Agricultural Produce Market Committee Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Agricultural Produce Market Committee - APMC Tender

Works
Civil And Construction
Civil Works Others
Opening Date8 Feb 2025
Closing Date10 Mar 2025
Tender Amount₹ 9,50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

80.0072

6527

522275.00052

... More
code05 - Providing and laying in position Cement Concrete for all Foundation works. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts complete as per specification and as directed by the engineer incharge of the work. this rate inclusive of all formwork for footings concrete

157.3017

7185

1130215.860534

... More
code06 - Providing and laying in position Cement Concrete for all Foundation works. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. this rate inclusive of all formwork for RCC wall concrete

38.0159

7318

278203.397472

... More
code07 - Providing and laying in Cement Concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts complete as per specification and as directed by the engineer incharge of the work. this rate inclusive of all formwork for Pedestal concrete

21.2625

11566

245939.085

... More
code08 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts complete as per specification and as directed by the engineer incharge of the work. this rate inclusive of all formwork for Rat band concrete

3.105

10418

32349.3183

... More
code09 - Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts complete as per specification and as directed by the engineer incharge of the work. this rate inclusive of all formwork for sump tank slab concrete

4.3334

10206

44226.6804

... More
code10 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND & FIRST FLOOR with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. for flooring concerte

153.6418

7185

1103939.37927

... More
code11 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SECOND FLOOR with all leads and lifts complete as per specification and as directed by the engineer incharge of the work. for deck slab concrete in first floor

20.0362

7257

145402.7034

... More
code12 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts complete as per specification and as directed by the Engineer incharge of the work. This rate is inclusive of all form work for Lintel Beam concrete

0.28

11496

3218.9472

... More
code13 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates THIRD FLOOR with all leads and lifts complete as per specification and as directed by the engineer incharge of the work. for deck slab concrete in second floor

20.0362

7328

146842.30437

... More
code14 - Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping or welding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all leads and lifts complete as per specification and as directed by the engineer incharge of the work.

19.759

93929

1855959.90615

... More
code15 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg per m3 and minimum compressive strength of 4.00 N per mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc with all leads and lifts complete as per specification and as directed by the engineer incharge of the work.

56.896

1292

73540.9248

... More
code16 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

9

2764

24881.85

... More
code17 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

36

192

6917.4

... More
code18 - Providing & fixing of 2-track x2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets-grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) with all leads & lifts complete as per specification & as directed by the Engineer incharge of the work.

1.44

5274

7594.776

... More
code19 - Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerancePlus-minus 1mm), with wall thickness 2.0 mm (Plus-minus 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm plus-minus 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section with all leads & lifts complete as per specification & as directed by the Engineer incharge of the work.

6

250

1505.7

... More
code20 - Providingand fixing of Openable door made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mmx55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mmx102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mmx34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge and Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all leads & lifts complete as per specification & as directed by the Engineer incharge of the work

1.89

6557

12393.2025

... More
code21 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

253.4717

454

115240.908405

... More
code22 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

490.353

279

136955.5929

... More
code23 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (plus or minus 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. THIRD FLOOR ROOF

436.902

614

268384.52958

... More
code24 - ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. THIRD FLOOR ROOF

70

1161

81307.1

... More
code25 - ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Flashings/ Aprons.( Upto 600 mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. THIRD FLOOR ROOF

120

446

53598

... More
code26 - Providing and fixing roofing consist of 0.8 mm thick Galvanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. FIRST FLOOR

194.362

1221

237345.1563

... More
code27 - Providing and fixing roofing consist of 0.8 mm thick Galvanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. SECOND FLOOR

194.362

1233

239718.31632

... More
code28 - Providing and fixing roofing consist of 0.8 mm thick Galvanized steel Deck Sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. THIRD FLOOR

194.362

1245

242091.47634

... More
code29 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. Ground floor with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1136

144

164606.4

... More
code30 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. First floor with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1136

146

166242.24

... More
code31 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. Second floor with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1136

147

167889.44

... More
code32 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1136

149

169536.64

... More
code33 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

231772

142

33097041.6

... More
code34 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

117.976

327

38648.9376

... More
code35 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

96.0599

366

35201.150355

... More
code36 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. (The gloss should be 50% @ 60 degree angle with 10 years life)

156.136

165

25902.9624

... More
code37 - Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1500

184

277200

... More
code38 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

180

305

54999

... More
code39 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

399.96

120

48295.17

... More
code40 - Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

9.6693

67

649.77696

... More
code41 - Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete.1 HP/0.75kW - 7 STG(stage) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

13768

13768.65

... More
code42 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments..1x3x2.5 m2 with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

30

89

2677.5

... More
code43 - Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. Upto 7.5 HP centrifugal pump with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

9975

9975

... More
code44 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. HDPE Grade PE80-PN6.0,110mm dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

120

492

59094

... More
code45 - Supplying installing, testing and commissioning of PN16 CI "Non Return Valve " confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading andunloading transportation etc complete. etc., complete as per specificaitonwith all lead and lift, loading unloading, labour, hire charges of machineriesand all such incidental charges necessary for successful completion of workand as per directions of the Engineer-in-charge of the work 150 mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

7476

7476

... More
code46 - Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

5924

5924.1

... More
code47 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1310

85

111415.5

... More
code48 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

30

609

... More
code49 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit CC floor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

72

1449

... More
code50 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

36

735

... More
code51 - Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

480

23

11088

... More
code52 - Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

50

30

1522.5

... More
code53 - Supplying And Fixing Metal Fan Box with Round Hook. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

122

491.4

... More
code54 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

282

1694.7

... More
code55 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3M. upto 6M from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

397

3979.5

... More
code56 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr. upto 10M from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

24

582

13986

... More
code57 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

44

710

31277.4

... More
code58 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mtr upto 10Mtr from tapping point to out let via switches with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

22

1038

22845.9

... More
code59 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

750

19

14962.5

... More
code60 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2200

27

60060

... More
code61 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2160

44

95256

... More
code62 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

435

66

28775.25

... More
code63 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

315

96

30429

... More
code64 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 3C x 2.5 mm2 with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

220

118

26103

... More
code65 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

143

863.1

... More
code66 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

181

1089.9

... More
code67 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

229

2759.4

... More
code68 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.16Way with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

308

3704.4

... More
code69 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

183

1102.5

... More
code70 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

245

1474.2

... More
code71 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

298

3578.4

... More
code72 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

416

5002.2

... More
code73 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

146

107

15636.6

... More
code74 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps two way. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

174

1743

... More
code75 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

40

179

7182

... More
code76 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

374

1499.4

... More
code77 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

16

189

3024

... More
code78 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

16

247

3964.8

... More
code79 - Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6A Batten Holder. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

77

1554

... More
code80 - Supplying of on load change over switches 4poles, AC-23 A Duty,415V,50Hz,AC Supply.With all accessories.(SM Enclosure Sheet Metal Execution) 400 A with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

34589

34589.1

... More
code81 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.400-500 A 50 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

43571

87143.7

... More
code82 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.200 A 25 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

18166

18166.05

... More
code83 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

14119

14119.35

... More
code84 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.125 A 25 kA with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

10858

10858.05

... More
code85 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

3

1788

5364.45

... More
code86 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

76

435

33117

... More
code87 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

775

7759.5

... More
code88 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps TPN. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

1802

10817.1

... More
code89 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

30

3242

97272

... More
code90 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 16 Way SP & N with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

3053

12213.6

... More
code91 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 pole with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

5822

23289

... More
code92 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

3

9717

29153.25

... More
code93 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

3

9780

29342.25

... More
code94 - Supplying, fixing and wiring 1000/5A to 1600/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

3

882

2646

... More
code95 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

36

540

19467

... More
code96 - Supplying......amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

2588

15529.5

... More
code97 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

8

3606

28854

... More
code98 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.400 A 4 x 50 x 10 mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

8

4667

37338

... More
code99 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

18

320

5764.5

... More
code100 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

18

414

7465.5

... More
code101 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 75 x 6 mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

582

6993

... More
code102 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channel with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

24

793

19051.2

... More
code103 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 150 x 75 x 6 mm C channel with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

972

11667.6

... More
code104 - Supplying and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 60Amps. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

6247

24990

... More
code105 - Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

75

504

37800

... More
code106 - Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

22722

22722

... More
code107 - Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

410000

-

213200

... More
code108 - Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

1396

2793

... More
code109 - Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the mete rboard using 40mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and char coal150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

18

3685

66339

... More
code110 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

200

86

17220

... More
code111 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip Copper strip. 25x3mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

40

598

23940

... More
code112 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

7792

15584.1

... More
code113 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

200

110

22050

... More
code114 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

16

3

50.4

... More
code115 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

40

4

168

... More
code116 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

32

7

235.2

... More
code117 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

36

7

264.6

... More
code118 - Providing and laying in position 100mm dia stone ware pipe in existing trench. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

100

225

22575

... More
code119 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.15" Sweep (450mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

1566

6266.4

... More
code120 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W plus or minus 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 plus or minus 10% RPM, Rated air delivery 210 plus or minus 10% Cubic Meter Minimum, Rated service value greater than or equle to 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty48" Sweep 5 Star (1200mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

4518

18072.6

... More
code121 - Supplying wall mounting fan suitable to operate at singlephase.400mm Sweep 230v A.C. supply. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

3372

13490.4

... More
code122 - Supplying of ..... feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x 2' - 9/10w. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

578

2314.2

... More
code123 - Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

80

724

57960

... More
code124 - Supplying of recess/surface mounting non integrated type LED down light ...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per watt, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit,THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.15-18W with all leads & lifts complete as per specification and as directed by the engineer incharge of the work..

100

1754

175455

... More
code125 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 130lm/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 40W. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

4225

42252

... More
code126 - Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed forfixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

1263

12631.5

... More
code127 - Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

170

1701

... More
code128 - Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

184

128

23570.4

... More
code129 - Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

8

330

2646

... More
code130 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

742

2969.4

... More
code131 - 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.450 x 50 mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

250

958

239662.5

... More
code132 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2.3

148934

342548.43

... More
code133 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.2.5 to 25 Sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2.3

21930

50439.69

... More
code134 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1.2

725778

870934.68

... More
code135 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 Sqmm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1.2

33891

40670.28

... More
code136 - Heavy Duty Copper Terminal Long Barrel.16/25 Sqmm Copper Terminal, Apprx Wt: 11 Gm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

480

28

13608

... More
code137 - Heavy Duty Copper Terminal Long Barrel.185 Sqmm Copper Terminal, Apprx Wt: 158 Gm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

40

287

11508

... More
code138 - Brass Cable Gland 25mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

82

1659

... More
code139 - Brass Cable Gland 40mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

155

3108

... More
code140 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr (BESCOM SR PART-4,P.NO.8, IT No-29.02) -Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering including cost of labour, tools, usage & other appurtenances with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

180

508

91476

... More
code141 - Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with all leads & lifts complete as per specification and as directed by the engineer incharge of the work..

150

60

9135

... More
code142 - Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

21974

21974.4

... More
code143 - fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

5640

5640.6

... More
code144 - Supply of 11 kV, 45 KN Polymeric Insulator. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

195

1171.8

... More
code145 - Supply of Guy Set Complete with No. 15 Strain Insulator & Concreting materials.Supply of Guy Clamp -GI. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

120

241.5

... More
code146 - Supply of Turn Buckle (GI)(Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

253

506.1

... More
code147 - Supply of Anchor Rod using 12 mm rounds/Guy Rod - GI. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

345

690.9

... More
code148 - Supply of No. 15 Strain Insulator. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

61

123.9

... More
code149 - Supply of Guy Wire & GI Wire as per IS-2141.7/10 SWG Guy Wire(7/3.251 mm Dia), Std Wt: 680 Kg/KM. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.01

81087

810.873

... More
code150 - Digging of Pit for GUY SET.Ordinary Soil. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

343

686.7

... More
code151 - Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

279

558.6

... More
code152 - supply of Spiral Earth Electrode. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

250

501.9

... More
code153 - Providing Spiral Earth Electrode type earthing. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

97

195.3

... More
code154 - Supply of Caution/Danger Board. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

157

315

... More
code155 - fixing of Caution/Danger Board. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

84

168

... More
code156 - Supply of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

93

186.9

... More
code157 - fixing of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

44

88.2

... More
code158 - Supply of 11 kV, 400 Amps Double Break GOS(Dwg No. BESCOM/GM/QS&S/22 Dtd 24.11.2018). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

22323

22323

... More
code159 - Fixing of GOS including wiring (11 kV Double Break 400 Amps). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

1274

1274.7

... More
code160 - Supply of Single H Frame without Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole for 63/100/250/500kVA (OH Line) - GI. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

18886

18886.35

... More
code161 - Erection of H-Frame.for mounting GOS. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

339

339.15

... More
code162 - Supply of 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

6168

6168.75

... More
code163 - Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

248

248.85

... More
code164 - 11 kV, 3X240 Sqmm XLPE UG Cable. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.2

1738850

347770.08

... More
code165 - Supply of Straight Through Jointing Kits HS Type suitable for 3x240 Sqmm Cable. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

9251

55509.3

... More
code166 - Supply of Cable termination kit Outdoor HS Type Suitable for 3x240 Sqmm Cable. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

5583

11167.8

... More
code167 - Supply of Cable termination kit Indoor HS Type Suitable for 3x240 Sqmm Cable. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

4925

9851.1

... More
code168 - Supply of Cable Covering Tiles 250x125x40 mm or 125x125x40 mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

500

5

2690

... More
code169 - Supply of Artificial/Manufacture Sand with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

36

1875

67510.8

... More
code170 - Supply of RCC Hume pipe, 2000 mm Long, 150 mm Dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

18

322

5802.3

... More
code171 - Supply of Collars for RCC Hume Pipe. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

18

86

1549.8

... More
code172 - Supply of GI Pipe, 100 mm Dia for drain crossing, cable raising etc., with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

28.7999

1296

37346.270325

... More
code173 - Supply of Route and Joint Indicating Stones with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

139

1675.8

... More
code174 - Cable trench excavation, 1000x0.6x1=600, Ordinary soil with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

360

275

99036

... More
code175 - Laying of cable in trench. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.2

67360

13472.13

... More
code176 - Refilling and consolidation.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

330

168

55440

... More
code177 - Making of straight through joint with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

2990

17942.4

... More
code178 - Making of cable termination. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

2790

11163.6

... More
code179 - Covering the cable with tile.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.2

4585

917.07

... More
code180 - Spreading Sand and forming with Sand round the cable. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.2

15550

3110.1

... More
code181 - Laying of RCC Hume pipe.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

18

72

1304.1

... More
code182 - Laying of GI Pipewith all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

28.7999

97

2812.310235

... More
code183 - Laying of Route and Joint indicating stone.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

12

121

1461.6

... More
code184 - DAS Specification Compact RMU (VCB/SF6 Type) as per IEC-62271 The DAS RMUs shall have the following in addition to the Standards: DC motors, Numerical Relays, Multi- functional meters, fault passage indicator (FPI), Metering CTs, Protection CTs, Auxiliary transformers, Potential transformer, Batteries, Battery chargers (12 V & 24 V), AC power socket and light for illumination of Control panel. Control cable from each panel shall be wired and terminated to suitable 24 pin connector in the control panel. Suitable space for fixing the Remote Terminal Unit (RTU) and Radio Modem in Control panel. Suitable Clamps for fixing Antenna PipeS3 Way RMU, 2OD plus 1VL (One Incomer plus One Breakers plus One Outgoing) 630 Amps with Copper Busbar. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

827661

827661.45

... More
code185 - Bed Concreting with CC 1:2:4 [M-15] Using 20mm Nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.15

6555

983.2725

... More
code186 - Foundation with CC 1:2:4 [M-15] Using 20mm Nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.6499

6555

4260.191985

... More
code187 - Providing Reinforecement TMT Fe 550/550 D with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

90

76

6898.5

... More
code188 - Providing Plinth with CC 1:2:4 on the Stone Masonary [M-15] Using 20mm Nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.08

6555

524.412

... More
code189 - Construction of Stone Masonary with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.57

6708

3823.8165

... More
code190 - Supplying of Frame of MS Channel 100x50 mm and MS angle 40x40x5 mm welding etc., complete.with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

50

71

3570

... More
code191 - Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc.,with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

1009

2018.1

... More
code192 - Earth Excavation for RMU Foundation depositing of earth on bank with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4.92

275

1353.492

... More
code193 - Labour charges for Fixing foundation frame of MS channel 100x50 mm and MS angle 40x40x5 mm welding, fixing in concrete, aligning the RMU on foundation bed, assembly of units, connecting Bus Bars from panel to panel etc., complete..with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

5014

20059.2

... More
code194 - Supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia).with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.04

934149

37365.972

... More
code195 - Supply of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3Cx95sqmm indoor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

3

3931

11793.6

... More
code196 - Supply of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3Cx95sqmm outdoor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

3

4270

12811.05

... More
code197 - Supply of Cable covering tiles 250x125x40mm.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

150

10

1614

... More
code198 - Supply of River sand. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

1549

9298.8

... More
code199 - Supply of RCC humepipes 2000mm long 150mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

322

3223.5

... More
code200 - Supply of Collars for RCC hume pipes. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

86

861

... More
code201 - Supply of GI pipe 150mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

1072

21441

... More
code202 - Supply of Route and Joint indicating stones with MS Anchor rod. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

50

139

6982.5

... More
code203 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.3x95 to 150 Sqmm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.04

64388

2575.524

... More
code204 - Refilling the cable trenches with selected availble earth from trench excavation including watering,Consolidation in layers of 15Cm thickness including depositing of the surplus earth with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

40

60

2436

... More
code205 - Making and Fixing pot head for HT Cable only.Heat shrinkable Type Terminations.3x95 to 3x150 Sqmm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

2790

11163.6

... More
code206 - Covering the cables with tiles. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.4

4585

1834.14

... More
code207 - Spreading and forming with sand alround the cable to a depth of 75mm and width of 500mm. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

0.4

15550

6220.2

... More
code208 - Laying and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortor complete.RCC Pipe.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

72

724.5

... More
code209 - Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

97

1953

... More
code210 - Fixing of Route Joint Indicating Slab.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

50

121

6090

... More
code211 - Providing Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of Distribution Transformer Center.supply of LT CT's 0.5 Accuracy Class Ring Type Ratio 400/5 for 250 kVA DTC. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

612

1224.3

... More
code212 - Fixing of Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of Distribution Transformer Center.fixing of LT CT's 0.5 Accuracy Class Ring Type Ratio 400/5 for 250 kVA DTC. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

110

220.5

... More
code213 - supply of Electronic Trivector Meter 3 Phase, 4 Wire, 0.5 Accuracy Class. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

3565

7131.6

... More
code214 - fixing of Electronic Trivector Meter 3 Phase, 4 Wire, 0.5 Accuracy Class. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

504

1008

... More
code215 - supply of Weather Proof, Verming Proof LT Metering Box with clamping arrangement for mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the existing ground. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

3826

7652.4

... More
code216 - fixing of Weather Proof, Verming Proof LT Metering Box with clamping arrangement for mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the existing ground. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

577

1155

... More
code217 - Load Break switches with Panel. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

76900

153801.9

... More
code218 - Erection Alignment and fixing of Load break switch on the platform. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

2

2181

4363.8

... More
code219 - Construction of platform (1.5x1.5x1.2) mtr in size stone,cement concrete for erection of Metering cubical,Transformer and Load break switch: Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6. Providing cement concrete Slab(1.5x1.5x0.10)Mtr with cement concrete 1:2:4 mix forming and cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

34651

138604.2

... More
code220 - Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014.21. 250 kVA, Aluminium Wdg, Star 2 (5 Star). with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

569830

569830.8

... More
code221 - Erection of 200 - 250 kVA Transformer. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

2391

2391.9

... More
code222 - Providing chain link fencing 50mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

104977

104977.95

... More
code223 - Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is tobe established through GI wire of size as per lSI specification 7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

3685

22113

... More
code224 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

10

4468

44688

... More
code225 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

60

86

5166

... More
code226 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 50x6mm GI strip

30

228

6867

... More
code227 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm Copper strip with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

598

11970

... More
code228 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm Copper strip with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

20

1155

23100

... More
code229 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.600 x 600 x 3 mm Copper plate. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

6

7792

46752.3

... More
code230 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

50

60

3045

... More
code231 - Solar Photovoltaic Power Plant:-Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. AS PER KWP

25

58135

1453383.75

... More
code232 - Supplying,installing,testing andcommissioningofPRIMEDiesel Generator set with following specifications. Power rating as per standard referenceconditionasper-S5514/ISO 3046/ ISO 8528 & IS 1002/ISO3046Generator set specifications.Engine:Diesel generating set are rated at 1500RPM and conform toISO 8528 specifications.he engines are radiator cooled, four stroke and multi cylinder, conforming toISO3046 Thescope f supply includes:Electrical starter motor 12V DC Battery charging alternatorBoschfuel systemwith mechanical governor,A1Class.Spin-on lube oil filterSpin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner,Shutoff coil,Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure,Safety forhigh water temperature, Permissible overload of 10% for one hour in 12 hours of operation.Capacity of Fuel TankFuel tank suitable for 8 hours ofoperation.Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVMpads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1ph or3 ph line to line and line to neutral voltage,Current(1phor3ph),kVA(3ph and total), Frequency, Provide Engine Data, Starting batteryvoltageEngine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions,Voltage,frequency selection,Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleepmode.Acoustic enclosure:The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/CPCBnormsof75dBA@1mtr at75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have ptimum serviceability,Air inlet louvers speciallydesigned to operate at rated load madeonspecial purposeCNCmachinesfor consistencyin quality and workmanshipPowder coated for long lasting servicelife and superiorfinishWithUVresistant powdercoatingcan withstandextremeenvironment,Useof specialhardware for longer life,Insulationmaterialmeets exactingIS183 specifications for better sound attenuationFlush styling no projectionsFluid drains for lubeoiland fuelFuel fillin pointnsidethe enclosure.12 KVA/10 kw with all leads&lifts completeasperspecificationas

1

946003

946003.8

... More
code233 - Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.82.5 KVA to 125 KVA. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

115007

115007.55

... More
code234 - Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering,adequate 2280 LPM and 70m head at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories,neoprine gaskets (16 kg/sq.cm) Control panel is excluded.Required GA drawing for the pump/ foundation shall be submitted by the contractor. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

299250

299250

... More
code235 - Supply, erection, testing and commissioning of Fire Fighting panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted, degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners. The switchboards are to be tested as per IS 8623-1977 specifications. Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height Incoming feeder for 250A TPN MCCB with 250 Amps. TPN Al. Bus bars with color coded heat shrinkable PVC sleeves, RYB indicating lamps with individual MCB control. Suitable Mulit Fuction meter with CTs OUTGOING Feeder for 1 No. of main pumps :- 1 Nos.160A TP MCCB with 60 HP Star delta starter with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons. 1 No. Auto manual selector switch.: a) 20Amps DP MCB - 4 Nos. b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off selector switch - 2 Nos. c) 1 set of indicating lamps for the following : 1. phase indication 2. battery charger on 3. over load relay 4. DC supply on 5. control switch on 6. Engine fails to start 7. Pump on 8. Low oil pressure 9. High water temperature 10. Auto manual selector switch d) 1 sets of push button stations for the following : 1. Engine Start 2. Engine Stop 3. Engine - hooter ACK 4. Engine - fault reset e) Selector switches (Engine control, mode selector)-1 No. f) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set. g) Hooter for audio alarm (Industrial type) - 1 No with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

291900

291900

... More
code236 - Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 3.5C x 120 sq.mm for main pumps (Al) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

8

479

3837.12

... More
code237 - Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 3.5C x 95 sq.mm for main pumps (Al) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

8

391

3134.96

... More
code238 - Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 2 C x 2.5 Sqmm.for Instrumentation (Cu) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

5

65

326.35

... More
code239 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 200mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

5

5145

25725

... More
code240 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 150mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

5

4515

22575

... More
code241 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. 150mm nominal dia

5

4095

20475

... More
code242 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. 25mm nominal dia

5

735

3675

... More
code243 - Supplying installing, testing and commissioning of PN16 CI "Non Return Valve " confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading andunloading transportation etc complete. etc., complete as per specificaitonwith all lead and lift, loading unloading, labour, hire charges of machineriesand all such incidental charges necessary for successful completion of workand as per directions of the Engineer-in-charge of the work 150 mm nominal dia

1

12075

12075

... More
code244 - Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc.,complete etc.,complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary forsuccessful completion of work and as per directions of the Engineer-in-chargeof the work 150mm nominal dia

1

13125

13125

... More
code245 - supply and installing testing and commissioning of CI " Y " stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such in cidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 200mm dia.

1

25725

25725

... More
code246 - Supplying, installing , testing and commissioning approved make CI Gate valves as per IS: 780 / 14846 with flanges, bolts, nuts, washers, gaskets etc. complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 200mm nominal dia.

1

41672

41672.4

... More
code247 - Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 15mm dia.

1

997

997.5

... More
code248 - Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 25 mm dia

1

1260

1260

... More
code249 - Pressure Switch including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. etc., complete as per specificaiton with all lead and lift, loadi g unloading, labour, hire charges of machineries and all such incidental charges necessary for successful comp

1

2047

2047.5

... More
code250 - Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work

1

3045

3045

... More
code251 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work. 150mm nominal dia

10

4095

40950

... More
code252 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 100mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

5

2992

14962.5

... More
code253 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 25mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

5

735

3675

... More
code254 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m,80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications 100mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

5

3255

16275

... More
code255 - Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m,32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m,80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications 80mm nominal dia with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

5

2415

12075

... More
code256 - Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc.,complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 150mm nominal dia (For Risers) with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

13125

13125

... More
code257 - Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

11025

44100

... More
code258 - Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

5250

21000

... More
code259 - Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

4725

18900

... More
code260 - Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 DGREE swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

5460

21840

... More
code261 - Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

6300

25200

... More
code262 - Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodate 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

4

6825

27300

... More
code263 - Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

34650

34650

... More
code264 - Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour,usage charges of machinery with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

1575

1575

... More
code265 - Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 25mm dia. with all leads & lifts complete as per specification and as directed by the engineer incharge of the work.

1

1260

1260

... More
code266 - Providing SUPPLYING. INSTALLATION, TESTING and COMMISSIONING of Goods Lifts for Ground plus 3 Floor Capacity : 1000 Kgs, Platform size : 1600 L X 1600 W mm X 2100 H, Maximum height : 4000 mm, Min Height : 300 mm, Lift Height : 3700 mm, No of Mast Pairs : 1, No of cylinders : 1 cabin platform made of M.S. checkered plate 5mm thick with one coat of primer & two coats of enamel paint the cost includes of necessary M.S Frame work & with all accessories for the smooth operation of goods lift including all necessary fittings, equipment’s , cost of materials, Formwork, labour, usage charges of machinery with all leads & lifts complete as per specification & as directed by the Engineer in charge of the work.

1

1150000

1150000

... More
code267 - Supply. installation, testing and commissioning of plant and equipment for cold stores as per the specifications. Product to be stored multi commodities(1)Cold rooms shall be constructed using 80mm thick Prefabricated Rigid Polyurethane Foam (RPUF) insulated panels laminated with Pre-Painted Galvanised Steel (PPGS) lamination on inside and outside inside with serrations for the walls & roofing. The wall to wall & roofing joinery shall be with Tongue and Groove arrangement. The wall to roof joinery shall be held using flashing from inside & outside. All the resulting panel joinery shall be applied with silicon sealant.2)The floor insulation shall be constructed using 60mm thick RPUF insulated panels laminated with 250 micron thick polythene sheet lamination acting as vapor barrier on both sides.3 the Roof insulation shall be constructed using 80mm thick Roof Panels shall be pre- fabricated roofing panels made of Rigid Polyurethane Heat Terminating Roof Foam (RPUF)sandwiched between layers of waterproof and non-corrosive material 4 The doors (2Nos) shall be Manual Sliding type of size 1.80mx2.4m-80mm thick in the corridor in each flloor and Hinged type doors (20Nos) of size 1.2mx2.1m-80mm thick in the rooms. Door shall be provided with internal safety release mechanism and hooter switch.(5)The refrigeration system shall be Freon based split type of 20KWcapacity-No.of units-20Nos(2 Nos in each room) with Air Cooled Condensing Units located outside the room and the Evaporator Units located inside the room. The condensing unit shall house suitable capacity hermetic compressor for the rooms, condenser coil and fans. Weather proof electrical starter panel for the full unit shall be mounted inside the condensing unit. (6) The evaporator shall be constructed using GI casing & condenser cabin shall be constructed using GI casing. All the refrigerant tubes shall be with copper construction & Al fins. The evaporator shall be provided with suitable fin spacing to allow sufficient frost build up to enable longer operation hrs between defrost. Defrost shall be automatic. The drain tray has been provided with additional heaters to avoid ice buildup.Capacity of Evaporator unit 20kWNo.of units-20Nos(2Nos for each room2 x 10 rooms) (7)The interconnecting copper piping shall be generously designed to minimize the pressure drop in the system.(8)Type of light fitting High bay LED vapor proof fittings suitable for cold rooms.(9)Ambient Temperature [in degree C] 25Deg C-40 DegC(10) Designed Room Temperature (plus)2 to(plus) 8 Degc(11) Designed Room Humidity [% RH] In the range 70 to 85% with plus-minus 5% Variation (12)Type of refrigeration system Split Type-Individual Refrigeration system (13) Type of Refrigerant R404a (14) Type of Compressor Hermetic(15)Type of Condenser Air-Cooled (16) Temperature / humidity indicator-cum-controller Micro-Processor based controller shall be provided (17)Interconnecting piping and wiring between the Condenser and Evaporator units as required(18)No Cold Rooms in each Floor 10 Nos (Ground Floor plus 1 Floor) ( size of each room as shown in the Drawings)(19)The compressor on/off based on the load shall be controlled by a micro processor based digital temperature controller which shall also control the defrost cycle, on/off of fans, fault indications etc, thereby controlling the entire refrigeration system.Complete with all leads & lifts complete as per specification and as direted by the Engineer incharge of the work.For detailed technical specification refer annexure in KW4 bid document

1

25983799

25983799



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.