Airports Authority Of India Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 40,348Document Cost
₹ 1,120Tender Fee
Refer Documents
Summary
Construction Of Double Gate Security System Including Compound Wall, Bollard Security Booth Etc, At Mysuru Airport. Sh-electrical Works
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AAI_203370_1Bid Award Id
ViewTender No
AAI / MYS/ENGG(E)/C.W/Double Gate/2024Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for light/ power plug with 2X4 sq. mm FRLSH PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
240
-
-
Wiring for light/ power plug with 4X4 sq. mm FRLSH PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
60
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
16
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
6 Module (200mmX75mm)
4
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
15/16 A SWITCH
8
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6 pin 15/16 A socket outlet
8
-
-
Supplying and fixing following way, horizontal type three pole and neutral , sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing and suitable cable end box etc. as required. (But without MCB/RCCB/Isolator) 8 way (8+24) Double door
1
-
-
Supplying and fixing following ways surface/recess mounting, vertical type 415 Volts, TPN MCB Distribution Board in sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s , cable end box (but without MCB s and Incomer) as required. 6 way (8+18) Double door
1
-
-
Supplying and fixing following rating Triple Pole and Neutral, 415 volts, C curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 AMPS
2
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 AMPS
2
-
-
Supplying and fixing 5 to 32 amps rating 240/415 Volts, 10 KA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Triple Pole 25 Amps
3
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
27
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
6
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
6
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet RJ 11
6
-
-
Supply of 1400 mm sweep BLDC Ceiling fan, 5 star rated with double ball bearing , standard down rod and other standard accessories suitable for 230 V,50 Hz, single phase AC supply as required.
5
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
5
-
-
Supply of 300 mm dia single phase 900 RPM Heavy Duty Industrial Exhaust fan suitable for 230 V,50 Hz, single phase AC supply including all accessories etc as required.
1
-
-
Supply of 400 mm sweep BLDC wall fan, 5 star rated suitable for 230 V,50 Hz, single phase AC supply as required.
2
-
-
Supply of 20 W surface mounted extruded aluminium LED batten (4 feet) with opal diffuser along with all acessories like heat sink, constant current output driver, reflector, cover etc. complete suitable for operating at 230 V,50 Hz, single phase AC supply as per specifications.
16
-
-
Supply of 15 W surface mounted LED downlignt luminaire with white powder coated pressure die cast aluminium housing and diffuser along with all acessories like heat sink, constant current output driver, reflector, cover etc. complete suitable for operating at 230 V,50 Hz, single phase AC supply as per specifications.
4
-
-
Supply of Integral 45 Watts LED Street Light Luminaire with pressure die cast aluminium housing with IP 66 protection along with all acessories like heat sink, constant current output driver, reflector, glass cover etc. complete suitable for operating at 230 V,50 Hz, single phase AC supply as per specifications.
40
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLSH PVC insulated, copper conductor, single core cable etc. as required.
5
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
1
-
-
Installation of wall fan on surface including connections, testing, commissioning etc. as required.
2
-
-
Installation, testing and commissioning of pre-wired, LED fitting of all types, complete with all accessories directly on ceiling/ wall, including connections with 1.5 sq. mm FRLSH PVC insulated, copper conductor, single core cable and earthing etc. as required.
20
-
-
ITC of Street Light Luminaire on wall with suitable Medium class GI pipe bent to shape including wiring the pipe,making connections etc.complete as required.
4
-
-
Supply of aluminium conductor XLPE insulated, PVC inner sheathed, armoured power cable of 1.1 KV grade conforming to IS-7098 Part 1(1988) amended up to date.
3.5 X 50 sq mm
100
-
-
Supply of XLPE insulated, PVC inner sheathed, armoured copper conductor power cable of 1.1 KV grade conforming to IS-7098 Part 1(1988) amended up to date.
4 X 6 sq mm
200
-
-
Supply of aluminium conductor XLPE insulated, PVC inner sheathed, armoured power cable of 1.1 KV grade conforming to IS-7098 Part 1(1988) amended up to date.
4 X 16 sq mm
600
-
-
Supplying and laying of following size HDPE pipe of PE 80 grade PN 8 pressure rating conforming to IS 4984 -2016 along with all accessories complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
63 mm OD
70
-
-
Supplying and laying of following size HDPE pipe of PE 80 grade PN 8 pressure rating conforming to IS 4984 -2016 along with all accessories complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
50 mm OD
800
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ META/HDPEL pipe as required.
Upto 35 sq. mm
800
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Above 35 sq. mm and up to 95 sq.mm
70
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Above 35 sq. mm and upto 95 sq. mm
15
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
15
-
-
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
3.5x50 sq mm
2
-
-
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
4 core x 6 sq. mm
4
-
-
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
4X16 sq mm
50
-
-
Supplying and fixing 4 pole, Load Break Switch in Sheet Steel Enclosure of following rating conforms to IEC 947-3 AC-23A, Front operated suitable for 415V, 50Hz AC supply as required.
100 Amps
1
-
-
Supplying and fixing Three Phase & Nutral , 200 Amps, 4 Way Busbar chamber suitable for 415Volt 3 phase, 50Hz AC supply fabricated out of sheet steel (CRCA) and epoxy powder coated. The bus bar sections are made of ETP grade copper & tin plated and the bus bar supports are made of DMC. The bus bar chamber shall confirms to IEC-61439-3/IS-8623 & IEC-60529 /IS-2147
1
-
-
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders and rotary handle in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A 25 KA, 4 Pole
1
-
-
Interconnection between existing Four Pole Busbar System/MCCB/Load Break Switch/TPN MCB DB etc. with 4 x 16 sqmm Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volt Conforming to IS 694, copper lugs complete with connections, testing and commissioning etc. as required.
2
-
-
Earthing with copper Earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
2
-
-
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required.
10
-
-
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
20
-
-
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting, sweating and soldering etc as required.
6
-
-
Supply, Installation, Testing and Commissioning of 1.5 TR (nominal capacity), High wall mounted, Inverter Split type Air-conditioner with BEE star rating 5, consisting of non-ductable type indoor units (fan coil) with cord less remote control and one number out door unit comprising of compressor, cooling fan, copper condensing coil suitable for operation on single phase, 230 +/- 10% volts, 50 HZ, AC supply including installing the indoor (fan coil) unit and outdoor unit on wall on suitable stand, providing and fixing insulated copper piping (suction and discharge) and electrical connections with flexible copper cable of suitable size as per manufacturer's recommendations, between the indoor and outdoor units up to a length of 3 (three) meters, wrapping the insulated refrigerant line with white wrapping tape, providing drain piping (up to 3 meter length), drilling the hole on wall, making good the opening after installation including first charge of refrigerant etc. complete as required
3
-
-
Supply, Installaiton, Testing and Commissioning of Voltage stabilizer with initial time delay, high and low voltage cut off suitable for 1.5 TR Inverter type split AC units
3
-
-
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm and disposal of surplus excavated soil as directed, within a lead of 50 metres.
228
-
-
Supply, Installation, Testing and Commissioning of 3 mtr Hot Dip Galvanized Stree Light Pole, Top dia 70mm bottom dia 130 mm with 1 meter single arm on R C C foundation including providing RCC foundation as per Manufacturer's recommendation, opening for cable entry, including foundation bolts, 1 metrer single arm, junction box etc. installaiton of 45 W stree light LED fitting (supply of fitting not included) complete as per specification and as required
25
-
-
Supplying and drawing 2 Core x 1.5 sq.mm PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 in street light poles from junction box to fittings as required.
100
-
-
Evaluation Notes How It Works ?