Urban Development Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Urban Development Department - JUIDCO Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date10 Oct 2024
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.5 - 2.5 m

317.3

-

-

... More
2.5 - 3.5 m

298.65

-

-

... More
3.5 - 4.5 m

280.55

-

-

... More
4.5 - 5.5 M

263.02

-

-

... More
5.5 - 6.5 M

246.06

-

-

... More
6.5 - 7.5 M

229.66

-

-

... More
7.5 - 8.5 M

213.83

-

-

... More
8.5 - 9.5 M

198.56

-

-

... More
Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.

-

-

-

... More
0 to 1.5 M

121.5

-

-

... More
Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.

-

-

-

... More
1.5 M to 2.0 M

32

-

-

... More
Earthwork in excavation (As per I.S 3114 /1965 for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer-in-Charge

-

-

-

... More
Total Excavation in all type of Soil strata

-

-

-

... More
For Classification of Soil Item -A

105486

-

-

... More
For Classification of Soil Item -B

73840.55

-

-

... More
E/W in excavation of cut-off trenches by the hydraulic excavator as per designed section in soft rock (Where blasting is not needed) (vide type of soil item -C) with disposal of soil beyond 1/2 km from centre of trench but upto 1 km with all lifts by tipper including construction and maintenanceof haul road all complete as per specification & direction of E/I .

-

-

-

... More
Excavation in Hard Strata

31645.95

-

-

... More
Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts, evelling , ramming the foundation trenches, removing roots of trees , surbs all complete as per approved design, building specification and direction of E/I.

1108.34

-

-

... More
E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item - A) and disposal of excavated earth obtained to a distance upto 50 M including all lift leveling, ramming the foundation trenches removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.

17.25

-

-

... More
Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 m and lift of 1.5 m all complete as per building specification and direction of E/I

60.83

-

-

... More
Earthwork in back filling the trenches after laying different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and design of Engineer -in- charge (for classification of soil item A & B )

180802.6

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.

14783.29

-

-

... More
Dewatering

-

-

-

... More
Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete.

37050

-

-

... More
RCC/PCC

-

-

-

... More
Plain / Renforced Cement Concrete in open foundation complete as per drawing and technical specifications. Footing - PCC Grade M20

39.58

-

-

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of store chips 20 mm-6 mm size graded and clean coarsed sand of FM 2.5 to 3.0 including screeing shuttering mixing cement concrete in mixer and placing in position vibrating striking curing taxes and royalty all complete as per building specification and directio of E/I

4501

-

-

... More
REINFORCEMENT

-

-

-

... More
Providing TOR steel reinforcement of 10 mm, 12 mm & 16 mm dia bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/I b) 12 mm (TMT coil Fe500)(only valid for TATA

139.02

-

-

... More
Providing Tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carrriage of MS bars to work site. Including cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 10 mm (TMTcoil Fe 500)

65.66

-

-

... More
Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of M.S. Rods to work site, cutting, bending, and binding with annealed wire with cost of wire removal of rust, placing the rods in position all complete as per building specification and direction of E/I.

11.24

-

-

... More
Road Cutting and Road Restoring

-

-

-

... More
Supplying tools and cutting road as well restoring the same as per specification and direction of E/I.

-

-

-

... More
Pucca Road (Except black top only taken out material to be used) for cutting road as per requirement.

78631

-

-

... More
Water bound macadam road (taken out material will be used) for cutting road as per requirement and making good the same.

40678

-

-

... More
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15 meter lead and disposal of un-serviceable materials with all leads all complete as per direction of E/I

4501

-

-

... More
Plaster

-

-

-

... More
Providing 12 mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.

4310.59

-

-

... More
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding, taxes & royalty all complete as per building specification & direction of E/I.

366.31

-

-

... More
Providing 1.5 mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I

50.7

-

-

... More
Brickwork

-

-

-

... More
Providing designation 75A brickwork in C.M. (1:6) in superstructure with approved quality of clear coarse sand of FM 2 to 2.5 including providing 10 mm thick mortar joints cost of screening, materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

44.33

-

-

... More
Providing designation 75A one brick flat soling joint filled with local sand including cost of watering taxes royalty all complete as per.building specification and direction of E/I

546.45

-

-

... More
Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening, materials, scaffolding, raking out joints to 15 mm depth curing, taxes & royalty all complete as per building specification & direction of E/I.

462.57

-

-

... More
Intake

-

-

-

... More
Providing, constructing coffer dam in river basin / dam storages as per type design including excavation, filling the middle portion with B.C. soil (in gunny bags if required). Providing impervious / semipervious materials on both sides of B.C. soil (in gunny bags if required) including ramming, compacting to the satisfaction of Engineer-in-charge till the completion of work including dismantling coffer dam after completion of works and disposing off the material as directed by the Engineer-in-charge. Note : Pay line maximum. Top width payable shall be 2 Mtr. and maximum payable side slopes shall be 1.5 horizontal to 1 vertical, if the constructed top width of the side slopes are less, then the measurements at actual are payable. Extra top width or flat slopes are not payable. Contractor is free to use ballies, plastic sheets, piles, pipes, CGI sheets for supporting hearting materials instead of impervious/ semi-pervious hearting materials for which no extra payments shall be payable.30% payment shall be withheld for dismantling of coffer dam.

3234.08

-

-

... More
V Wire Seive Bend box for intake cum infiltration well 'Design and supply of stainless steel all weldedwedge wire seive bend box screen for infiltration well. seive 750mm x750mm ,slot 01-50 mm,MOC-SS 304,Side Fram SS 304

10

-

-

... More
Rose Piece for intake wells Material of rose piece screen, flange should be SS 304 and suitable to Slot of the rose piece will be 2 mm to 4 mm as per site requriement the slot shape should be widening in inwardly to reduce the water velocity.Screens will be as per IS 8110as per latest rivision ,SCREEN DIA X LENGTH,850 MM X 500 MM

4

-

-

... More
Plain / Renforced Cement Concrete in well foundation complete as per drawing and technical specifications. Footing- RCC M30

95.57

-

-

... More
Plain / Renforced Cement Concrete in well foundation complete as per drawing and technical specifications. Steining Wall - RCC M30

1415.46

-

-

... More
Plain / Renforced Cement Concrete in well foundation complete as per drawing and technical specifications. Top Slab - RCC M30

160.45

-

-

... More
Supplying equipment and labour for back filling the excavated earth around steining well all complete as per specification and direction of E/I.

135.6

-

-

... More
Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding, anchoring and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.

42.7

-

-

... More
Inside painting Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floor and taxes all complete as per building specifciaction and direction of E/I.

75.4

-

-

... More
Outside Snowcem Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including washing cleaning and preparing the walls, scaffolding, curing and taxes all complete as per building specification and direction of E/I

87.96

-

-

... More
Ceiling whitewash Whitewasing three coats over new surface with approved quality of lime incuding cost of cleaning surface throughlly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I.

160.61

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters.

9

-

-

... More
Window Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standards rolled 'z' and mullian steel sections and size a per IS 1038 Joints met and welded with 100*16*3 mm MS lugs fixed in cement concrete (1:2:4) blocks 15*10*10 cm, size including cost of oxidized iron fittings with hinges, handle per steps, catch springs, 3 mm thick plain glass pens with aluminium beads and inner frame fixed with lugs with 20 mm long 6 3mm GI counter sunk machine screw and nuts and applying a coat of red lead paint carriage to ork site, hoisting and placing in position in all stories and taxes all complete as per building specification and diection of E/I

4.86

-

-

... More
Concretina Door Supplying, fitting and fixing Collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm. at 100 mm. Centres and braced with MS flat diagonals 20x 3 mm with top and bottom rails of T. iron 40 x40x6mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage, hoisting and taxes all complete as per building specifications and directions E/I.

9

-

-

... More
15" (380 mm) metal exaust fan

8

-

-

... More
Five course water proofing on roof a) Surface Preparation b) 1st Coat c) 2nd Coat d) Protection of treated surface with PCC e) Groove of PCC surface

160.52

-

-

... More
Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm, size graded Stone chips finished with flooring coat of neat cement in panels

160.52

-

-

... More
Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates,gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). 10% Extra for making holes 200 mm Dia 9.5 mm Thickness

42.6

-

-

... More
FABRICATION OF M.S. PIPES & SPECIALS Blast cleaning the surface of the old or new pipeline internally to remove all rust etc. complete, including providing copper slag/garnet, machinery, labour, cutting of pipes at required places and rewelding the same etc, complete as directed by Engineer-in-charge MS Specials

127.8

-

-

... More
Approach Bridge

-

-

-

... More
Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 m and lift of 1.5 M all complete as building specification and direction of E/I.

51.17

-

-

... More
Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. For Foundation - RCC-300

38.05

-

-

... More
Providing and casting in situ Cement Concrete of trap/ granite / quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerincharge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. For all types of columns - RCC-300

3.4

-

-

... More
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. ) Beams - RCC-300

79.35

-

-

... More
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. ) Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase - RCC-300

15.75

-

-

... More
Providing, fabricating and erecting hand railing for walkway, top dome slab, balcony, staircase and landing consist of two rows ( one at top and other at middle level) of 20 mm GI pipe class-B and 900 mm high vertical angle 65X65X6 mm at spacing 1.50 m c/c including welding, threading, applying a priming coat of approved steel primer and embedding in cement concrete floor complete in all respect as per specification and the direction of the Engineer

70

-

-

... More
RWRM , CWRM & DISTRIBUTION

-

-

-

... More
Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-9 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining on inside surface with outside zinc and bituminous coating.

-

-

-

... More
200 mm dia

1621

-

-

... More
250 mm Dia

2368

-

-

... More
300 mm Dia

3758

-

-

... More
350 mm Dia

8779

-

-

... More
400 mm Dia

399

-

-

... More
450 mm Dia

20900

-

-

... More
600 mm Dia

34600

-

-

... More
Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-7 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating (including cost of one no. gasket for each pipe). Rate are exfactory excluding transportation, taxes & duties contractor profit and over head charges etc.

-

-

-

... More
100 mm dia

99220

-

-

... More
150 mm dia

21374

-

-

... More
200 mm dia

15364

-

-

... More
250 mm dia

4642

-

-

... More
300 mm dia

2798

-

-

... More
350 mm dia

6823

-

-

... More
400 mm dia

3804

-

-

... More
Providing, supplying ISI standard D.I. specials & fitting with sealing rubber gasket of S.B.R. complete with cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for D.I. pipes including all taxes etc. complete as per IS 9523 class K-12 9 ex - factory). Socketed

-

-

-

... More
100 - 300 mm dia

13082.83

-

-

... More
300- 450 mm dia

70342.28

-

-

... More
350 - 450 mm dia

204509.51

-

-

... More
500-600 mm dia

161557.71

-

-

... More
Supplying labours, tools, tackles, lubricant etc. for laying and jointing DI/C.I.S/S Tyton pipes (class LA) trenches supplying rubber gasket (Rubber gaskets confirming to I.S.S.-5382-1969) and taking gasket joints including providing night guard, barrier and red light to safe guard against accident, all complete , laying of pipes is to be done as per (I.S.S. 3114 -1985) as per design, specification and direction of E/I.

-

-

-

... More
100 mm dia

99220

-

-

... More
150 mm dia

21374

-

-

... More
200 mm dia

16985

-

-

... More
250 mm Dia

7010

-

-

... More
300 mm Dia

6556

-

-

... More
350 mm dia

15602

-

-

... More
400 mm Dia

4203

-

-

... More
450 mm Dia

20900

-

-

... More
600 mm Dia

34600

-

-

... More
Supplying labours, tool and tackles for testing of laid CI or UPVC or HDPE or AC or DI pressure pipe all complete as per specification direction E/I

-

-

-

... More
100 mm dia

98446

-

-

... More
150 mm dia

21374

-

-

... More
200 mm dia

16777

-

-

... More
250 mm Dia

7010

-

-

... More
300 mm Dia

6556

-

-

... More
350 mm dia

15254

-

-

... More
400 mm Dia

4203

-

-

... More
450 mm Dia

20900

-

-

... More
600 mm Dia

34600

-

-

... More
Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.

-

-

-

... More
100 mm dia

1985

-

-

... More
150 mm dia

428

-

-

... More
200 mm dia

340

-

-

... More
250 mm Dia

142

-

-

... More
300 mm Dia

132

-

-

... More
350 mm dia

313

-

-

... More
400 mm Dia

86

-

-

... More
450 mm Dia

418

-

-

... More
600 mm Dia

692

-

-

... More
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking levied by GOI & GOM in all respect etc. PN-1.6 Without by pass complete.

-

-

-

... More
Sluice Valve

-

-

-

... More
350 mm dia

10

-

-

... More
600 mm dia

2

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.

-

-

-

... More
Sluice Valve

-

-

-

... More
450 mm Dia

10

-

-

... More
300 mm Dia

2

-

-

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI&GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part (1984) Without by pass arrangement PN-1.6

-

-

-

... More
Non Return Valve

-

-

-

... More
350 mm dia

4

-

-

... More
400 mm Dia

2

-

-

... More
450 mm Dia

2

-

-

... More
600 mm dia

10

-

-

... More
Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete. Kinetic Air Valve Flanged Type - PN -1.6

-

-

-

... More
80 mm Dia

19

-

-

... More
100 mm Dia

44

-

-

... More
150 mm dia

131

-

-

... More
Lowering, laying and fixing in properalignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves) Air Valve Double Ball (PN-1 and PN - 1.6)

-

-

-

... More
80 mm Dia

36

-

-

... More
100 mm Dia

74

-

-

... More
150 mm dia

76

-

-

... More
Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete. Without bypass arrangement - PN - 1

-

-

-

... More
Scour valve

-

-

-

... More
80 mm Dia

67

-

-

... More
100 mm Dia

19

-

-

... More
Providing, double flanged short bodyProviding, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation structural steel support. Butter fly valve PN-1.6

-

-

-

... More
200 mm

1

-

-

... More
250 mm

3

-

-

... More
300 mm

3

-

-

... More
350 mm

2

-

-

... More
400 mm

5

-

-

... More
450 mm

2

-

-

... More
Providing double flange sluice valve (50 mm to 1100 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete. Without bypass arrangement - P.N - 1.6

-

-

-

... More
100 mm Dia

103

-

-

... More
150 mm Dia

45

-

-

... More
200 mm dia

26

-

-

... More
250 mm Dia

17

-

-

... More
300 mm Dia

7

-

-

... More
350 mm Dia

6

-

-

... More
400 mm Dia

3

-

-

... More
450 mm Dia

8

-

-

... More
Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete. Kinetic Air Valve Flanged Type - PN -1.6

-

-

-

... More
80 mm Dia

17

-

-

... More
100 mm Dia

41

-

-

... More
150 mm Dia

4

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.

-

-

-

... More
80 mm Dia

67

-

-

... More
100 mm Dia

119

-

-

... More
150 mm dia

41

-

-

... More
200 mm dia

27

-

-

... More
250 mm Dia

20

-

-

... More
300 mm Dia

10

-

-

... More
350 mm Dia

8

-

-

... More
400 mm Dia

13

-

-

... More
450 mm Dia

6

-

-

... More
Providing, lowering, laying, aligning, fixing in position in pipe line Zero Velocity Valves of 600 mm dia as per IS:14845 of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer etc, complete in all respect.

3

-

-

... More
Providing, double flanged short bodyProviding, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation structural steel support.

-

-

-

... More
Butter fly valve PN-1.6 ( 600 mm dia )

4

-

-

... More
Providing, lowering, laying, aligning, fixing in position jointing in pipeline following dia D/F DI Plunger valve (Flow Control Valve) PN 1.6 class with electrical actuator suitable for SCADA compatibility complete (including jointing & jointing material) including all material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer. High Altitude Values

-

-

-

... More
250 mm Dia

1

-

-

... More
300 mm Dia

1

-

-

... More
Lowering, laying and fixing in properalignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves) Kinetic Air Valve (PN-1 and PN - 1.6)

-

-

-

... More
100 mm Dia

11

-

-

... More
150 mm Dia

59

-

-

... More
Pressure Reducing Valve - Designing, Supplying, Installing, Commissioning & testing ofPilot operated hydraulically controlled Pressure reducing Valve for ESR/MBR outlet or distribution with pressure controlling / limiting application which maintains a constant downstream pressure regardless of fluctuations in inlet pressure or flow with fixed set points inclusive of all the accesories like pressure gauge etc. complete as per given specifications

-

-

-

... More
100 mm

1

-

-

... More
150 mm

1

-

-

... More
200 mm

1

-

-

... More
250 mm

1

-

-

... More
300 mm

1

-

-

... More
Providing and supplying C.I. D/F angle type spring loaded pressure relief valves of approved make and quality including inspection charges, transportation to departmental stores excluding GST levied by GOI & GOM in all respect etc.complete. 250 mm

1

-

-

... More
Lowering, laying and fixing in proper alignment and position all types of C.I. D/F angle type spring loaded pressure relief valves including cost of all material, labour, cost of conveyance from stores to site of work and giving satisfactory hydraulic testing, etc. complete.(For all class of valves.)

1

-

-

... More
Flow Meter for Pipeline & Scada

-

-

-

... More
Full-Bore Electromagnetic Flow Meter: Supply, install and commission Electromagnetic Flow Meter (EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/-0.5% of measured value & protection as per given specifications for size 100 mm-1000mm including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications.

-

-

-

... More
100 mm Nominal Dia Flowmeter

17

-

-

... More
200 mm Nominal Dia Flowmeter

14

-

-

... More
250 mm Nominal Dia Flowmeter

13

-

-

... More
300 mm Nominal Dia Flowmeter

2

-

-

... More
350 mm Nominal Dia Flowmeter

1

-

-

... More
400 mm Nominal Dia Flowmeter

6

-

-

... More
450 mm Nominal Dia Flowmeter

2

-

-

... More
500 mm Nominal Dia Flowmeter

2

-

-

... More
600 mm Nominal Dia Flowmeter

2

-

-

... More
INTERMEDIATE BOOSTING PUMPING SYSTEM & Staff Quarter

-

-

-

... More
Plain Concrete Cement (P.C.C) Providing and laying in Position cement concrete of specific grades excluding the cost of centering and shuttering -All works up to plinth level : 1:2:4 (1 Cement : 2 Coarse sand (zone-iii): 4graded stone aggregate 40 mm nominal size) Foundation

10.06

-

-

... More
Reinforcement Concrete Cement (M-25 R.C.C) Providing and laying in position machine batched and machine mixed design grade cement concrete for reinforced cement concrete work, using cement content as approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing, and reinforcement, including admixture in recommended proportions as per IS: 9103 to accelerate retard setting of concrete, improve workability without imparing retard setting of concrete, improve workability without imparing strength durability as per direction of Engineer-in -charge. All the works upto plinth

55.5

-

-

... More
Providing P.C.C. M -100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade- III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer & placing in position, vibrating, striking, curing, taxes & royalty all complete as per building specification & direction of Engineer-in-charge.

0.44

-

-

... More
Reinforcement Concrete Cement (M-25 R.C.C) Providing and laying in position machine batched and machine mixed design grade cement concrete for reinforced cement concrete work, using cement content as approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing, and reinforcement, including admixture in recommended proportions as per IS: 9103 to accelerate retard setting of concrete, improve workability without imparing retard setting of concrete, improve workability without imparing strength durability as per direction of Engineer-in -charge. All the works above plinth level upto floor level

66.62

-

-

... More
Providing R.C.C.M-200 with nominal mix of (1:1.5:3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking. curing (but excluding the cost of reinforcement, taxes and royalty all complete, as per building specification and direction E/I.

0.05

-

-

... More
Centering and Shuttering including strutting, propping etc. and removal of form for Foundation, footings, bases of column for mass concrete

966.5

-

-

... More
Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I.

361.9

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales, smokes, grease and sand preparing, including cost of scaffolding and taxes all complete as per building specification and direction of E/I.

24.2

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.

97.2

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm thick bed by dry brick ballast 40mm nominal size, well rammend and consolidated and grouted with fine sand, including necessary excavation, levelling, dressing & finishing the top smooth.

320

-

-

... More
Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19mm. thick base of lime morter (1:1:1) (lime putty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specificationand direction of E/I. (iv) 600 x 600 mm size

91.31

-

-

... More
Providing and laying 25mm. thick kotah stone tiles in risers of steps, skirting and pillars of approves size, texture and colour laid over 12mm. thick cement mortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolilthic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specificationand direction of E/I.

93

-

-

... More
Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding curing and taxes all complete as per building specification and direction of E/I

253.75

-

-

... More
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat or 16 mm square bars fitted on 25x25x6 mm M.S angle frame as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. Window Grill

270

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

382.67

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

382.67

-

-

... More
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.

382.67

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge

-

-

-

... More
Window

-

-

-

... More
For fixed portion - Powder coated aluminium (minimum thickness of powdercoating 50 micron)

35.64

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required - Powder coated aluminium (minimum thickness of powdercoating 50 micron)

45

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . : With float glass panes of 4.0 mm thickness Window

13.68

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width

14.4

-

-

... More
Providing and fixing fan hook of 16 mm dia MS bar 1meter long bent to requried size and shape, placed in position and fixed in RCC slab/beam at the time of casting all complete as per building specification and direction of E/I

10

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters 80x1.25mm M.S. laths with 1.25 mm thick top cover

10.5

-

-

... More
Providing 12 mm thick water proof cement plaster (1:3) in CM 1:3 with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound all complete as per building specification & direction of EЛ.

26.7

-

-

... More
Providing, hoisting and fixing in position C.I. manhole, frame and cover of best quality and of required size and shape with locking arrangements including applying 2 coats of anti-corrosive paint, etc. complete.

2

-

-

... More
Supplying materials and labours for constructing inspection chamber of designation class 75-8 bricks size 750 mm deep, 600 mm x 450 mm internal dimension having 250 mm wall thickness in cement mortar (1.6) including 12 mm cement plaster (1:4) with punning on side and cement plaster (16) with 600 mm x 475 mm G.I. cover with frame (weight not less than 36Kg) along with earth work in excavation and 80mm thick PCC-(1:3:6) in foundation and refilling all complete as per specification and direction of E/I

2

-

-

... More
Sanitary Installation

-

-

-

... More
Supplying, fitting and fixing vitreous white glazed earthen ware I WC of Perry Hindustan or any other ISS approved make with 100mm HC.I. 'P' TRAP (15) Liters C.I. pull and let go flushing C.I.stern of names or other ISS equivalent make, complete with all fittings, C.. or C.C. brackets 32 MM alkathenae PVC telescopic flush, pipe about 2m long with one brass coupling and clamps G.I. Chain and pull including supplying and fixing a pair or vitreous white glazed earth ware footrest to be fixed in floor 50Gms., 15mm PVC Connection pipe 450 mm Long and the exposed pipe and C.I.stem with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of EA. 580 mm long with 12.5 lit low level PVC cistern

2

-

-

... More
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of Perry of Hindustan or any other iSS approved make supported on painted C.I. or RS Brackets 32mm CI brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc all complete as per specification and direction of EЛ.

2

-

-

... More
Providing and fixing G.I inlet connection for flush pipe connecting with WC pan

2

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipe, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge 20 mm nominal dia pipes

100

-

-

... More
Supplying and fixing of approved make (Conforming to IS :- 1879) all complete as per specification and direction of E/I

-

-

-

-

-

-

... More
(a)15mm dia

20

-

-

... More
TEE(PLAIN)

-

-

-

... More
(a)15mm dia

20

-

-

... More
REDUCING SOCKET

-

-

-

... More
(a)15mm dia

10

-

-

... More
Nipple

-

-

-

... More
(a)15mm dia

40

-

-

... More
UNION SOCKET

-

-

-

... More
(a)15mm dia

20

-

-

... More
SOCKET

-

-

-

... More
(a)15mm dia

20

-

-

-

-

-

... More
(a)15mm dia

20

-

-

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms

4

-

-

... More
Providing and fixing mirror of superior glass (of approved quality)and requried shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm

2

-

-

... More
Providing and fixing brass ferrule with C.I mouth including boaring and tapping the main 15 mm nominal bore

10

-

-

... More
Providing and fixing C.P.brass shower rose with 15 or 20mm inlet 100 mm diameter

4

-

-

... More
Providing and placing on terrace (at all floor levels) polyctylene water storage tank IS: 12701 marked wit cover and Suitable Locking arrangement and Making neccessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank.

1000

-

-

... More
Electrification for Staff Quarter

-

-

-

... More
Wiring for light/ceiling fan/exhaust fan/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI Box etc as requried

-

-

-

... More
Group A

20

-

-

... More
Group B

20

-

-

... More
Group C

20

-

-

... More
S/F PVC Conduit:- Supplying anf fixing of following sizes of PVC conduit along with assessories in surface /recess including cutting thw wall and making good the same in case of recessed conduit as requried . 20 mm

120

-

-

... More
S/F PVC/G.I boxes:- Supplying anf fixing of following sizes of PVC/G.I box on surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc.as requried. 72mm x146mm x48mm deep/(4" x 7")

20

-

-

... More
S/F Piano type switch socket:- Supplying anf fixing of following panio type switch/socket on the existing switch box /cover including connection etc.as requried. 5/6 amp,two way switch

20

-

-

... More
S/F Modular type electronic fan regulator:- Supplying anf fixing stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc.as requried.

8

-

-

... More
S/F Power Plug point with paino type accessories:- Supplying anf fixing suitable size GI/PVC box of 121mm x 173mm x48 mm/(6" x 8") (nominal size) on surfaceor in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 amp piano type switch connection painting etc.as requried.

25

-

-

... More
S/F celing rose:- Supplying anf fixing 2 pin 5 amp .Celing rose on existing junction box/ wooen block including connection etc. as requried.

25

-

-

... More
Erection on incandescent light fitting:- Erection of wall bracket/cell fitting of all sizes and shapes containing upto two GLS lamp per fitting completewith all accessories including connection etc. as requried.

15

-

-

... More
S/F HRC fuse type TP & N switch disconnector:- Providing and fixing following TP & N diconnetors fuse switch unit in the existing metal board with ISI marked HRC fuses including drilling holes in metal board, making connection etc. as requried. 63 amp TP & N, HRC

10

-

-

... More
S/F Pannel mounted change over:- Providing switches in existing cubical pannel board ,,making connetions earthing the body etc. as requried. 125 amp ,4 pole

6

-

-

... More
S/F SP MCB DB:- Supplying and fixing following way, single pole and neutral sheet steel, copper bus bar, neutral bus bar, earth bar ,din bar, interconnections, powder painted including earthing etc. as requried. (But without MCB/RCCB/Isolator) 12 way Double Door

10

-

-

... More
Earthing with G.I earth plate 600mm x 600mm x 6mm thick including accessories and providing masonary enclouser with cover plate having looking arrangement and watering pipe etc. (with charcoal or coke and salt) as requried.

2

-

-

... More
Fixing lightining conductor final:- Fixing of lightining conductor final (single prong )with base plate including holes etc. complete as requried.

2

-

-

... More
Erection of CC pole upto 1.1 m in B.B Erection of RCC /PCC pole of following length in brick ballast and ramming the foundation finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling rtc as requried. Above 4.5meters and upto 6.5 meters

1

-

-

... More
Supply Installation,testing and commissioning of following size celling fan 3 Blades confirming to IS 374:2019 including wiring the down rod of standard length (upto 30 cm )with 1.5 sq.mm FR PVC insulated, copper wire suitable for 230V 50Hz single phase supply etc complete as requried. 1200mm (48") Celing Fan

8

-

-

... More
S.ITC of following rating surface mounted LED tube light fitting suitable for 230v 50Hz single phase supply etc. complete as requried 10/12W LED Tube light

15

-

-

... More
Celling fan 48" (1200mm)

8

-

-

... More
RCC GSR AND SUMP in IBPS

-

-

-

... More
Designing (aesthetically), and constructing RCC ground service reservoirs RCC sumps in M-300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye-pass arrangement consisting of C.I./ M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications incuding Landscaping, Gardening & Plantation etc

-

-

-

... More
Anti -termite treatment shall be given for under-ground portion of the structure.

-

-

-

-

-

-

... More
(1) The design shall be in accordance with various relevant I.S. specification (IS 456 / 2000, IS 875-1987, IS 3370-1965 or revised.)

-

-

-

... More
2. Only M.S. bars grade I conforming to I.S. 432 part-l or high yield strength deformed bars conforming to I.S. 1786 or I.S.1139 shall be used. Grade- II M.S. bars shall not be used.

-

-

-

... More
3. Entire structure shall be in M-300 only.

-

-

-

... More
4. The scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall cost of pipes valves specials is not included in the rate but dabour cost for laying and jointing is included

-

-

-

... More
5. The G.S.R./Sump above 15 lakh "tres capacity shall be in two compartment.

-

-

-

... More
6.The Job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineer-in-charge. If up lifts considered in design, then these rates shall be increased by 7.5%

-

-

-

... More
7.G.S.R. outlets shall be with outh of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.

-

-

-

... More
8. For pipe diameters upto 300mm only Clpipes and Cl specials shall be used. For pipe diameters above 300mm, M.S. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside.

-

-

-

... More
9.Cost of pump house is not included in these rates.

-

-

-

... More
10. Above rates are applicable for Seismic Zones 2, 3 and 4.

-

-

-

... More
11. 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.

-

-

-

... More
1. 660000 liters ( 660 KL) - For IBPS

1

-

-

... More
2. 265000 liters (265 KL) - For IPS

1

-

-

... More
Water Treatment Plant - 21.12 MLD

-

-

-

... More
Designing (aesthetically ), providing constructing and commissioning Conventional Water Treatment Plant consisting of all Civil, Mechanical and Electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing antitermite treatment to entire structure below ground level, mechanical and electrical components of various sub-works as given below, including necessary hydraulic testing, structural testing, equipment testing and trial run for a period of 3 months, etc. complete as directed by Engineer-in-charge (turn-key job).

-

-

-

... More
Aeration Fountain- Plan are a not less than 0.625 square metre per MLD

-

-

-

... More
Ventury Flume - With necessary devices, consisting of simple mechanical indicator. (Pedestal type gauge)

-

-

-

... More
Flash Mixer-Rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec -1, vane mixer type conforming to I.S. 7090 of 1985.

-

-

-

... More
Flocculator – Conforming to I.S.7208-1974 (Type-C) with detention period of 30 minutes.

-

-

-

... More
Clarifier - Horizontal flow circular tank, detention period 2-5 hours, overflow rate 30 cubic metre per square metre per day (to be specified), Weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to I.S. No. 10313-1982. with necessary inlet arrangements.

-

-

-

... More
Rapid Sand Filter sand Filter House-Filter designed for filteration rate of 5,000 litres per square metre per hour, minimum 2 beds for plant upto 10 MLD, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width with constant rate filtration or declining rate filtration.

-

-

-

... More
FilterSand-Effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75M, free board 50cm, gravel 0.45M in depth, sand and gravel conforming to I.S. 8491 (i)-77, back wash by air wash, standard appurtenances (to be specified), rate of flow controller, filter gauge, sand expansion gauge, etc.

-

-

-

... More
Wash Water Tank-Capacity to be specified and suitable to supply water to wash specified number of filter beds at a time 12 minutes @ 600 lit/sqm/min. under a head of 12 m at under drain.

-

-

-

... More
Wash Water Pumps- Capacity to fill water tank in 1 hour with 100% standby.

-

-

-

... More
Air Blowers-Capable of delivering 600 LMP per square metre of free air, of filter area at 0.4kg / sq.cm at the under drains (100% stand by) for period of 5 min.

-

-

-

... More
Chemical House in Two Storeys

-

-

-

... More
Ground floor to accommodate 7 days' alum requirement and sundry storage. (Minimum 4 m height)

-

-

-

... More
First floor to accommodate alum and lime tanks. Chain pully block etc. (min. 5 m height)

-

-

-

... More
Solution tanks-Minimum 3 tanks (one for preparation, second for dosing and third as stand by), each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30M, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device (constant head device, strength of solution upto 10% only) conforming to I.S. 9222 Part-I 1979.

-

-

-

... More
Pure Water Sump and Pump House.

-

-

-

... More
Capacity of sump – One hour of designed flow.

-

-

-

... More
Pump House- Pump house of required size over the sump or by the side.

-

-

-

... More
Store House-Suitable for alum storage of three months and 7 days temporary storage, 7 days TCL requirement in mansoon with 20% extra capacity for other sundry articles.

-

-

-

... More
Vacuum feed type Chlorinators- Make tobe approved by MJP.

-

-

-

... More
Conforming to I.S. 10533 - A Part-II 1983

-

-

-

... More
Rate for withdrawal

-

-

-

... More
Temperature Degree 'C'

-

-

-

... More
Degree "C" Cylinders

-

-

-

... More
45 67 Tonnes

-

-

-

... More
10 6.35 9.50 110

-

-

-

... More
15 10.75 16.10 130

-

-

-

... More
20 14.50 21.24 254

-

-

-

... More
27&Above 18.70 28.12 315

-

-

-

... More
Chlorinator equipment and container room to conform to I.S. 10553 Part-I 1983.

-

-

-

... More
100% standby shall be provided.

-

-

-

... More
By pass arrangements - C.I. or M.S. pipes.

-

-

-

... More
Disposal of waste from WTP : Safe disposal arrangement to nearby nalla including cost of pipe.

-

-

-

... More
For WTP of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided , including sump, pumping machinary, rising main etc. complete.

-

-

-

... More
Drainage arrangements To decant all units of WTP with CI pipes upto boundary of each unit and further extension with RCC pipes to nearby nalla.

-

-

-

... More
Electrical installation – Both internal and external including entire plant area.

-

-

-

... More
Laboratory equipment –As per requirement (to be specified during tendering).

-

-

-

... More
Sanitary blocks – Carpet area -15 square metre minimum upto 25 Mld and 25 square metre above 25 Mld.

-

-

-

... More
Administrative block and internal road-To accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and WBM road to connect all units from main gate of plot.

-

-

-

... More
Rates given below are inclusive of up lift pressure if any and dewatering during entire work.

-

-

-

... More
All pipes conduits channel with 20% overloading.

-

-

-

... More
These rates are applicable for seismic zones 2, 3 and 4.

-

-

-

... More
All RCC structures shall be constructed in M-300

-

-

-

... More
Note: Conditions from Sr. No. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants (proposed).

-

-

-

... More
Cost of 21.12 MLD Conventional Water Treatment Plant

1

-

-

... More
Connecting Pipe for direct connect to Sump

-

-

-

... More
Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-9 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining on inside surface with outside zinc and bituminous coating. 600 mm Dia

10

-

-

... More
Providing, supplying ISI standard D.I. specials & fitting with sealing rubber gasket of S.B.R. complete with cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for D.I. pipes including all taxes etc. complete as per IS 9523 class K-12 9 ex - factory) inspection charge tranportation, CP extra. Socketed - 500 -600 mm dia

46.7

-

-

... More
Supplying labours, tools, tackles, lubricant etc. for laying and jointing DI/C.I.S/S Tyton pipes (class LA) trenches supplying rubber gasket (Rubber gaskets confirming to I.S.S.-5382-1969) and taking gasket joints including providing night guard, barrier and red light to safe guard against accident, all complete and laying of pipes is to be done as per (I.S.S. 3114 -1985) as per design, specification and direction of E/I. 600 mm Dia

20

-

-

... More
Supplying labours, tool and tackles for testing of laid CI or UPVC or HDPE or AC or DI pressure pipe all complete as per specification direction E/I 600 mm Dia

10

-

-

... More
Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I. 600 mm Dia

0.2

-

-

... More
Electrical Works for Intake, IBPS and WTP

-

-

-

... More
Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’

4

-

-

... More
Providing and erecting Vaccum circuit breaker (VCB) panel indoor type including CT ofrequired ratio for metering and protection including 3 O/C and E/F relay and high speed trip relay. 3.3 kV system 1250 Amp 25 kA

6

-

-

... More
SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries, FCBC ( Float cum boost charger)suitable for 415V +/-10%, 50 Hz , 1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled, free standing in Sheet Steel enclosure,SCR controlled , regulation +/-1% , Efficiency 75% on FLAC/ DC Instruments, Selector Switch ,Built in DC Distribution Board (6 No MCB), indication , control as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

4

-

-

... More
Iron core Oil Cooled Transformer with Copper Winding Conforming to IS 1180 (Part 1) of 2014 Supply and delivery of 11 KV/433 Volts, 22 KV/433 Volts, three Phase 50 HZ double wound oil immersed natural air cooled, core type continous rating, outdoor distribution power transformer with copper winding for voltage ratio 22-11 KV/433 volts between phases with neutral brought out at LV side. The transfer shall be contained in a mild steel plain & radiator cooled tank, conforming to IS 1180 (Part I) of 2014 with off-load tap switch for ±10% on L.V side and ±5 % on H.V.side. The transformer shall be supplied with first filling of oil and consisting of all the fittings and accessories such as Inspection cover,Oil level indicator with minimum and filling level markings, Externally operated off circuit tap changing switch with locking device & keys, H.V. Terminals- Bushings, L.V. Terminals cable box Rating plate, Two earthing terminals, Two lifting hooks etc complete as per IS 1180 (Part I) of 2014 and as amended thereafter. 1000 KVA/433

2

-

-

... More
Iron core Oil Cooled Transformer with Copper Winding Conforming to IS 1180 (Part 1) of 2014 Supply and delivery of 11 KV/433 Volts, 22 KV/433 Volts, three Phase 50 HZ double wound oil immersed natural air cooled, core type continous rating, outdoor distribution power transformer with copper winding for voltage ratio 22-11 KV/433 volts between phases with neutral brought out at LV side. The transfer shall be contained in a mild steel plain & radiator cooled tank, conforming to IS 1180 (Part I) of 2014 with off-load tap switch for ±10% on L.V side and ±5 % on H.V.side. The transformer shall be supplied with first filling of oil and consisting of all the fittings and accessories such as Inspection cover,Oil level indicator with minimum and filling level markings, Externally operated off circuit tap changing switch with locking device & keys, H.V. Terminals- Bushings, L.V. Terminals cable box Rating plate, Two earthing terminals, Two lifting hooks etc complete as per IS 1180 (Part I) of 2014 and as amended thereafter. 750KVA/433

1

-

-

... More
Iron core Oil Cooled Transformer with Copper Winding Conforming to IS 1180 (Part 1) of 2014'Supply and delivery of 11 KV/433 Volts, 22 KV/433 Volts, three Phase 50 HZ double wound oil immersed natural air cooled, core type continous rating, outdoor distribution power transformer with copper winding for voltage ratio 22-11 KV/433 volts between phases with neutral brought out at LV side. The transfer shall be contained in a mild steel plain & radiator cooled tank, conforming to IS 1180 (Part I) of 2014 with off-load tap switch for ±10% on L.V side and ±5 % on H.V.side. The transformer shall be supplied with first filling of oil and consisting of all the fittings and accessories such as Inspection cover,Oil level indicator with minimum and filling level markings, Externally operated off circuit tap changing switch with locking device & keys, H.V. Terminals- Bushings, L.V. Terminals cable box Rating plate, Two earthing terminals, Two lifting hooks etc complete as per IS 1180 (Part I) of 2014 and as amended thereafter. 200 KVA/433

1

-

-

... More
415 V, 10KA/1sec, Al busbar, 3phase 4wire LT Aux. Panel. Wall mounted. Enclosure shall be CRCA sheet, 1.6mm for non load bearing area and 2mm for load bearing area. Panel shall be compertmentalized only. Incomer= 200A TPN MCCB 1no. Outgoing feeder= 32A TPN MCB 6nos, 16A SPN MCB 6nos. Considering all metering and protection. Paint shall be as per IS 5.

3

-

-

... More
APFC Panel SITC of Automatic power factor correction panel with 125 kVAR Capacitor bank comprising with APFC relay, capacitor banks,contator,indicating lamp, power factor meter, free standing made of sheet steel enclosed, aluminium bus bar, earthing pads, complete with power & control wiring and suitable to improve the power factor of the system up to 0.98 lag.

3

-

-

... More
SITC of Automatic power factor correction panel with 125 kVAR Capacitor bank comprising with APFC relay, capacitor banks,contator,indicating lamp, power factor meter, free standing made of sheet steel enclosed, aluminium bus bar, earthing pads, complete with power & control wiring and suitable to improve the power factor of the system up to 0.98 lag.

2

-

-

... More
415V LT PCC at clear water pumping station 415 V, 10KA/1sec, Al busbar, 3phase 4wire LT Aux. Panel. Wall mounted. Enclosure shall be CRCA sheet, 1.6mm for non load bearing area and 2mm for load bearing area. Panel shall be compertmentalized only. Incomer= 100A TPN MCCB 1no. Outgoing feeder= 32A TPN MCB 6nos, 16A SPN MCB 6nos. Considering all metering and protection. Paint shall be as per IS 5.

1

-

-

... More
FCMA / HFSR Electrical Soft starter Providing erecting and giving test and trial of FCMA fully Automatic, Starter with DOL Soft Starter complete with main Contactor, VAF meter , PLC and HMI , push buttons and indications,FCMA module with bypass contactor and its control circuitry etc complete. LG 6-16 - 180 HP

4

-

-

... More
Supply , Installation, Testing and Comissioning of wall mounted Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

14

-

-

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
3.5 core 185 sq.mm

200

-

-

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
3.5 core (185.0 Sqm.mm)

675

-

-

... More
3.5 core (300.0 Sqm.mm)

185

-

-

... More
4 core (16.0 Sqm.mm)

185

-

-

... More
3 core (6.0 Sqm.mm)

180

-

-

... More
3 core (2.5 Sqm.mm)

250

-

-

... More
10 core (2.5 Sqm.mm)

250

-

-

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
3.5 core (300.0 Sq. mm)

165

-

-

... More
3.5 core (50.0 Sq. mm)

200

-

-

... More
4 core (16.0 Sq. mm)

120

-

-

... More
4 core (10.0 Sq. mm)

150

-

-

... More
3 core (25.0 Sq. mm)

175

-

-

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 core 120/150/185 Sq.mm

7

-

-

... More
3 core 120/150/185 Sq.mm

7

-

-

... More
3 core 240/300 Sq.mm

35

-

-

... More
3 core 400 Sq.mm

30

-

-

... More
3/3.5/4 x 1.5 sq.mm-6 sq.mm

30

-

-

... More
16.0 sq.mm

40

-

-

... More
2 x 10.0-16.0 sq.mm

60

-

-

... More
Galvanized Cable trays

-

-

-

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 300mm x 62.5mm x 2.0mm

205

-

-

... More
Earthing

-

-

-

... More
Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

50

-

-

... More
50mm x 6mm G.I. ( Hot Dipped ) Strip

340

-

-

... More
25mm x 6mm G.I. ( Hot Dipped ) Strip

300

-

-

... More
10 SWG G.I. ( Hot Dipped ) Wire

230

-

-

... More
Lightning Protection

-

-

-

... More
Lightening Conductor of G.I. bar of 25mm dia& 2m long

5

-

-

... More
20mm x 3mm G.I. ( Hot Dipped ) Strip

420

-

-

... More
Supply and fixing of 1.6 mm thick MS 11 kV Danger plates as per IS :2551-1982 & specification of Discom on the existing poles complete in all respectas per PWD / DISCOM specification. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

24

-

-

... More
Indoor and Outdoor Illumination System

-

-

-

... More
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy =120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR LED Street Light fixture with Minimum lumen output 15000 lm

18

-

-

... More
Providing & Fixing of IK10 IP65 protected 600 mm height LED Bollard Luminarie with base plate made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current 750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Minimum lumen output 800 lm Bollard

8

-

-

... More
Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current 750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Minimum lumen output 4500 lm Post top Luminarie

8

-

-

... More
Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr.

18

-

-

... More
Miscellaneous Items

-

-

-

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .33 KV, class C 3 mm thick with proof voltage 36 KV AC (rms) for 3 min. and Break Down Voltage 65 KV AC (rms)

20

-

-

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms)

36

-

-

... More
Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO – 9001 or above , with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1400 mm sweep. 1200 mm Sweep BEE 1 Star rated (service value =4.0 to 4.5 )

4

-

-

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm

12

-

-

... More
Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .2 x 1.5 Sq.mm Armoured With Outer Sheath in Red Color

200

-

-

... More
Cable termination

-

-

-

... More
3 core 120/150/185 Sq.mm

5

-

-

... More
3 core 120/150/185 Sq.mm

3

-

-

... More
3 core 240/300 Sq.mm

4

-

-

... More
3 core 50/70/95 Sq.mm

16

-

-

... More
3/3.5/4 x 10.0-16.0 sq.mm

12

-

-

... More
2 x 10.0-16.0 sq.mm

10

-

-

... More
Mechnical Works at Intake , IBPS and WTP

-

-

-

... More
VERTICAL TURBINE PUMP (WATER LUBRICATED) CONFIRMING TO IS1710/1989 (REAFFIRMED 2009) 1500 RPM SUITABLE FOR VERTICAL HOLLOW SHAFT SQUIRREL CAGE Supply and delivery of Vertical type water/Oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging the following duty condition as given below due to all causes with surface discharge head confirming to IS 1710 and as amended as on date with accessories as per IS 5120/1977 ( Reaffirmed 2011 ) and as amended thereafter to suit the site condition. The speed, No. of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reversible ratchet pin housing safety clutch, suction strainer etc. The Pump Bowl assembly shall be with bronze impeller running at 1450 rpm. The pump includes suitable head shaft, suitable 1.5 metre long SS line shaft required Nos. to suit the well depth, Rubber line shaft bearing of required Nos., C.I Bearing retainer of required Nos., 100 litre HDPE Pre- lubricating tank with 20mm PVC Rigid pipe connection along with GM gate valves, Suitable ERW column pipe of each 1.5m long of required Nos. to suit the well depth, Suction bell mouth of suitable size, M.S. clamps suitable for column pipe/line shaft -2 set and Spanner - 1 set etc complete FOR INTAKE -- Discharge : 522500 LPH or 8708 LPM, Head-125 M FOR IBPS -- Discharge : 522500 LPH or 8708 LPM, Head-114 M

6

-

-

... More
RATES FOR HORIZONTAL SPLIT CASTING CENTRIFUGAL PUMP (1500 RPM) confirming to IS 1520 Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing and split glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel, M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, double flap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase, 415 V, 50 Hz, 1500 RPM.

-

-

-

... More
8677.2 LPM, 59 M (at WTP)

2

-

-

... More
8744 LPM, 42 M (at WTP)

2

-

-

... More
8744 LPM, 48 M (IPS)

2

-

-

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking etc. complete. as per I.S.5312 Part I (1984) Without bypass arrangement -PN - 1.6 (a) 200 mm dia

6

-

-

... More
Providing and fixing M.S. chequerred plate flooring of following thickness supported on M.S. angles (25 x 25 x 5 mm size) including welding, cutting and fabricating the plates to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge. 6 mm thick

15

-

-

... More
Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete. Without bypass arrangement -PN-1 200 mm dia

4

-

-

... More
Lowering, laying and fixing in proper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing etc complete. (Rate for all class of valves.) 200 mm dia

4

-

-

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading fromrailway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) Without by pass arrangement - PN -1.6 200 mm dia

2

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 200 mm dia

2

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. A) 250 mm dia

6

-

-

... More
Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete. With bypass arrangement -P.N. -1.6 200 mm

4

-

-

... More
Lowering, laying and fixing in proper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing etc complete. PN-1.6

4

-

-

... More
Air Release Valve: Providing & supplying air valves as per IS 14845-2000 & MJP's standard specifications double orifice type combined with isolating sluice valve mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcannite ball seating on moulded seat ring, inlet face & drilled, excluding all taxes (central & local), insurance, third party inspection charges, loading, unloading, transportation upo to departmental store / site etc. complete.

-

-

-

... More
80 mm dia PN-1.6

6

-

-

... More
Lowering, laying and fixing in proper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing etc complete. (Rate for all class of valves.) 80 mm dia - PN-1.6

8

-

-

... More
Providing, erecting and commissioning single girder Electrically Operated Rectangular Over head Travelling Crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendant control block.

-

-

-

... More
5 T Capacity - Above 6 m upto 8 m span.

2

-

-

... More
10 T Capacity - Above 8 m upto 10 m span.

1

-

-

... More
EOT Crane : - Providing, Erecting and Commissioning Single Girder electrically Operated Circular/Rectangular over head travelling crane with 6 m Lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54 control panel and down pendant control block.

-

-

-

... More
For WTP- 5 T Capacity - Above 6 m upto 8 m span.

1

-

-

... More
Square Bar / Rail :- Providing, erecting and fixing square bar of EN 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and "J" bolts.. 40x40 mm(EN 8)

60

-

-

... More
Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-9 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating (including cost of one no. gasket for each pipe). Rate are exfactory excluding transportation, taxes & duties contractor profit and over head charges etc.

-

-

-

... More
200 mm dia

170

-

-

... More
Providing and supplying ISI standard D.I specials & fitting with sealing rubber gasket of S.B.R., complete with cast iron follower gland and M.S nut & bolts coated or otherwise protected from rusting and suitable for D.I pipes including cost of all labours and materials and transportation to stores / site, loading, unloading including all taxes, etc. complete as per I.S-9523, @10% (Including 10% C.P.) Socketed (200-300 mm dia)

417

-

-

... More
Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I. 200 mm dia

8

-

-

... More
Supplying labours, tools, tackles, lubricant etc for laying and jointing DI/C.I. S /S tyton pipes (class LA) trenches, supplying rubber gasket (Rubber gasket confirming to I.S.S -5382 -1969) and making gasket joints including providing night guard, barrier and red light to safe guard against accident all complete (Pipe to be supplied departmentally free of cost and laying of pipes is to be done as per ( I.S.S 3114-1985 ) as per design, specification and direction of E /I

-

-

-

... More
200mm dia

130

-

-

... More
250mm dia

40

-

-

... More
Ventilation System

-

-

-

... More
Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.

-

-

-

... More
300 mm sweep (900/1400 RPM)

13

-

-

... More
Fire Fighting System

-

-

-

... More
Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 4 kg

14

-

-

... More
ESR ( Elevated Service Resevoir)

-

-

-

... More
Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for ESR having capacity upto 500 cum and not more than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout,overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers, water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case from ground level to roof level, M.S. grill gate of 2 M height with locking arrangement of approved design, B.B.masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint tothe structure including roof slab, epoxy painting to internal surface and antitermite treatment for underground parts of the structure and giving satisfactory water tightness test as per I.S. code. The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-Charge.

-

-

-

... More
The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.)

-

-

-

... More
The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 / 1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks.

-

-

-

... More
For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory.

-

-

-

... More
Plain round mild steel bars grade-I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed.

-

-

-

... More
These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity

-

-

-

... More
Staging shall have to be designed with stresses of M-200 concrete for ESR. However all RCC construction should be done in M-300

-

-

-

... More
These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is stretch at shallow depth, extra provision of dewatering shall be made as per site condition.

-

-

-

... More
All conditions given in the Member Secretary's Circular No. MJP / TS-I / 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below.

-

-

-

... More
75% part rate shall be payable for reinforcement concrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete.

-

-

-

... More
The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. The scope of work, however, includes cost of erecting, laying and jointing of pipes and valves including cost of jointing materials upto 5 M beyond outer face of outermost column

-

-

-

... More
For ESR upto 500 cum capacity C.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall be used. For ESR above 500 cum capacity C.I./M.S. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti-corrosive epoxy treatment from inside and outside.

-

-

-

... More
Below mentioned rates are for foundations with individual footing with bearing capacity of 20 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is more than 5 MT/sqm and upto 10 MT/sqm. This % of 5% or 7.5% is applicable for estimation of amount of lumpsum item of ESR. For extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant DSR item.

-

-

-

... More
For Chhattarpur

-

-

-

... More
1. ESR - 1880 KL , Staging - 22 m

1

-

-

... More
2. ESR - 2270 KL , Staging - 27 m

1

-

-

... More
For Hariharganj

-

-

-

... More
1. ESR - 1520 KL , Staging - 25 m

1

-

-

... More
2. ESR - 1920 KL , Staging - 23 m

1

-

-

... More
House Service Connection

-

-

-

... More
Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in charge.

-

-

-

... More
A) Household Connection without water meter (Compression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe

-

-

-

... More
For MDPE/UPVC Pipe Service Connection on Disribution main

-

-

-

... More
(With Road Crossing) For 15 mm Service connection

15669

-

-

... More
I S I mark as per IS 779/1994 Providing, installing and giving satisfactorily field testing of domestic water meter, horizontal inferential type multijet type with magnetic drive and dry dial suitable for 50 degree temperature duly sealed against tampering complete with couplings at both ends and conforming to class B as per IS 779/1994 (VI revision) with ISI mark along with manufacturer's test certificates and guarantee certificates including cost of all labour and materials. 15 mm dia

15669

-

-

... More
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box. Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.

15669

-

-

... More
N.H. CROSSING

-

-

-

... More
Manufacturing providing and supplying spirally welded / ERW / SAW / Fabricated M.S. Pipes (Commercial Quality) including procurement of plates. Gas cutting to required size rolling, tack welding, assembling in suitable lengths to form pipes, welding on automatic welding machine and forming 'v' edge on both ends of pipe including all taxes, railway freight, insurance, unloading from railway wagon, loading into truck transport to stores / site, unloading, stacking etc. complete as per IS - 3589 and IS - 5504 as applicable as per specifications (No negative tolerance in thickness is permissible).

-

-

-

... More
a) For 100 mm dia DI pipe - Dia of Pipe : 219.10.00 mm (O. D.) 9.5 mm thick MS pipe for Casing

180

-

-

... More
b) For 200 mm dia DI pipe - Dia of Pipe : 273.10 mm (O. D.) 9.3 mm thick MS pipe for Casing

45

-

-

... More
c) For 250 mm dia DI pipe - Dia of Pipe : 323.90.00 mm (O. D.) 9.5 mm thick MS pipe for Casing

45

-

-

... More
d) For 350 mm dia DI pipe - Dia of Pipe :406.00 mm (O. D.) 10 mm thick MS pipe for Casing

45

-

-

... More
e) For 450 mm dia DI pipe - Dia of Pipe :508.00 mm (O. D.) 10 mm thick MS pipe for Casing

90

-

-

... More
Pushing of M.S. pipe of following dia for road crossing and raiway crossing by push through method in all types of strata by using hydraulic jack and drilling machine of required diameter below 3.0 m depth including lowering, laying, jointing of M.S. casting pipe including cost of labour, fuel and material, required welding machinery, tripod, chain pulley block, crane, blower,etc., transportation and dewatering etc. complete as directed by Engineer in charge but excluding cost of M.S. pipe.

-

-

-

... More
a) 200 mm to 499 mm dia MS pipe

315

-

-

... More
b) 500 mm to 1000 mm dia MS pipe

90

-

-

... More
Providing and applying primer first coat of intertol 49 W emaline 05/ 58 pipe coat or any other equivalent approved paint to the internal surface of pipeline at site, etc. complete.

-

-

-

... More
First Coat

818.37

-

-

... More
Second Coat

818.37

-

-

... More
TRENCHLESS RAILWAY CROSSING

-

-

-

... More
Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMB's.Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. (Protective coating/ lining if done that will be paid extra) Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.

-

-

-

... More
600 mm dia 12 mm thick casing pipe

55

-

-

... More
Providing and applying primer first coat of intertol 49 W emaline 05/ 58 pipe coat or any other equivalent approved paint to the internal surface of pipeline at site, etc. complete.

-

-

-

... More
a) 600 mm dia MS pipe -

-

-

-

... More
80 m X 3.142 X 0.600 (two surface)

-

-

-

... More
First Coat

276.5

-

-

... More
Second Coat

276.5

-

-

... More
Boundary Wall - For WTP ,IBPS, ESR1 , ESR2 & ESR-3 - 640 m ,

-

-

-

... More
Excavation for structures (earthwork in excavation of foundation of structures as per drawing and technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for roadwork.)

644

-

-

... More
Removal of unserviceable soil with disposal up to 1000 m (removal of unserviceable soil including excavation, loading and disposal up to 1000 m lead but excluding replacement by suitable soil which shall be paid separately as per clause 305.

264

-

-

... More
Plain / Renforced Cement Concrete in open foundation complete as per drawing and technical specifications. PCC Grade M20

32

-

-

... More
Plain / Renforced Cement Concrete in well foundation complete as per drawing and technical specifications. RCC Grade M25

292

-

-

... More
Providing 2 coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing, and taxes all complete as per building specification and direction of E/I.

4752

-

-

... More
Centering and Shuttering including strutting, propping etc. and removal of form for Foundation, footings, bases of column for mass concrete

2100

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.

2182.5

-

-

... More
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat or 16 mm square bars fitted on 25x25x6 mm M.S angle frame as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l

15939.5

-

-

... More
Estimate Of Approach Road

-

-

-

... More
E/W in Soil by manual means, (Excavation for roadway in soil using manualmeans including loading in truck for carrying of cut earth to embankment site with all lift and lead upto 1000 meters) (ii) including Royality @ Rs. 30.0 Per cum, cost of watering, rolling & compaction

423.28

-

-

... More
Granular sub-base with close graded material, plant mix method (construction of granular sub-base by providing close graded material, mixing in mechanical mix plant at OMC, carriage of mixed material to work site, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401) (i) for grading-I material

60

-

-

... More
Water bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes/smooth 3 wheeled steelroller in stages to proper grade and camber, applying and brooming requisite type of screening /binding materials to fill up the interstics of coarse aggregate, watering and compacting to the required density) (A) By manual means(i) Grading-I (a) Using Screening crushable type such as moorum or gravels(with vibratory roller)

10

-

-

... More
Dry Lean Cement Concrete Sub -Base Construction of Dry lean cement concrete Sub- base over coarse and fine aggr o IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed OF 15:1, aggregate gradation after blending gregate to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to berless than 10 Mpa at 7 days, mixed in a batching plant transported toasite to site laid with a paver with electronic sensor compacting with 8-10 tonnes vibratory rolle finishing and curing.

60

-

-

... More
VALVE CHAMBER

-

-

-

... More
Construction of B.W masonry valve chamber of size 1.20X0.90X1.50 m.as per enclosed annexure. (up to 300 mm dia.)

419

-

-

... More
Construction of B.W. masonry valve chamber of size 1.50x1.20x1.80 mt. as per enclosed annexure.(above 300 mm Dia.)

131

-

-

... More
Thrust Block

-

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level. 1:2:4( 1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size)

468.14

-

-

... More
Sludge Settling Tank

-

-

-

... More
Providing P.C.C M-10 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade-III (50mm to 25mm), size clean coarse sand of F.M 2.5 to 3 including screening, shuttering mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.

2.12

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level. 1:1.5:3 ( 1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) Top Slab

11.1

-

-

... More
Providing M.S. foot rests inclding fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 (1cement: 3coarse sand: 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20 mm square bar

3

-

-

... More
Providing and fixing in position pre-cast RCC manhole cover and frame of required shape and approved qrality . Circular shape 560mm internal dia.

1

-

-

... More
Providing and Fixing soil ,waste and vent pipe: 75 mm dia sand cast iron socket & spigot pipe

5

-

-

-

-

-

... More
Supply,Installation,Testing & Commissioning (SITC) of centralized SCADA Monitoring center equipment

-

-

-

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 1200 mm X 800 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following:- Programmable Logic Controller (PLC) with Dual Hot Redundant CPU, Power supply, Communication Module, IO & Processor rack (Standard DC), Back up Interface/Expansion Module, Rack (Backplane) 10 slots for IO and Processor. SCADA software shall have facility VPN, OPC, Smart Client, Web Enabled, Automation Report Generation, Archiving, Treands, Data Logging, etc.

1

-

-

-

-

-

-

-

-

-

-

-

-

-

-

... More
MCB 16A DP

-

-

-

... More
MCB 6A DP

-

-

-

... More
SMPS 100-240VAC/ 4.5A / 24 VDC

-

-

-

... More
Selector Switch (Auto/Manual) & Local / Remote

-

-

-

... More
Control Relays

-

-

-

... More
Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with

-

-

-

... More
Electronic Hooter

-

-

-

... More
Control Transformer 200VA

-

-

-

... More
Emergency STOP Push Button

-

-

-

... More
Panel Cooling Fan & Filter

-

-

-

... More
Panel Light with Door Switch, 7W

-

-

-

... More
Control Indication Lamp for 24VDC, 220VAC

-

-

-

... More
Push Button

-

-

-

... More
Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc

-

-

-

... More
Panel Hardware, lugs, terminations, ferrules, name plate Etc.

-

-

-

... More
UTILITY SOCKET 16A, 3 PIN

-

-

-

... More
HMI Display 15 Inch, Colour

-

-

-

... More
Isolators Dual Output, 24VDC

-

-

-

... More
Ethernet Switch ( Managed)

-

-

-

... More
Operator Station including, Core i7 processor, 8 GB RAM, 1TB SSD, DVD RW Drive, RS-232/485/RJ45 Port, 1 Parallel Port, 4 nos. USB Port, 2x Ethernet Cards, Keyboard, Optical mouse, 32'' LED monitor, Latest windows professional, Anti Virous, etc.

-

-

-

... More
Engineering Station including, Core i7 processor, 8 GB RAM, 1TB SSD, DVD RW Drive, RS-232/485/RJ45 Port, 1 Parallel Port, 4 nos. USB Port, 2x Ethernet Cards, Keyboard, Optical mouse, 32'' LED monitor, Latest windows professional, Anti Virous, etc.

-

-

-

... More
Run Time & Development Programming and Troubleshooting software for PLC, HMI, SCADA, VPN, Web Client - OWS

-

-

-

... More
Black and white, A4 Size Laser Printer, copier Scan. Hi-Speed USB 2.0 port; built-in Fast Ethernet 10/100Base-TX network port; built-in WIFI 802.11b/g/n

-

-

-

... More
Online UPS 5 KVA with 60 min Backup time.

-

-

-

... More
SITC of Intelligent Manageable Ethernet Switches providing 24 x 10/100/1000 Fast Ethernet ports- and 2 dual purpose uplink (provision for Copper / Fibre Giga connectivity) with LAN based Software. The LAN based S/W supports enhanced integrated security, including Network Admission Control (NAC), advanced quality of service (QoS), availability and scalable management to enable new converged applications

10

-

-

... More
Supply, Installation, Testing, Intgeration & Commissioning of 49" LCD monitor at Conf. Room for display of total water system (Online)

9

-

-

... More
Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, 3 Phase 415 V, 50 Hz with 2 hour backup SMF battery bank as per specification 7.5 KVA

2

-

-

... More
Surveillance System

-

-

-

... More
Desiging, supplying, installing, commissioning & testing of CCTV IR water proof camera suitable for upto 100ft. with control key board, DVR, Hard Disk,cables, UPT transreceivers etc. complete with not less than following specifications. 1. Four numbers of IP Camera with night vision functionality with range up to 30 meters. Camera construction shall be suitable for weather proof outdoor installation. 2. Eight Channel DVR with metal body construction, having software features of motion detect recording. 3. 3.5 inch 2 GB HDD 4. 8 port POE Switch 5. 32 inch LED Screen, Keyboard & mouse.

12

-

-

... More
SITC of GPRS gateway PLC based along with necessary software and hardware, Controls 50 nos. SLC, 140-270Vac, CE/FCC certified communication module, Battery backup up to 24 hours, On-board 2 nos. current (4-20mA), and 2 nos. antilog voltage channel(1-10V), On-board RS485 Modbus interface Three Phase

4

-

-

... More
Telephone Accessories (WG-TW/TA) Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete.

1

-

-

... More
Compact RTU complete with DI, DO, AI and modbus communication ports and power supply. // Compact RTU for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic, DNP3, IEC60870-5-104 and Communication protocols, on-board I/O (8 DI, 4 DQ, 4 AI), configuration and diagnostics per web interface, RJ45 port, mobile communications antenna (GSM/UMTS), Mini SIM card, with adapter Micro SIM card also, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floor mounted along with wiring and related accessories and arrangement of mounting of RTU, Modem and having IP-5X Protection. Panels shall be self-fabricate type only with Canopy.

1

-

-

... More
Supply, Installation, Testing and Comissioning of Window type Air conditioners as per BEE star rating complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 230 V +/- 10% with low & high voltage cutoff and 50 Hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation R-32/R-410 Green Refrigerant with Scroll / rotary compressor complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1.5 TR ISEER not less then 3.0

4

-

-

... More
SITC of UL 10th edition / EN54 / VDS certified Microprocessor based inteligent, Analogue addressable,modular, expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 125 detectors & devices with Loop length up to 1 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, LCD/LED unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 2 Loop Pannel

1

-

-

... More
Ultrasonic level transmitter raddar type level transmeter for raw water pumping station

-

-

-

... More
Designing, Supplying, Installing, commissioning & testing of Ultrasonic Raddar type Ultrasonic level transmitter CE marked with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement.

3

-

-

... More
Output-4-20 mA / HART

-

-

-

... More
Power supply - 24V DC ext.

-

-

-

... More
Display - 4" LED

-

-

-

... More
Range- 0 to …30... mtrs

-

-

-

... More
Accuracy - +/- 0.25% of Full Scale or better

-

-

-

... More
Enclosure- IP 68

-

-

-

... More
Mounting - On PLC panel

-

-

-

... More
Pressure Transmitter for raw & pure water pumping station

-

-

-

... More
Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement.

28

-

-

... More
Output 4-20 mA / HART

-

-

-

... More
Power supply - 24V DC ext.

-

-

-

... More
Display - 4" LED

-

-

-

... More
Accuracy - +/- 0.1 % of full scale or better

-

-

-

... More
Enclosure- IP 68

-

-

-

... More
Pressure Guages at outlet line:- Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. Pressure gauge (150 mm dia)

35

-

-

... More
Instrumentation cable (2 pair x 1sq.mm):- Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 Pair x 1 sq.mm as per IS 694 copper Shielded twisted, multistranded armoured cable on wall in GI tray or on ground.

800

-

-

... More
Cable Trays:-Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 100mm x 50mm x 1.6mm

800

-

-

... More
PLC panel for Raw water pump House with two Pumps

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1000 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color. The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration. The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at Raw water Pumphouse. PLC shall have Ethernet port & protocal for Modbus TCP communication with following IO.

6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

... More
7 inch color TFT HMI complete with programming shall be provided to interact with PLC. The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of pump house.

-

-

-

... More
MCB 10A DP

-

-

-

... More
MCB 4A DP

-

-

-

... More
24 VDC Power Supply 10A

-

-

-

... More
Push Buttons

-

-

-

... More
Selector Switch

-

-

-

... More
Control Contactor

-

-

-

... More
Annunciator with 6 Windows

-

-

-

... More
NO to NC Type

-

-

-

... More
Electronic Hooter

-

-

-

... More
Control Transformer

-

-

-

... More
Emergency PB

-

-

-

... More
Panel Cooling Fan

-

-

-

... More
Panel Light with Door Switch

-

-

-

... More
Control Indication Lamp

-

-

-

... More
Wiring + TB etc

-

-

-

... More
Hardware

-

-

-

... More
Scada system for Raw water pump House

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of SCADA System for pump house. Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares. PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 & Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license.

6

-

-

... More
SCADA Software of reputed company with developer & runtime license with minimum 256 number of Tags with following features & functions

-

-

-

... More
1. Supervise real-time data in the form of graphical presentation

-

-

-

... More
2. Control pumping processes locally or through Remote locations

-

-

-

... More
3. Dynamic process Graphic, It should resemble the process mimic. SCADA should have good library of symbols so that develop the mimic as per required. When operator sees the screen he should know what’s going in plant.

-

-

-

... More
4. Alarm summery & Alarm history, SCADA system must be able to detect, display, and log alarms and events. When there are problems the SCADA system must notify the operators to take corrective action.

-

-

-

... More
5. Acquire real-time data as well as logs data with Real time trend & Historical time trend.

-

-

-

... More
6.Web Connectivity, Real-time displays can be accessed on remotely attached PCs and notebooks using internet.

-

-

-

... More
SCADA Programming shall be done so as operator can visualize and control complete pump house operation from operator desk. All important alarms & events shall be logged. All the data from field instruments & equipments shall be logged. There shall be provision to take reports in required formats of real time & historical data, events & alarms.

-

-

-

... More
There shall be provision of broadcasting messages, emails of reporting information. There shall be provision of access security. An Industrial grade Din rail mounting ethernet switch with 5 ports shall be provided. An Industrial grade modem with 4G/5G GSM connectivity shall be provided.

-

-

-

... More
Ultrasonic level transmitter for pure water pumping station

-

-

-

... More
Designing, Supplying, Installing, commissioning & testing of Ultrasonic level transmitter CE marked with following technical parameters at pure Water Pump House and Interfacing with PLC panel including Mounting accesories.

5

-

-

... More
Range- 0 - 5 mtrs

-

-

-

... More
Output-4-20 mA / HART

-

-

-

... More
Power supply - 24V DC ext.

-

-

-

... More
Display - 4" LED

-

-

-

... More
Accuracy - +/- 0.25% of Full Scale or better

-

-

-

... More
Temp.- With Inbuilt temp compensation

-

-

-

... More
Enclosure- IP 68 weatherproof

-

-

-

... More
Mounting - Top/above FSL of Tank

-

-

-

... More
Open channel type ultrasonic flowmeter with FIT

-

-

-

... More
Design, Supply, Installation, Testing & calibration of open chanel type ultrasonic flow Transmitter CE marked with following technical parameters at Raw Water channel and Interfacing with PLC panel including mounting arrangement.

2

-

-

... More
Range- 0 - 5 mtrs

-

-

-

... More
Output-4-20 mA / HART

-

-

-

... More
Power supply - 24V DC ext.

-

-

-

... More
Display - 4" LED

-

-

-

... More
Accuracy - +/- 0.25% of Full Scale or better

-

-

-

... More
Enclosure- IP 68

-

-

-

... More
Providing, installation, testing and commissioning of Level Switch (Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminium Rigid for lengths of up to 3 Mtr.

4

-

-

... More
pH Analyser

-

-

-

... More
Design, Supply, Installation, Testing of pH analyser as per IUPAC( International Union for Pure & Applied Chemistry)at A.F. and Interfacing with PLC panel including mounting arrangement. Range : 0 ‐14 , pH Accuracy : Better than 0.1% of full scale , Supply Voltage : 24V dc, Output : 4‐20 mA /HART As per IEC 61000-6-2 & IEC 61000-6-3

4

-

-

... More
Turbidity Analyser

-

-

-

... More
Design, Supply, Installation, commissioning, testing of Turbidity Anayser as per ISO 7027 scattering light method at A.F. and Interfacing with PLC panel. Turbidity analyser shall comprises of 3 components i.e. sensors,signal distributor and transmitter with indicator. with 2 Outputs, 1 to PLC & anather to Local Display with mounting arrangement.

2

-

-

... More
Overall Range : 0 ‐ 2000 NTU

-

-

-

... More
Accuracy : +/‐ 0.02 NTU

-

-

-

... More
Supply Voltage : 230 V ac

-

-

-

... More
Output : 4‐20 mA /HART

-

-

-

... More
Residual chlorine analyser

-

-

-

... More
Design, Supply, Installation,Testing of Residual chlorine analyser / meter must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors,flow through assembly and transmitter with indicator and gives 2 outputs one to Local display & other to PLC including Mounting arrangement. Overall Range : 0 ‐ 8 mg/l (ppm) Accuracy : 2% of full scale Supply Voltage : 230 V ac Output : 4‐20 mA Membrane free sensor of 2 gold plated electrodes for long termstability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required.

2

-

-

... More
PLC Panel for WTP Automation

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1200 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color. The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration. The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at WTP Plant (raw water monitoring, alum dosing control, clariffaculator operation & control, recirculation & mud pump operation). PLC shall have Ethernet port & protocal for Modbus TCP communication with following IO

3

-

-

-

-

-

-

-

-

-

-

-

-

-

-

... More
10 inch color TFT HMI complete with programming shall be provided to interact with PLC The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of WTP plant.

-

-

-

... More
MCB 16A DP

-

-

-

... More
MCB 10A DP

-

-

-

... More
MCB 4A DP

-

-

-

... More
24 VDC Power Supply 10A

-

-

-

... More
Push Buttons

-

-

-

... More
Selector Switch

-

-

-

... More
Control Contactor

-

-

-

... More
Annunciator with 12 Windows

-

-

-

... More
NO to NC Type

-

-

-

... More
Electronic Hooter

-

-

-

... More
Control Transformer

-

-

-

... More
Emergency PB

-

-

-

... More
Panel Cooling Fan

-

-

-

... More
Panel Light with Door Switch

-

-

-

... More
Control Indication Lamp

-

-

-

... More
Wiring + TB etc

-

-

-

... More
Hardware

-

-

-

... More
SCADA system for WTP

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of SCADA System for WTP Plant, Sand Filter beds & pump house. Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares. PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 & Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license.

3

-

-

... More
SCADA Software of reputed company with developer & runtime license with minimum 512 number of Tags with following features & functions.

-

-

-

... More
1. Supervise real-time data in the form of graphical presentation.

-

-

-

... More
2. Control WTP processes locally or through Remote locations.

-

-

-

... More
3. Dynamic process Graphic, It should resemble the process mimic. SCADA should have good library of symbols so that develop the mimic as per required. When operator sees the screen he should know what’s going in plant.

-

-

-

... More
4. Alarm summery & Alarm history, SCADA system must be able to detect, display, and log alarms and events. When there are problems the SCADA system must notify the operators to take corrective action.

-

-

-

... More
5. Acquire real-time data as well as logs data with Real time trend & Historical time trend.

-

-

-

... More
6.Web Connectivity, Real-time displays can be accessed on remotely attached PCs and notebooks using internet.

-

-

-

... More
SCADA Programming shall be done so as operator can visualize and control complete pump house operation from operator desk. All important alarms & events shall be logged. All the data from field instruments & equipments shall be logged. There shall be provision to take reports in required formats of real time & historical data, events & alarms.

-

-

-

... More
There shall be provision of broadcasting messages, emails of reporting information. There shall be provision of access security. An Industrial grade Din rail mounting ethernet switch with 5 ports shall be provided. An Industrial grade modem with 4G/5G GSM connectivity shall be provided.

-

-

-

... More
Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, 3 Phase 415 V, 50 Hz with 2 hour backup SMF battery bank as per specification 20 KVA

1

-

-

-

-

-

... More
Ambient Air Quality Monitoring- For parameters PM-2.5 & PM-10, SO2, NO2, CO from NABL approved laboratory and submission of report complete in all respect.

65

-

-

... More
Ambient Noise Quality Monitoring - To Identify sources of noise, Noise due to traffic/transportation of vehicles, Noise due to heavy equipment operations, Duration and variations in noise over time etc. the equivalent noise levels shall be monitored (Lday and Lnight in Leq dBA) from NABL approved laboratory and submission of report complete in all respect

65

-

-

... More
Surface Water Monitoring– Collecting representative sample and Physical & Chemical testing of Parameter from NABL approved laboratory as per CPHEEO manual: PH, TDS, Electrical Conductivity (EC), Taste & Odour, turbidity, magnesium, Total hardness, total alkalinity, chloride, Dissolved Oxygen (DO), sulphate, nitrate, fluoride, Calcium, Iron, Pesticide, Manganese, Cooper, Aluminium, Residual Chlorine, Zinc, phenolic compound, Arsenic, Cadmium, Chromium, cyanides, lead, selenium, Mercury.

15

-

-

... More
Surface Water Monitoring Collecting representative sample and Bacteriological Parameter testing of water from NABL approved laboratory as per CPHEEO manual: Total coliforms, faecal coliforms

15

-

-

... More
Drinking Water Monitoring– Collecting representative sample and Physical & Chemical testing of Parameter from NABL approved laboratory as per CPHEEO manual: PH, TDS, Electrical Conductivity (EC), Taste & Odour, turbidity, magnesium, Total hardness, total alkalinity, chloride, Dissolved Oxygen (DO), sulphate, nitrate, fluoride, Calcium, Iron, Pesticide, Manganese, Cooper, Aluminium, Residual Chlorine, Zinc, phenolic compound, Arsenic, Cadmium, Chromium, cyanides, lead, selenium, Mercury.

15

-

-

... More
Drinking Water Monitoring Collecting representative sample and Bacteriological Parameter testing of water from NABL approved laboratory as per CPHEEO manual: Total coliforms, faecal coliforms

15

-

-

... More
Tree plantation in Water Treatment Tlant Premises

-

-

-

... More
1)Polyalthia (Polyalthia Longifolia)

80

-

-

... More
2)Indian Date (Phoenix sylvestris)

45

-

-

... More
3) Conifer (Pinophyta)

50

-

-

... More
TOTAL CARRIAGE

-

-

-

18690.88

-

-

... More
Aggregate

5632.64

-

-

... More
cement

785.89

-

-

... More
Bricks

253.48

-

-

... More
Operation and Maintenance

-

-

-

... More
Carrying out Operation and Maintenance of work for a period of 5 years including cost of all Manpower, Repair and Maintennace Cost, Fuel cost for Suction cum Jetting Trucks required for Collection and Conveyance of Septage from each Households, Occupational health and safety such as – (i) Capacity building on safe work practices, (ii) Safety equipment and accessories, (iii) Administrative control measures and (iv) Personal Protective Equipment (PPE) as per specifications and as directed by Engineer-In-Incharge (The bid will be rejected if bidder failed to quote the O&M details mentioned below)

-

-

-

... More
O&M for 1st Year

4734050

-

-

... More
O&M for 2nd Year

4831817.86

-

-

... More
O&M for 3rd Year

4929585.71

-

-

... More
O&M for 4rth Year

5027353.57

-

-

... More
O&M for 5th Year

5125121.43

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.