Agricultural Produce Market Committee Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Agricultural Produce Market Committee - APMC Tender

Works
Civil And Construction
Building Construction
Opening Date7 Feb 2025
Closing Date10 Mar 2025
Tender Amount₹ 12,44,81,343.85 
Notes
Download

Costs

Summary

Construction Of 4480 Mt Capacity Cold Storage At Apmc

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

317.348

5833

1851382.84416

... More
code05 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

192.2777

6403

1231252.174727

... More
code06 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. this rate is inclusive of all formwork for footings concrete

214.9875

7048

1515266.298

... More
code07 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. this rate is inclusive of all formwork for RCC wall concrete

79.5083

7178

570764.643044

... More
code08 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. this rate is inclusive of all formwork for Pedestal concrete

44.1449

11071

488753.350493

... More
code09 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. this rate is inclusive of all formwork for rat band chejja concrete

3.393

10220

34676.52786

... More
code10 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. for flooring in gorund floor

343.2339

7048

2419212.065031

... More
code11 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the for corridor flooring in FIRST FLOOR

35.5795

7118

253282.277215

... More
code12 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. this rate is inclusive of all formwork for sump tank slab concrete

4.3334

10011

43384.26744

... More
code13 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates work with all leads & lifts complete as per specification and as directed by the engineer incharge of the for Lintel Beam Concrete

0.28

11277

3157.6328

... More
code14 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

34.159

92140

3147434.51289

... More
code15 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

64.306

1267

81535.50658

... More
code16 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

36

188

6785.64

... More
code17 - Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1.44

5173

7450.1136

... More
code18 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

9

2711

24407.91

... More
code19 - Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +-1mm), with wall thickness 2.0 mm (+- 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x19 mm and 1mm (+- 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s with all leads & lifts complete as per specification and as directed by the engineer incharge of the work 42x50 mm PVC Extruded section

6

246

1477.02

... More
code20 - Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x2400mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1.89

6432

12157.1415

... More
code21 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

359.11

596

214295.3014

... More
code22 - ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

143

1128

161352.62

... More
code23 - ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Flashings/ Aprons.( Upto 600 mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

198.2

433

85996.998

... More
code24 - Providing and fixing roofing consist of 0.8 mm thick Galvanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. FIRST FLOOR

315.4999

1197

377934.175211

... More
code25 - Providing and fixing roofing consist of 0.8 mm thick Galvanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. SECOND FLOOR

315.4999

1209

381710.709014

... More
code26 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work Ground floor

2910

142

413627.4

... More
code27 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work First floor

2910

143

417759.6

... More
code28 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work Second floor

2910

144

421891.8

... More
code29 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification & as directed by the Engineer incharge of the work. Including providing and fixing GI Perforated Grating for Mezzanine floor. GI Gratings with 30% opening. GI Grating made of GI sheet of 1.6mm/2,mm thick suitable for 1000 kgs UDL suitability is Width of Grating shall be 200 mm X Legnth as per requirement. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

328343.44

140

45994349.0752

... More
code30 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

748.74

118

88688.253

... More
code31 - Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3600

181

652608

... More
code32 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

246.3999

299

73853.442027

... More
code33 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1679.8139

445

749180.201261

... More
code34 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

130.754

321

42019.10544

... More
code35 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing with all leads & lifts complete as per specifications and as per directions of Engineer-in-charge.

107.8099

359

38754.424753

... More
code36 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specifications and as per directions of Engineer-in-charge.

180.664

162

29401.25936

... More
code37 - Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

9.6693

65

637.400256

... More
code38 - Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work .1 HP/0.75kW - 7 STG(stage)

1

13506

13506.39

... More
code39 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments..1x3x2.5 m2 with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

30

87

2626.5

... More
code40 - Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. Upto 7.5 HP centrifugal pump with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

9785

9785

... More
code41 - Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

9

5811

52301.34

... More
code42 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1240

83

103453.2

... More
code43 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

29

597.4

... More
code44 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit CC floor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

71

1421.4

... More
code45 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

36

721

... More
code46 - Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

525

22

11896.5

... More
code47 - Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

50

29

1493.5

... More
code48 - Supplying And Fixing Metal Fan Box with Round Hook. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

120

361.53

... More
code49 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

9

277

2493.63

... More
code50 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3M. upto 6M from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

390

4684.44

... More
code51 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr. upto 10M from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

23

571

13147.95

... More
code52 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

40

697

27892.4

... More
code53 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mtr upto 10Mtr from tapping point to out let via switches with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

15

1018

15280.05

... More
code54 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

650

19

12720.5

... More
code55 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1340

26

35885.2

... More
code56 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1060

43

45855.6

... More
code57 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

450

64

29200.5

... More
code58 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

135

94

12792.6

... More
code59 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 3C x 2.5 mm2 with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

400

116

46556

... More
code60 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

141

564.44

... More
code61 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

178

712.76

... More
code62 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

225

2255.7

... More
code63 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.16Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

302

1816.92

... More
code64 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

180

721

... More
code65 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

241

964.08

... More
code66 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

292

2925.2

... More
code67 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

408

2453.46

... More
code68 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

129

105

13552.74

... More
code69 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps two way. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

170

683.92

... More
code70 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

30

176

5283.9

... More
code71 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

367

1103.13

... More
code72 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

15

185

2781

... More
code73 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

15

243

3646.2

... More
code74 - Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6A Batten Holder. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

76

1524.4

... More
code75 - Supplying of on load change over switches 4poles, AC-23 A Duty,415V,50Hz,AC Supply.With all accessories.(SM Enclosure Sheet Metal Execution) 800 A with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

59912

59912.01

... More
code76 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.700-800 A 50 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

51397

102794

... More
code77 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.500-630 A 50 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

43155

43155.97

... More
code78 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.250 A 25 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

22032

22032.73

... More
code79 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.200 A 25 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

17820

17820.03

... More
code80 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

13850

27700.82

... More
code81 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.125 A 25 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

10651

21302.46

... More
code82 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

1754

5262.27

... More
code83 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

60

427

25647

... More
code84 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

16

761

12178.72

... More
code85 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps TPN. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

1768

10611.06

... More
code86 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

50

3180

159032

... More
code87 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 16 Way SP & N with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

2995

8985.72

... More
code88 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 pole with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

5711

17134.05

... More
code89 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

9532

28597.95

... More
code90 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

9594

28783.35

... More
code91 - Supplying, fixing and wiring 1000/5A to 1600/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

865

2595.6

... More
code92 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

36

530

19096.2

... More
code93 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

2538

15233.7

... More
code94 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

8

3538

28304.4

... More
code95 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.1000 A double run of 4 x 60 x 10 mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

8

10897

87179.2

... More
code96 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40*40*6mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

24

314

7539.6

... More
code97 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

24

406

9764.4

... More
code98 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 75 x 6 mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

571

6859.8

... More
code99 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channel with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

24

778

18688.32

... More
code100 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 150 x 75 x 6 mm C channel with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

953

11445.36

... More
code101 - Supplying and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 60Amps. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

7

6128

42899.5

... More
code102 - Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

175

494

86520

... More
code103 - Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

22289

22289.2

... More
code104 - Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

425000

-

216750

... More
code105 - Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

1369

5479.6

... More
code106 - Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the mete rboard using 40mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and char coal150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

3615

72306

... More
code107 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

200

84

16892

... More
code108 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip Copper strip. 25x3mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

587

11742

... More
code109 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

7643

15287.26

... More
code110 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

400

108

43260

... More
code111 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

16

3

49.44

... More
code112 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

40

4

164.8

... More
code113 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

32

7

230.72

... More
code114 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

36

7

259.56

... More
code115 - Providing and laying in position 100mm dia stone ware pipe in existing trench. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

100

221

22145

... More
code116 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.15" Sweep (450mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

1536

4610.28

... More
code117 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty48" Sweep 5 Star (1200mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

4432

13296.27

... More
code118 - Supplying wall mounting fan suitable to operate at singlephase.400mm Sweep 230v A.C. supply. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

3308

9925.08

... More
code119 - Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 X2' - 9/10w. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

567

1135.06

... More
code120 - Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 X4'- 20/22 w. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

36

710

25585.2

... More
code121 - Supplying of recess/surface mounting non integrated type LED down light . W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly. with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit,THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.15-18W. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

130

1721

223746.9

... More
code122 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 40W. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

4144

49736.64

... More
code123 - Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed forfixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

1239

14869.08

... More
code124 - Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

166

2002.32

... More
code125 - Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

168

125

21110.88

... More
code126 - Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

324

1946.7

... More
code127 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

728

2184.63

... More
code128 - 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.450 x 50 mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

250

940

235097.5

... More
code129 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3.8

146097

555169.588

... More
code130 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.2.5 to 25 Sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3.8

21512

81747.804

... More
code131 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2.3

711954

1637495.442

... More
code132 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 Sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2.3

33246

76466.582

... More
code133 - Heavy Duty Copper Terminal Long Barrel.16/25 Sqmm Copper Terminal, Apprx Wt: 11 Gm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

480

27

13348.8

... More
code134 - Heavy Duty Copper Terminal Long Barrel.185 Sqmm Copper Terminal, Apprx Wt: 158 Gm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

80

282

22577.6

... More
code135 - Brass Cable Gland 25mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

40

81

3254.8

... More
code136 - Brass Cable Gland 40mm.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

152

3048.8

... More
code137 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr (BESCOM SR PART-4,P.NO.8, IT No-29.02) -Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering including cost of labour, tools, usage& other appurtenances required to complete the work. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

180

498

89733.6

... More
code138 - Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

150

59

8961

... More
code139 - 11 kV, 3X240 Sqmm XLPE UG Cable.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.15

1705729

255859.416

... More
code140 - Supply of Straight Through Jointing Kits HS Type suitable for 3x240 Sqmm Cable.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

9075

54451.98

... More
code141 - Supply of Cable termination kit Outdoor HS Type Suitable for 3x240 Sqmm Cable.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

5477

10955.08

... More
code142 - Supply of Cable termination kit Indoor HS Type Suitable for 3x240 Sqmm Cable.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

4831

9663.46

... More
code143 - Supply of Cable Covering Tiles 250x125x40 mm or 125x125x40 mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

500

5

2640

... More
code144 - Supply of Artificial/Manufacture Sand with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

36

1839

66224.88

... More
code145 - Supply of RCC Hume pipe, 2000 mm Long, 150 mm Dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

18

316

5691.78

... More
code146 - Supply of Collars for RCC Hume Pipe.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

18

84

1520.28

... More
code147 - Supply of GI Pipe, 100 mm Dia for drain crossing, cable raising etc., with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

28.7999

1272

36634.912795

... More
code148 - Supply of Route and Joint Indicating Stones.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

136

1643.88

... More
code149 - Cable trench excavation, 1000x0.6x1=600, Ordinary soil with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

360

269

97149.6

... More
code150 - Laying of cable in trench. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.15

66077

9911.6385

... More
code151 - Refilling and consolidation.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

330

164

54384

... More
code152 - Making of straight through joint. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

2933

17600.64

... More
code153 - Making of cable termination.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

2737

10950.96

... More
code154 - Covering the cable with tile.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.15

4498

674.7015

... More
code155 - Spreading Sand and forming with Sand round the cable.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.15

15254

2288.145

... More
code156 - Laying of RCC Hume pipe. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

18

71

1279.26

... More
code157 - Laying of GI Pipe.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

28.7999

95

2758.742421

... More
code158 - Laying of Route and Joint indicating stone.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

12

119

1433.76

... More
code159 - DAS Specification Compact RMU (VCB/SF6 Type) as per IEC-62271 The DAS RMUs shall have the following in addition to the Standards: DC motors, Numerical Relays, Multi- functional meters, fault passage indicator (FPI), Metering CTs, Protection CTs, Auxiliary transformers, Potential transformer, Batteries, Battery chargers (12 V & 24 V), AC power socket and light for illumination of Control panel. Control cable from each panel shall be wired and terminated to suitable 24 pin connector in the control panel. Suitable space for fixing the Remote Terminal Unit (RTU) and Radio Modem in Control panel. Suitable Clamps for fixing Antenna PipeS3 Way RMU, 2OD + 1VL (One Incomer + One Breakers + One Outgoing) 630 Amps with Copper Busbarwith all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

827661

827661.45

... More
code160 - 1 VL for RMU, 630 Amps Copper Busbar.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

305484

305484.9

... More
code161 - Bed Concreting with CC 1:2:4 [M-15] Using 20mm Nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.15

6555

983.2725

... More
code162 - Foundation with CC 1:2:4 [M-15] Using 20mm Nominal size graded crushed coarse aggregateswith all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.6499

6555

4260.191985

... More
code163 - Providing Reinforecement TMT Fe 550/550 D with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

90

76

6898.5

... More
code164 - Providing Plinth with CC 1:2:4 on the Stone Masonary [M-15] Using 20mm Nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.08

6555

524.412

... More
code165 - Construction of Stone Masonary with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.57

6708

3823.8165

... More
code166 - Supplying of Frame of MS Channel 100x50 mm and MS angle 40x40x5 mm welding etc., complete.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

50

71

3570

... More
code167 - Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc.,.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

1009

2018.1

... More
code168 - Earth Excavation for RMU Foundation depositing of earth on bank with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4.92

275

1353.492

... More
code169 - Labour charges for Fixing foundation frame of MS channel 100x50 mm and MS angle 40x40x5 mm welding, fixing in concrete, aligning the RMU on foundation bed, assembly of units, connecting Bus Bars from panel to panel etc., complete.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

5014

20059.2

... More
code170 - Supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.04

916355

36654.2392

... More
code171 - Supply of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3Cx95sqmm indoor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

3856

11568.96

... More
code172 - Supply of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3Cx95sqmm outdoor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

4189

12567.03

... More
code173 - Supply of Cable covering tiles 250x125x40mm.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

150

10

1584

... More
code174 - Supply of River sand. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

1520

9121.68

... More
code175 - Supply of RCC humepipes 2000mm long 150mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

316

3162.1

... More
code176 - Supply of Collars for RCC hume pipes. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

84

844.6

... More
code177 - Supply of GI pipe 150mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

1051

21032.6

... More
code178 - Supply of Route and Joint indicating stones with MS Anchor rod. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

50

136

6849.5

... More
code179 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.3x95 to 150 Sqmm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.04

63161

2526.4664

... More
code180 - Refilling the cable trenches with selected availble earth from trench excavation including watering,Consolidation in layers of 15Cm thickness including depositing of the surplus earth with a lead of 200Mtrs. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

40

59

2389.6

... More
code181 - Making and Fixing pot head for HT Cable only.Heat shrinkable Type Terminations.3x95 to 3x150 Sqmm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

2737

10950.96

... More
code182 - Covering the cables with tiles. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.4

4498

1799.204

... More
code183 - Spreading and forming with sand alround the cable to a depth of 75mm and width of 500mm . with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

0.4

15254

6101.72

... More
code184 - Laying and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortor complete.RCC Pipe..

10

71

710.7

... More
code185 - Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

95

1915.8

... More
code186 - Fixing of Route Joint Indicating Slab.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

50

119

5974

... More
code187 - 11kV HT Metering cubical of different CT Ratio Both side entry type with 3CT & 3PTs with transparent cover TTB,with 30x8mm Copper Bus bars,modem and 2nos of Meters for 3 Phase 4 Wire Metering WITHOUT Load break Switch (HT Metering Box Fabricated out of 3mm MS Sheet duly epoxy powder coated)as per revised specification.Dwg No.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

250776

250776.16

... More
code188 - Erection of HT metering Cubicle on Platform. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

1899

1899.32

... More
code189 - Construction of platform (1.5x1.5x1.2) mtr in size stone,cement concrete for erection of Metering cubical,Transformer and Load break switch: Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6. Providing cement concrete Slab(1.5x1.5x0.10)Mtr with cement concrete 1:2:4 mix forming and cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

33991

101973.09

... More
code190 - Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014.21. 500 kVA, Aluminium Wdg, Star 2 (5 Star). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

941192

941192.37

... More
code191 - Erection of 300 - 500 kVA Transformer. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

3177

3177.55

... More
code192 - Providing chain link fencing 50mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

115262

115262.15

... More
code193 - Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is tobe established through GI wire of size as per lSI specification 7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

3615

21691.8

... More
code194 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

4383

43836.8

... More
code195 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

60

84

5067.6

... More
code196 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 50x6mm GI strip with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

30

224

6736.2

... More
code197 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm Copper strip with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

587

11742

... More
code198 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm Copper strip with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

1133

22660

... More
code199 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.600 x 600 x 3 mm Copper plate with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

7643

45861.78

... More
code200 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

50

59

2987

... More
code201 - Solar Photovoltaic Power Plant:-Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work for each kwp

50

57028

2851400.5

... More
code202 - Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.82.5 KVA to 125 KVA. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

112816

112816.93

... More
code203 - Supplying, installing, testing and commissioning of PRIME Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specifications.Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation.Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation.Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment,Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation,(continue Reffer as per tender document and schedule B)

1

1646136

1646136.73

... More
code204 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3000

83

250290

... More
code205 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

29

597.4

... More
code206 - Supplying and drawing of 2 CoreX1.5 Sqmm coppe rconductor armoured cable with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3200

154

494400

... More
code207 - Supply,installation,testing and commissioning of analogue addressable Smoke Sensor detector and standard base(ForDetectors/Device without in built isolator,Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

162

3399

550638

... More
code208 - Supplying Installing, testing and commissioning of electronic Hooter, it conists of electronic circuit to give dual Fire alaram sound with works.24V DC with speaker all encased in suitable in MS 16 gauge red painted box.complete including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

1545

4635

... More
code209 - Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

1545

4635

... More
code210 - Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

154

463.5

... More
code211 - Addresable Smoke Detection- Wired.Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character / 240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126 /240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50 Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. Make:Advanced (UK), Argus,( Uk) Simplex, Notifie 2 Loop Panel.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

216300

216300

... More
code212 - Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc.complete including cost of materials,labour,usage charges of machinery complete as per specifications..with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

2575

7725

... More
code213 - Supplying Installing,testing and commissioning of Public address system(Two way comminication type)as per requirement of Fire Force authority and which Generally comprise of Supplying Installing,testing and commissioning of Approved make 6W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc.complete including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

2523

7570.5

... More
code214 - Supplying Installing,testing and commissioning of P.A.System console panel with push button with speaker and indictor on Accomdated in M.S.Cabinet with painting including cost of materials,labour,usage charges of machinery complete as per specifications.10 Zone cansole with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

36050

36050

... More
code215 - P.A.System amplifier 250W RMS output with complete wiring and controls accessable form front with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

36307

36307.5

... More
code216 - Supplying Installing,testing and commissioning of MIKEsuitable to I.A.System. Complete.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

5665

5665

... More
code217 - Supplying of four bucket stand along with buckets. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

1905

1905.5

... More
code218 - Supplying of Hand gloves. Complete..with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

1004

2008.5

... More
code219 - Supplying of first aid box. Complete..with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

618

618

... More
code220 - Supplying of SAFETY MASK. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

154

309

... More
code221 - Supplying of FIRST AID CHART with lamination.Complete with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

412

412

... More
code222 - Supplying and installation of RUBBER MAT 1mtrx1mtr-1Omm thick.complete including cost of materials,labour,usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

1957

3914

... More
code223 - Providing ABC Powder based MAP 50, 2Kg.Providing 2kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal),Range minimum 2 meters, applicable on Class A,8, C and electrically started Fire, A Rating 1A, 8 Rating 88, Can construction : Deep drawn & Co. , Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683, CE Approved..with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

42

2163

90846

... More
code224 - Providing's Escape Singage Photo lumines centrigid plastic,2mm thickness,Printed on High Quality glass paint with UV resistance,5years warranty,Material Used-Non Radiocactive,non phosphorous,non toxic and lead free.Available in different types & sizes,Time after removing the light source (inminutes) 60minutes,Luminescent intensity (milicandelas*persquaremeter-mcd/sqm):30mcd/sqm.Luminescent Intensity greater than 0.32mcd/sqm,Period of Light Decay*(InMinutes):3100, including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

2575

7725

... More
code225 - Providing and Fixing evacuation plan of size A3 made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc.complete including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

3

6695

20085

... More
code226 - Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering,adequate 2280 LPM and 70m head at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories,neoprine gaskets (16 kg/sq.cm) Control panel is excluded.Required GA drawing for the pump/ foundation shall be submitted by the contractor.

1

293550

293550

... More
code227 - Supply, erection, testing and commissioning of Fire Fighting panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted, degreased,phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners. The switchboards are to be tested as per IS 8623-1977 specifications. Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

286340

286340

... More
code228 - Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 3.5C x 120 sq.mm for main pumps with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

470

4705

... More
code229 - Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 3.5C x 95 sq.mm for main pumps with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

384

3844

... More
code230 - Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 2 C x 2.5 Sqmm.for Instrumentation (Cu) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

5

64

320.1

... More
code231 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 200mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

5

5047

25235

... More
code232 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 150mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

5

4429

22145

... More
code233 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding,Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. 150mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

5

4017

20085

... More
code234 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding,Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. 25mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

5

721

3605

... More
code235 - Supplying installing, testing and commissioning of PN16 CI "Non Return Valve " confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading andunloading transportation etc complete. ---- etc., complete as per specificaitonwith all lead and lift, loading unloading, labour, hire charges of machineriesand all such incidental charges necessary for successful completion of workand as per directions of the Engineer-in-charge of the work 200 mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

14420

14420

... More
code236 - Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc.,complete ---- etc.,complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary forsuccessful completion of work and as per directions of the Engineer-in-chargeof the work 150mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

12875

12875

... More
code237 - supply and installing testing and commissioning of CI " Y " stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such in cidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 200mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

25235

25235

... More
code238 - Supplying, installing , testing and commissioning approved make CI Gate valves as per IS: 780 / 14846 with flanges, bolts, nuts, washers, gaskets etc. complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 200mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

40878

40878.64

... More
code239 - Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 15mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

978

978.5

... More
code240 - Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 25 mm dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

1236

1236

... More
code241 - Pressure Switch including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. ---- etc., complete as per specificaiton with all lead and lift, loadi g unloading, labour, hire charges of machineries and all such incidental charges necessary for successful comp with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

2008

2008.5

... More
code242 - Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

2987

2987

... More
code243 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 150mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

100

4017

401700

... More
code244 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 100mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

30

2935

88065

... More
code245 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 80mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

30

2369

71070

... More
code246 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 25mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

721

7210

... More
code247 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m,80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 200mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

10

4429

44290

... More
code248 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m,80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 80mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

20

2369

47380

... More
code249 - Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc.,complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 150mm nominal dia (For Risers) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

12875

25750

... More
code250 - Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc.,complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 100mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

4

9270

37080

... More
code251 - Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

10815

64890

... More
code252 - Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

5150

30900

... More
code253 - Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

4635

27810

... More
code254 - Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

5356

32136

... More
code255 - Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

6

6180

37080

... More
code256 - Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodate 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials,labour, usage charges of machinery complete as per specifications with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

6695

40170

... More
code257 - Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

1

33990

33990

... More
code258 - Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour,usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

1545

3090

... More
code259 - Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 25mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work

2

1236

2472

... More
code260 - Providing SUPPLYING. INSTALLATION, TESTING and COMMISSIONING of Goods Lifts for Ground +2 Floor Capacity : 1000 Kgs, Platform size : 1600 L X 1600 W mm X 2100 H, Maximum height : 4000 mm, Min Height : 300 mm, Lift Height : 3700 mm, No of Mast Pairs : 1, No of cylinders : 1 cabin platform made of M.S. checkered plate 5mm thick with one coat of primer & two coats of enamel paint the cost includes of necessary M.S Frame work & with all accessories for the smooth operation of goods lift including all necessary fittings, equipment’s , cost of materials, Formwork, labour, usage charges of machinery with all leads & lifts complete as per specification & as directed by the Engineer in charge of the work.

1

770000

770000

... More
code261 - Supply. installation, testing and commissioning of plant and equipment for cold stores as per the specifications. Product to be stored multi commodities(1)Cold rooms shall be constructed using 80mm thick Prefabricated Rigid Polyurethane Foam (RPUF) insulated panels laminated with Pre-Painted Galvanised Steel (PPGS) lamination on inside and outside inside with serrations for the walls & roofing. The wall to wall & roofing joinery shall be with Tongue and Groove arrangement. The wall to roof joinery shall be held using flashing from inside & outside. All the resulting panel joinery shall be applied with silicon sealant. (2)The floor insulation shall be constructed using 60mm thick RPUF insulated panels laminated with 250 micron thick polythene sheet lamination acting as vapor barrier on both sides. (3)The Roof insulation shall be constructed using 80mm thick Roof Panels shall be pre- fabricated roofing panels made of Rigid Polyurethane Heat Terminating Roof Foam (RPUF) sandwiched between layers of waterproof and non-corrosive material (4)The doors (3Nos) shall be Manual Sliding type of size 1.80mx2.4m-80mm thick in the corridor in each flloor and Hinged type doors (30Nos) of size 1.2mx2.1m-80mm thick in the rooms. Door shall be provided with internal safety release mechanism and hooter switch. (5) The refrigeration system shall be Freon based split type of 15KW capacity -No. of units 20Nos(2 Nos in each room) with Air Cooled Condensing Units located outside the room and the Evaporator Units located inside the room. The condensing unit shall house suitable capacity hermetic compressor for the rooms, condenser coil and fans. Weather proof electrical starter panel for the full unit shall be mounted inside the condensing unit. (6) The evaporator shall be constructed using GI casing & condenser cabin shall be constructed using GI casing. All the refrigerant tubes shall be with copper construction & Al fins. The evaporator shall be provided with suitable fin spacing to allow sufficient frost build up to enable longer operation hrs between defrost. Defrost shall be automatic. The drain tray has been provided with additional heaters to avoid ice buildup. Capacity of Evaporator unit 15kW No. of units 20Nos (2 Nos for each room 2 10 rooms) (7)The interconnecting copper piping shall be generously designed to minimize the pressure drop in the system. (8) Type of light fitting High bay LED vapor proof fittings suitable for cold rooms. (9)Ambient Temperature [in C] 25Deg C40 Deg C (10) Designed Room Temperature (+) 2 to (+) 8 Deg C (11) Designed Room Humidity [% RH] In the range 70 to 85% with 5% Variation (12) Type of refrigeration system Split Type-Individual Refrigeration system (13) Type of Refrigerant R404a (14) Type of Compressor Hermetic (15) Type of Condenser Air-Cooled (16) Temperature / humidity indicator-cum-controller Micro-Processor based controller shall be provided (17)Interconnecting piping and wiring between the Condenser and Evaporator units as required (18) No Cold Rooms in each Floor 10 Nos (Ground Floor + 2 Floor) ( size of each room as shown in the Drawings) (19) The compressor on/off based on the load shall be controlled by a micro processor based digital temperature controller which shall also control the defrost cycle, on/off of fans, fault indications etc, thereby controlling the entire refrigeration system. Complete with all leads & lifts complete as per specification and as direted by the Engineer incharge of the work. For detailed technical specification refer annexure in KW4 bid document

1

44165671

44165671



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.