) Combined mounting structure for 66kV cable and 60kV surge arrestor (0.224 Mt per structure)

9

32687

294190.65

... More
ele52 - Erection Chargers

9

6152

55370.07

... More
ele53 - v) 66kV Pedestal Insulators a) for 66KV pedestal Insulators for Bus (0.140Mt per Struct)

12

20497

245966.64

... More
ele54 - Erection Chargers

12

6152

73826.76

... More
ele55 - b) 66KV High Pedestal Insulator for transformer (0.150Mt per Struct)

6

21977

131864.82

... More
ele56 - Erection Chargers

6

6152

36913.38

... More
ele57 - vi) 11kV Cable terminating Structure for LV side of transformer (0.072Mt per Struct)

2

10512

21025.32

... More
ele58 - Erection Chargers

2

6152

12304.46

... More
ele59 - vii) 11kV Cable Support Structure for Capacitor Bank. (0.072Mt per Struct)

4

10512

42050.64

... More
ele60 - Erection Chargers

4

6152

24608.92

... More
ele61 - A) Bus Bar formation: (UNISR 2023-24, Vol-6, Pg No.44 SL No.20, Pg no114, SL No. 4) a) Drake ACSR

0.05

416025

20801.25

... More
ele62 - A) Bus Bar formation: (UNISR 2023-24, Vol-6, Pg No.44 SL No.20, Pg no114, SL No. 4) b) Coyote ACSR

0.15

149425

22413.75

... More
ele63 - d) formation of main/cross bus (all the three phases in a segment) using falcon/Drake/Lynx/Coyote- Single/double conductors with fixing of insulator spacers, leveling of string conductors to the required height above the equipments, including providing jumps to interconnect different segments of the main bus.

4

12993

51974.12

... More
ele64 - Rigid bus with taps and Clamps: Aluminium pipe confirming to 6340 WP of IS -5082 /1969 (BS 1600-Sch-40 of following nominal diameter a) 63 mm 66 kV main bus

96

1560

149846.4

... More
ele65 - Rigid bus with taps and Clamps: Aluminium pipe confirming to 6340 WP of IS -5082 /1969 (BS 1600-Sch-40 of following nominal diameter b) 50 mm size connecting isolator to vertical tap and also for connecting equipments to equipments 66 kV side.

300

1320

396030

... More
ele66 - a) straight taps suitable for 50 mm Aluminium tube (BS 1600) of 1250 mm vertical height for vertical portion and cross bus on 66 kV side with rounded off end.

6

2515

15093

... More
ele67 - Post insulators clamps suitable for 63 mm Aluminium pipe and post insulator solid core type- 66 kV side. Rigid type

6

1884

11306.88

... More
ele68 - Post insulators clamps suitable for 63 mm Aluminium pipe and post insulator solid core type- 66 kV side. Expansion type

3

5319

15957.3

... More
ele69 - Sliding type

3

1592

4776.24

... More
ele70 - Corona bell suitable for Aluminium pipe of size 63mm on 66 kV side

6

663

3979.68

... More
ele71 - flexible type terminal connector suitable for 50 mm Aluminium pipe to connect bus isolator.

54

4780

258148.62

... More
ele72 - flexible type terminal connector suitable for 63 mm Aluminium pipe to connect bus isolator.

3

5319

15957.3

... More
ele73 - End caps suitable for 50mm Al tube

3

527

1583.49

... More
ele74 - i. Post Insulators -Cylindrical solid Core as per 1S5350, Part II and III (UNISR 2023-24, Vol-6, Pg No.45 SL No.21.1.4, Pg no119, SL No. 19) a. 66kV Class, 1 Unit/stack

18

5841

105147.9

... More
ele75 - Erection Charges

18

262

4721.4

... More
ele76 - Post insulator clamp suitable for Single Drake ACSR and 66kV Solid Core Insulator. (UNISR 2023-24, Vol-6, Pg No.69 SL No.47.5.5)

6

1085

6514.5

... More
ele77 - Auxiliary transformer: Supply and erection of station Auxiliary transformer with oil, outdoor type 100KVA, 11KV/433V, 3Ph, Vector Group Dyn11, off load tap changer (with 5 taps) with step voltage of 2.5%, along with DOLO/HG-fuse Unit, L.t. protection Kit, Distribution Box, and other accessories as per specification. (UNISR 2023-24, Vol-6, Pg No.75 SL No.56.3)

1

375385

375385.7

... More
ele78 - Erection Charges

1

19986

19986.4

... More
ele79 - A) LtAC Panel (indoor): 415V, as per technical specification comprising of Volt Meter, Ammeter and 1 No. EtV meter. 1No. I/C MCCB 200A + 2Nos. 3 phase, 63A OG HRC fuse + 2Nos. 3 phase, 32A OG HRC fuse + 6Nos. 3 phase, 16A HRC fuse etc., complete. (UNISR 2023-24, Vol-6, Pg No.39 SL No.11.2.2, Pgno.121 Slno 23.h)

1

92353

92353.25

... More
ele80 - Erection Charges

1

3447

3447.53

... More
ele81 - B) A.C. Distribution Box (Outdoor) : AC disrtibution box single front type, 6 terminals, 750x1350x300 mm, 1 I/C of 100A, MCCB 20KA + 6 O/G MCB 16A + 1 O/G of 100A , HRC fuse (UNISR 2023-24, Vol-6, Pg No.39 SL No.11.2.1, Pgno.121 Slno 23.h)

2

78045

156090

... More
ele82 - Erection Charges

2

3447

6895.06

... More
ele83 - Lt Power armoured UG cable as per specifications: (ESCOM SR Vol-6, Pg No. 13 item No 32 , Pgno52, sl No 174 and 175) a) 1.1KV PVC insulated 95sq mm aluminum Cable, 4 core with glands/lugs / ferrules. (SL No. 175)

200

401

80242

... More
ele84 - Erection Charges

200

33

6694

... More
ele85 - b) 1.1 KV PVC insulated 25 sq mm Copper cable 4 core with glands/lugs/ferrules. (SL No. 174)

50

193

9666.5

... More
ele86 - Erection Charges

50

22

1122.5

... More
ele87 - c) 1.1 KV PVC insulated 10 Sq mm Copper Cable 4 core with glands/lugs/feerules. (SL No. 174)

50

126

6342.5

... More
ele88 - Erection Charges

50

22

1122.5

... More
ele89 - Station Battery and Charger: i) 110V, 100AH Battery set consists of 55 Nos. of cells with accessories as per specification. (rate considered for 110V, 200AH) (UNISR 2023-24, Vol-6, Pg No.37 SL No.10.1.5, Pgno.124 Slno 28.a.ii)

1

649083

649083.93

... More
ele90 - Erection Charges

1

12492

12492.58

... More
ele91 - ii) Battery charger suitable for 110V, 100AH, Battery set consisting of 55 No. cells with float Cum Booster type battery charger as per specification (UNISR 2023-24, Vol-6, Pg No.38 SL No.10.2.4, Pgno.125 Slno 28.b,28.c)

1

182105

182105

... More
ele92 - Erection Charges

1

1233

1233.03

... More
ele93 - testing and Commissioning Charges

1

32797

32797.18

... More
ele94 - DC Distribution Panel (Indoor type) as per technical specification comprising of Earth fault indicator, Indication circuit for AC main failure, 1 No. 100A SfU for IC + 12 Nos., 32A SfU for OG etc., complete. (UNISR 2023-24, Vol-6, Pg No.39 SL No.11.2.3, Pgno.121 Slno 23.h)

1

55932

55932.25

... More
ele95 - Erection Charges

1

2650

2650.95

... More
ele96 - Copper Control cables: 11.1kV class PVC insulated Copper Control Cable with Lugs/ferrules/ Glands as per technical specifications. (UNISR 2023-24, Vol-6, Pg No.40 SL No.13, Pgno.120 Slno 22) i. 19C x 2.5 Sq mm (Item-1.12.16)

8000

564

4515040

... More
ele97 - Erection Charges

8000

16

129040

... More
ele98 - Copper Control cables: 11.1kV class PVC insulated Copper Control Cable with Lugs/ferrules/ Glands as per technical specifications. (UNISR 2023-24, Vol-6, Pg No.40 SL No.13, Pgno.120 Slno 22) ii. 4C x 6.0 sq mm (Item-1.12.8)

3500

265

929355

... More
ele99 - Erection Charges

3500

16

56455

... More
ele100 - Copper Control cables: 11.1kV class PVC insulated Copper Control Cable with Lugs/ferrules/ Glands as per technical specifications. (UNISR 2023-24, Vol-6, Pg No.40 SL No.13, Pgno.120 Slno 22) iii 4C x 2.5 Sqmm (Item-1.12.6)

4500

152

686925

... More
ele101 - Erection Charges

4500

16

72585

... More
ele102 - Copper Control cables: 11.1kV class PVC insulated Copper Control Cable with Lugs/ferrules/ Glands as per technical specifications. (UNISR 2023-24, Vol-6, Pg No.40 SL No.13, Pgno.120 Slno 22) iv. 4 x 4 sq mm (Item-1.12.1)

2500

190

475700

... More
ele103 - Erection Charges

2500

16

40325

... More
ele104 - Copper Control cables: 11.1kV class PVC insulated Copper Control Cable with Lugs/ferrules/ Glands as per technical specifications. (UNISR 2023-24, Vol-6, Pg No.40 SL No.13, Pgno.120 Slno 22) v. 10 x 2.5 sqmm

2500

336

841200

... More
ele105 - 11KV SwitchGear

2500

16

40325

... More
ele106 - 11kV, 500 MVA, Metal Clad VCB Switchgear (2000A for Incomer and 1600A for feeders), outdoor type, each comprising of 2IC+16f+1BC+4CB+1AP (Remote Announciation cum Control panel) with Cts and Pts and terminal connectors suitable for Drake/ Coyote ACSR etc., complete as per technical specification. Note: 1. the switchgear for capacitor bank shall have necessary over volatge/under volatge/ circulating current relays and other protection relays as per specification. 2. the remote announciation cum control panel is simplex type. 3. the Electronic trivector meters with ABt features has to be provided. 4. the switchgear will be supplied by KPtCL and the bidder has to quote for complete scope of erection of switchgear including moving the switchgear from the point of unloading to the point of erection, erection of the complete switch gear, wiring of switchgear, testing and commissioning etc., complete

1

30319181

30319181.75

... More
ele107 - Erection Charges

1

53689

53689.8

... More
ele108 - testing and Commissioning Charges

1

207414

207414.8

... More
ele109 - CAPACItOR BANK: Design, Engineering, supply, erection (including civil works), testing and commissioning of 5.8 MVAR, 12.1kV capacitor bank, star connected double bank with internal fuses, terminal connectors with suitable neutral Ct and station class LA's, 0.2%, series reactor with mounting structures for NCt, Capacitor Bank, station Class LA's, series reactor, cable termination, isolator, etc., complete as per specification(including testing andcommissioning). Note: the 11KV switchgear and remote announciation /control of the Capacitor Bank is included in item no.A19.

4

1229208

4916835

... More
ele110 - 11 kV UG cable with the required cable terminations at both ends. a) One run of 11 kV, XLPE 95 sq mm Al. 3 core cable - (to be run for Auxillary transformers from 11 kV switch gear to auxillary transformer).

50

956

47819.5

... More
ele111 - Laying Charges

50

77

3870

... More
ele112 - b) 11 kV, XLPE cable, 1000 sq mm, (3 Runs of 1CX1000 sq mm) Aluminium cable from 66/11 kV transformers to 11 kV switchgear.

500

1273

636940

... More
ele113 - Laying Charges

500

77

38700

... More
ele114 - c) 11 kV XLPE cable, 400 sq mm aluminium cable 3 core to be run from 11 kV switchgear to 11 kV take off DP structure and switchgear to capacitor bank

700

2683

1878590

... More
ele115 - Laying Charges

700

77

54180

... More
ele116 - d) Cable termination Kits suitable for following sizes as per technical Specifcation: i. 95Sq.mm 3 Core ia. Indoor (ESCOM SR 2023-24, Vol-6, Pg No.20 SL No.346 , Pg No.52 SL No.182)

1

4024

4024.8

... More
ele117 - Making Charges

1

2857

2857.35

... More
ele118 - d) Cable termination Kits suitable for following sizes as per technical Specifcation: i. 95Sq.mm 3 Core ib. Outdoor (ESCOM SR 2023-24, Vol-6, Pg No.20 SL No.349 , Pg No.52 SL No.182)

1

4372

4372.03

... More
ele119 - Making Charges

1

2857

2857.35

... More
ele120 - ii. Cable termination Kits suitable for1000Sq.mm Single Core iia. Indoor (UNISR 2023-24, Vol-6, Pg No.73 SL No.50.3.1, Pgno.120 Slno 22.e.ii)

18

4093

73684.8

... More
ele121 - Making Charges

18

4033

72601.2

... More
ele122 - ii.Cable termination Kits suitable for 1000Sq.mm Single Core iib. Outdoor (UNISR 2023-24, Vol-6, Pg No.73 SL No.50.3.2, Pgno.120 Slno 22.e.ii)

18

4364

78561

... More
ele123 - Making Charges

18

4033

72601.2

... More
ele124 - iii) 400Sq mm three core Cable termination Kit iia. Indoor (ESCOM SR 2023-24, Vol-6, Pg No.20 SL No.348, Pg No.52 SL No.184) (15Nos for feeders + 4Nos for Cap.Bank)

19

5176

98346.47

... More
ele125 - Erection Charges

19

2857

54289.65

... More
ele126 - Cable termination Kit iib. Outdoor (ESCOM SR 2023-24, Vol-6, Pg No.20 SL No.351, Pg No.52 SL No.184) (15Nos for feeders + 4Nos for Cap.Bank)

19

5759

109437.15

... More
ele127 - Erection Charges

19

2857

54289.65

... More
ele128 - Equipments required for establishing SCADA Communicaton as per KPtCL Specification. a) Remote terminal Unit (RtU)

1

1060111

1060111.25

... More
ele129 - b) Data Concentrator Unit(DCU)

1

40323

40323.25

... More
ele130 - c)2 kVA online UPS (230 V AC 1 phase 50 hz)

1

180804

180804.25

... More
ele131 - Supply of power cables for SCADA:- a) Current cable-Copper core with 4 Sqmm, cross section multistrand 7 core for Ct termination (approximately 20 Mtr)

20

320

6407

... More
ele132 - b) Voltage cable-Copper core with 2.5 Sqmm cross section multistrand 4 Core for Pt termination (approximately 20 Mtr)

20

152

3053

... More
ele133 - Supply of Control Cables for SCADA a) Signal cables -Armoured Copper core with 0.5 sq mm cross section, Multistrand. 10 core (Approximately 500 Mtr).

100

153

15373

... More
ele134 - b)Control cables-Copper core with 1.5 Sqmm cross section Multistrand, 10 core. (Approximately 160 Mtr).

100

166

16663

... More
ele135 - c) Cables-Copper core with 4 Sq. mm cross section Multistrand 3 core for AC input to UPS and UPS to RtU confirming to KPtCL specifications (Approximately 15 Mtr).

15

170

2563.95

... More
ele136 - d) Cables - copper core with 16 sq mm cross section multistrand for Battery (Approximately 15 Mtr X 2 runs).

30

408

12255

... More
ele137 - j) Site Survey, wiring installation. testing and Commissioning of RtU, DCU, DCU Installation to be done in RtU Panel (UNISR 2023-24, Vol-6, Pg No.128 SL No.29.I.a,b)

1

40515

40515.68

... More
ele138 - k) Integration of RtU, DCU, UPS with filed equipments. (UNISR 2023-24, Vol-6, Pg No.128 SL No.29.I.c,d)

1

98744

98744.13

... More
ele139 - fIRE fIGHtING EQUIPMENtS WItH NECESSARY MOUNtING StANDS: (UNISR 2023-24, Vol-6, Pg No.74 SL No.51) i)Mechanical foam type extinguisher 50 Ltr. Capacity.

4

10870

43481.6

... More
ele140 - ii) Mechanical foam type extinguisher 9.0 Ltr. Capacity.

4

4426

17707.4

... More
ele141 - Water type (gas presuure type) 9 Ltr. Capacity

6

2690

16144.38

... More
ele142 - Carbon di-oxide type 4.5Kg Ltr. Capacity

6

9342

56056.98

... More
ele143 - i)Sand type G.I Buckets 15 Ltr. Capacity

12

648

7778.76

... More
ele144 - ii) Steel stands for above to have 4 buckets to each section.

3

2539

7617.45

... More
ele145 - ii)Supply, Erection and Commissioning of Nitrogen Injection fire extinguishing system including Civil Engineering works like soak pit etc., as per the recommendations of the supplier of the fire fighting system.(for 2x31.5MVA)

2

1227257

2454515.26

... More
ele146 - MISCELLANEOUS ItEMS: Like Rubber mats, first aid box, danger boards, shock treatment charts, water filter, door locks, fixograph, sub-station name board and other sundry items (sizes/capacities to be got approved). (Rates as per approved DPR of 220/66/11kV Nelamangala GIS sub-station Rubber mats 2000 mm x 1000 mm x 12 mm size tested for15V class

20

2042

40850

... More
ele147 - first aid box

1

645

645

... More
ele148 - Shock treatment charts, hard board, liminated with coloured pictures and literature both in Kannada and English.

1

2150

2150

... More
ele149 - Water filter/ Water purifier: Wall mounting type (Aquaguard type).

1

10750

10750

... More
ele150 - Sub-station name board duly painted as per specification including erection and Civil Works.

1

9675

9675

... More
ele151 - fixograph of size 1.5 m x 2.5 with English/ Kannada alphabets.

1

5375

5375

... More
ele152 - Door locks 7 levers (Navtal make ) (Sizes and capacities to be got approved)

5

537

2687.5

... More
ele153 - Danger Board(prohibited) with support structure including fixing in front of the gate.

1

2150

2150

... More
ele154 - Euipments name plates and earthing name plates including fixing at outdoor yard

75

341

25638.75

... More
ele155 - MAINtENANCE tOOLS AND PLANtS: (UNISR 2023-24, Vol-6, Pg No.53,54,55 SL No.35) a) Portable (Mobile) Oil Pump (0.5 HP Air Pump 500 to 1000 Gallons)

1

21765

21765.53

... More
ele156 - b) telescopic Ladder Aluminium 6 Mtr. Height

1

24318

24318.65

... More
ele157 - c) Ring Spanner

1

946

946

... More
ele158 - d) tube spanner set

1

1542

1542.63

... More
ele159 - e) Pipe wrench 24 inch.

2

1343

2687.5

... More
ele160 - f) Pipe Wrench 18 Inch

2

743

1487.8

... More
ele161 - g) Hydraulic Crimpping tools up to 1000 Sq.mm

1

66663

66663.98

... More
ele162 - h) Rubber Hand Gloves (15KV tested)

3

314

944.94

... More
ele163 - i) Hand torch

2

1290

2580

... More
ele164 - i. five Cells (Rechargeble 5W LED Hand torch rate considered)

2

1374

2749.86

... More
ele165 - ii. three Cells

2

1374

2749.86

... More
ele166 - j) Insulated Cutting Plier.

4

449

1797.4

... More
ele167 - i. 12inch Size

3

422

1267.44

... More
ele168 - ii. 8inch Size

3

253

761.1

... More
ele169 - k) Line Live tester

2

334

668.66

... More
ele170 - l) Screw Driver 18 Inch

3

239

719.19

... More
ele171 - m) Screw Driver 12 Inch

3

80

241.89

... More
ele172 - n) Hammer 8 Ibs

2

534

1068.56

... More
ele173 - o) Hammer 2 Ibs

2

267

535.36

... More
ele174 - p) Chain Pulley Block 5 ton

1

44973

44973.7

... More
ele175 - q) Hydraulic Jack 5 ton

4

7576

30306.4

... More
ele176 - r) Pipe Derrick

1

29918

29918.33

... More
ele177 - s) Allen Keys

1

513

513.85

... More
ele178 - t) Box Spanners

1

4802

4802.03

... More
ele179 - u) transil Oil Dielectric Breakdown test Kit

1

109150

109150.13

... More
ele180 - Insulation-Megger- 2.5 - 5KV (Insulation tester Digital type)

1

59456

59456.1

... More
ele181 - w) Insulation Megger 500V

1

18926

18926.45

... More
ele182 - x) Sf-6 Gas Leak Detector

1

70135

70135.15

... More
ele183 - y) Multimeter Electromechanical type

1

3949

3949.55

... More
ele184 - z) Multimeter Electronic type

1

8590

8590.33

... More
ele185 - aa) Hydro Meter

1

707

707.35

... More
ele186 - bb) DC Volt Meter Range -5V to +5V

1

2902

2902.5

... More
ele187 - cc) Hydrometer Syringe suitable for vent holes

1

967

967.5

... More
ele188 - dd) Specific gravity correction Chart

1

967

967.5

... More
ele189 - ee) Wall mounting type holder for hydrometer

1

2902

2902.5

... More
ele190 - ff) thermometer with wall mounting holder.

1

2902

2902.5

... More
ele191 - gg) Rubber Appron

1

2055

2055.4

... More
ele192 - hh) Pipette

1

847

847.1

... More
ele193 - ii) Protective Gaggle

1

967

967.5

... More
ele194 - jj) Acid Resisting Jars (4 Pint - Capacity)

1

967

967.5

... More
ele195 - kk) Rubber Shoes Knee Height

2

2298

4596.7

... More
ele196 - ll) Glass funnel

2

726

1453.4

... More
ele197 - jj) Grounding sticks

6

1886

11319.78

... More
ele198 - furniture for control room staff and maintenance staff: (Rates as per approved DPR of 220/66/11kV Nelamangala GIS sub-station) a) Steel Almirahs 60.5 feet

2

8600

17200

... More
ele199 - b) Steel Almirahs 6 0.5 feet with glass panel doors

1

8600

8600

... More
ele200 - c) Officer’s tables

2

6880

13760

... More
ele201 - d) Steel Slotted angle rack (Big Size)

4

2365

9460

... More
ele202 - e) Steel Slotted angle rack (small Size)

4

1505

6020

... More
ele203 - f) Steel Dust Bins

4

430

1720

... More
ele204 - g) Executive Revolving Chairs

2

7525

15050

... More
ele205 - h) S type Arm Chairs

6

1935

11610

... More
ele206 - i) Steel folding Chairs

4

1182

4730

... More
ele207 - Station yard lighting (outdoor): Design of Station Yard illumination in Confirmity with the illumination levels mentioned in the technical Specification, Supply and erection of Station Yard illumination materials / equipments including lamp post (fabricated Galvanised structures), Illumination fittings, Control Gear, UG/OH cables, Conduit Pipes, Control Boxes, etc., including necessary Civil works, complete for the following Sub-Station Supplying of tubular type Lighting / lighting Mast (approx wt. 2.678 t)

2

410693

821387.72

... More
ele208 - Labour Charges for the Erection

5.6238

6152

34598.911074

... More
ele209 - Supplying and fixing of LED Streetlight luminaire/Yard lighting with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCt greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 120W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/Lumileds/Osram make LED Source. 120Watts

16

4325

69212.8

... More
ele210 - EARtH MAt fORMAtION a) Supplying and laying of MS flat 75*12 mm flat welding and applying ACB paint to the welded portion as per drawing /standard (all materials to be supplied by contractor)

5200

682

3549676

... More
ele211 - b) Grounding of equipments with 75*12 mm GI flat and connecting equipments to the earthmat/ground pit including all connected works.

1100

984

1083170

... More
ele212 - c) Providing 25mm dia 1.05mtr long earthmat spike of MS rod including bending top 50mm etc and connecting to earthmat as per specidication.

120

486

58437.6

... More
ele213 - d) Supplying and Providing CI pipe of 100mm ID 13mm thick 2.75mtr long with 2 part GI flat 50*6 mm clamp welded allround the pipe etc including the cost of excavation( all materials supplied by contractor)

58

17504

1015245.34

... More
ele214 - e) Supplying and fixing 450mm dia x 450mm dia height 1.5 in to 2 in hume pipe collars for earth pits.

58

1611

93462.94

... More
ele215 - Construction of embankment by excavating the available approved gravel/murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage and all other appurtenaces required to complete the work. (for filling using borrowed earth) (Vol-01 I.No. 1.8 P.No.7)

800

509

407640

... More
ele216 - Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth(Vol-01 I.No. 1.12 P.No.8)

400

102

40852

... More
ele217 - Earth work excavation for foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (Vol-1 I.No.1.14.1, P.No.8)

4088.01

109

448250.2965

... More
ele218 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (Vol-01 I.No. 2.1.2 P.No.15)

385.28

6683

2574934.1184

... More
ele219 - Providing and laying in position Reinforced cement concrete for all foundation works. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Note: for foundations of CRB and all electrical equipments, cable ducts, culverts, coping, sump, gate, switch gear shelter etc., + 8% extra for form work. V-1, I.No. 2.2.1. pg-15-

531.73

7356

3911459.053

... More
ele220 - Providing and laying in position Reinforced cement concrete for drain works. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ( for RCC drain., + 35% extra for form work) V-1, I.No. 2.4.2 pg-16

60.55

9195

556764.516

... More
ele221 - Providing and laying in position Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc.. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. -( for plinth beam + 50% extra for form work) V-1, I.No. 2.3.1, pg-16

9.02

10449

94249.98

... More
ele222 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.-( for roof beams and lintels, + 60% extra for form work)- at ground floor V-1, I.No. 2.5.1, pg-16

27.56

11769

324380.0976

... More
ele223 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. -( for roof beams and lintels, + 60% extra for form work+1% extra for lift charge)- at first floor V-1, I.No. 2.5.1, pg-16

11.43

11887

135875.9538

... More
ele224 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. -( for roof slabs, Stair case + 50% extra for form work)-at ground floor V-1, I.No. 2.5.1,pg-16

56.43

11034

622667.8062

... More
ele225 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. -( for roof slabs, + 50% extra for form work+1% extra for lift charge)-at first floor V-1, I.No. 2.5.1,pg-16

38.38

11144

427732.8184

... More
ele226 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. -( for colums in super structure, + 70% extra for form work)-at ground floor V-1, I.No. 2.5.1, pg-16

20.53

12505

256739.5574

... More
ele227 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. -( for colums in super structure, + 70% extra for form work+1% extra for lift charge)-at first floor V-1, I.No. 2.5.1, pg-16

9.35

12630

118096.484

... More
ele228 - Providing and laying in position Reinforced cement concrete for all foundation works. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. V-1, I.No. 2.2.1.pg-15-( for colums below GL, + 70% extra for form work)

6.46

11579

74800.5984

... More
ele229 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. V-1, I.No. 2.5.1, pg16-( for chejja and canopy, + 45% extra for form work) at ground floor

4.54

10666

48426.0462

... More
ele230 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. V-1, I.No. 2.5.1, pg16-( for chejja and canopy, + 45% extra for form work+1% extra for lift charge) at first floor

7.94

10773

85539.1286

... More
ele231 - Providing and laying in position Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc.. the ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. V-1, I.No. 2.3.1, pg-16-( for RCC retaining wall + 10% extra for form work)

298.84

7662

2289891.384

... More
ele232 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates. ( for embedding angles coping etc + 3% extra for form work) KPWD SR 2021-22, Volume-I,page 15, Item No:2.1.4,

84.46

6883

581403.2142

... More
ele233 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. the granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work and all other17 Item No. Description of Item Unit Rate Rs. appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. ( for sill, coping, screed concrete etc + 3% extra for form work) (Vol-1,I.No 2.4.1 P.No 17)

30.71

7090

217759.3893

... More
ele234 - Steel fabrication: Supplying, fitting and placing tMt fE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification V-1, I.No. 2.11(a), Page No. 18- for buildings

26301.49

96

2529414.2933

... More
ele235 - Steel fabrication: Supplying, fitting and placing tMt fE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. V-1, I.No. 2.11 (h), Page No. 18-for all other type of structures

47300.72

84

4017723.1568

... More
ele236 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a 2 coat of approved paint over the priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Volume-2,page 77 Item No:11.2,

22786.3

116

2645489.43

... More
ele237 - filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift upto 1.5 m.V-1, I.No. 1.9, Page No. 7

1357.11

285

388065.6045

... More
ele238 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Vol-03 I.No.3.1 P.No.17)

1495.9

91

136695.342

... More
ele239 - Providing and constructing load bearing wall with solid concrete blocks of size 400x200x200mm with CM 1:4 a per IS2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. KPWD SR 2021-22, Volume-II, page 17 Item No:6.32,

318.72

1408

448837.44

... More
ele240 - Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. V-2, Page No. 41, I.No. 8.3.2,

2435.47

357

871849.5506

... More
ele241 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. V-2, I.No. 8.1.2, Page No. 41

731.07

259

189405.6156

... More
ele242 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :two coats on new work over one coat of primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. V-2, Page No. 48, I.No. 8.39 +I No-8.55.2, pg-51

480.94

193

93061.89

... More
ele243 - finishing walls with Acrylic Smooth exterior paint of required shade New work (two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.V-2, Page No. 46, I.No. 8.30

3047.35

187

570006.8175

... More
ele244 - finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's pecifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. V-2, Page No. 48, I.No. 8.36.2

139.19

184

25736.231

... More
ele245 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. V-2, I.No. 8.51, Page No. 50

480.94

107

51701.05

... More
ele246 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. V-2, I.No. 8.33.3, Page No. 47

8

149

1195.44

... More
ele247 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade) ( Vol-2, P No 95 I No 11.59)

173.56

904

156912.1248

... More
ele248 - fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire (Vol-2,P No 95 I No 11.57)

2580

19

49923

... More
ele249 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (Vol-2,P No 14 I No 6.8)

167.37

8566

1433805.2316

... More
ele250 - Providing SandS RCC SPUN / VIBRAtED CASt PIPES (REINfORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for SandS RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey 300 mm dia vol-5, pg-188, I-16.3.2

50

1431

71595

... More
ele251 - Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Vol-II, pg-9 Item No:5.4,

5.41

6868

37156.8538

... More
ele252 - Providing flush/ruled pointing on stone work with cement mortar 1:3 after raking joints to depth nicely lining, including cost of materials, labours, curing as per specifications and direction of engineer in-charge of work. Vol-II, pg 44 Item No: 8.19.1,

7.8

274

2138.214

... More
ele253 - Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. Vol-3, Pg-163, I-4

150

75

11287.5

... More
ele254 - Providing and filling joint sealing compound as per approved drawing and technical specification with coarse sand and 6 percent bitumen by weight, Vol-3, Pg-124, I-13.15 (iv)

150

51

7740

... More
ele255 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :for shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. V-2, I.No. 11.35.2.3. Page No. 88

470.36

625

294280.734

... More
ele256 - Providing and fixing double action hydraulic floor spring of approved brand manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge: With brass cover plate minimum 1.25 mm thickness including cost of materials, labour, usage charges of machinery complete as per specifications. V-2, I.No. 11.38.2. Page No. 90

5

3014

15071.5

... More
ele257 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. Vol-2/14/6.13

121.24

1049

127205.008

... More
ele258 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. V-2, I.No. 12.62, Pagge No. 105

10

254

2547.8

... More
ele259 - Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete. 125x85x5.5mm (Heavy type) : V-2, I.No. 12.75.1, Pagge No. 107

27

295

7982.01

... More
ele260 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. V-2, I.No. 12.63, P-105

10

139

1397.5

... More
ele261 - Providing and fixing magnetic catcher of approved quality in cupboard ward robe shutters, including fixing with necessary screws etc. complete. V-2, I.No. 12.65, Page No. 105

5

63

317.15

... More
ele262 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.V-2, I.No. 12.60 Page No. 105

10

1130

11309

... More
ele263 - supplying and fixing hold fasts Hold fasts. V-2, pg. A25, I.no 444

20

53

1075

... More
ele264 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of ngineer-in charge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. V-2, pg. 89, I.no 11.36.1

6

964

5785.68

... More
ele265 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. V-2, pg. 89, I.no 11.37.2

30

1258

37764.9

... More
ele266 - filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to AStM C920, DIN 18540- f and ISO 11600 Upto 20 mm depth and 20 mm width including cost of materials, labour, usage charges of machinery complete as per specifications. V-2, pg. 94, I.no 11.53.3

200

318

63640

... More
ele267 - Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. V-2, I.No.12.12, Page No. 99

0.5

133517

66758.575

... More
ele268 - Providing and fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top and bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet and 30 x 50mm wide to form stiles and 5mm thick and 75mm wide PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick 20mm wide PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. frame, Sealed to the stiles and rails with 5x30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., Complete as per manufacturers specification and direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. Vol-2, 105/12.53

10

1707

17071

... More
ele269 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. V-2, I.No. 9.24, Page No. 63

171.5

3065

525801.85

... More
ele270 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. V-2, I.No. 9.39, Page No. 65

40.49

1557

63070.4632

... More
ele271 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile V-2, I.No. 9.7.2, Page No. 60

34.94

1354

47326.23

... More
ele272 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile. V-2, I.No. 9.7.1, Page No. 59

14.02

1339

18779.089

... More
ele273 - Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of t-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. V-2, I.No. 11.3, Page No. 77

8

8896

71173.6

... More
ele274 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. fixed to steel windows by welding. V-2, Page No. 86, I.No. 11.34A

70

180

12642

... More
ele275 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge V-2, Page No. 85, I.No. 11.28

1110

607

674191.8

... More
ele276 - Providing and fixing Heat Resistant terrace tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) Greather than 78, solar reflection Greather than 0.70 and initial emittance Greather than 0.75 on waterproof and slo[ed surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement :4 coarse sand) and grounting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm heightr along the parapet walls in the same manner as per direction of incharge V-2, Page No. 29, I.No. 7.46

298.17

1510

450350.0046

... More
ele277 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 90mm dia., 6 kg/Sq cm and class 3: V-5, Page No. 113, I.No. 10.1.6

50

316

15802.5

... More
ele278 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:. PVC pipes 110mm dia., 6 kg/Sq cm and class 3, V-5, Page No. 113, I.No. 10.1.7

286

441

126363.38

... More
ele279 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/Sq cm and class 3, V-5, Page No. 113, I.No. 10.1.9

150

664

99652.5

... More
ele280 - Providing and fixing CPVC pipes having thermal stablity for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per specifications - 32mm nominal dia pipes. Vol-2,Page No. 122, I.No. 13.31.4

100

430

43000

... More
ele281 - Providing and fixing CPVC pipes having thermal stablity for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per specifications - 20mm nominal dia pipes. Vol-2,Page No. 122, I.No. 13.31.2

50

260

13007.5

... More
ele282 - White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. V-2, I.No. 14.7.2, Page No. 132

4

2753

11012.32

... More
ele283 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. One urinal basin with 5 litre white P.V.C. automatic flushing cistern. V-2, Page No. 131, I.No. 14.4.1

2

4788

9576.1

... More
ele284 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangular shape 453x357 mm, V-2, Page No. 136, I.No. 14.32.2

4

1094

4377.4

... More
ele285 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia, V-2, Page No. 136, I.No. 14.28.1.1

4

81

326.8

... More
ele286 - Providing and fixing 100 mm sand cast Iron grating for gully trap.V-2, Page No. 136,I.No. 14.29

10

50

505.3

... More
ele287 - Providing and fixing PtMt towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. V-2, Page No. 137, I.No. 14.40.2

4

533

2132.8

... More
ele288 - Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. V-2, Page No. 134, I.No. 14.16A

4

292

1169.6

... More
ele289 - Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat and lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend., V-2, Page No. 137, I.No. 14.35.1

2

9279

18558.8

... More
ele290 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. V-2, Page No. 131, I.No. 14.1.1

2

5250

10500.6

... More
ele291 - Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.V-2, I.No. 14.8, Page No. 133

4

1529

6118.92

... More
ele292 - Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. V-2, Page No. 137, I.No. 14.37.1

5

328

1644.75

... More
ele293 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. V-2, Page No. 117, I.No. 13.4.2

1

642

642.85

... More
ele294 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893. V-2, Page No. 119, I.No. 13.12

4

682

2730.52

... More
ele295 - Supplying and filling Brick Bats of size 25 to100 mm to soak pit as per direction of Engineer Incharge of work . MR

30

638

19156.5

... More
ele296 - Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)V-2 Pno.9 Ino.5.2

12

7114

85372.2

... More
ele297 - Providing and fixing rainy make rain water filter of fL500 specification as per direction of engineer in charge of work. (MR)

1

11287

11287.5

... More
ele298 - Providing and fixing 1.5HP mono submersible pump set for rain water sump with electrification including necessary cables and control panels (MR)

2

10750

21500

... More
ele299 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) A] depth Upto 0 to 50.00 Mtr (V-V P-139 I-12.1.1)

50

397

19887.5

... More
ele300 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) B]depth 50.00 Mtr to 100.00 Mtr (V-V P-139 I-12.1.2)

50

498

24940

... More
ele301 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) C] depth 100.00 Mtr to 150.00 Mtr (V-V P-139 I-12.1.3)

50

529

26499

... More
ele302 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) D] depth 150.00 Mtr to 200.00 Mtr (V-V P-139 I-12.1.4)

50

614

30745

... More
ele303 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) E] depth 200.00 Mtr to 250.00 Mtr (V-V P-139 I-12.1.5)

50

721

36066.5

... More
ele304 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) f] depth 250.00 Mtr to 300.00 Mtr (V-V P-139 I-12.1.6)

50

795

39775

... More
ele305 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) G] depth 300.00 Mtr to 350.00 Mtr (V-V P-139 I-12.1.7)

50

933

46655

... More
ele306 - Sinking of borewell of 165mm mm clear using Super fast hydrualic rig of capacity 3000PSIG and above 1100CMf and above in all strata including over burden upto 20 m fixing of casing pipe, collers and cap with necessary cutting and threading and welding including transportation of rig and supporting vehicles screw charges and cost of consumables etc., complete including yeld testing at final depth with minimum continous working of compressor for 1 hour(Excluding cost of casing pipes,collars and cap etc) H] depth 350.00 Mtr to 400.00 Mtr (V-V P-139 I-12.1.8)

50

1007

50364

... More
ele307 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel fe 410 of wall thickness conforming to IS 4270-2001 andlatest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. the tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.pricesinclude Collar-Medium duty Vol- 5, I-12.32,Pg- 143

25

2077

51949.5

... More
ele308 - Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. the thickness of plate used for covering one end shall be 3mm (minimum). the dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge Vol-5, I -12.34,P-143

1

176

176.3

... More
ele309 - Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOtE: 1) Additional rate on item 1and2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete (Vol-5 P-140 I- 12.4)

1

5684

5684.6

... More
ele310 - PUMPSEt : Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments etc. complete 5.00 HP 50 StG (V-5 P-151 I- 13.10.4)

1

31873

31873.75

... More
ele311 - Supply and delivery at site Brand new best make PVC insulated submersible cable of flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 3CX4.0Sq.mm(V-5 P-154 I- 13.22.3)

900

145

130617

... More
ele312 - PRESSURE GAUGE : Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. for size 100mm (V-5 P-154 I-13.23.3)

1

703

703.05

... More
ele313 - GAtE VALVE : Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments. 50mm(V-5 P-154 I- 13.24.1)

1

1343

1343.75

... More
ele314 - NON - REtURN VALVE : Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments.Size 50mm (V-5 P-154 I- 13.25.1)

1

1343

1343.75

... More
ele315 - Control panel board for borewell motor pumpset: Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SfU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUtGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current and dry run protection suitable for the pump described above 1 no Indoor type NOtE: 1) DOLDirect Online Starter 2)S-D- Star Delta Starter.3 to 6HP Pumps(V-5 P-155 I- 13.23.2)

1

10266

10266.25

... More
ele316 - POWER CAPACItOR : Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPtCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.(V-5 P-55 I- 13.25)

2

591

1182.5

... More
ele317 - MCB : Supply and delivery at site delivery of best indigenous brand new MCB(Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. (V-5 P-155 I- 13.26)

1

1236

1236.25

... More
ele318 - HDPE Pipes: Supplying and installation of 50mm dia HDPE pipes of specified grade and confirming to IS standards and direction of engineer in charge of work including cost of labour, materials etc., complete as per specification(MR)

450

215

96750

... More
ele319 - Erection elctrification and Commissioning works of pumpsets : Labour Charges Including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps borewell cap, cable clips, water right glands, cable protectors bolts, nuts, valves and gauges etc., involved in the job. the contractor has to arrange at his own cost all erection materials. (V-5 P-156 I- 13.32)

1

6987

6987.5

... More
ele320 - Main connections: Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPtCL pole to meter board unit.(V-5 P-156 I- 13.36)

100

145

14513

... More
ele321 - Earthing : suplying, fixing and wiring earth electordes for grouding conduits, I.C cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit.. the pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and check nuts., the pipe shall have 16 through holes of 122 mm dia. (V-5 P-157 I- 13.39)

1

4031

4031.25

... More
ele322 - ELECtRICAL ACCESSORIES: Supplying of tPSt with reqirable porcelain channels in SM enclosure, made out of 14 SWG powder coated paint of approved colour. 32 AMPS. (ELE SR-23-24 INO;5.5.1 PNO;14)

6

1828

10971.48

... More
ele323 - Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 AMPS (ELSR-23-24 INO;5.7.2 PNO;14)

6

259

1554.48

... More
ele324 - Providing and fixing CPVC pipes having thermal stablity for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per specifications a] 50mm dia ( V.No 2 I.No. 13.31.6)

100

839

83958

... More
ele325 - Providing and fixing CPVC pipes having thermal stablity for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per specifications b) 40mm dia ( V.No 2 I.No. 13.31.5)

150

576

86430

... More
ele326 - Providing and fixing CPVC pipes having thermal stablity for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per specifications c] 25mm dia (V.No 2 I.No. 13.31.3)

75

341

25638.75

... More
ele327 - Providing and fixing pre moulded multi diameter cable ceiling system of nitrate rubber along with frame shall be provided at the entry of 220kV and 66kV side power/control cables/instrumentation cables into the CRB. the size of the pre moulded cable sealing system shall be suitable for diameter of respective cables.the execution of the fixing of moulds at cable entry shall be done such that it is water proof, fire proof, rodent proof etc. (MR)

2

21500

43000

... More
ele328 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing I cover and frame etc. excluding the cost of CI frame and cover- vol-5, pg-221, item 16.9)

10

5863

58630.5

... More
ele329 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover:- vol-5, pg-221, item16.10)

12

4553

54644.4

... More
ele330 - Providing and fixing SfRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete.Medium Duty

22

2057

45266.1

... More
ele331 - Providing and fixing board displaying information, such as 'Name of work, tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge and MoRtH specification 804 KPWD SR 2021-22 Vol-III, pg 78 Item No: 8.54,

1

9675

9675

... More
ele332 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(Vol-2, 13.34, pg-123)

2000

9

19360

... More
ele333 - Providing and laying in position Reinforced cement concrete for Road works. the granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form works and all the other appurtenances required to complete the work as per technical specifications. (the cost of steel reinforcement to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. V-1, I.No. 2.5.5 pg 18-( for + 5% extra for form work)

75

8490

636784.5

... More
ele334 - Providing, laying, spreading and compacting graded stone aggregates to wet mix macadam specifications including premixing the materila with water at OMC in mechanical mix plant carriage of mixed material by tipper to site,laying in uniform layers with paver/grader in sub-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density. V-3, I.No. 4.17 pg 26-

108

2750

297100.44

... More
ele335 - Construction of subgrade and earther shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requiremnt of table No.300-2 V-3, I.No. 3.6 pg 17

48

529

25439.04

... More
ele336 - Bituminous layer for oil sump: Providing and laying of 1.5 mm thick SBS modified self adhesive single stick waterproofing membrane, with minimum elongation of 300% and puncture resistance of Greather than 200 N (as per AStM E154), with an overlap of 100mm on the side and 100mm in vertical lapping over a coat bituminuos primer @ 0.25 l/m2, complete including surface preparation as per the methodology and site condition and placing the dimple board over the SBS membrane. the cost is nclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification. V-2, I.No. 15.3 pg 149

21.6

818

17670.528

... More
ele337 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications

1235

172

212420

... More
ele338 - Jelly spreading(20-25mm) : Supplying and providing jelly in the station yard of uniform thickness of 100mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.

2370

190

451722

... More
ele339 - Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick. Page No. 2, I.No. 1.2.1)

250

70

17737.5

... More
ele340 - Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick. (Page No. 2, I.No. 1.2.2)

180

83

15093

... More
ele341 - Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thick. (Page No. 2, I.No. 1.3.1)

150

73

10965

... More
ele342 - Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick. (Page No. 2, I.No. 1.3.2)

100

84

8493

... More
ele343 - Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100x75x65mm (Page No. 2, I.No. 1.4.2)

6

126

761.1

... More
ele344 - Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 135x75x65mm (Page No. 2, I.No. 1.4.3)

5

149

747.15

... More
ele345 - Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using Nf screws and on either end of the pipe terminated completely. 25mm(Page No. 3, I.No. 1.9.2)

50

23

1182.5

... More
ele346 - Supplying And fixing Metal fan Box with Round Hook. (Page No. 4, I.No. 1.12)

10

125

1257.8

... More
ele347 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) fRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box (Page No. 5, I.No. 2.2.1)

20

289

5783.6

... More
ele348 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) fRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box. (Page No. 5, I.No. 2.2.2)

30

407

12222.9

... More
ele349 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) fRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box. (Page No. 5, I.No. 2.2.3)

25

596

14915.75

... More
ele350 - Wiring for lighting/power circuit using one of fRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 (Page 5, I.No. 2.3.2)

250

27

6987.5

... More
ele351 - Wiring for lighting/power circuit using one of fRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 (Page No. 5, I.No. 2.3.3)

300

45

13545

... More
ele352 - Wiring for lighting/power circuit using one of fRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm 2 (Page No. 5, I.No. 2.3.4)

350

67

23705.5

... More
ele353 - Wiring for lighting/power circuit using one of fRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 mm 2 (Page 5, I.No. 2.3.5)

250

98

24725

... More
ele354 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in Brick/ Stone/ C.C wall. 1-2 way (Page No. 8, I.No. 3.4.1)

15

148

2225.25

... More
ele355 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in Brick/Stone / C.C wall. 6Way. (Page No. 8, I.No. 3.4.4)

3

236

709.5

... More
ele356 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8Way. (Page No. 8, I.No. 3.4.5)

4

280

1122.32

... More
ele357 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way (Page No. 8, I.No. 3.4.6)

6

342

2057.58

... More
ele358 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16-18Way ( (Page No. 8, I.No. 3.4.7)

6

390

2341.38

... More
ele359 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 3 Module (Page No. 8, I.No. 3.5.1)

15

147

2209.2

... More
ele360 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module (Page No. 8, I.No. 3.5.4)

3

251

754.65

... More
ele361 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. PVC 8 Module (Page No. 8, I.No. 3.5.5)

4

305

1221.2

... More
ele362 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10 -12 Module. (Page No. 8, I.No. 3.5.6)

6

369

2218.8

... More
ele363 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16-18 Module. (Page No. 8, I.No. 3.5.7)

6

426

2560.68

... More
ele364 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch(Page No.9 Item No.3.6.1)

80

109

8772

... More
ele365 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A two Way Switch (Page No.9 Item No.3.6.2)

2

178

356.9

... More
ele366 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A three Way socket (Page No.9 Item No.3.6.3)

30

183

5514.9

... More
ele367 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped fan Regulator two Module (Page No.9 Item No.3.6.4)

10

383

3837.8

... More
ele368 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch.(Page No.9 Item No.3.6.7)

4

193

774

... More
ele369 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Bell Push.(Page No.9 Item No.3.6.8)

2

190

380.56

... More
ele370 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch.(Page No.9 Item No.3.6.9)

10

350

3504.5

... More
ele371 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 12933 6/16A Universal Socket.(Page No.9 Item No.3.6.10)

10

253

2537

... More
ele372 - Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. f. screws.(Page No.9 Item No.3.9)

600

-

228

... More
ele373 - Extra for supplying 4 mm thick white plastic plate andcovering for junction boxes of size ...... mm conduit using necessary machine screws. 80/90 mm.(Page No.9 Item No.3.10.2)

15

16

241.95

... More
ele374 - Extra for supplying 4 mm thick white plastic plate andcovering for junction boxes of size ...... mm conduit using necessary machine screws.110 mm.(Page No.9 Item No.3.10.3)

20

22

451.6

... More
ele375 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Lamp Holder.(Page No.10 Item No.3.14.6)

6

76

457.98

... More
ele376 - Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.100 A.(Page No.14 Item No.5.7.4)

6

742

4456.98

... More
ele377 - Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution).100 A(Page No.15 Item No.5.12.2)

1

9174

9174.05

... More
ele378 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in thermal Magnetic Release. Micro processor release shall have Earth fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. for Microprocessor MCCBS facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.fOUR Pole.100 A 25 kA(Page No.17 Item No.5.15.9)

2

9123

18247.06

... More
ele379 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/Off, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP(Page No.17 Item No.5.18.1)

10

446

4461.3

... More
ele380 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/Off, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A SP(Page No.17 Item No.5.18.3)

6

871

5230.98

... More
ele381 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/Off, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A tPN(Page No.17 Item No.5.18.7)

6

1845

11074.68

... More
ele382 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/Off, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A tPN(Page No.18 Item No.5.18.9)

2

3319

6639.2

... More
ele383 - Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.II - Double Door.12 Way SP and N (Page No.18 Item No.5.19.9)

6

2503

15022.08

... More
ele384 - Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.16-25 A 2 pole (Ele SR 2021-22 Page No.13 Item No.5.20.1)

6

4597

27586.68

... More
ele385 - Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.63 A 4 pole (Ele SR 2021-22 Page No.13 Item No.5.20.4)

1

5960

5960.88

... More
ele386 - Supplying, fixing and wiring earth leakage relay with corebalanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. (Page No.18 Item No.5.21)

1

9949

9949.13

... More
ele387 - Supplying, fixing and wiring 0 to 1500A Ct operated AC analog type Ammeter without Ct (Page No.18 Item No.5.26)

2

516

1032

... More
ele388 - Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter (Page No.19 Item No.5.29)

2

1531

3063.76

... More
ele389 - Supplying, fixing and wiring Electronic trivector Meter (EtV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (Page No.19 Item No.5.35)

1

6132

6132.88

... More
ele390 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (Page No.19 Item No.5.38)

3

553

1660.89

... More
ele391 - fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG (Page No.15 Item No.5.42.2)

40000

-

18400

... More
ele392 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.(Page No.30 Item No.6.1)

4

1603

6415.6

... More
ele393 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.15" Sweep (450 mm)(Page No. 30 Item No.6.2.2)

2

4779

9558.9

... More
ele394 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model(Page No. 30 Item No.6.3.1)

5

3207

16039

... More
ele395 - Supplying wall mounting fan suitable to operate at singlephase 230v AC. supply.400 mm Sweep (Page No.30 Item No.6.5.2)

2

3452

6905.8

... More
ele396 - Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI Greather than 80. Power Input: 220-240V@ 50/60Hz and Power factor Greather than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4 - 20/22 W(Page No. 43 Item No. 11.3.2)

20

741

14835

... More
ele397 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling ciA, Power LEDs with CCt 6500 degree K, CRIGreather than 70%. efficacy Greather than 100 lumen per W, 120degree beam spread, lifeGreather than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 and LM 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by Hf electronic driver integrated in a separate control gear assembly., with Pf Greather than 0.95, power loss should less than 5% of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, tHD less than 20%, Life as per LM 79. the operating input voltage should be between 130 to 275 V. BIS Approved and tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2 x 2 / 40-42 W(Page No. 45 Item No. 11.6.4)

10

5225

52255.8

... More
ele398 - fixing all types and all capacities of fluorescent /false ceiling / spot light / CfL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / Girders.(Page No.56 Item No.13.7.1)

30

131

3934.5

... More
ele399 - fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring..(Page No.57 Item No.13.10)

7

183

1286.81

... More
ele400 - Extra length of GI pipe of class B 19mm dia for down rod.(Page No.57 Item No.13.12)

15

211

3176.7

... More
ele401 - fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame..(Page No.57 Item No.13.13)

7

760

5320.21

... More
ele402 - Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete.5kVA Capacity(Page No.38 Item No.9.1.3)

5

10390

51954.75

... More
ele403 - Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. the pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. the connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Volume -5 Page No.157 Item No.13.39)

5

4031

20156.25

... More
ele404 - 66KV, 1000sqmm XLPE UG Cable 66KV (E) grade, 1 core, Circular, stranded, plain annealed Segmental compact type miliken copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semi-conducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification. (Route Length 7.50Km + Raising and loop 0.010+0.010)*3*1.1)

32.228

16441050

529862159.4

... More
ele405 - Outdoor type cable end termination suitable for 66KV (E) 1 -core, 1000sqmm, Segmental compact type miliken copper conductor, XLPE, lead sheathed cable including PVC earthing cable.

18

295270

5314864.5

... More
ele406 - Supplying of Joints suitable for 66KV(E) 1 -core 1000 sqmm, Segmental compact type miliken copper conductor, XLPE, Lead sheathed cable, Normal Straight through Joints.

63

182105

11472615

... More
ele407 - 66kV Link boxes, single phase outdoor structure mounting type with SVL/CCPU and PVC earthing cable.

18

37721

678991.5

... More
ele408 - three phase cross bonding Link box with SVL including 240 Sq mm sheath bonding cable and 240/240 Sq mm co-axial cable as per technical specification suitable for 110 kV and 66 kV, 1000/630/400/240 Sq mm UG Cable. the Link box shall be burried type, water proof (capable of immerssion in water), weather proof, rust and dust proof (IP: 68)

9

113165

1018487.25

... More
ele409 - three phase Link box without SVL including 240 Sq mm sheath bonding cable and 240/ 240 Sq mm co-axial cable as per technical specification suitable for 110 kV and 66 kV, 1000/630/400/240 Sq mm UG Cable. the Link box shall be burried type, water proof(capable of immerssion in water), weather proof, rust and dust proof (IP: 68)

13

70240

913126.5

... More
ele410 - terminal connectors to connect cable end termination to the Single DRAKE ACSR conductor/ Aluminium rigid pipe heavy type with bolts and nuts and washers complete.

18

1197

21555.9

... More
ele411 - OfC Cable and Accessories: a)Unarmoured Under Ground fiber Optic Cable (48f DWSM) as per technical specifications.

10.1

117175

1183467.5

... More
ele412 - b) Poly Vinyl Lubricated Bond (PLB) HDPE OD 40mm with accessories.

10.1

105350

1064035

... More
ele413 - c) OfC end terminal (Line Interface unit LIU suitable for 48f)

6

22112

132676.5

... More
ele414 - d) Straight joint closure kit for OfC(48f)

24

9105

218526

... More
ele415 - e) Collars for PLB pipe.

14

168

2362.92

... More
ele416 - f) Media Converter.

14

5203

72842

... More
ele417 - 110KV D/C Cable termination tower (Ctt) Cable terminating tower with stubs for terminating 110kV, 400sqmm Single core UG Cable : fabrication and supply of Galvanised steel tower parts including necessary Clamps for fixing the Cable etc., including necessary provision for fixing the LA's and Link Boxes etc., as per design and technical specification for termination of Single Core 110KV UG cable and the 110kV Over head transmission line (Ctt Modified cross arm 110KV NBt KPtCL Design ) Including Bolt, Nuts and washers.

2

145684

291368

... More
ele418 - 66kV UG Cable Surveying: Detailed survey along the route alignment by using Modern Survey equipment like DGPS /total stations / Digital theodolites / GPS including profiling by using computer aided techniques as detailed in the scope of work, includes the following: Drawing the route profile including features like Roads, Railway lines, drains, park, gardens, Pandt Lines, Railways crossing etc., * Preparation of cable route profile and final cable route alignment, marking lines and grades. Leveling of the profile with reference to Survey of India bench marks (MSL). * Line Schedule along the Right of Way. * Soil resistivity along the selected route with measurement at a distance not exceeding 2 km. * Route marking along the route with GPS Co-ordinates at every 50 m duly marking road/power line/telecommunication/railway line crossings. * Making 150 mm dia bore holes for a depth not less than 3 m or refusal strata at every 50 m for soil classification along with GPS Co-ordinates for each bore holes and back filling of bore holes on completion of work. * Burgie details and providing GPS, Co-ordinates at every 50 m, turning Pointincluding permanent marks, like poles, telephones lines, buildings etc., * Submission of detailed consolidated final report for surveying work done appending all the reports including all relevant information collected during survey, calibration certificates of the instruments used for the work, photos/videos taken at site and submitting soft copies of all documents and hard copy of reports in 6 sets. * the detailed report shall contain detailed Survey Report/Soil Resistivity Report/ Line Schedule/Land schedule/Geo referenced and superimposed on the line corridor. (UNISR Vol-6 Page No.156, Sl No. 6)

10.74

16824

180698.6742

... More
ele419 - Laying including testing and Commissioning : 66kV EHt single core XLPE copper cable in trefoil, tapping, fixing pipes for drain and gate crossing as per drawings and specification in trench pipes, ducts by pulling, drawing etc., handling of cable drums, paving out cables using standard cable installation equipment. NOtE: the rate per km shall include laying one circuit per km each circuit consisting of 3 nos. of single core cables including transport of cable drums material equipment to site and retaining unused items to stores. ( UNISR 23-24 Vol 6, Pg 130, 30.a

10.978

436450

4791348.1

... More
ele420 - Handling and making normal straight joints/Insulated shield break type Joint for EHV power cables with all consumables at site etc., complete (UNISR Vol-6, Page No. 130, SL No. 30.c)

63

63462

3998145.69

... More
ele421 - Handling and making of cable end termination for 66kV EHV single core XLPE copper cable. (UNISR 23-24 Vol 6, Pg 130, 30,d)

18

63462

1142327.34

... More
ele422 - Erection of Single phase earth link boxes (3 Nos.) on to the cable mounting structure connecting earth leads with all lugs, fixtures, clamps bolts and nuts complete (UNISR Vol-6, Page No. 130, SL No. 30.e)

18

15865

285573.78

... More
ele423 - Erection of three phase earth link box at Joint bay with connecting earth leads, all lugs, fixtures, clamps bolts and nuts complete (for Straight/Cross Bonds)

22

47595

1047103.86

... More
ele424 - Supply and erection of earthing materials including CI pipe with suitable clamps, collor, earth lead cable, salt, charcol etc., and all necessar earth works etc with complete set. (UNISR Vol-6, Page No. 115, item 6.c) (LinkBox-6Nos at Either end of S/s, 4 No's inside JB)

40

17504

700169.2

... More
ele425 - Charges for conducting precommissioning tests as per IEC 60840, IS 7098 Part - III and successful commissioning of UG transmission line.

2

537500

1075000

... More
ele426 - Laying of 48 fiber single mode, unarmoured Under Ground fO cable as per drawings and specifications.

10.1

40850

412585

... More
ele427 - Handling and making normal straight joint closures for 48 fibre Dual Window Mono Mode(DWMN) Optical fibre cable with all consumables at site complete.

24

7159

171828

... More
ele428 - Handling and making terminal joints for 48fiber unarmoured Under Ground fO cable with all consumables at site complete.(Normal Straight Joint Rates considered)

6

15596

93576.6

... More
ele429 - Erection of towers including tack welding, fixing of tower accessories and earthing (the weight includes the wt. of std., tower and stubs, including bolts nuts and washers)

19.26

6152

118491.9498

... More
ele430 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails and bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kind of soil Depth upto 1.50 m.

4816.024

281

1356433.1596

... More
ele431 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails and bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m .

1251.93

488

611004.4365

... More
ele432 - Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails and bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock (blasting prohibited) Depth upto 1.50 m.

625.96

1090

682327.698

... More
ele433 - Dismantling of flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Mean Bituminous courses.

768.6

346

266050.89

... More
ele434 - Dismantling of flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Mean Granular course.

2075.22

56

118246.0356

... More
ele435 - Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately

20

605

12104.6

... More
ele436 - Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. the rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure.

6400.275

2112

13519812.9045

... More
ele437 - Supplying and Providing pre cast RCC Protection Covers using M20 grade Concrete, steel of approved size/shape (as per the approved drawings) to be laid in UG cable works. the rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.

3050

1395

4255817.5

... More
ele438 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.

168.2

172

28930.4

... More
ele439 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work.

6131.475

91

560294.1855

... More
ele440 - Supplying and Providing Pre cast Cable Route/ Joint marker using M15 grade Concrete, MS rods of approved size/shape (as per the approved drawings) to be laid in UG cable works. the rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.

166

367

61029.9

... More
ele441 - HDD method for laying of 66kV SC UG Cables: Installation of 3 rows of HDPE pipes PE 80 PN6 of 160 mm dia using Horizontal directional drilling technique (HDD method) including preparing and setting up the plant and equipment, preparing and installation of new pipe work materials and commissioning system or making the system ready for commissioning by HDD operation including all excavation, shoring/strutting etc., drilling, stringing, ramming and pulling back the new work on the design bore path alignment, proper disposal of drilling fluid and restoration of site after completion etc., for HDD technique suiting Indian conditions in all types of soil. for Single circuit

2315.64

9012

20870400.192

... More
ele442 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. the granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (SR 23-24 V1/Pg15/2.1.6)

22.79

6088

138763.752

... More
ele443 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. the granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates.

459.5

6711

3083810.185

... More
ele444 - Providing and laying of warning tape / Caution tape / detector tape for HDPE pipes of 200 mm wide, 300 micron thick, blue in colour confoming to relevant ISS with latest amendments with appurtenances., complete.

6700

8

57620

... More
ele445 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. the rate is exclusive of required specials and fittings wherever necessary like saddle tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOtE: Upto 110mm dia Coil shall be used. HDPE Grade PE80-PN6.0,160mm dia (SR 23-24 V5/90/9.17)

7200

757

5456736

... More
ele446 - Construction of Granular Sub-Base of grading V material as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401

1178.52

2673

3150808.5756

... More
ele447 - Steel fabrication: Supplying, fitting and placing tMt fE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification

7846

84

666439.24

... More
ele448 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying inuniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density

1281

2750

3523941.33

... More
ele449 - Prime Coat over WMM/WBM: Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg per m2 using mechanical means

5124

44

225865.92

... More
ele450 - tack coat on Granular surface treated with primer:Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.25 kg/m2on the prepared bituminous surface cleaned with mechanical broom

5124

12

66099.6

... More
ele451 - Dense Graded Bituminous Macadam Grading -II for traffic lesser than 20 MSA Providing and laying Bituminous Macadam with 120 tPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction

384.3

10562

4059341.685

... More
ele452 - Providing and laying Bituminous Concrete with 120 tPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.2 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired ompaction as per MORtH specification clause No. 507 complete in all respect

204.96

11860

2430923.9808

... More
ele453 - Earth work excavation in Normal Dry soil / Dry BC soil: Supply of all labour, materials, Machineries etc., and excavation with all leads and lifts for tower foundations including back filling with available approved earth/ approved new earth, watering and compaction in layers of 150mm thick, disposal of surplus earth to the places directed, spreading, leveling etc., and other items not specified but required for the completion of the work, complete as per detailed specification, drawings and directions of the engineer incharge of the works

23.064

114

2645.67144

... More
ele454 - Earth work excavation in Dry fissured Rock / Ordinary Rock/Laterite soil: Supply of all labour, materials, Machineries etc., and excavation with all leads and lifts for tower foundations including back filling with available approved earth/ approved new earth, watering and compaction in layers of 150mm thick, disposal of surplus earth to the places directed, spreading, leveling etc., and other items not specified but required for the completion of the work, complete as per detailed specification, drawings and directions of the engineer incharge of the works.

192.2

120

23150.49

... More
ele455 - Excavation in Hard rock with blasting/ Hard Laterite :Supply of all labour, materials, Machinaries etc., and excavation with all leads and lifts for tower foundations including back filling with available approved earth/ approved new earth, watering and compaction in layers of 150mm thick, disposal of surplus earth to the places directed, spreading, levelling etc., and other items not specified but required for the completion of the work, complete as per detailed specification, drawings and directions of the engineer incharge of the works.

21.736

407

8860.02832

... More
ele456 - Plain Cement concrete 1:3:6: Supply of all labour, materials, tools and plants etc., and providing concrete using 20mm and down size jelly and clean approved sand, machine mixed, concrete laid in layers not exceeding 150mm thick, vibrated, for foundation of lattice type transmission line towers including ply wood/steel centering and shuttering, scaffolding, curing and other items not mentioned here in but required for completion of works as per detailed specification, drawing and directions of engineer incharge of works for different types of tower foundations.

4.36

6987

30465.5

... More
ele457 - Reinforced Cement Concrete 1:1.5:3 (excluding the cost of steel and fabrication charges): Supply of all labour, materials, tools and plants etc., and providing concrete using 20mm and down size jelly and clean approved sand, machine mixed, concrete laid in layers not exceeding 150mm thick, vibrated, for foundation of lattice type transmission line towers including ply wood/steel centering and shuttering, scaffolding, curing and other items not mentioned here in but required for completion of works as per detailed specification, drawing and directions of engineer incharge of works for different types of tower foundations.

74.2

7630

566171.97

... More
ele458 - Providing Steel Reinforcement: Providing and fabricating Reinforcement steel, it shall be tMt bars conforming to IS-1786-2008 (fe 550 grade) and in specific areas mild steel (Grade-I) conforming to IS-432 can also be used. Bidder shall produce test certificates for each lot of reinforcement procured at site. Clear cover as per IS provision shall be left to the reinforcement from the external concrete surface. the scope includes straightening , cutting, bending, hooking, lapping and or welding wherever required, placing in position, tying with binding wire of approved quality and gauge including the cost of binding wire and anchoring to the adjacent member wherever necessary including all laps and wastages etc., complete as per design and specification and directions of Engineer incharge of work for different types of tower foundations.

3062.3

88

269941.745

... More
ele459 - Back filling with available soil

158.43

299

47421.2676

... More
ele460 - 66kV Line (U.G Cable) Module : Each Module Comprising of the following:Sf6 circuit breaker Complete with operating Mechanism, 1600A, 3phase -1NoDisconnector: 3 Phase, Single Pole, Group operated isolator switch complete with manual and motor driven operating mechanism 1250A - 2 Nos.3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism- 2 Nos.3 Phase, Single Pole, fast acting, fault make earthing switch complete with group operated manual and motor driven operating mechanism - 1 No.Current transformer: 3 Core, Multi ratio, single phase current transformer 1200-800/1-1-1A - (1 Set) 3 Nos.Surge Arresters -1Set (3Nos)Bus Bar-Double bus arrangement: Main Bus - 2000AAuxiliary bus -1250ACable end unit (Plug in type) 3 Phase, Single pole, plug in type cable termination - 1 Run of 1000 Sq.mm for each phase - 1 (Set)Gas monitoring device, remote gas pressure transmitters (4-20mA signals) barriers pressure switches etc. as required.Control cable/Power cable/twisted pair screened cable etc (fRLS type) from GIS module to LCC Panel as per technical specification, as required for entire module.

1

16133202

16133202.25

... More
ele461 - Erection Charges

1

229396

229396.4

... More
ele462 - Local Control cubicle for 66kV Line (U.G. Cable) Module as per specification - 1 No.

1

433149

433149.75

... More
ele463 - I) Relay and Protection Panels: a) 66kV Line -type 6L- (Annexure RPP4 -CABLE-SAS) with differential Protection.

1

1640245

1640245.75

... More
ele464 - Erection Charges

1

4505

4505.33

... More
ele465 - testing and Commissioning Charges

1

66432

66432.85

... More
ele466 - Installation, integration, testing and commissioning of CandR panels with SAS supplied by a company for new bay extension with their existing Automation System J.c: All types of 110 kV or 66 kV feeder CandR panels with BCUs

1

227631

227631.25

... More
ele467 - Copper Control Cables :1.1kV class PVC insulated Copper Control Cable with Lugs/ferrules/ Glands as per technical specifications. Note: Quantity of Cable is indicative only. Quantity requirement shall be provided as per site conditions. i) 19 C x 2.5 Sqmm

1000

564

564380

... More
ele468 - Laying Charges

1000

16

16130

... More
ele469 - ii) 10 C x 2.5 Sqmm

1000

336

336480

... More
ele470 - Laying Charges

1000

16

16130

... More
ele471 - ii) 4 C x 2.5 Sqmm

1000

152

152650

... More
ele472 - Laying Charges

1000

16

16130

... More
ele473 - iii) 4 C x 6.0 Sqmm

1500

265

398295

... More
ele474 - Laying Charges

1500

16

24195

... More
ele475 - iv) 4 C x 4.0 Sqmm

500

190

95140

... More
ele476 - Laying Charges

500

16

8065

... More
ele477 - v) 2Px0.5 sq.mm screened twisted pair cable

500

60

30100

... More
ele478 - Laying Charges

500

16

8065

... More
ele479 - Supply of Compact RMU 11KV class 1 OD, 350MVA, 630Amps SF6/VCB Type, MEI Make

10

208505

2085059.3

... More
ele480 - Erection of Compact RMU 11KV class 1 OD, 350MVA, 630Amps SF6/VCB Type, MEI Make

10

5294

52943.6

... More
ele481 - Supply of 4 Way RMU, 2OD + 2VL (One Incomer + Two Breakers + One Outgoing) 630 Amps with Copper Busbar DAS Specification RMU

1

1160127

1160127.1

... More
ele482 - Erection of 4 Way RMU, 2OD + 2VL (One Incomer + Two Breakers + One Outgoing) 630 Amps with Copper Busbar DAS Specification RMU

1

20898

20898

... More
ele483 - Supply of 5 Way RMU, 2 OD + 3 VL (One incomer - Three Breakers + One Outgoing) Compact RMU (VCB/SF6 Type) with Copper Busbar, 350 MVA, 630 Amps

1

1042528

1042528.55

... More
ele484 - Erection of 5 Way RMU, 2 OD + 3 VL (One incomer - Three Breakers + One Outgoing) Compact RMU (VCB/SF6 Type) with Copper Busbar, 350 MVA, 630 Amps

1

25106

25106.62

... More
ele485 - Supply of RMU 3 Way, (2OD + 1VL) One Incomer +One Breakers + One outgoing, 350 MVA, 630 Amps Compact RMU As per Cost data sheet 33

1

606535

606535.42

... More
ele486 - Erection of RMU 3 Way, (2OD + 1VL) One Incomer +One Breakers + One outgoing, 350 MVA, 630 Amps Compact RMU As per Cost data sheet 33

1

15604

15604.7

... More
ele487 - Supply 11 KV 3 core XLPE U.G. Cable 400 Sq.mm (Round Armoured)

11.8

2683703

31667696.58

... More
ele488 - Supply of 11 KV 3 core XLPE U.G. Cable 240 S q . m m (Round Armoured)

0.44

1780251

783310.704

... More
ele489 - Supply of 400 sq.mm U.G. cable tremination kit outdoor type

5

5759

28799.25

... More
ele490 - Supply of 400 sq.mm U.G. cable tremination kit indoor type

30

5176

155283.6

... More
ele491 - Making of cable Termination Kit

35

2857

100007.25

... More
ele492 - Supply of cable Straight through Jointing Kits for 400 Sqmm UG Cable

40

11769

470764

... More
ele493 - Making of cable Straight through Jointing Kits for 400 Sqmm UG Cable

40

3061

122464

... More
ele494 - Supply of 240 sq.mm U.G. cable tremination kit Indoor Type

23

5042

115984.86

... More
ele495 - Making of 240 sq.mm U.G. cable tremination kit Indoor Type

23

2857

65719.05

... More
ele496 - Earth work excavation for cable trench of 0.75 x l cubic meter in ordinary soil

3600

281

1013940

... More
ele497 - Laying of Cable in the existing Trench

0.44

65921

29005.306

... More
ele498 - Labour charges for horizontal drilling with Normail Soil 5/6" bore size

5800

1020

5916986

... More
ele499 - Supply of Cable covering tiles

24000

11

264240

... More
ele500 - Supply of artificial/Manufactured Sand

360

1919

691182

... More
ele501 - c.Refilling and consolidation

3240

172

557280

... More
ele502 - Labour charges for covering the cable with tiles

6

4694

28167.12

... More
ele503 - e.Spreading and forming of sand around the UG cable

6

15920

95524.5

... More
ele504 - Supply of cable Route & Joint indicating stones

244.8

142

34999.056

... More
ele505 - Laying of cable Route & Joint indicating stones

244.8

124

30526.56

... More
ele506 - Supply of Earthing materials pipe type for grounding a s per Drawing BESCOM/GM/CP/15 & No. 34/ Dt: 24.10.07. Single Electrode with accessories

22

1858

40890.74

... More
ele507 - Labour charges for Earthing

22

1020

22443.74

... More
ele508 - Supply of GI Wire 8 SWG

34

80

2742.44

... More
ele509 - Supply of 7/10 SWG Guy Wire

14

83

1162.14

... More
ele510 - Supply of GI pipe 150mm dia for cable rising

48

1993

95666.4

... More
ele511 - Labour charges for laying of GI pipe 150mm dia for cable rising

48

99

4798.56

... More
ele512 - Supply of Danger Board

22

161

3547.5

... More
ele513 - Fixing of Danger Board

22

86

1892

... More
ele514 - Supply of DP Structure using 9 Mtrs RCC Poles of 145Kg WL

10

22498

224980

... More
ele515 - Supply of 11 Mtr long Spun poles 500Kg WL

12

19030

228360

... More
ele516 - Supply of 9 mtr Long RCC pole 145Kg WL

54

7607

410778

... More
ele517 - Supply of Rabbit Conductor for HT side.

7.8

49702

387675.6

... More
ele518 - Supply of H Frame for mounting GOS

10

4657

46570

... More
ele519 - Supply of 11KV 400A Double break GOS

10

22855

228550

... More
ele520 - Supply of 11KV Horizontal Cross arm with clamp bolts nuts etc.

76

524

39824

... More
ele521 - Supply of HTST Support 279092

142

130

18460

... More
ele522 - Supply of 11KV polymeric Pin insulator with(24mm dia FRP Rod).

294

220

64680

... More
ele523 - Supply of 45 kn Polymeric Disc insulator.

132

200

26400

... More
ele524 - Supply of Spiral Earth Electrode for HT Poles.

124

257

31868

... More
ele525 - Supply of Guyset Complete.

16

1258

20128

... More
ele526 - Supply of Concreting meterials for Guyset without cement

16

269

4304

... More
ele527 - Errection of DP Structure using 9 Mtrs RCC Poles of 145Kg WL

10

5796

57960

... More
ele528 - Errection of 11 Mtr long Spun poles(with Base concreting)

12

4783

57396

... More
ele529 - Errection of 9 mtr Long RCC pole

54

1873

101142

... More
ele530 - Releasing & Re erection of 9 mtr Long RCC pole

48

3558

170784

... More
ele531 - Releasing and Re-Fixing of 11KV Horizontal Cross arm with clamp bolts nuts etc.

48

556

26688

... More
ele532 - Releasing and Re-Stringing of Rabbit Conductor

3.8

8907

33846.6

... More
ele533 - Stringing of Rabbit Conductor for HT side.

7.8

8600

67080

... More
ele534 - Fixing of H-Frame for mounting GOS

10

347

3470

... More
ele535 - Fixing of 11KV 400A Double break GOS

10

1305

13050

... More
ele536 - Fixing of 11KV Horizontal Cross arm with clamp bolts nuts etc.

76

292

22192

... More
ele537 - Fixing of HTST Support

142

120

17040

... More
ele538 - Fixing of Spiral Earth Electrode for HT Poles.

124

100

12400

... More
ele539 - Fixing of Guyset Complete.

16

637

10192

... More
ele540 - Releasing of 9/8 Mtr long RCC/PSC Pole.

34

1685

57290

... More
ele541 - Releasing of DP Structutre.

9

5217

46953

... More
ele542 - Releasing of 11 Mtr long Spun pole.

9

4304

38736

... More
ele543 - Releasing of 11 horizontal X arm.

14

263

3682



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.