State Building Construction Corporation Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

State Building Construction Corporation Limited - JSBCC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date30 Dec 2022
Closing Date18 Jan 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)

999.19

-

-

... More
Granular Sub-Base with Graded Material (Table:- 400-1)Plant Mix Method Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.Rate per cum for grading-I Material

454.4

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

681.6

-

-

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all omplete as per the direction of Engineer-in-charge.

112.4

-

-

... More
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

340.8

-

-

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing

340.8

-

-

... More
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

36

-

-

... More
Providing P.C.C. (1:3:6) in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed , placed in foundation and compacted by vibrating curing, for 14 days.)nas per building specification and direction of Engineer-in-charge.

199.52

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)

2.51

-

-

... More
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 1.4.8 (1 Cement :4 coarse sand :8 graded stone agregate 40 mm nominal size)

182.39

-

-

... More
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

5.6

-

-

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

450

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

42.49

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)

74.85

-

-

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.

-

-

-

... More
All works upto plinth level

577.79

-

-

... More
All works above plinth level upto floor V level

2610.08

-

-

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein.

2552.24

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete

476.41

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1169.49

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform

10482.54

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)

11.83

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers

6832.18

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts

5035.4

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases

324

-

-

... More
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))

99.26

-

-

... More
Providing Tor steel reinforcement of 10mm.28mm,32mm dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))

103.65

-

-

... More
Providing Tor steel reinforcement of 12mm.16mm,20mm,25mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))

298.05

-

-

... More
Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.

178.95

-

-

... More
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.

6.3

-

-

... More
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.

2469

-

-

... More
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in superstructure and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

255.23

-

-

... More
Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.

6931

-

-

... More
Extra for brick work for each consecutive floor above first floor including watering & scaffolding all complete as per direction of E/I

2164.16

-

-

... More
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary

6931

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

2098.2

-

-

... More
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.

44.04

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

1040

-

-

... More
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)

3257.1

-

-

... More
Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.

382.5

-

-

... More
Providing and fixing aluminium work for doors,windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :

-

-

-

... More
For fixed Portion

-

-

-

... More
Anodised aluminium (anodised trasparent or dyed to required shade acording to IS: 1868 , minium anodic coating of grade AC 15)

9051.16

-

-

... More
For shutters of doors,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).

-

-

-

... More
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

9051.16

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:

-

-

-

... More
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately Profile B

243.6

-

-

... More
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.

100.8

-

-

... More
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for 127

105.6

-

-

... More
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-incharge (panneling to be paid127 separately).

69.12

-

-

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of

-

-

-

... More
E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.

1.44

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge

17.28

-

-

... More
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm

368

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete: 300x10 mm

368

-

-

... More
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper

225

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.

24

-

-

... More
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm

368

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with

368

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

150

-

-

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36KGto 80KGand door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

6

-

-

... More
Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete: 200 mm weighing not less than 240 gms

368

-

-

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on backside of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge,all complete

17

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

837.01

-

-

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness.The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame

460.35

-

-

... More
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.

146.48

-

-

... More
Providing and fixing aluminium extruded tubular and other aluminium sections as per the Achitectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS74, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). Designing, fabricating, testing, protection, installing and

4822.39

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.

-

-

-

... More
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

120.54

-

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:

-

-

-

... More
a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.

-

-

-

... More
b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.

-

-

-

... More
c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per pecification and drawing

-

-

-

... More
The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

120.54

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:

-

-

-

... More
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:

-

-

-

... More
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc.,

-

-

-

... More
enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.

-

-

-

... More
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.

-

-

-

... More
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr

-

-

-

... More
2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.

-

-

-

... More
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml

-

-

-

... More
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm

-

-

-

... More
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site.

-

-

-

... More
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

805.16

-

-

... More
Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of lime morter (1:l:1) ( Lime putty : surkhi: coarse sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.

72

-

-

... More
Providing and laying 25mm. thick kotah stone riser of steps, skirting and pillers of approved size, texture and colour over 12 mm thick cement morter (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.

12.6

-

-

... More
Providing and laylng Doublecharge vitrrfied floor tiles in diiierent sizes (thickness to be i specrfred by the manufacturer) with water absorption less than 0.08% and conforming to lS 15622 / ISO 13006 of approved make in all colours and shades laid on 20mrn thick cement mortar 1 4 (1 cement:4 coars sand) jointing with grey cement slurry @ 3.3 kg/ sqm including I grouting the joints with white cement and matching pigments etc complete Size of tile 600x600 mm

5927.92

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

4913.23

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

614.37

-

-

... More
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 SQM

34

-

-

... More
Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work

62

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

78

-

-

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade

4.95

-

-

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cementDark shade pigment using ordinary cement

504

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent

715.74

-

-

... More
Providing & Fixing flexible Conductive PVC sheet flooring of Armstrong/ Forbo/ Polyflor having a total thickness of 2mm and weight of 3kg/m².Colors and pattern detail shall be dispersed throughout the thickness of the wear layer. It shall conform to Group P of Wear Resistance as per EN 649, Flammability of class Bfl-s1 as per EN 13501-1, Slip resistance as per DIN 51130 group of R9 , having REACH Registration No, 1907/2006 contains no substance mentioned in SVHC list. Impact sound reduction of 3 dB as per ISO 140-8, Residual indentation of 0.05 mm as per EN 433, Color fastness rating ≥6 as per ISO 105-B02, Vertical resistance(R1) less than 1 x 10⁶- 1x 10⁸Ω as per EN 1081, and surface resistance less than 1 x 10⁶- 1x 10⁸ Electrical insulation to ground greater than 50 kΩ as per VDE 0100, Static electrical charge of ≤2.0kV as per EN 1815, Thermal resistance of 0.04m²K/W as per EN 12667, Thermal conductivity of 0.25 W/mK. Equivalent to Armstrong PASTELL. Installation:It is important to ensure the sub floor on which the sheet is being laid is smooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor the same should be leveled by self leveling compound. The moisture level present in the subfloor should be less than 8% before installation of the floor. The sheet should be laid using adhesive recommended by company.Each row of tiles/strip of floor covering must be linked crosswise with a continuous copper strip. Individual rows/strips must be at least 3 m² in size and linked to the rest of the area with a copper tape. In rooms of up to 40 m², connection points for equipotential bonding should be provided in at least one point in the room. Approv make- Armstrong, Polyflor, Forbo

191.03

-

-

... More
Supply and installation of Wallflex PUR Vinyl Sheet wall covering manufactured by Armstrong World Industries, Inc, 1.5m wide, having a nominal total thickness of 1mm. The nominal thickness of the wear layer would be 1mm. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVC, Plasticizers, Urethane, color pigments and filler calendared to form a sheet. Colors shall be dispersed throughout the thickness of the wear layer. Wallflex shall conform to Group M of Wear Resistance as per EN 660-2, Fire resistance of group 2 as per AS/NZS3837, Residual indentation of ≤0.10mm as per EN433, curling after exposure to moisture ≤8mm as per EN434, Seam strength of mean≥240N/50mm as per EN684.Make of : Armstrong/Polyflor/Forbo

1490

-

-

... More
Supply and installation of PVC sheet flooring 2 metre wide and overall thickness of 2mm of Armstrong/ Forbo/ Polyflor. The product should be homogeneous and single layered. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVCwith DIAMOND 10 technology, Plasticizers without DOP, Urethane, color pigments and filler calendered to form a sheet. Product shall conform to group "T" wear resistance as per EN 649, Flammability resistance of class Bfl-s1 as per EN13501-1, Dynamic coefficient of friction of class DS as per EN 13893, Impact sound reduction of 3dB as per ISO 10140, Slip Resistance of class R9 as per DIN 51130, Color fastness rating of ≥6 as per ISO 105-B02, total weight being 3.3 kg/m2 as per EN430. The product shall be suitable for applications in class 23/34/43 areas as per EN685. Product shall exhibit antistatic behaviour, resistance to bacteria,resistance to chemical, resistance to staining,suitability to castor chair. Equivalent to Armstrong Simpurity Installation- It is important to ensure the subfloor on which the sheet is being laid is smooth, flat, hard and free from moisture, grease etc. In case of uneven subfloor the same should be levelled using self leveling compound which will charged extra. The moisture present in the subfloor should be less than 8% before installation of the floor. dhesive. The installation shall be undertaken as per manufacturers installation instructions.

1503.61

-

-

... More
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.

32.72

-

-

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

17437.69

-

-

... More
Providing 1.5mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I.

32.72

-

-

... More
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

8993

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

8039.29

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

23393.29

-

-

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work

23393.29

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer

23393.29

-

-

... More
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)

8993

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

10647.09

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. Two or more coats on new work

3824.64

-

-

... More
Providing two coats of oil bond Distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone of fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification direction of E/I

429.6

-

-

... More
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.

909.6

-

-

... More
1) Surface preparation by grinding machine, cleaning , crack filling etc. complete

-

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :

-

-

-

... More
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.

-

-

-

... More
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry

1861.89

-

-

... More
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-

-

-

-

... More
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.

-

-

-

... More
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.

-

-

-

... More
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured."

-

-

-

... More
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.

-

-

-

... More
The Watqrproofing Brand:*Sila Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.

-

-

-

... More
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)

-

-

-

... More
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems

-

-

-

... More
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc

2740

-

-

... More
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr

2740

-

-

... More
Provrding and filling of Groove between 25 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent

2740

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

17

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

17

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75 x75 mm deep chase

525.28

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) complete as per design.

80

-

-

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.

-

-

-

... More
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.

-

-

-

... More
With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100 ) specifications

1408

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes ,finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :

-

-

-

... More
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)

1609

-

-

... More
Providing & fixing Rockfone Stonewool Acotsical Ceiling PACIFIC High NRC (0.80), Fire Rating A1 (EN 13501-1), RH 100% (No visible deflection in high humidity), Superior Class Light Reflection, Sag Resistant 12mm thick Ceiling Tiles of size 600x600 A-Edge (Square) with AntiBacterial Properties & M1 Class Emission Certification made up with Natural Stone (Bassalt Rock) a complete Green Product & perfect suitable for any kind of False Ceiling application in builiding & costruction. The Visible side is a smooth white painted fleece, the Rear side: back fleece with complete facctory finish Painted edges.

2512

-

-

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions.

-

-

-

... More
The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063).

-

-

-

... More
Floor Joint of 100 mm gap.

49.8

-

-

... More
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).

-

-

-

... More
Wall Joint of 100 mm gap.

34.2

-

-

... More
Providing and fixing of expansion joint system approved make and manufacture for various roof location as per drawings and direction of Engineer-In-Charge. The joints will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides watertight roof to roof roof to corner joint cover expansion control system that is capable of accommodating muitidirectional seimic movement without stress to its compnent. system shall consist of metal profiles that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions.

-

-

-

... More
The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The joints.

-

-

-

... More
Roof Joint of 100 mm gap.

17.2

-

-

... More
Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 200 mm wide.

101.2

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 14.14.2-150 mm dia

186

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia

90

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge

10.01

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge

10.01

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge

10.01

-

-

... More
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area

90

-

-

... More
BRICKS ( 8 KM )

582.17

-

-

... More
CHIPS ( 22 KM )

3925.96

-

-

... More
STONE METAL (22 KM)

81.55

-

-

... More
SAND ( 22KM )

4004.11

-

-

... More
SAND ( 10KM )

291.76

-

-

... More
Bed Lift/ 20 Passengers Speed-in m/sec-1.5

4

-

-

... More
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.

-

-

-

... More
(a) From 0.00 M to 50.00 M below G.L.

150

-

-

... More
(b) From 51.0 M to125.00 M

225

-

-

... More
(c) From126.0 M to150.00 M

75

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia

75

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge

6

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia

6

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp

6

-

-

... More
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP

3

-

-

... More
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. 5HPto10 HP

3

-

-

... More
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.

390

-

-

... More
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.

345

-

-

... More
HORTICULTURE WORK

-

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). (Mode of measurement sectional measurement after required compaction)

423

-

-

... More
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

89.03

-

-

... More
Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

89.03

-

-

... More
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of / and manure before and after flooring trench with water (excluding cost of imported earth, sludge or manure)

920

-

-

... More
Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment)

508

-

-

... More
Supplying and stacking at site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of I.S. designation 4.75 mm

157

-

-

... More
Mixing earth and sludge or manure in proportion specified or directed.

379

-

-

... More
Spreading of sludge, dump manutre or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately)

379

-

-

... More
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rought dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.

150.8

-

-

... More
Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). In rows 5 cm apart in either direction.

150.8

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 %) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)

-

-

-

... More
Holes 1.2 m dia. And 1.2 m deep.

85

-

-

... More
Holes 60 cm dia. And 60 cm deep.

45

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)

105

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)

-

-

-

... More
Trees

130

-

-

... More
Shrubs / Creeps

87

-

-

... More
EIECTRICAL WORK

-

-

-

... More
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C

1920

-

-

... More
(Approved Make : Finolex/ RR Kable/ Polycab / Skytone / KEI / Havells)

-

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.

60

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

5560

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

2810

-

-

... More
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required

-

-

-

... More
CIRCUIT / SUBMAIN WIRING

-

-

-

... More
2x1.5 sq mm + 1x1.5 sq mm earth wire

3750

-

-

... More
2x2.5 sq mm + 1x2.5 sq mm earth wire

3180

-

-

... More
2x6 sq mm + 1x6 sq mm earth wire.

100

-

-

... More
2x10 sq mm + 1x6 sq mm earth wire.

120

-

-

... More
2x16 sq mm + 1x6 sq mm earth wire.

480

-

-

... More
4x2.5 sq mm + 2x2.5 sq mm earth wire

1640

-

-

... More
4x6 sq mm + 2x6 sq mm earth wire.

360

-

-

... More
4x10 sq mm + 2x6 sq mm earth wire.

360

-

-

... More
4x16 sq mm + 2x6 sq mm earth wire.

750

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

570

-

-

... More
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (approved make : AKG / BEC / Ppecision / Polycab)

-

-

-

... More
20mm dia

200

-

-

... More
25mm dia

4200

-

-

... More
32mm dia

100

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (approved make : Legrand (Myrius) / Clipsal (C Vivace / Zencelo) / ABB (Classic Lumina ) / Wipro- North west (Stylus) / Anchor roma / MK (Wraparound Plus)

-

-

-

... More
5/6 amps one way switch

661

-

-

... More
15/16 amp one way switch

555

-

-

... More
5/6 amp 3 pin socket outlet

661

-

-

... More
5/16 amp 6 pin socket outlet

555

-

-

... More
Telephone Socket Outlet

1

-

-

... More
TV anteena Socket Outlet

19

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

250

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

1222

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.

20

-

-

... More
4/5 Module (78mm x140mm x 50mm)

947

-

-

... More
6 Module (78mmX205mmx50mm)

148

-

-

... More
8/9 Module (78mmX230mmx60mm)

32

-

-

... More
12 Module (135mmX205mmx60mm)

39

-

-

... More
Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.

250

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

20

-

-

... More
Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required.

20

-

-

... More
Installation, testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted. copper conductor single core cable and earthing etc. as required.

20

-

-

... More
Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as required.

50

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

20

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply)

109

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (approved make : B.E.C. / AKG / Ppecision / RMCON)

-

-

-

... More
20mm dia

200

-

-

... More
25mm dia

2040

-

-

... More
Supply & drawing following sizes of FR PVC insulated copper conductor single core cables in existing surface/recessed steel / PVC conduit including dismantling as required.

-

-

-

... More
2 x 1.5 sq.mm

200

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Approved make : Hager / Legrand / L & T / Schneider / Polycab)

-

-

-

... More
8 Way Double Door

4

-

-

... More
12 Way Double Door

16

-

-

... More
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 Way (4+18), Double Door Horizontal Type

15

-

-

... More
8 Way (4+24), Double Door Horizontal Type

16

-

-

... More
Supplying and fixing following ways surface / recess mounting Vertical type 415 Volts TPN MCB distribution board, of sheet steel dust protected duly power painted inclusive of 200 Amps tinned copper bus bar common, neutral link, earth bar, din bar, for mounting MCB's (But without MCB's and incomer) as required. ( Note:- Vertical Type MCB TP DB is normally used where 3phase outlets are required.

-

-

-

... More
8 Way (4+18), Double Door Vertical Type

12

-

-

... More
12 Way (4+24), Double Door Vertical Type

6

-

-

... More
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.

-

-

-

... More
6 / 32 Amp Single Pole

760

-

-

... More
40 Amp DP

8

-

-

... More
50/63 Amp DP

16

-

-

... More
6/32 Amp TPN

12

-

-

... More
40 Amp TPN

12

-

-

... More
50/63 Amp TPN

25

-

-

... More
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.

60

-

-

... More
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.

-

-

-

... More
16/25 Amps

36

-

-

... More
40 Amps

40

-

-

... More
63 Amps

91

-

-

... More
Providing and fixing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird

10

-

-

... More
Providing and fixing H.T. danger Notice plate of 250mm x 200 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird

2

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. (Approved make: Erico / Cape Electric / JMV / OBO )

57

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. (Approved make : Erico / Cape Electric / JMV / OBO )

15

-

-

... More
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.

270

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required

720

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

300

-

-

... More
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.

120

-

-

... More
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required(2*rate)

200

-

-

... More
Providing and fixing of lighting conductor finial made of 25 mm dia 300 mm long, GI tube having single prong at top with 85 mm dia 6mm thick G.I Base plate including hole etc. as required

31

-

-

... More
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. (for Horizental Run)

600

-

-

... More
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. (for Vertical Run)

580

-

-

... More
Providing and fixing testing Jointing made of 20mmx 3mm thick G.I Strip 125 mm Long. With 4 nos of G.I bolts. Nuts chuck nuts and spring washers etc. as required

29

-

-

... More
Providing and Laying G.I tape 32mm x 6mm from earth electrode directoly in ground as required.

290

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

30

-

-

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

20

-

-

... More
INSPECTION CHAMBER:

-

-

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :

-

-

-

... More
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets.

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

12300

-

-

... More
2 run of cable

2200

-

-

... More
3 run of cable

775

-

-

... More
Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I).

-

-

-

... More
(Approved Make : Finolex / Polycab / Skytone / RR Kable / Havells )

-

-

-

... More
3.5 core, 300 sq.mm.

550

-

-

... More
3.5 core, 240 sq.mm.

20

-

-

... More
3.5 core, 185 sq.mm.

550

-

-

... More
3.5 core, 150 sq.mm.

95

-

-

... More
3.5 core, 120 sq.mm.

20

-

-

... More
3.5 core, 95 sq.mm.

30

-

-

... More
3.5 core, 70 sq.mm.

610

-

-

... More
3.5 core, 50 sq.mm.

405

-

-

... More
3.5 core, 35 sq.mm.

225

-

-

... More
4 core, 16 sq.mm.

1825

-

-

... More
4 core, 10 sq.mm.

30

-

-

... More
4 core, 6 sq.mm.

800

-

-

... More
2 core, 16 sq.mm.

50

-

-

... More
2 core, 10 sq.mm.

80

-

-

... More
2 core, 6 sq.mm.

300

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Upto 35 sq. mm

300

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

50

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

50

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

30

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Upto 35 sq. mm

3010

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

1045

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

665

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

570

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with cable tie)

100

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)

60

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)

50

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)

550

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (Approved make : Siemens / Comet / Grippwel / Peeco / Dowells )

-

-

-

... More
2 x 6 sq. mm (19mm)

10

-

-

... More
2 X 10 sq. mm (19mm)

8

-

-

... More
2 X 16 sq. mm (22mm)

2

-

-

... More
3½ X 35 sq. mm (32mm)

8

-

-

... More
3½ X 50 sq. mm (35mm)

14

-

-

... More
3½ X 70 sq. mm (38mm)

18

-

-

... More
3½ X 95 sq. mm (45mm)

2

-

-

... More
3½ X 120 sq. mm (50mm)

2

-

-

... More
3½ X 150 sq. mm (50mm)

4

-

-

... More
3½ X 185 sq. mm (57mm)

16

-

-

... More
3½ X 240 sq. mm (62mm)

2

-

-

... More
3½ X 300 sq. mm (70mm)

22

-

-

... More
4 X 10 sq. mm (25mm) including 4x6 sq.mm

32

-

-

... More
4 X 16 sq. mm (28mm)

92

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (Approved make : Pilco / BEC / MEM )

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

225

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

200

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

160

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

80

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

60

-

-

... More
750 mm width X 62.5 mm depth X 2.0 mm thickness

40

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

10

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

8

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

6

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

4

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
750 mm width X 62.5 mm depth X 2.0 mm thickness

2

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required (Approved make : Pilco / Profab / BEC / MEM )

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

2

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

6

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

10

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

8

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
750 mm width X 62.5 mm depth X 2.0 mm thickness

6

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. (Approved make : Pilco / Profab / BEC / MEM )

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

6

-

-

... More
750 mm width X 62.5 mm depth X 2 mm thickness

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (Approved make : Pilco / Profab / BEC / MEM )

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

6

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

8

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

4

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

4

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
750 mm width X 62.5 mm depth X 2 mm thickness

2

-

-

... More
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required (Approved make : Application control / SPC Electrotech / AR engineering / Amit Engineering)

-

-

-

... More
125 A 15kA SC for 1 sec (including 100A & 63 A )

4

-

-

... More
200 A 25kA SC for 1 sec

1

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes cubicle panel, making connections, etc. as required. (Approved make : ABB / Schneider / Legrand / L & T)

-

-

-

... More
125 A, 25 KA,TPMCCB

4

-

-

... More
200 A, 25 KA,TP MCCB

1

-

-

... More
MAIN L.T. PANEL

-

-

-

... More
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel with PLC based load manager, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required. (Approved make : Application Control / SPC Electrotech / AR Engineering / RM Control / Neptune )

-

-

-

... More
All Incoming / bus coupler / Outgoings ACB's shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site. All ACB shall be supplied with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947

-

-

-

... More
(Each Incomming / outgoing MCCB shall have microprocessor release and variable current setting from front, adjustable overcurrent, short circuit & earth fault protection, front extended lockable handle, pad lockable in off position, shrouding on incomer side, termination shall be suitable for aluminium bus bars / cables and as per specification.)

-

-

-

... More
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).

-

-

-

... More
Note - Complete panel have BMS compactible. Manufacturer shall provide all types of ports, Potential free contact, Aux contactor as required for integration with BMS.

-

-

-

... More
INCOMERS from 1 Nos. 1000 KVA TRANSFORMER

-

-

-

... More
1 nos. 1600 AMP. Four Pole, Electrically operated 3 position motorized (220 V AC) drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based release, over current, earth fault, short circuit, Instantaneous short circuit, closing coil (220 V AC), trip coil (24 V DC), shunt trip release, inbuilt U/V release with LCD / LED display for event history with intruppted current value during fault & measurement of current parameters, 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947.

-

-

-

... More
The ACB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.

-

-

-

... More
1 nos. 32 amp TP MCCB (35 KA) for OLTC (for each transformer incomer)

-

-

-

... More
Protection releases / relays, Metering & Accessories for each Transformer incomers

-

-

-

... More
Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA)

-

-

-

... More
Over Voltage / Under Voltage relay / release (3 phase) with timer.

-

-

-

... More
Backup earth fault relay.

-

-

-

... More
Master trip relay.

-

-

-

... More
Trip Circuit Supervison relay.

-

-

-

... More
TNC switch.

-

-

-

... More
Auto manual selector switch.

-

-

-

... More
1 nos. 0-500 volt range digital type voltmeter with selector switch

-

-

-

... More
1 set of 3 CT's of ratio 1600/5A, Class 1.0 accuracy 15 VA burden for metering.

-

-

-

... More
1 set of 3 CT's of ratio 1600/5A, Class 1.0 accuracy 15 VA burden for APFCR.

-

-

-

... More
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.

-

-

-

... More
1 no. CT's of ratio 1600/5A, Class 5P20 for protection.

-

-

-

... More
1 no. 0-1600 Amp range digital type ammeter with selector switch.

-

-

-

... More
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.

-

-

-

... More
Power factor meter.

-

-

-

... More
Frequency meter.

-

-

-

... More
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.

-

-

-

... More
INCOMERS from 2Nos. 500 KVA DG sets

-

-

-

... More
1 nos. 800 AMP. Four Pole, Electrically operated 3 position motorized drawout type Air Circuit Breaker, with all inbuilt protections, with microprocessor based releases/relays, over current, earth fault, short circuit, Instantaneous short circuit, shunt trip release, closing coil (220 V AC), trip coil (24 V DC), inbuilt U/V release with LCD / LED display for event history & measurement of current parameters with intruppted current value during fault , 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947.

-

-

-

... More
Protection releases / relays, Metering & Accessories for each D G set incomers

-

-

-

... More
Over Voltage / Under Voltage relay / release (3 phase) with timer.

-

-

-

... More
IDMT earth fault relay.

-

-

-

... More
Backup earth fault relay.

-

-

-

... More
Master trip relay.

-

-

-

... More
Trip Circuit Supervison relay.

-

-

-

... More
Reverse power relay.

-

-

-

... More
TNC switch.

-

-

-

... More
Auto / manual / test selector switch

-

-

-

... More
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.

-

-

-

... More
0-500 volt range digital type voltmeter with selector switch

-

-

-

... More
1 set - 3 CTs of ratio : 800/5A , Class 1.0 accuracy 15 VA each burden for metering.

-

-

-

... More
1 set - 3 CTs of ratio : 800/5A , Class 5P20 accuracy 20 VA each burden for protection.

-

-

-

... More
0-800 Amp range digital type ammeter with selector switch.

-

-

-

... More
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.

-

-

-

... More
Frequency meter.

-

-

-

... More
Power Factor meter.

-

-

-

... More
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.

-

-

-

... More
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.

-

-

-

... More
12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.

-

-

-

... More
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.

-

-

-

... More
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.

-

-

-

... More
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.

-

-

-

... More
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (500 KVA)

-

-

-

... More
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.

-

-

-

... More
The ACB shall be electrically and mechanically interlocked with the bus coupler and Transformer incomers.

-

-

-

... More
BUSCOUPLER

-

-

-

... More
1 nos 800 AMP. Four Pole, Electrically operated 3 position motorised (220V AC) drawout type ACB's, closing coil (220V AC), trip coil (24V DC), with inbuilt U/V release 50 KA Breaking Capacity with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:13947-2.

-

-

-

... More
Protection releases / relays, Metering & Accessories for Bus Coupler (s)

-

-

-

... More
Trip circuit supervision relay

-

-

-

... More
TNC switch.

-

-

-

... More
Auto / manual selector switch

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.

-

-

-

... More
The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.

-

-

-

... More
BUS BARS

-

-

-

... More
2000 AMP,TPN busbars of aluminium alloy as per SLD.

-

-

-

... More
PLC for load management / automation

-

-

-

... More
Design, manufacturing, testing at works, supply of PLC Based, Autoload Transfer, Autoload Balancing Panel For 2 nos. 500 KVA DG. sets complete as required to acheive the desired functions.

-

-

-

... More
PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies.

-

-

-

... More
PLC shall have with VIEW PANEL

-

-

-

... More
In addition to required hardware and software following components shall also be provided.

-

-

-

... More
Based on the load requirement only required no. of DG sets shall be operated.

-

-

-

... More
Monitoring of DG set safeties (mechanical as well as electrical).

-

-

-

... More
PLC Hardware as required

-

-

-

... More
Auxiliary relays/contactor/metering/protection etc as required

-

-

-

... More
230 V AC, UPS of suitable rating

-

-

-

... More
Annunciators as required

-

-

-

... More
One no. Battery charger set consisting of Transformer / Rectifier, DC ammeter, DC voltmeter, Charging rate selector switch, Off/Trickle/boost.

-

-

-

... More
All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable.

-

-

-

... More
OUTGOINGS:

-

-

-

... More
All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT's of accuracy class 1.0

-

-

-

... More
02 Nos. 630 Amp TP Moulded Case Circuit Breaker (35 KA)

-

-

-

... More
05 Nos. 315 Amp TP Moulded Case Circuit Breaker (35 KA)

-

-

-

... More
03 Nos. 250 Amp TP Moulded Case Circuit Breaker (35 KA)

-

-

-

... More
01 Nos. 200 Amp TP Moulded Case Circuit Breaker (35 KA)

-

-

-

... More
09 No. 160 Amp TP Moulded Case Circuit Breaker (35 KA)

-

-

-

... More
09 Nos. 125 Amp TP Moulded Case Circuit Breaker (35 KA)

-

-

-

... More
02 No. 100 Amp TP Moulded Case Circuit Breaker (35 KA)

-

-

-

... More
CAPACITOR BANK PANEL (300 KVAR - 1 SET) (PART OF MAIN L.T. PANEL)

-

-

-

... More
INCOMING

-

-

-

... More
1 Nos. 0 to 500 Volt digital voltmeter with Voltmeter Selector Switch & Protective SP MCB (96mm square) (one for each Incoming Breaker).

-

-

-

... More
1 No. 0 to 600 Amp digital ammeter (96mm square) with CT's.

-

-

-

... More
1 Sets of phase indicating lights (RYB) with protection SP MCB's (one set for each incoming breaker).

-

-

-

... More
1 Sets breaker 'ON' & 'OFF' indicating lamp with protection MCB's (one set for each incoming breaker).

-

-

-

... More
11 Step Automatic Power Factor Correction relay (APFC relay).

-

-

-

... More
BUSBARS

-

-

-

... More
500 Amp TPN busbars of aluminium alloy as per SLD.

-

-

-

... More
OUTGOING

-

-

-

... More
4 nos. of 125 AMPS TPN MCCB (35 KA) and 140 amps AC3 duty contactor with 25 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
3 nos. of 63 AMPS TPN MCCB (35 KA) and 80 amps AC3 duty contactor with 25 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
2 nos. of 32 AMPS TPN MCCB (35 KA) and 40 amps AC3 duty contactor with 10 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
1 no. of 16 AMPS TPN MCCB (35 KA) and 20 amps AC3 duty contactor with 5 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank,, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
11 sets of push button stations Red and Green for manual operation of capacitor units with auto/manual selector switches.

-

-

-

... More
1 No. Toggle switch for changing automatic to manual operation of capacitor units.

-

-

-

... More
1 No. Power factor meter.

-

-

-

... More
Main L.T. Panel cum capacitor panel Described as Above.

1

-

-

... More
DISTRIBUTION PANEL

-

-

-

... More
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust and vermin proof Floor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet complete with following equipments, including digital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the incomming and outgoing MCCB shall have 35 KA Ics.The incoming MCCB shall be microprocessor based with O/L & S/C and E/F protection and all Outgoings up to 250A MCCB's may be thermo-magnetic based O/L & S/C protection. All outgoing MCB's shall be C type with 10 KA breaking capacity.

-

-

-

... More
L+P PANEL-01 TO 04 ( GROUND TO THIRD FLOOR)

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 125 Amp FP MCCB (35 KA)

-

-

-

... More
1 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
5 Nos. 25 Amp FP MCB (10 KA)

-

-

-

... More
6 Nos. 32 Amp FP MCB (10 KA)

-

-

-

... More
8 Nos. 63 Amp FP MCB (10 KA)

-

-

-

... More
Panel described as above

4

-

-

... More
UPS O/G PANEL (GROUND FLOOR)

-

-

-

... More
INCOMING

-

-

-

... More
3 No. 125 Amp FP MCCB (35 KA)

-

-

-

... More
3 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
3 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
3 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
300 Amp FP copper busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
7 Nos. 100 Amp FP MCCB (25 KA)

-

-

-

... More
Panel described as above

1

-

-

... More
UPS PANEL-01 TO 04 ( GROUND TO THIRD FLOOR)

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 100 Amp FP MCCB (25 KA)

-

-

-

... More
1 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
06 Nos. 63 Amp DP MCB (10 KA)

-

-

-

... More
08 Nos. 40 Amp FP MCB (10 KA)

-

-

-

... More
02 Nos. 63 Amp FP MCB (10 KA)

-

-

-

... More
Panel described as above

4

-

-

... More
PRESSURIZATION PANEL

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 160 Amp FP MCCB (35 KA)

-

-

-

... More
1 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
15 Nos. 40Amp FP MCB (10 KA).

-

-

-

... More
Panel described as above

1

-

-

... More
KITCHEN PANEL

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 250 Amp FP MCCB (35 KA)

-

-

-

... More
1 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
300 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
08 Nos.63 Amp FP MCB (10 KA).

-

-

-

... More
06 Nos.40 Amp FP MCB (10 KA).

-

-

-

... More
08 Nos.25 Amp FP MCB (10 KA).

-

-

-

... More
16 Nos.63 Amp DP MCB (10 KA).

-

-

-

... More
12 Nos.40 Amp DP MCB (10 KA).

-

-

-

... More
Panel described as above

1

-

-

... More
CSSD PANEL

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 250 Amp FP MCCB (25 KA)

-

-

-

... More
1 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUS BAR

-

-

-

... More
250 Amp TPN aluminium busbar.

-

-

-

... More
OUTGOING

-

-

-

... More
09 Nos.63 Amp FP MCB (10 KA).

-

-

-

... More
06 Nos.63 Amp FP MCB (10 KA).

-

-

-

... More
Panel described as above

1

-

-

... More
OT ISOLATION PANEL

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 63 Amp DP ELCB, 30mA.

-

-

-

... More
1 No. 10 KVA, 230V AC medical grade Isolation Transformer.

-

-

-

... More
1 No. 63 Amp DP Miniature Circuit Breaker. (10 KA)

-

-

-

... More
1 No. Sensor and LIM, 0-10mA.

-

-

-

... More
BUS BARS

-

-

-

... More
100 Amp TPN copper busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
16 No. 6-25 Amp SP Miniature Circuit Breaker. (10 KA)

-

-

-

... More
OT Isolation Panel described as above

2

-

-

... More
LIFT PANEL-1 ( TERRACE FLOOR )

-

-

-

... More
INCOMING

-

-

-

... More
2 No. 160 Amp FP MCCB (35 KA)

-

-

-

... More
1 No Fixed type Automatic transfer switch 160 Amp rating in open frame with  live to live transfer time  150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.

-

-

-

... More
1 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
2 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
2 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
5 Nos. 63Amp FP RCCB (300 mA).

-

-

-

... More
6 Nos. 40Amp DP MCB (10 KA).

-

-

-

... More
Panel described as above

1

-

-

... More
AC PANEL OUT DOOR TYPE ( TERRACE FLOOR )

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 315 Amp FP MCCB (35 KA)

-

-

-

... More
1 No.AVF Meter with inbuilt selector switch.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
400 Amp FP aluminium busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
10 Nos. 63 Amp FP RCCB (300 mA)

-

-

-

... More
Panel described as above

1

-

-

... More
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)

-

-

-

... More
Design, Manufacturing, Supply, installation, Testing & Commissioning of Outdoor Type Panel with Front & Back double door, Top canopy, Mounting on Floor M.S. Stand etc totally enclosed free standing type water, moisture, dust and vermin proof Sub Distribution Board made out of 2.0 mm thick CRCA sheet complete with following equipments, including ammeter, ammeter selector switch, voltmeter, voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires/ cable, interconnection, painting etc as required.

-

-

-

... More
INCOMING

-

-

-

... More
1 No 100 Amp FP Moulded Case Circuit Breaker (35 KA) with 63 Amp 4 Pole Contactor & Timer.

-

-

-

... More
1 No. Digital AVF Meter with inbuilt selector switch and CT' & SP MCB.

-

-

-

... More
1 Set of phase indicating lamps.

-

-

-

... More
1 Set of ON/OFF indicating lamps with SP MCB.

-

-

-

... More
BUS BARS

-

-

-

... More
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.

-

-

-

... More
OUTGOING

-

-

-

... More
10 Nos. 25 Amp DP MCB (10 KA)

-

-

-

... More
03 Nos. 40 Amp DP MCB (10 KA)

-

-

-

... More
Panel described as above

1

-

-

... More
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray.

-

-

-

... More
1C x 50 sq.mm PVC Insulated cu wire including termination etc.

240

-

-

... More
1C x 16 sq.mm PVC Insulated cu wire including termination etc.

100

-

-

... More
Supply, erection, testing and commissioning of following sizes of T V splitter of aluminium die cast body in suitable size of G.I. Box.4 way

6

-

-

... More
Supply, erection, testing and commissioning of following co-axial cable in existing conduit. RG-11

100

-

-

... More
Supply & installation of 32 Amp 3 phase, 415 volt, 50 Hz water tight (IP-55) socket outlet with interlocking switch complete with all fixing accessories.

2

-

-

... More
Supply & installation of 32 Amp single phase 240 Volt, 50 Hz, water tight (IP-55) socket outlet with interlocking switch complete with all the fixing accessories as below.

2

-

-

... More
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. (Approved make : Pilco / Profab / BEC / MEM )

-

-

-

... More
100 mm wide x 40 mm deep.

300

-

-

... More
200 mm wide x 40 mm deep.

240

-

-

... More
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. (Approved make : Pilco / Profab / BEC / MEM )

-

-

-

... More
150 mm wide x 50 mm deep.

30

-

-

... More
250 mm wide x 50 mm deep.

24

-

-

... More
Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mm x 6mm copper strip) front door with glass as complete as required.

2

-

-

... More
FIRE ALARM SYSTEM (ADDRESSABLE TYPE) AND PA SYSTEM

-

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.(Approved Makes: Notifie by Honeywell, Bosch, Advance)

-

-

-

... More
Ten Loop Panel.

1

-

-

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.(Approved Makes: Notifie by Honeywell, Bosch, Advance)

1

-

-

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required.(Approved Makes: Notifie by Honeywell, Bosch, Advance)

599

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)

6

-

-

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)

18

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)

10

-

-

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing) (Approved Makes: Notifie by Honeywell, Bosch, Advance)

18

-

-

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)

406

-

-

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)

35

-

-

... More
Supply, installation, testing and commissioning of addressable monitor module complete as per specification. (Approved Makes: Notifie by Honeywell, Bosch, Advance)

12

-

-

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (Approved Make :Universal(Satna) / CCI / Nicco / Finolex / Polycab / Skytone / RR )

6650

-

-

... More
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)

1

-

-

... More
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)

1

-

-

... More
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)

136

-

-

... More
Supplying, installation, testing & commissioning of digital audio amplifier 480 Watt, supply complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)

2

-

-

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.

-

-

-

... More
Speaker cable Single pair, 2-core, 1.5 sqmm (Approved Make : Finolex / Polycab / Skytone / RR Kable / Havells )

2040

-

-

... More
SUPPLY & INSTALLATION OF LIGHT FIXTURES & FANS

-

-

-

... More
SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)

-

-

-

... More
12W LED Round Down Light (Recess )

185

-

-

... More
15 / 16 W LED Round Down Light (Recess )

21

-

-

... More
18 /20 W LED Round Down Light (Surface)

60

-

-

... More
18 /20 W LED Round Down Light (Recess)

718

-

-

... More
2' x 2' LED Panel Light (Recess)

451

-

-

... More
Bulk Head fitting with 9/10Watt LED.

15

-

-

... More
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required.

-

-

-

... More
10/12 W LED Tube Light

20

-

-

... More
20/22 W LED Tube Light

110

-

-

... More
30 W COB based round LED Light with multiple beam angles (36 Degree)

10

-

-

... More
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. (Approved Make :- Usha /Crompton / Havells / Bajaj) .

50

-

-

... More
Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required.(Approved Make :- Usha/Crompton / Havells / Bajaj) .

-

-

-

... More
1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan

250

-

-

... More
UPS SYSTEM

-

-

-

... More
Supply, fitting, fixing, testing and installation of 50 KVA, ON Line UPS three phase input and three phase out put power system of in put voltage range 360V/380/V/400V/485V AC , Frequency range 40 HZ to 60 Hz, +/- 10% and out put voltage range 415V +/-1%, AC frequency range, 50Hz, +/-1% poower factor 0,8/3.1, Harmonic distrortion - 2% THD (Linear Load): 5% THD (Non- Liniear Load) along with required Batteries, Battery Stand, UPS Box Battery Lead etc as required. (Approved Make- APC / SOCOMEC / NUMERIC/ ETON )

-

-

-

... More
UPS shall carry design output at 40 deg.

-

-

-

... More
Shall have soft start and hold of for incoming supply.

-

-

-

... More
Invertor capability to supply 150% load for 5 sec.

-

-

-

... More
SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transforme.

-

-

-

... More
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.

-

-

-

... More
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.

-

-

-

... More
Suitable size of copper cable between UPS and battery bank shall be provided

-

-

-

... More
UPS shall be compatible for 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.

-

-

-

... More
SITC of MS Battery Rack suitable for 40 to 50 UPS Battery Installation.

-

-

-

... More
SITC of 35 nos. 120 AH Flat type Sealed Maitanace Free (SMF) Battery with 24 months replacement warranty. IS:1652:1991. (VAH Required minimum 50400 for 50 KVA UPS (120AH x 35 Nos. x 12V = 50400 VAH)

-

-

-

... More
Total cost of 1 Set 50 KVA UPS, Batteries & Accessories (A+B+C)

2

-

-

... More
DATA, TELEPHONE SYSTEM INCLUDING ACTIVE COMPONENTS

-

-

-

... More
(Approved Make :- Alcatel / Legrand / Cisco / Aruba) .

-

-

-

... More
Supply, Installation, Testing & Commissioning of Cat 6, 24 Port Patch Panel

2

-

-

... More
Supply, Installation, Testing & Commissioning of Cat 6, 48 Port Patch Panel

7

-

-

... More
Supply, Installation, Testing and Comissioning of Cat 6 patch cord 3 feet for rack and user end termination - 1Mtr

229

-

-

... More
Supply, Installation, Testing and Comissioning of Cat 6 patch cord 7 feet for rack and user end termination - 2Mtr

109

-

-

... More
Supply, Installation, Testing, Commissioning of Cat 6, Information Outlet (I/O) including G.I. Box and modular cover plate.

338

-

-

... More
Supply, Installation, Testing and Comissioning of 24U floor mounted Rack with accessories.

4

-

-

... More
Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 48 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE.

7

-

-

... More
Supply, Installation, Testing & Commissioning of EPABX SYSTEM Configuration as Below:- Analog Trunk Line 6 Nos. Digital Line 2 Nos Analog Extensions 120 Nos.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Digital Phone for Operator Console

2

-

-

... More
Supply, Installation, Testing & Commissioning of Type Analog Phone with speaker phone, .

107

-

-

... More
Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable.

1

-

-

... More
IP CCTV SYSTEM

-

-

-

... More
Supplying, installation, testing & commissioning of 1080p HD Indoor IP Dome camera with1/3-inch CMOS, Sensor pixels 1920 x 1080, Sensitivity-0.04 lx (color) , Dynamic range 75 dB Wide Dynamic Range (WDR), True day/night, Automatic Electronic Shutter, Video compression H.264 ; M-JPEG, White balance, BLC, H.264 quad-streaming, Motion/tamper/audio detection, Privacy Mask, Lens 3.6 mm lens, 3-axis adjustment (pan/tilt/ rotation), ONVIF Profile S, CE Certified. (Approved Make: Honeywell / Tyco / Uniview / Bosch).

33

-

-

... More
Supplying, installation, testing & commissioning of 5MP 30 fps HD indoor / outdoor IR IP bullet camera with 1/3‑inch CMOS, Sensor pixels 2612 (H) x 1980(V), Sensitivity-0.24 lx (color) 0.04 lx (mono) ,IR range 30 mtrs, Dynamic range 70 db, True day/night, Automatic Electronic Shutter, Video compression H.264 MP ; M-JPEG, White balance, BLC, Analog video output, Lens (zoom / focus) 3.6 mm lens, Two-way, full duplex Audio, Audio compression AAC, G.711, L16 , ONVIF Profile S, CE Certified. (Approved Make: Honeywell / Tyco / Uniview / Bosch).

8

-

-

... More
Supply installation and commission of pann tilt zoom camera with 360 deg pan and 90 deg tilt with 36 X Zoom having maximum resolution of Max. 1920 × 1080 @30fps,true day night camera with 130 m IR range , optional, fine picture at Ultra-low light,supports compression format H.265, H.265+, H.264+, H.264, 3D Digital Noise Reduction support. (Approved Make: Honeywell / Tyco / Uniview / Bosch).

1

-

-

... More
SITC of IP network recoder with following feature Processor - Dual-core embedded processor . Two-way Talk - 1 channel Input, 1 channel Output, RCA,Video Output - 1 HDMI, 1 VGA ,  IP Camera Input - 8/16/32 Channel IP ,  Compression - H.264+/H.264/MJPEG,Video Resolution - 2560 × 1920, 2048 × 1536, 1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768 , Hard Disk - 4 SATA Ports, up to 8TB ,Motion Detection - MD Zones: 396 (22 × 18),Recording Mode - Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Camera Blank, Video Loss), Alarm, Stop, Backup Mode - USB Device /Network , Interface Ports - 1 HDMI, 1 VGA, 2 USB(1 USB 2.0 , 1 USB 3.0 ), 1 RS485, 1 RS232, 1 RJ45. (Approved Make: Honeywell / Tyco / Uniview / Bosch).

2

-

-

... More
Supply, Installation, Testing and commissioning of Managable 24 port Switch with Power on Ethernet (PoE) enabled, 10/100, RJ45 Access ports with PoE complete as required. (Approved Make : D- Link, CISCO / NETGEAR )

2

-

-

... More
Supply, installation, testing and commissioning of of 6 TB HDD all accessories complete as required.(Approved Make- WD / Samsung)

2

-

-

... More
Supply installation and commissioning of 48 inch LED monitor for disply of camera. (Approved Make : Samsung / sony )

2

-

-

... More
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM

-

-

-

... More
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 325 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.

10

-

-

... More
AUTOMATIC FIRE DETECTION GAS SUPPRESSION SYSTEM IN PANELS

-

-

-

... More
Supply, fixing, testing and commissioning of Automatic Linear pneumatic Tube Detection based Novec 1230 System for Electrical Panels (consisting of the following components.

-

-

-

... More
Approved Makes - Firemech / Nohmi / Ceasefire / Tyco / Firetrex)

-

-

-

... More
6 KG Novec 1230, DLP Assembly with automatic valve mounted on approved cylinder, push in connector for tube, Novec 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.

1

-

-

... More
2 KG Novec 1230, DLP Assembly with automatic valve mounted on approved cylinder, push in connector for tube, Novec 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.

1

-

-

... More
Linear pneumatic heat Detection Tube with all necessary fittings & supports

200

-

-

... More
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System (Supply to be provide by the end client at 220 Volt AC).

2

-

-

... More
DG SET & SUBSTATION WORK

-

-

-

... More
DIESEL GENERATING SET

-

-

-

... More
Supply, Installation testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.

-

-

-

... More
Approved Makes - Cummins / Sterling / MTU Caterpillar / Kirlosker

-

-

-

... More
Diesel Engine -

-

-

-

... More
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.

-

-

-

... More
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :

-

-

-

... More
Start stop switch with key

-

-

-

... More
Water temperature indication

-

-

-

... More
Lubrication oil pressure indication.

-

-

-

... More
Lubrication oil temperature indication.

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over speed indication

-

-

-

... More
Low Lube oil trip indication

-

-

-

... More
Engine hours indication

-

-

-

... More
Alternator -

-

-

-

... More
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination / cable termination as required.

-

-

-

... More
Approved Makes - Stamford / Leroy Somer / Greaves / Marathon

-

-

-

... More
Note : - Alternator should have with all other accessories as per specified in Technical specfications.

-

-

-

... More
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.

-

-

-

... More
Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.

-

-

-

... More
Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.

-

-

-

... More
Exhaust Silencer - Exhaust manifold with residential silencer.

-

-

-

... More
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.

-

-

-

... More
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.

-

-

-

... More
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.

-

-

-

... More
500 KVA

2

-

-

... More
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval)

-

-

-

... More
200 mm dia (wall thickness - 4.85 mm)

60

-

-

... More
Supply & fixing of SS Bellow of following diameter 200 mm dia

4

-

-

... More
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.

4500

-

-

... More
11 KV HT VCB FOUR BREAKER PANEL BOARD (INDOOR TYPE)

-

-

-

... More
Supplying, Installation, Testing & Commissioning of indoor type floor mounted metal clad, 11 KV VCB panel with 3 nos VCBs, totally inclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 630 Amp capacity, breaker featured with mechanical ON/OFF indicator with hand trip device.

-

-

-

... More
Approved Makes - ABB / Siemens / Schneider / Tricolite / Ambit / ADLEC /

-

-

-

... More
Spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories i/c connections for 3C x 300 sq.mm. XLPE 11 KV cable (cable entry from bottom), end termination with heat shrinkable jointing material etc. as required. (Note - Cost of end termination not included in this item).

-

-

-

... More
a) 1 No, 630 Amp, VCB.

-

-

-

... More
b) 1 No.- 11 KV / 110 Volt PT class 0.5 accuracy and 100 VA burden with 1 No. voltmeter (0-12 KV), digital type, selector switch for voltmeter and protection MCB for HT Metering up to 12 KV on incommer.

-

-

-

... More
c) 1 No.- (0 - 150 A) dual scale Ammeter, digital type, selector switch for ammeters.

-

-

-

... More
d) 1 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.

-

-

-

... More
e) 1 No - set of dual core dual ratio 3 CTs 100/5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.

-

-

-

... More
f) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.

-

-

-

... More
g) 1 No. hooter with hooter acceptance and reset push button.

-

-

-

... More
h) 1 No - Red, Yellow & Blue for phase indication.

-

-

-

... More
i) 1 No - Amber for Trip indication.

-

-

-

... More
j) 1 No - Red `ON' Green `OFF'indication.

-

-

-

... More
k) 1 No - Spring charge indication.

-

-

-

... More
l) 1 No - Auto trip indication.

-

-

-

... More
m) 1 No. hooter with hooter acceptance and reset push button.

-

-

-

... More
n) 1 No. master trip relay. ( Electromechanical Type )

-

-

-

... More
o) 1 No.Trip ckt supervision relay. (Electromechanical Type )

-

-

-

... More
a) Outgoing - 2 No, 630 Amp, VCB.

-

-

-

... More
b) 2 No.- (0 - 100 Amp) dual scale Ammeter, digital type, selector switch for ammeters.

-

-

-

... More
c) 2 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.

-

-

-

... More
d) 2 No - set of dual core dual ratio 3 CTs 100/5 A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.

-

-

-

... More
e) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.

-

-

-

... More
f) 2 No. hooter with hooter acceptance and reset push button.

-

-

-

... More
g) 2 No - Red, Yellow & Blue for phase indication.

-

-

-

... More
h) 2 No - Amber for Trip indication.

-

-

-

... More
i) 2 No - Red `ON' Green `OFF'indication.

-

-

-

... More
j) 2 No - Spring charge indication.

-

-

-

... More
k) 2 No - Auto trip indication.

-

-

-

... More
l) 2 No. hooter with hooter acceptance and reset push button.

-

-

-

... More
m) 2 No. master trip relay. ( Electromechanical Type )

-

-

-

... More
n) 2 No.Trip ckt supervision relay. (Electromechanical Type )

-

-

-

... More
o) 2 No.auxiliary relay for transformer fault.

-

-

-

... More
p) Power pack.

-

-

-

... More
H.T. Panel described as above

1

-

-

... More
TRANSFORMER

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of out door type copper wound transformer continuously rated for 3Ph 50 Hz at full load rating the transformer should have oil immersed winding having vector group DY-11, HT side connected in star with neutral brought out connected to provide separate earthing. The transformer shall have power terminal arrangement bushing / cable end box on HT side and cable end box on LT side. 1000 KVA, 11 KV /0.415 KV, 3 phase, 5.0 % impedance, 50 Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the Transformer. The transformer should have following standard as per amended IS specification and the load * no load losses shall be limited to the values given below or as per IS 2026 and latest IS-1180 or Norms issued by SEB which ever are Lower.

-

-

-

... More
Approved Makes - Crompton / ABB / Schneider / Voltamp / Sudhir Intra / Esennar

-

-

-

... More
Oil Conservator with filling hole with cap and plain oil level gauge.

-

-

-

... More
Silica gel dehydrating breather charged with silica gel.

-

-

-

... More
Oil drain Valve

-

-

-

... More
Oil Filter Valve

-

-

-

... More
Lifting eyes / Hooks

-

-

-

... More
Two earthing Terminals

-

-

-

... More
Diagram and rating plate

-

-

-

... More
Air Vent

-

-

-

... More
Explosion Vent

-

-

-

... More
100 mm dia thermo meter with thermometer pocket

-

-

-

... More
Four bi directional plain roller

-

-

-

... More
Buchholz relay

-

-

-

... More
Resistance Temp detector

-

-

-

... More
Marshalling box

-

-

-

... More
Automatic Voltage Regulator ( AVR)

-

-

-

... More
Remote Tap Changing controller ( RTCC)

-

-

-

... More
Transformer 11000/415 volts with on load Tap changer -15% to +5% in steps of 1.25% with RTCC, AVR and marshalling box and other specification as per BIS Level-2

-

-

-

... More
1000 KVA

1

-

-

... More
11 KV END TERMINATION:

-

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 240 Sqmm, 11KV XLPE

1

-

-

... More
11 KV H.T. CABLE:

-

-

-

... More
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required.3C x 185 Sqmm, 11 KV XLPE

50

-

-

... More
Laying of one number additional PILCA / PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of size exceeding 120 sqmm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.

50

-

-

... More
Supply & Laying of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS.

-

-

-

... More
4 core, 2.5 sq.mm.

30

-

-

... More
10 core, 2.5 sq.mm.

30

-

-

... More
12 core, 2.5 sq.mm.

50

-

-

... More
Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.

20

-

-

... More
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.

5

-

-

... More
Supplying & Placing of First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963 etc as reqd.

2

-

-

... More
Supplying & Installation of Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English) etc. as reqd

2

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
S.I.T.C of Following rating LED Street Lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection ) in existing pole / pipe for supply voltage 100-270 AC 50Hz Luminare shall be confirm to IS :10322 part 5/ section-3 and shall be complete with all nessessary accessories as required. (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)

-

-

-

... More
60W LED Street Light

20

-

-

... More
S.I.T.C of Following rating LED Post Top lamp made in die cast aluminium housing with decorative clear / opel acrylic diffuser on existing pipe including connection with 1.5sq.mm coppwr conductor etc all complete as required. (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)

-

-

-

... More
20/25W LED Post top lamp clear

4

-

-

... More
S.I.T.C of Following rating approved make LED Bollard Fitting with cylindrical shape and inverted cone shape head of height 600 to 850 mm power input -8/9 watt with die cast aluminium housing opel with PC diffuser, IP-65/54 protection, conferming to IS : 10322 part 5 etc all complete as requird. (Excluding Plinth Charge.) (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)

20

-

-

... More
Supplying & installation of 7 mtr. Height Octagonal Hot Dip galvanized pole (BOP. 7030) with top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (without Arm). (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)

20

-

-

... More
1m Single Arm Suitable for 70MM Top

20

-

-

... More
SANITARY INSTALLATIONS

-

-

-

... More
Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification and direction of E/I.

-

-

-

... More
(ii) E.W.C. With 'S' trap

-

-

-

... More
(b)10 lit. Low level PVC Cistern

78

-

-

... More
Supplying fitting and fixing white glazed fire’s clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P.brass waste with C.P.brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/I.

-

-

-

... More
(i) Kitchen sink 600 mm x 450 mm x 250 mm

2

-

-

... More
Providing and fixing white vitreous china laboratory sink with CI brackets , C.P brass chain with rubber plug 40 mm C.P brass waste and 40 mm CP brass trap with necessary C.P brass unions complete including painting of fittings and brackets , cutting and making good the wall wherever required : Size 600x450x200 mm

18

-

-

... More
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe-32mm Dia

20

-

-

... More
White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

96

-

-

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :

-

-

-

... More
Rectangular shape 453x357 mm

16

-

-

... More
Rectangular shape 1500x450 mm

28

-

-

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.

126

-

-

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.

44

-

-

... More
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms

44

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931

44

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore

44

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore

242

-

-

... More
Providing and fixing toilet paper holder : C.P. brass

78

-

-

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth aggregate 6 mm nominal size) as per direction of Engineer-in-Charge Granite Stone of approved shade

10

-

-

... More
Providing & fixing rain water `Khurras' size 450x450 mm required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen. Including Heavy duty CI/MS grating as per drawing complete as required.

22

-

-

... More
INTERNAL DRAINAGE INSTALLATIONS

-

-

-

... More
Providing and fixing cast iron trap of self cleansing design with cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.

-

-

-

... More
100 mm inlet and 100 mm outlet

98

-

-

... More
Sand Cast Iron S & S as per IS:3989

-

-

-

... More
100 mm inlet and 75 mm outlet

1

-

-

... More
Sand Cast Iron S & S as per IS:3989

-

-

-

... More
Providing and fixing soil, waste, vent and rain water pipes

-

-

-

... More
Centrifugally cast (spun) iron S&S pipe

-

-

-

... More
100mm dia cast (spun) iron S&S pipe

1450

-

-

... More
75 mm dia cast (spun) iron S&S pipe

410

-

-

... More
Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc.

-

-

-

... More
For 100 mm dia. Pipe

100

-

-

... More
For 75 mm dia. Pipe

45

-

-

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.

-

-

-

... More
100 mm dia

-

-

-

... More
Centrifugally cast (spun) iron pipe S&S

30

-

-

... More
75 mm dia

-

-

-

... More
Centrifugally cast (spun) iron pipe S&S

5

-

-

... More
Providing and fixing plain bend of required degree.

-

-

-

... More
100 mm dia

-

-

-

... More
Sand cast iron S&S as per IS : 3989

22

-

-

... More
75 mm dia

-

-

-

... More
Sand cast iron S&S as per IS : 3989

20

-

-

... More
Providing and fixing heel rest sanitary bend,

-

-

-

... More
100 mm dia.

-

-

-

... More
Centrifugally cast (spun) iron pipe S&S

4

-

-

... More
75 mm dia.

-

-

-

... More
Centrifugally cast (spun) iron pipe S&S

14

-

-

... More
Providing and fixing terminal guard:

-

-

-

... More
100 mm

-

-

-

... More
Sand cast iron S&S as per IS - 3989

16

-

-

... More
75 mm

-

-

-

... More
Sand cast iron S&S as per IS - 3989

6

-

-

... More
Providing and fixing collar.

-

-

-

... More
100 mm

-

-

-

... More
Centrifugally cast (spun) iron pipe S&S

40

-

-

... More
75 mm

-

-

-

... More
Centrifugally cast (spun) iron pipe S&S

18

-

-

... More
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :

-

-

-

... More
100 mm dia cast (spun) iron S&S pipe

1450

-

-

... More
75 mm dia cast (spun) iron S&S pipe

410

-

-

... More
WATER SUPPLY INSTALLATIONS

-

-

-

... More
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work -Exposed on Wall

-

-

-

... More
15 mm nominal outer dia pipes

250

-

-

... More
20 mm nominal outer dia pipes

120

-

-

... More
25 mm nominal outer dia pipes

140

-

-

... More
32 mm nominal outer dia pipes

280

-

-

... More
40 mm nominal outer dia pipes

290

-

-

... More
50 mm nominal outer dia pipes

85

-

-

... More
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc.

-

-

-

... More
15 mm nominal outer dia pipes

385

-

-

... More
20 mm nominal outer dia pipes

230

-

-

... More
25 mm nominal outer dia pipes

120

-

-

... More
32 mm nominal outer dia pipes

50

-

-

... More
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

20

-

-

... More
FIRE FIGHTING WORKS

-

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal

23

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (INTERNAL FIRE FIGHTING)

-

-

-

... More
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

18

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

36

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

36

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
80 nominal bore

5

-

-

... More
100 nominal bore

13

-

-

... More
150 nominal bore

2

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
Note: Threaded joint upto 50mm diameter pipe.

-

-

-

... More
Welded joint above 50mm diameter pipe.

-

-

-

... More
25 mm nominal bore (class C)

1250

-

-

... More
32 mm nominal bore (class C)

360

-

-

... More
40 mm nominal bore (class C)

215

-

-

... More
50 mm nominal bore (class C)

220

-

-

... More
65 mm nominal bore (class C)

200

-

-

... More
80 mm nominal bore (class C)

115

-

-

... More
100 mm nominal bore (class C)

145

-

-

... More
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm

45

-

-

... More
SPRINKLER SYSTEM

-

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :

1

-

-

... More
Providing, fixing, testing & commissioning of 15mm diaquartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :

-

-

-

... More
UPRIGHT Sprinkler

785

-

-

... More
Pendent Sprinkler and up right

785

-

-

... More
side wall sprinkler

90

-

-

... More
FIRE EXTINGUSHER

-

-

-

... More
4.5 kg carbon dioxide extinguisher, IS marked, with high pressure discharge tube, horn, control valve, CCE approved cylinder

75

-

-

... More
6 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers

70

-

-

... More
FIRE BUCKET WITH SAND WITH SET OF 4 PAIR

4

-

-

... More
PUMP

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
1620 lpm at 70 m Head (For Hydrant & Sprinkler System).

2

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.

-

-

-

... More
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
180 lpm at 70 m Head (For Hydrant & Sprinkler System).

1

-

-

... More
Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

-

-

-

... More
WATER SUPPLY EXTERNAL

-

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.

-

-

-

... More
External Work

-

-

-

... More
25mm nominal nominal bore

110

-

-

... More
32mm nominal nominal bore

300

-

-

... More
40mm nominal nominal bore

400

-

-

... More
50mm nominal nominal bore

350

-

-

... More
65 mm nominal nominal bore

400

-

-

... More
Providing & Fixing of Garden hydrant outlet consisting 1 No. 25mm dia. Ball valve,( Brass) for connecting rubber hose, pipes & fittings.

25

-

-

... More
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)

-

-

-

... More
20mm nominal bore

1

-

-

... More
25 mm dia, nominal bore

15

-

-

... More
32 mm dia, nominal bore

3

-

-

... More
40 mm dia, nominal bore

4

-

-

... More
50mm nominal bore

3

-

-

... More
65mm nominal bore

3

-

-

... More
Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. -With F.P.S. bricks

8

-

-

... More
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.(WTP Room Abow the UGT.)

-

-

-

... More
50 mm dia, nominal bore

60

-

-

... More
65 mm dia, nominal bore

65

-

-

... More
80 mm dia, nominal bore

35

-

-

... More
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality

-

-

-

... More
50 mm dia, nominal bore

60

-

-

... More
65 mm dia, nominal bore

65

-

-

... More
80 mm dia, nominal bore

35

-

-

... More
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete.

-

-

-

... More
32 mm dia, nominal bore

14

-

-

... More
40 mm dia, nominal bore

16

-

-

... More
50 mm dia, nominal bore

10

-

-

... More
65 mm dia, nominal bore

8

-

-

... More
Providing & fixing in position precast RCC manhole cover and frame of reqd. shape and approved quality. EHD - 35 Circular shape 560 internal dia.

26

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

28

-

-

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm dia

6

-

-

... More
Providing and fixing cast iron wafer type butterfly valves (PN-10) complete with 2 nos. matching flanges (Table-E),bolts, nuts, 3.0 mm thick insertion neoprene gasket.

-

-

-

... More
40mm dia

5

-

-

... More
50mm dia

5

-

-

... More
65mm dia

8

-

-

... More
80mm dia

4

-

-

... More
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 65mm dia.

3

-

-

... More
Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 65mm nominal bore

1

-

-

... More
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.)

-

-

-

... More
25mm dia pipe, 600mm long with size of 250x250x6 mm MS plate

1

-

-

... More
32mm dia pipe, 600mm long with size of 250x250x6 mm MS plate

2

-

-

... More
40mm dia pipe, 600mm long with size of 300x300x6 mm MS plate

3

-

-

... More
50mm dia pipe, 600mm long with size of 350x350x6 mm MS plate

4

-

-

... More
65mm dia pipe, 600mm long with size of 350x350x6 mm MS plate

4

-

-

... More
100mm dia pipe, 600mm long with size of 400x400x6 mm MS plate

4

-

-

... More
150mm dia pipe, 600mm long with size of 450x450x6 mm MS plate

1

-

-

... More
200mm dia pipe, 600mm long with 6 mm MS plate of size 600mm dia

2

-

-

... More
Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design.

-

-

-

... More
25 OD mm.

375

-

-

... More
32 OD mm.

260

-

-

... More
40 OD mm

265

-

-

... More
50 OD mm

210

-

-

... More
63 OD mm

60

-

-

... More
RO SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning built with Drinking Water R.O. unit with micron filtration pre-treatment unit, skid mounted R.O. module with pressure pump and pressure tank, drinking water cooler (High quality SS Tank for Storage 80 lts) , complete in all respects. ( Make & Model No. Eureka Forbes Pure Chill RO Storage Cooler cum Purifier or Equivalent)

2

-

-

... More
EXTERNAL SEWERAGE & DRAINAGE INSTALLATIONS UPTO MAIN ROAD FIRST MANHOLE

-

-

-

... More
Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. All kinds of soil (ii) For classification of soil item-B

35

-

-

... More
Providing laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.

-

-

-

... More
150 mm diameter

300

-

-

... More
200 mm diameter

100

-

-

... More
250 mm diameter

45

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipes including bed concrete as per standard design.

-

-

-

... More
150 mm diameter

300

-

-

... More
200 mm diameter

100

-

-

... More
250 mm diameter

45

-

-

... More
Providing and fixing square mouth SW gully trap grade ‘A’ complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. (COVER MIN. 4.5 KG & FRAME MIN.2.7 KG ) 150x100mm size P type With FPS bricks

40

-

-

... More
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.

-

-

-

... More
150 mm dia RCC pipe

300

-

-

... More
250 mm dia RCC pipe

300

-

-

... More
300 mm dia RCC pipe

110

-

-

... More
450mm dia RCC pipe

97

-

-

... More
Providing and laying in position cement concrete of grade excluding the cost of centering and shuttering - all work up to plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded ston aggregate 40 mm nominal size)

20

-

-

... More
Construction brick masonry manhole in cement mortar 1:4 (1cement : 4coarse sand) RCC top slab with 1:2:4 mix 9 with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.

-

-

-

... More
Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5

50

-

-

... More
Extra for depth for manholes Size 90 x 80 cm with FPS bricks designation 7.5

30

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) complete as per design.

200

-

-

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

30

-

-

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter

4

-

-

... More
PUMPS & ALLIED WORKS

-

-

-

... More
Providing, installing, testing and commissining of variable speed (VSPS) hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, dedicated variable frequency drive for each pump, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 90 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects including MS Zinc coated suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required.

-

-

-

... More
The entire Hydropneumatic system shall be factory fitted.

-

-

-

... More
Hyd. System for Domestic Water Supply Pump

-

-

-

... More
Flow rate : 2 lps each

-

-

-

... More
Pumping Head - 70 m

-

-

-

... More
1 Set = 2 Nos. pump (1 working+1 standby)

-

-

-

... More
Approx H.P.- 3 HP or as per manufacturer recommendation.

1

-

-

... More
Location - Abow UGT.

-

-

-

... More
Flow rate : 1.5 lps each

-

-

-

... More
Head : 70 Mts

-

-

-

... More
Required for : Flushing water transfer pump

-

-

-

... More
(1 working + 1 standby)

-

-

-

... More
Location - Abow STP

1

-

-

... More
Supplying, installing, testing and commissioning of SS vertical centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Intermediate chamber along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Pump shall be provided with mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia). The pump shall be suitable for auto/ manual operation. The installation shall be complete with all necessary ancillaries, starter panel / control panel & accessories including base plate complete as required.

-

-

-

... More
Flow rate : 2 lps each

-

-

-

... More
Head : 70 Mts

-

-

-

... More
Required for : Filter feed pump

-

-

-

... More
(1 working + 1 standby)

-

-

-

... More
Location - Abow UGT.

1

-

-

... More
Providing, fixing, testing & commissioning of vertical FRP filter with adequate dirt holding capacity. Fabricated from FRP sheet as per IS-2825 and manufacturer's specifications complete with intitial charge filter media . The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping (PVC 10 Kg) and multiport valve . it is designed on 1.50 m / sec velocity.

-

-

-

... More
WATER TREATMENT PLANT (WTP)

-

-

-

... More
Dual Media Filter For Domestic Water Supply

-

-

-

... More
Capacity- 7200 LPH

-

-

-

... More
Filtration rate- 16000 LPH/Sqm.

-

-

-

... More
Filter dia approx. - 750 MM

-

-

-

... More
Working pressure: 3.0 Kg/sq cm.

-

-

-

... More
Test pressure : 4. 5 Kg/sq cm

1

-

-

... More
Activated Carbon Filter For Domestic Water Supply

-

-

-

... More
Capacity- 2500 LPH

-

-

-

... More
Filtration rate- 16000 LPH/Sqm.

-

-

-

... More
Filter dia approx. - 750 MM

-

-

-

... More
Working pressure: 3.0 Kg/sq cm.

-

-

-

... More
Test pressure : 4. 5 Kg/sq cm

1

-

-

... More
Treated water Pumps- Domestic water OHT Filling

-

-

-

... More
Capacity : 150 LPM

-

-

-

... More
Head : 70 m

-

-

-

... More
App. HP : 3 HP

-

-

-

... More
Motor RPM : 2900

-

-

-

... More
Each set consists of 2 pumps (1Working +1Standby). At any given time, only one pump need operate. Both the pumps must operate alternatively in service.

1

-

-

... More
Providing & fixing butterfly valve (with motorized actuator) of rating PN 1.6, wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095 of the following sizes complete with cast iron hand level companion flanges, bolts, nuts, washers & inserted rubber gaskets, as required and as per enclosed specification, with single phase Electrical Actuator, of 15Nm- 400Nm Torque, made of aluminium alloy (resistant to heat, acid , alkali, corrosion), and weather proof heavy duty motor, with stabilized start speed to effectively avoid water hammering, with waterproofing seal (IP 67) for all housing seals, low noise level, built –in thermal protection complete as per specifications

-

-

-

... More
40 mm nominal bore

1

-

-

... More
50 mm nominal bore

1

-

-

... More
Providing and fixing lever operated gun metal ball valve with SS-316 ball.

-

-

-

... More
40 mm nominal bore

12

-

-

... More
50 mm nominal bore

20

-

-

... More
Supplying, fixing, testing and commissioning of Cast Iron butterfly valve of PN 1.0 rating with SS-316 seat, Shaft SS-316 duly ISI marked complete with SS bolts & nuts, washers, gaskets conforming to IS 13095 of following sizes as required and two matching flanges as per table 'E' etc.

-

-

-

... More
65 mm nominal bore

5

-

-

... More
80 mm nominal bore

3

-

-

... More
100 mm nominal bore

2

-

-

... More
Providing, Installation ,testing and commission of Cast Iron Dual plate (SS-316 Plates) Non Return valve as per technical specification complete with rubber gaskets, SS bolts & nuts, washers etc. as required and two matching flanges as per table 'E' etc.

-

-

-

... More
40 mm nominal bore

6

-

-

... More
50 mm nominal bore

2

-

-

... More
65 mm nominal bore

1

-

-

... More
80 mm nominal bore

2

-

-

... More
Providing and fixing of Cast Iron flanged Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 316, sheet with 3 mm dia. holes with stainless steel flange with rubber gaskets, SS bolts & nuts, washers etc. complete as required.

-

-

-

... More
50 mm nominal bore

1

-

-

... More
65 mm nominal bore

1

-

-

... More
Providing and fixing of Pressure gauge (dial size minimum 6”) weather proof (IP-55) with a scale range from 0 to 10 Kg / cm² including stop cock.

6

-

-

... More
Providing and fixing G.I. suction & delivery headers / pipes for water supply pumps (IS:1239 heavy class) with G.I. Fittings (bends, tees, reducers, plugs, union, flange & blank flanges etc.) and clamps and jointing with Teflon tape or hold tite including chase cutting and making good the walls, floors etc. wherever required. Painting with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved primer coat as directed including surface preparation (Shade as per pipe colour code)

-

-

-

... More
40 mm nominal bore

80

-

-

... More
50 mm nominal bore

100

-

-

... More
65 mm nominal bore

50

-

-

... More
80 mm nominal bore

80

-

-

... More
Providing and fixing double flanged flexicion rubber expansion joint with unit control of standard length of a as per manufacturer specs tested to a pressure of 15 kg/sqcm including rubber gasket, flanges, nuts ,bolts and washers complete as required. 40 mm nominal bore

6

-

-

... More
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts.

-

-

-

... More
All switchboards shall have provision for entry of cables from the top or bottom as required.

-

-

-

... More
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.

-

-

-

... More
Electric Panel For Water Supply Pumps at Water Supply Pump Room

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 63 amps TPN MCCB with the following accessories:

-

-

-

... More
1 No. square flush mounting 0-500 volts scaled voltmeter with three way and OFF switch.

-

-

-

... More
Three phase indicating lights.

-

-

-

... More
Electrolytic high conductivity three phase and neutral tinned copper bus bar rated at 100 amps having a current density of 1 amp per Sqmm suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The neutral bus bar is to be of 100% capacity.

-

-

-

... More
OUTGOING UNITS

-

-

-

... More
6 25/40 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA

-

-

-

... More
Two 63 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA

-

-

-

... More
2 Nos. fully automatic DOL starters with push buttons and ON/OFF indicating lights and overload relays for 1.5 to 7.5 HP pump .

-

-

-

... More
2 Nos. rotary selector switch for selecting mode of operation i.e. auto/manual/off.

-

-

-

... More
2 Nos.cyclic relay for automatic duty changeover of pumps.

-

-

-

... More
2 No. single phase preventors.

-

-

-

... More
2 Nos. square flush mounting 0-30 amps scaled ammeters with three way and OFF selector switch.

-

-

-

... More
Space for 3 Nos. Level Controllers.

-

-

-

... More
Switchgear shall be suitable for the HPS of various motors.

-

-

-

... More
1 Nos. 63 Amp. TPN MCB Spare.

-

-

-

... More
2 Nos. 32/40 Amp. TPN MCB Spare.

-

-

-

... More
The motor control panel shall be prewired with colour coded wires with identification labels complete in all respects as required.

1

-

-

... More
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to probes of required.

-

-

-

... More
Level Controller For Water Supply Pump:

-

-

-

... More
To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.

1

-

-

... More
SEWAGE TREATMENT PLANT 35 KLD

-

-

-

... More
Design, Supplying, installing, testing & commissioning of Sewage Treatment Plant of 35 KLD (excluding excavation, back filling & disposal of surplus earth MS / Civil construction work) for the following duty:

-

-

-

... More
Sewage treatment plant shall include the following items:

-

-

-

... More
a. Screen chambers with SS Screen b. Equalization Tank c. Aerobic & Anoxic tank d. MBBR TANK e. Air Blowers f. MBBR Media g. Recirculation pumps, backpulse pump, permeate pump etc. h. Dewatering system j. Electrical Panel, Cabling (Power & Control), Earthing k. Tertiary Treatment l. Clear Water tank and Flushing Water tank.

-

-

-

... More
INLET SEWAGE CHARACTERSTICS (ASSUMED)

1

-

-

... More
pH - 6.0 – 8.5

-

-

-

... More
BOD5 : 250 - 350 mg/lit

-

-

-

... More
Total Suspended Solids (TSS) : 250 - 450 mg/lit

-

-

-

... More
COD : 500 - 700 mg/lit

-

-

-

... More
Oil / Grease : upto 50 mg/lit

-

-

-

... More
Inflow time : 24 HRS

-

-

-

... More
Peak factor : 3

-

-

-

... More
Temperature : Ambient

-

-

-

... More
Desired Sewage Quality After Treatment

-

-

-

... More
pH : 7 - 8

-

-

-

... More
BOD5 : 10 mg/lit

-

-

-

... More
Total Suspended Solids (TSS) : 10 mg/lit

-

-

-

... More
COD : 50 mg/lit

-

-

-

... More
Oil / Grease : 5 mg/lit

-

-

-

... More
Colour : Colourless

-

-

-

... More
Odor : unobjectionable

-

-

-

... More
E.coli : Nil

-

-

-

... More
NH4-N : 5 mg/lit

-

-

-

... More
N Total : 10 mg/lit

-

-

-

... More
PO4-P : 2 mg/lit

-

-

-

... More
Note: Vendor shall ensure submission of detailed GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.

-

-

-

... More
EFFUENT TREATMENT PLANT 6 KLD

-

-

-

... More
Design, Supplying, installing, testing & commissioning of Effluent Treatment Plant of 6 KLD (excluding excavation, back filling & disposal of surplus earth and Civil construction work) for the following duty:

-

-

-

... More
Effluent from OT Scrubs, blood bank, labs etc. Some solvent/ chemical waste originating typically from hospital complex shall also be discharged into the ETP. Design to take consideration of same.

-

-

-

... More
INLET EFFLUENT CHARACTERSTICS

-

-

-

... More
PH : 5.5 - 9.0

-

-

-

... More
BOD : 250 - 600 mg/l

-

-

-

... More
S. Solids : 200 - 650 Mg/l

-

-

-

... More
COD : 600 - 1200 mg/l

-

-

-

... More
Oil & Grease : 50-140 mg/L

-

-

-

... More
Effluent discharge standard after treatment

-

-

-

... More
pH - 6.0 – 8.5

-

-

-

... More
BOD - Less than 150 Mg/L

-

-

-

... More
S. Solids - Less than or equal to 100 Mg/L

-

-

-

... More
COD - Less than or equal to 300 Mg/L

-

-

-

... More
Oil & Grease - Less than 5 Mg/L

-

-

-

... More
Effluent treatment plant shall include the following items:

1

-

-

... More
Screen Chamber

-

-

-

... More
Equalization tank/sump

-

-

-

... More
Primary Tube Settler

-

-

-

... More
Dosing System

-

-

-

... More
Sludge Holding Tank

-

-

-

... More
UV System

-

-

-

... More
Air Blowers, Pumps & equipment

-

-

-

... More
Piping, valves etc

-

-

-

... More
Clarified Water tank

-

-

-

... More
Electrical Panel & Cabling

-

-

-

... More
Note:

-

-

-

... More
Contractor shall ensure submission of detailed GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.

-

-

-

... More
HVAC WORKS

-

-

-

... More
AIR COOLDED VARIABLE REFRIGERANT VOLUME/FLOW AIR CONDITIONING SYSTEM

-

-

-

... More
Supply, Installation, testing and commissioning of air cooled Variable Refrigerant Volume/Flow modular type air-conditioning system Invertor Controlled with step less modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications and having following items: Refrigerant to be used shall be - R - 410 A.

-

-

-

... More
OUTDOOR UNIT

-

-

-

... More
Supply, Installation, testing and commissioning of Both Cooling & Heating Modular type outdoor units suitable to operate at 415 ± 10 % volt, 50 Hz, 3 phase AC supply and suitable for cooling application by using 100 % inverter driven capacity control compressors (Hermetically sealed scroll/Twin Rotary type) with stepless modulation complete with special acryl precoated heat exchanger, low noise condenser fan , auto check function for connection error in display panel, auto address setting as per specifications. The COP at AHRI conditions shall not be less than 4.2 . The units shall be complete with necessary mounting frames and capacity as mentioned below and as per specification.

-

-

-

... More
The cost should include the following :

-

-

-

... More
Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard.

-

-

-

... More
Necessary corrosive treatment of copper coil of the ODU with Aluminum hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulfur and other chemical contaminants present in the air. The coating should be done in the presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.

-

-

-

... More
Note : The ODU provided with cowl duct for exhaust air should have minimum 5 mm ESP. GI wire mesh (minimum 16 SWG thickness) type bird screen with framing at the Mouth of exhaust air Cowl duct of Outdoor Units.

-

-

-

... More
ODU Units Mounted on MS Frame/Masonry Pedestal with required anti-vibration mounting.

-

-

-

... More
14 HP (1x14 HP)

1

-

-

... More
24 HP (2x12 HP)

3

-

-

... More
28 HP (2x14HP)

1

-

-

... More
30 HP (1x16HP+1x14HP)

1

-

-

... More
34 HP (1x18HP+1x16HP)

1

-

-

... More
36 HP (2x18HP)

1

-

-

... More
42 HP (3x14HP)

2

-

-

... More
Indoor VRV/VRF Units

-

-

-

... More
Supply, Installation, testing & commissioning of metallic body indoor (Hi-Wall, Cassette & Ducted) Units of following minimum capacity suitable to operate at 230+/-10% volt, 50 HZ, 1 phase power supply and having multispeed motor, blower, coil section with DX coil, outer cabinet, drain pan, drain pump, drain water lift-up mechanism, insulation, pipe connections, fittings & required cable to connect indoor unit to MCB etc. complete in all respect and as per specification.

-

-

-

... More
Indoor Units powder coated MS Hanging arrangement/wall Brackets with required anti-vibration mounting.

-

-

-

... More
CEILING SUSPENDED DUCTED TYPE UNITS

-

-

-

... More
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
Indoor Units powder coated MS Hanging arrangement/wall Brackets/Spring Isolators with required anti-vibration mounting and Fire Rated Flexible Connection.

-

-

-

... More
Mid Static Ductable units (minimum 50 pascal external static pressure)

-

-

-

... More
1.1 TR (375 CFM)

22

-

-

... More
1.3 TR (450 CFM)

6

-

-

... More
1.6 TR (600 CFM)

18

-

-

... More
Mid Static Ductable units (minimum 100 pascal external static pressure)

-

-

-

... More
2.1 TR (725 CFM)

13

-

-

... More
2.6 TR (875 CFM)

2

-

-

... More
3.3 TR (1050 CFM)

1

-

-

... More
High Static Ductable units (minimum 150 pascal external static pressure)

-

-

-

... More
4.0 TR (1400 CFM)

1

-

-

... More
4.6 TR (1650 CFM)

6

-

-

... More
5.5 TR (2050 CFM)

2

-

-

... More
8.0 TR (2550 CFM)

2

-

-

... More
CEILING SUSPENDED TREATED FRESH AIR UNITS

-

-

-

... More
Supplying, installing, testing and commissioning of Ceiling Suspended Treated Fresh air Units each complete with coil, filter, etc. Air conditioners with evaporating unit comprising of cooling coil, blower with motor and 220 volt, 1 phase, 50 Hz, AC supply all as per specifications. The rate will also include entire drain pipes and nothing extra shall be payable.

-

-

-

... More
4.5 TR (650CFM)

1

-

-

... More
5.5 TR (800CFM)

1

-

-

... More
Refrigerant Joints and Headers

-

-

-

... More
Supply, Installation, Testing and Commissioning of copper Y-Joints sets, distributer and headers, suitable for various sizes of gas and liquid line of VRF System complete as required for the above system.

84

-

-

... More
Corded/Cordless Remote Controller

-

-

-

... More
Supply, Installation, testing and commissioning of self diagnostic type Corded/Cordless remote controllers for operation of indoor units.

84

-

-

... More
Central Remote Controller

-

-

-

... More
Supply, Installation, testing & commissioning of Main intelligent central controller with Scheduled Timer system Touch screen Type suitable for groups of indoor units to operate, monitor, on/off, cyclic operation setting, temperature setting etc. The CRC shall be provided with suitable size metallic box with lock arrangement.

1

-

-

... More
Air Cooled Inverter Ductable Unit

-

-

-

... More
Supplying, installing, testing and commissioning of Air Cooled Ducted Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, Expension kit to connect with DX AHU, and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting.

-

-

-

... More
Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.

-

-

-

... More
Note: Providing and fixing of Powder coated M.S. angle iron frame work/Masonary Pedastal with required anti-vibration mounting for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation.

-

-

-

... More
Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard.

-

-

-

... More
Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulfur and other chemical contaminants present in the air. The coating should be done in the presence of OEM represantative. The coating shall be carried-out by the authorized applicator of coating manufacturer.

-

-

-

... More
5.5 TR Ductable Split Unit -Only Condensing

2

-

-

... More
8.5 TR Ductable Split Unit -Only Condensing

2

-

-

... More
Notes: The vendor may offer the outdoor units as per availability from the manufacturer, however keeping the tonnage same as per BOQ subject to approval by Consultant/Client.

-

-

-

... More
The indoor units capacity can be also as per availability from the manufacturer but keeping the minimum capacity as required in BOQ subject to approval by Consultant/Client.

-

-

-

... More
DOUBLE SKIN FLOOR MOUNTED AIR HANDLING UNIT WITH HEPA FILTER

-

-

-

... More
(For OT With 10 ACPH/Hr)

-

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted Direct Expension (DX Type) double skin type horizontal/vertical air handling units made of 50±1 mm thick panels consisting of pre plasticized G.I. casing of thickness 1.0 mm outside layer and 1.2 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine of density, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/ PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification.

-

-

-

... More
The cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in both the supply & exhaust side of AHU, fine filter section with filters of non woven synthetic media of 5 micron particle size in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost), mixing chamber complete with motor, belt drive etc. without face and bypass dampers. The AHU shall be accoustically insulated with 25mm thick open cell nitrile rubber & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section with starter panel. These AHUs shall have air inlet / outlet connection made of aluminium 20 G & all fixing arrangement / blank off shall be of SS, the complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 500 FPM (2.52 MPS) maxm & Fan outlet velocity shall be not exceed 9.0 m/s.

-

-

-

... More
Casing shall be of panel construction; double wall type packed with pressure injected CFC free foam insulation minimum 50mm ± 1mm thick. Casing framework shall be of modular galvanized iron, aluminium or Approved equal pentapost double skin construction. Outer skin shall be minimum 1.0 mm galvanized steel sheet while inner skin shall be minimum 1.2 mm galvanized steel sheet. The sheets should have a minimum galvanisation of 275 GSM. The outer skin and inner skin should be precoated or powder coated on the exposed side

-

-

-

... More
AHU shall be Eurovent certified. The mechanical performance of AHU shall be as per EN 1886. Rating performance for units, components and section shall be as per EN 13053. Fans shall be AMCA certified for

-

-

-

... More
Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
3000 CFM Supply Air, 8 Row CC, 125 mm St. Pr., For Supply Fan, Supply Fan, 1200 CFM Ex. Air Blower, 40 mm St. Pr. for Exhaust fan with other accessories as specified)

2

-

-

... More
DOUBLE SKIN FLOOR MOUNTED AIR HANDLING UNIT WITH FINE FILTER

-

-

-

... More
Supply, Installation, Testing and commissioning of factory built floor mounted Direct Expension (DX Type) double skin type horizontal/vertical air handling units made of 50±1 mm thick panels consisting of pre plasticized G.I. casing of thickness 1.0mm outside layer and 1.2 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine of density, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/ PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification.

-

-

-

... More
The cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in both the supply & exhaust side of AHU, fine filter section with filters of non woven synthetic media of 5 micron particle size in supply after fan, mixing chamber complete with motor, belt drive etc. without face and bypass dampers. The AHU shall be accoustically insulated with 25mm thick open cell nitrile rubber & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section with starter panel. These AHUs shall have air inlet / outlet connection made of aluminium 20 G & all fixing arrangement / blank off shall be of SS, the complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 500 FPM (2.52 MPS) maxm & Fan outlet velocity shall be not exceed 9.0 m/s.

-

-

-

... More
Casing shall be of panel construction; double wall type packed with pressure injected CFC free foam insulation minimum 50mm ± 1mm thick. Casing framework shall be of modular galvanized iron, aluminium or Approved equal pentapost double skin construction. Outer skin shall be minimum 1.0 mm galvanized steel sheet while inner skin shall be minimum 1.2 mm galvanized steel sheet. The sheets should have a minimum galvanisation of 275 GSM. The outer skin and inner skin should be precoated or powder coated on the exposed side

-

-

-

... More
AHU shall be Eurovent certified. The mechanical performance of AHU shall be as per EN 1886. Rating performance for units, components and section shall be as per EN 13053. Fans shall be AMCA certified for

-

-

-

... More
Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
2,500 CFM (7.0 TR), 40 mm St. Pr.,6 Row CC

1

-

-

... More
5,000 CFM (10.0 TR), 50 mm St. Pr.,4 Row CC

1

-

-

... More
12,000 CFM (30.0 TR), 65 mm St. Pr.,6 Row CC

1

-

-

... More
DOUBLE SKIN CEILING SUSPENDED AHU

-

-

-

... More
Supply, installation, testing and commissioning of factory fabricated Double Skinned Direct Expension (DX Type) Air- handling unit ceiling suspended type fabricated out of extruded aluminium section with 1.0 mm pre-plasticized / pre-coated Galvanised steel sheet outside & 1.2 mm plain Galvanised steel sheet inside with blower, blower section and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 4 Row cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, direct / belt drive as mentioned below etc. without face and bypass dampers. All direct driven fan motor shall be sourced from fan manufacturer & factory fitted only. The AHU panels shall be insulated with 23mm thick & 36 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only with starter panel. The complete AHU shall conform to standard specification.

-

-

-

... More
The cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, complete with motor, belt drive etc. without face and bypass dampers. The AHU shall be accoustically insulated with 25mm thick open cell nitrile rubber with 20 G perforated Galvanised steel sheet & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section with starter panel. The complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 500 FPM (2.52 MPS) maxm & Fan outlet velocity shall be not exceed 9.0 m/s.

-

-

-

... More
Casing shall be of panel construction; double wall type packed with pressure injected CFC free foam insulation minimum 50mm ± 1mm thick. Casing framework shall be of modular galvanized iron, aluminium or Approved equal pentapost double skin construction. Outer skin shall be minimum 1.0 mm galvanized steel sheet while inner skin shall be minimum 1.2 mm galvanized steel sheet. The sheets should have a minimum galvanisation of 275 GSM. The outer skin and inner skin should be precoated or powder coated on the exposed side

-

-

-

... More
AHU shall be Eurovent certified. The mechanical performance of AHU shall be as per EN 1886. Rating performance for units, components and section shall be as per EN 13053. Fans shall be AMCA certified for

-

-

-

... More
Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
AHU With fine filter section of non woven synthetic media of 5 micron particle size in supply after fan. Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
2,500 CFM (5.0 TR), 40 mm St. Pr., 4 Row CC

2

-

-

... More
3,000 CFM (6.0 TR), 40 mm St. Pr., 4 Row CC

2

-

-

... More
4,000 CFM (8.0 TR), 40 mm St. Pr., 4 Row CC

2

-

-

... More
4,000 CFM (10.0 TR), 50 mm St. Pr., 6 Row CC With Fine Filter

1

-

-

... More
KIT FOR AHUs

-

-

-

... More
Supply, Installation, Testing and Commissioning of VRV Kits for AHUs having all controllers & Electronic Expansion Valve (EEV) and temperature set arrangement. It Shall have cut off arrangement after a particular set value of Supply air Temperature. AHU Kits & Controllers

12

-

-

... More
THERMOSTAT FOR AHU

-

-

-

... More
Supply, installation, testing and commissioning of digital display type thermostat for air handling unit for cool / heat application suitable for four pipe system & humidistat suitable for working with humidifier and hot water coil control valves for various air handling Units.Controller have provision to display differential pressure accress OT if required. The thermostat shall have provision of setting of space temperature and display of the same.

-

-

-

... More
The humidistat shall have provision of setting space RH and display of the same. The quoted price of thermostat / humidistat shall include the cost of 20mm MS conduits, control cabling, MS Box etc as required. The cost quoted shall be excluding the control valves and humidifier

-

-

-

... More
Cooling / heating thermostat

12

-

-

... More
Snap Acting Humidistat at air-handler.

2

-

-

... More
HUMIDIFICATION PACKAGE

-

-

-

... More
Supply, installation, testing and commissioning of Humidification package with all necessary controls as required as per standard specification & of following capacities: 4.5 KW

2

-

-

... More
LAMINAR AIR FLOW

-

-

-

... More
Supply, installation & testing of factory fabricated Laminar air flow pattern perforated plenum made of 16 G aluminium sheet with hepa filters & suitable for operation theatre with all accessories as required to suit, site condition as per specifications. SIZE-2.4mx2.7m

2

-

-

... More
AIR COOLED DX TYPE SPLIT AC UNITS

-

-

-

... More
Supply , installation, testing & Commissioning of ceiling suspended DX type split AC units with air cooled condenser complete with 5 Star Inverter type scroll/rotary compressor ,condenser ,wiring & accessories . Indoor units shall be ceiling suspended/wall mounted type complete with evaporator ,fan, filter ,drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge , corded remote controls. The unit shall be suitable for working at 240 ± 10% ,50 Hz,1 phase AC supply .The unit shall be designed to take care of minimum vertical head 5mt & horizontal length of 30 mt & necessary oil separator shall be included ,Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy painted MS stand for ODU units as per approved make, shade by Architect) with necessary vibration isolation arrangement as per site condition etc. (without condensate drain pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid separately ).

-

-

-

... More
The coil in the outdoor units shall be provided with anti corrosive treatment. Necessary corrosive treatment of copper coil of the ODU with Blygold PoluAl (Aluminum hydroxide, 25-microns thickness) to protect from corrosion, sulfur and other chemical contaminants present in the air. Coating should be done in presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.

-

-

-

... More
The Outdoor unit Compressor must be provided with 5 Year Warranty Period.

-

-

-

... More
Silver Ion Filter, Dust Filter

-

-

-

... More
Civil Work such as wall hole making , wall chiseling ,refilling of chiseling part with mortar etc. as per site condition.

-

-

-

... More
Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts

-

-

-

... More
Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning.

-

-

-

... More
Incoming power supply shall be provided near each indoor units

-

-

-

... More
1.5 TR

2

-

-

... More
2.0 TR

3

-

-

... More
SCHEDULED TIMER FOR SPLIT AC

-

-

-

... More
Supply, installation, testing and commissioning of Scheduled Timer for wall mounted split type Air conditioning units.

3

-

-

... More
TRANSMISSION & CONTROL WIRING

-

-

-

... More
Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units. 2C x 1.5 Sq mm (Shielded-Unarmored)

1080

-

-

... More
REFRIGERANT PIPING

-

-

-

... More
Supply, fixing, testing and commissioning of interconnecting soft/hard drawn copper refrigerant pipe work of following outer diameter duly insulated with fire rated class'O' closed cell elastomeric nitrile rubber type tubular insulation (19mm/13mm thick) between indoor & outdoor units & protected with 28 G aluminium sheet cladding as per specifications. All piping should be laid on Galvanized/Powder Coated tray supported by Galvanized M S Hangers & Clamps and all external piping shall run in covered cable trays. The rate includes all the items required to complete the piping work and nothing extra should be payable except the cable tray.

-

-

-

... More
Vaccumiazation & Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU.

-

-

-

... More
Civil Work such as wall hole making , wall chiseling ,refilling of chiseling part with mortar etc. as per site condition.

-

-

-

... More
6.4 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

230

-

-

... More
9.5 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

270

-

-

... More
12.7 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

325

-

-

... More
15.9 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

410

-

-

... More
19.1 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

95

-

-

... More
22.2 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

60

-

-

... More
25.4 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

115

-

-

... More
28.6 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

165

-

-

... More
31.8 mm outer dia Hard Drawn with Tube Thickness-1.62mm ( Insulation-19 mm )

70

-

-

... More
34.9 mm outer dia Hard Drawn with Tube Thickness-1.62mm ( Insulation-19 mm )

105

-

-

... More
38.1 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )

65

-

-

... More
41.3 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )

70

-

-

... More
DRAIN PIPING

-

-

-

... More
Providing and fixing of cPVC drain water piping complete with fittings, flexible connection to IDU, necessary support as per specification and insulated with 6 mm thick fire rated class'O' closed cell elastomeric nitrile rubber insulation.

-

-

-

... More
25 mm dia

340

-

-

... More
32 mm dia

210

-

-

... More
40 mm dia

105

-

-

... More
VENTILATION FANS/AXIAL FLOW FANS

-

-

-

... More
Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung exhaust air tube axial flow fans of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency class IE3 (as per IS 12615) suitable for 3 Phase 50 Hz 415V ± 10 %, of class 'H' insulation etc. including all accessories complete as required and as per specifications. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Motor make shall be same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%, noise level should not be more than 78 db. @ 3 m distance when measured in hemispherical reverberant room conditions. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating. Entire fan model & AMCA Seal shall appear in technical submittal of fan. Air moving capacity shall be as follows:

-

-

-

... More
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
Fan shall be supplied with Spring Isolators, Fire Rated Flexible Connection, GI gravity louvers, bird screen and fan guard.

-

-

-

... More
Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans,(a) Noise level @ 3m from Fan shall be not more than 78 dB.

-

-

-

... More
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re­ entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.

-

-

-

... More
Note:-These fans would be connected to the fire alarm system & BMS system of the building and would start automatically in case of Fire

-

-

-

... More
Note 1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)

-

-

-

... More
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)

-

-

-

... More
3. Fan motor shall meet IE3 or above standard as per IS-12615

-

-

-

... More
4. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.

-

-

-

... More
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.

-

-

-

... More
2000 CFM (3400 CMH) at 25 mm static pressure

1

-

-

... More
3000 CFM (5100 CMH) at 25 mm static pressure -

2

-

-

... More
4000 CFM (6800 CMH) at 25 mm static pressure

2

-

-

... More
5000 CFM (8500 CMH) at 25 mm static pressure

2

-

-

... More
6000 CFM (10200 CMH) at 25 mm static pressure

1

-

-

... More
8000 CFM (13600 CMH) at 25 mm static pressure

2

-

-

... More
10000 CFM (17000 CMH) at 25 mm static pressure -

2

-

-

... More
AXIAL FLOW FANS (SUPPLY/PRESSURISATION FAN)

-

-

-

... More
Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung Supply/ Pressurisation tube axial flow fans of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency class IE3 (as per IS 12615) suitable for 3 Phase 50 Hz 415V ± 10 %, of class 'F' insulation etc. including all accessories complete as required and as per specifications. . Motor make shall be same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%, noise level should not be more than 78 db. @ 3 m distance when measured in hemispherical reverberant room conditions. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating. Entire fan model & AMCA Seal shall appear in technical submittal of fan. Air moving capacity shall be as follows:

-

-

-

... More
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
Fan shall be supplied with Spring Isolators, Fire Rated Flexible Connection, GI gravity louvers, bird screen and fan guard.

-

-

-

... More
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re­ entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.

-

-

-

... More
Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans,(a) Noise level @ 3m from Fan shall be less than 78 dBA. with starter panel

-

-

-

... More
Note:-These fans would be connected to the fire alarm system & BMS System of the building and would start automatically in case of Fire

-

-

-

... More
Note 1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)

-

-

-

... More
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)

-

-

-

... More
3. Fan motor shall meet IE3 or above standard as per IS-12615

-

-

-

... More
4. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.

-

-

-

... More
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.

-

-

-

... More
Supply Fan

-

-

-

... More
2000 CFM (3400 CMH) at 25 mm static pressure

1

-

-

... More
3000 CFM (5100 CMH) at 25 mm static pressure

2

-

-

... More
4000 CFM (6800 CMH) at 25 mm static pressure

2

-

-

... More
5000 CFM (8500 CMH) at 25 mm static pressure

2

-

-

... More
6000 CFM (10200 CMH) at 25 mm static pressure

1

-

-

... More
8000 CFM (13600 CMH) at 30 mm static pressure

6

-

-

... More
10000 CFM (17000 CMH) at 30 mm static pressure

6

-

-

... More
14000 CFM (17000 CMH) at 30 mm static pressure

3

-

-

... More
CABINET TYPE CENTRIFUGAL FAN :

-

-

-

... More
Supply, installation, testing, commissioning of direct driven double skin Cabinet type centrifugal fan with 25mm thick PUF insulation fan section consist of Centrifugal Fan, forward curve, with radial tip double wheel, double inlet, consisting of motor, drive arrangement, aluminum common frame for fan and motor, cushy foot mounting, aluminum base frame for the unit, VCD on the outlet of fan, filter and accessories as per specification and drawing complete with 25mm thick five layer GI wire mesh filter, Structural frame with blank-off sheet, anchor fastener with vibration isolation Springs and starter panel.

-

-

-

... More
Motor: Fan motor shall be energy efficient and suitable for 415±10% volts, 50 cycles, 3 phase AC power supply, squirrel-cage, totally enclosed, fan-cooled motor, provided with class H insulation, and of approved make. Motor name plate horsepower shall exceed brake horsepower by a minimum of 10%. Motor shall be designed especially for quiet operation and motor speed shall not exceed 1440 rpm. The fan and motor combination selected for the required performance shall be of the most efficient (smallest horsepower), so that sound level is lowest. Motor shall have a minimum efficiency of IE3 or as per relevant BIS/NEMA codes.

-

-

-

... More
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
Fan and motor shall be fire rated to 250 Deg C for 2 hours or as indicated in the specifications

-

-

-

... More
The motor shall be spark-proof. The starter panel shall be provided with in-built timer to switch OFF the fan after a preset time (say 300 seconds) once triggered

-

-

-

... More
Note:-These fans would be connected to the fire alarm system/BMS System of the building and would start automatically in case of Fire

-

-

-

... More
Note 1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)

-

-

-

... More
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)

-

-

-

... More
Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
5000 CFM with 35 mm static Pressure

1

-

-

... More
AIR SCRUBBER (DRY TYPE)

-

-

-

... More
Supply, Installation, Testing & Commissioning of factory fabricated Single Skinned Air-Scrubber unit floor mounted type with blower, blower section and blower motor . Air Scrubber having minimum 90% efficiency with centrifugal fan, mentalistic vibration isolation, Direct drive arrangement, VCD, distribution headers, access door, complete as per specifications & drawings. The unit shall be fire retardant, water proof double flexible connection at fan outlet and starter panel. The Industrial Electronic Air Cleaning System shall be supplied as a one-piece factory joined assembly of individual section(s) selected to treat oil mist, smoke, fume, grease & dust / powder problems.

-

-

-

... More
The unit shall provide efficiency of 90% or better for single pass base on ASHRAE test method at flow rates of 800 – 1500 CFM per module (supported by sample test report by a US laboratory).

-

-

-

... More
Housing shall be constructed with minimum 1.4 mm thick galvanized steel sheet (16 gauge) with reinforced structure and powder coated to protect against rust and corrosion. It shall have a hinged door for cell access, located one side to the unit. The door shall be gasketed to prevent air leakage. There shall be a safety interlock switch to cut off primary supply when the access door is opened.

-

-

-

... More
Ionizing-Collecting Cell(s) shall be of one-piece construction consisting of a series of repelling and collection plates. Both repelling and collector plates shall be aluminum alloy material, rigidly retained in place with tubular spacers and tie rods. Each plate shall be corrugated, perpendicular to airflow direction. Each cell shall weigh not more than 16 kg with at least 9 ionizing wires.

-

-

-

... More
Ionizing electrodes / wires shall be of tungsten material, rigidly supported both vertically and laterally. Ionizing electrode to ground electrode spacing shall be 1.0” (25 mm). High voltage support insulators shall be of Teflon material for dielectric strength.

-

-

-

... More
Each Ionizing / Collecting Cell shall be capable of handling up to 3000 cmh of air. There shall be one to four such ionizing / collecting cells per module. Each module shall handle up to 3000 CMH, 6000 CMH, 9000 CMH and 12000 CMH per module respectively. Multiple units of the same or different modules may be needed to handle higher air flow capacities.

-

-

-

... More
Sound level at 3mt distance at 1.5mt Height from fan outlet shall not be more than 80dbA.

-

-

-

... More
Power supplies shall be 100% solid state, operate on 240 VAC, 50 HZ, 1 Phase input and provide a dual high voltage output of 12 to 13 KVDC for the ionizer and 6.0 to 6.5 KVDC for the collector, in normal operation conditions. Current output at the high tension shall be 12mA. A maximum power output for the solid-state power supply shall be from 50 watts to up to 150 watts to maintain the specified collection efficiency.

-

-

-

... More
The rated efficiency shall be up to 95% based on the NIOSH 5026 OIL MIST TEST. Past on situ test reports of 90% to 95% of the said test method must be submitted.

-

-

-

... More
Outlet Velocity for fans not to exceed 10.0 MPS(Meter/Second)

-

-

-

... More
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
5,000 CFM with 50 mm static Pressure

1

-

-

... More
AIR WASHER :

-

-

-

... More
Supply, Installation, Testing & Commissioning of factory fabricated Double Skinned Air-washer unit floor mounted type fabricated out of extruded aluminum section with 0.8mm pre-plasticized /pre-coated Galvanized steel sheet outside & 0.8 mm plain Galvanized steel sheet inside with blower, blower section and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply. Air washer having minimum 90% efficiency with consisting of centrifugal fan, mounting arrangements, mentalistic vibration isolation, belt drive arrangement, VCD, distribution headers, access door, pump, stainless steel water tank, suction screen, impregnated cellulose paper fills, nylon prefilter, GI ‘B’ class piping & associated works, quick fill, makeup & drain connections with butterfly & float valves etc. complete as per specifications & drawings. The unit shall be fire retardant, water proof double flexible connection at fan outlet and with starter panel.

-

-

-

... More
Filters section shall incorporate synthetic washable filters of at least 50 mm thickness in suitable aluminum frame. Velocity of air across the fillers shall not exceed 500 fpm (2.5m/s). Outlet Velocity for fans not to exceed 10.0 MPS(Meter/Second)

-

-

-

... More
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.

-

-

-

... More
Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager.

-

-

-

... More
4000 CFM with 50 mm static Pressure

1

-

-

... More
INLINE FAN (Ceiling suspended)

-

-

-

... More
Supply, installation, testing, commissioning of Inline fan with vibration isolators, speed regulator, GI gravity louvers, Bird Screen and required cable as per specification and drawing. The Motor shall be suitable to run on 1 phase/50 hz/ 220 v electrical power Supply including fire retardant non-porous double layer flexible connection of the following capacity.The louvers & bird screen shall be made of heavy gauge metallic construction.

-

-

-

... More
200 CFM (340 CMH) at 10 mm static pressure

11

-

-

... More
300 CFM (510 CMH) at 10 mm static pressure

3

-

-

... More
400 CFM (680 CMH) at 10 mm static pressure

2

-

-

... More
500 CFM (850 CMH) at 12 mm static pressure

1

-

-

... More
600 CFM (1020 CMH) at 12 mm static pressure

2

-

-

... More
800 CFM (1360 CMH) at 12 mm static pressure

3

-

-

... More
1000 CFM (1700 CMH) at 15 mm static pressure

4

-

-

... More
PROPELLER FAN

-

-

-

... More
Supply, installation, testing and commissioning of wall mounted Propeller type heavy duty exhaust Fan of metallic construction complete with speed regulator, bird screen, gravity louvers, vibration isolators, required cable, plug & other accessories compete as required, suitable for single phase, 240± 10 volts, 50Hz AC. supply of following capacities:

-

-

-

... More
The louvers & bird screen shall be made of heavy gauge metallic construction.

-

-

-

... More
300 mm sweep dia (900 RPM)

4

-

-

... More
450 mm sweep dia (900 RPM)

2

-

-

... More
Supply, installation, testing & commissioning of Wall mounted Propeller type exhaust air fans of high grade ABS plastic construction complete with electric motor suitable for operation on 230 V+ 10%,50 Hz, 1 phase AC supply fitted with speed regulator, mountings frames, louvers and bird screen, required cable & plug to connect with socket etc. complete as required of following capacities. 250 mm sweep dia

25

-

-

... More
HYDROGEN (H2) SENSOR

-

-

-

... More
H2 Sensor for Battery room with IP-65 protection, long life, fast response with high accuracy and integrated with BMS Panel. Hydrogen level in Battery room as per Fire Code and CE/UL approved. These H2 sensors and controller are interface with fire alarm panel/BMS (as available) & Specification.

-

-

-

... More
Response Time10 sec

-

-

-

... More
Output-4-20mA or 2-10V, Supply-24V DC

-

-

-

... More
Controller

1

-

-

... More
H2Sensors

1

-

-

... More
AIR DISTRIBUTION WORKS (DUCTING,INSULATION,DAMPER, GRILLE & DIFFUSER)

-

-

-

... More
DUCTING FOR AIR CONDITIONING / VENTILATION

-

-

-

... More
FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS

-

-

-

... More
Supply, installation, testing and commissioning of factory fabricated Galvanized Steel (GSS) Sheet metal ducts complete with flanges, neoprene rubber gasket, elbows, Splitter Damper, vanes, hangers & support etc. as required as per IS/DW144/SAMACNA standard & confirming to specification. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.

-

-

-

... More
Note : Splitter Shall be a part of ducting.

-

-

-

... More
0.63 MM (24 Gauge )

575

-

-

... More
0.80 MM (22 Gauge )

210

-

-

... More
1.00 MM (20 Gauge )

1

-

-

... More
1.25 MM (18 Gauge) Plenum

50

-

-

... More
SITE FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS

-

-

-

... More
Supply, Fabrication, installation and testing of Galvanized Steel (GS) sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications.

-

-

-

... More
Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006

-

-

-

... More
0.63 MM (24 Gauge )

75

-

-

... More
0.80 MM (22 Gauge )

30

-

-

... More
1.00 MM (20 Gauge )

1

-

-

... More
1.25 MM (18 Gauge)

25

-

-

... More
FIRE RATED FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS

-

-

-

... More
Supply. Installation, testing and commissioning of Fire rated sheet metal ducts shall be fabricated from Lock Forming Quality grade prime galvanized steel sheet with flanges complete with supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Supporting distance shall not exceed 1.2 Mtr with 6mm thick fire retardant gasket suitable for 250 deg C 2 hr shall be used in duct joints along with fire sealants. Suitable access doors shall be provided at every 3m. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labor for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.

-

-

-

... More
All fire rated duct, smoke exhaust ducts shall be quoted with flame bar BWII or equivalent to achieve the required fire rating, also all the related accessories gaskets shall be suitable for the required fire rating.

-

-

-

... More
Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

-

-

-

... More
1.25 MM (18 Gauge) Plenum & Exhaust Duct

75

-

-

... More
ALUMINIUM (AL) DUCTING FOR OT

-

-

-

... More
Supply, installation, testing and commissioning of factory fabricated Aluminium Sheet metal ducts complete with flanges, neoprene rubber gasket, elbows, Splitter Damper, vanes, hangers & support etc. as required fot OT and as per IS/DW144/SAMACNA standard & confirming to specification. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.

-

-

-

... More
The joint between the ducts shall be done by means of polymer “flange / slide-in channel” system to prevent air leakages. Turning vanes, elbows and reducers to be considered as part of supply of ducts. Ducts shall be supported by cable supports / GI slotted channels with threaded rods. Internal Stiffeners shall be used to prevent bulging of ducts for the sizes above 800 mm.

-

-

-

... More
0.80 MM (22 Gauge ) With 32mm Insulation

90

-

-

... More
1.00 MM (20 Gauge ) With 32mm Insulation

45

-

-

... More
1.25 MM (18 Gauge) With 32mm Insulation

1

-

-

... More
Duct Insulation

-

-

-

... More
Supplying , installation, testing & commissioning of external thermal insulation on ducts with Closed Cell Elastomeric Nitrile Rubber Insulation of density not less than 50±5 Kg/m³ & thermal Conductive not exceeding 0.032 W/mK at an average Temperature of 0°C and . The Material Shall be rated as Class 1 as per BS476 Part7 for surface spread of flame test and Class O as per BS476 part6 for fire propagation test. The Material shall have Fire Approval from CBRI - Roorkee & no toxicity under flaming and non- flaming condition as per AITM 3.000 (1993). Adhesive used for setting the insulation shall be non - flammable, Vapour Proof. All Joints should be sealed with 3 mm thick 50 mm wide PE tape and Flange to be overlapped by 6" width of the same material thickness. Finally Duct insulated should be strapped by 12mm metallic Packing strip at every random meter & conforming to standard and Specification.

-

-

-

... More
19 mm

850

-

-

... More
25 mm

125

-

-

... More
ACCOUSTIC LINING

-

-

-

... More
AHU ROOM ACCOUSTIC LINING

-

-

-

... More
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.

-

-

-

... More
50 mm thick

150

-

-

... More
Duct Acoustic Lining

-

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 160 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.

-

-

-

... More
Acoustic lining in ducts/plenum up to 5.0 Running meter from Fan Outlet as per specification and drawings.

-

-

-

... More
20 mm For Duct

275

-

-

... More
25 mm For Plenum

110

-

-

... More
VOLUME CONTROL DAMPER

-

-

-

... More
Supply,. Installation, testing and commissioning of 18 Gauge G.I construction Frame with 22/24 Gauge GI Aero foil blades Volume control Duct/Wall Dampers with linkages, levers & fittings for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification.

4

-

-

... More
MOTRIZED VOLUME CONTROL DAMPER

-

-

-

... More
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room.

-

-

-

... More
Motorized (ON-OFF Type) duct mounted GI volume control damper

2

-

-

... More
Motorized (ON-OFF Type) duct mounted GI volume control Actuator

4

-

-

... More
BACK DRAFT DAMPERS

-

-

-

... More
Supply, Installation, testing and commissioning of 18 Gauge G.I construction Back draft Dampers for Controlling the recirculation of air with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum.

1

-

-

... More
PRESSURE RELIEF DAMPERS

-

-

-

... More
Supply,. Installation, testing and commissioning of 18 Gauge aluminum alloy extrusions with welded/cleated frames Pressure Relief Dampers for Controlling the Excess pressure up to 60pa with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum with suitable thickness.

2

-

-

... More
AIR TERMINAL (SUPPLY/RETURN/EXHAUST)

-

-

-

... More
Supply, installation, testing and commissioning of 50 micron Powder coated Aluminum extruded Air Terminal (Diffuser/Grille) as per specification & and drawings including fixing frames of GI in False ceiling/wall.

-

-

-

... More
Grilles

-

-

-

... More
Supply. Installation, testing and commissioning of powder coated extruded aluminium section grills with aluminium dampers for supply air terminal and grilles without damper for return air for air-conditioning as per specification.

-

-

-

... More
Grilles with Dampers

12

-

-

... More
Grilles without Dampers

15

-

-

... More
Diffusers

-

-

-

... More
Supply. Installation, testing and commissioning of powder coated extruded aluminium square diffusers with antismudge ring and removable core.

-

-

-

... More
Supply air with dampers

50

-

-

... More
Return air without damper

60

-

-

... More
Flexible Duct

-

-

-

... More
Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications.

-

-

-

... More
200 mm

175

-

-

... More
Slot Diffusers

-

-

-

... More
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.

-

-

-

... More
3-Slot Diffuser

1

-

-

... More
2-Slot Diffuser

1

-

-

... More
Linear Grille

-

-

-

... More
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille.

-

-

-

... More
100 mm

5

-

-

... More
150 mm

350

-

-

... More
200 mm

5

-

-

... More
Air Transfer Door Grille

-

-

-

... More
Supply and fixing of non vision air transfer door grille of powder coated extruded aluminium, single deflection grille with horizontal vanes arrangement etc. as per specifications and drawings.

8

-

-

... More
Exhaust/Fresh Air Louvers

-

-

-

... More
Supply, Installation, Testing and Commissioning of Fresh Air/Exhaust air Louvers minimum 80 mm deep comprising of inclined blade and extended-out lowest blade for disposal of rain water including the wire mesh, filter (washable type filter section Class-G3 having efficiency 80% down to 20 micron fitted in aluminium frame) . The louver shall be of extruded Aluminum construction, and powder coated to the approved finish and color.

5

-

-

... More
FIRE DAMPER

-

-

-

... More
Motorized Fire Dampers With Actuator

-

-

-

... More
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.

-

-

-

... More
Duct/Wall mounted multi blade, motorised fire & smoke dampers with spring return actuator. The damper shall be of at least 1.5 hr. fire rating and actuated with the help of 24 V electric actuator excluding. The damper shall be as per UL listed UL 555; 1995 and CBRI approved. The damper shall be constructed out of 16G galvanised steel sheet & as per specification with Control Cable to Potential Free Contact for tripping of AHU fan motor.

-

-

-

... More
Supply, installation, testing and commissioning of Motorised Spring Return Actuator for devices up to 0.8 sq. meter with control panel & temperature sensor.

-

-

-

... More
Fire Damper

4

-

-

... More
Actuator

6

-

-

... More
Under Deck Insulation of Exposed Roof

-

-

-

... More
Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code. 50mm

450

-

-

... More
ISOLATOR FOR OUTDOOR UNIT

-

-

-

... More
Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure .

-

-

-

... More
40A 4P MCCB(25 KA)

2

-

-

... More
63A 4P MCCB(25 KA)

22

-

-

... More
100A 4P MCCB(25 KA)

2

-

-

... More
POWER CABLING

-

-

-

... More
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender.

-

-

-

... More
Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes :

-

-

-

... More
4C x 16 Sq. mm Copper Conductor (Armoured)

125

-

-

... More
4C x 10 Sq. mm Copper Conductor (Armoured)

135

-

-

... More
4C x 6 Sq. mm Copper Conductor (Armoured)

270

-

-

... More
4C x 4 Sq. mm Copper Conductor (Armoured)

315

-

-

... More
EARTHING STRIP/WIRES

-

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

175

-

-

... More
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrode including connection/terminating with GI nut,bolt,spring,washer etc. as required.) jointing shall be done by overlapping &with 2sets of brass nuts bolt spring washer spaced at 50mm) 25mm x5mm

165

-

-

... More
MEDICAL GAS PIPE LINE

-

-

-

... More
Supply, Installation, Testing & Commissioning of Medical Gases Pipeline System complete with followings as per technical specifications & list of acceptable makes attached.

-

-

-

... More
OXYGEN SYSTEN

-

-

-

... More
10 + 10 size of oxygen manifold complete with middle

1

-

-

... More
frame, chains, NRV's and 20 nos. pig tail pipes

-

-

-

... More
3+3 size Oxygen emergency cyl. manifold complete

1

-

-

... More
with middle frame, chains and NRV's and fully automatic

-

-

-

... More
control panel for Oxygen

-

-

-

... More
Fully-Automatic pneumatically operated oxygen

1

-

-

... More
control panel ( Indian )

-

-

-

... More
Oxygen flowmeter complete with humidifier bottle

125

-

-

... More
Oxygen H.P. antistatic rubber tube (Imported)

50

-

-

... More
NITROUS OXIDE SYSTEM

-

-

-

... More
3 + 3 size of N2O manifold complete with middle frame,

1

-

-

... More
chains, NRV's 6 nos. pig tail pipes.

-

-

-

... More
2 Cyl. size of N2O emergency cyl. Manifold complete

1

-

-

... More
with middle frame, chains, NRV's

-

-

-

... More
Fully Automatic pneumatically operated N2O control

1

-

-

... More
panel. With heater

-

-

-

... More
Nitrous Oxide H.P. antistatic rubber tube (Indian)

50

-

-

... More
COMPRESSED AIR SYSTEM

-

-

-

... More
Compressed air system complete with oil free air

1

-

-

... More
compressor (2 nos. x 57.18 cfm) equipped with air

-

-

-

... More
receiver capacity of 2000 ltrs. and complete with Air

-

-

-

... More
Dryer of 60 cfm.

-

-

-

... More
3 stage ultra Filter & reducing station

1

-

-

... More
Compressed air H.P. antistatic rubber tube

80

-

-

... More
VACUUM CENTRAL SYSTEM

-

-

-

... More
Vacuum Central system complete with Vacuum pumps

1

-

-

... More
(2 nos.x 7V) reciproting base frame mounted with

-

-

-

... More
moter and 2000 ltrs. Capacity vacuum reservoir

-

-

-

... More
Bacterial filter station and secretion traps.

1

-

-

... More
Vacuum H.P. antistatic rubber tube

50

-

-

... More
Ward vacuum unit complete with regulator, collection

123

-

-

... More
bottle and adopter and bracket for collection bottle.

-

-

-

... More
Theatre vacuum unit complete with regulator, collection

3

-

-

... More
bottle and adopter and trolley.

-

-

-

... More
Medical Grade copper pipe with required copper fittings

-

-

-

... More
54mm outer dia, 1.2mm thick

60

-

-

... More
42mm outer dia, 1.2mm thick

255

-

-

... More
28mm outer dia, 0.9mm thick

510

-

-

... More
22mm outer dia, 0.9mm thick

1370

-

-

... More
15mm outer dia, 0.9mm thick

2110

-

-

... More
12mm outer dia, 1.0mm thick

640

-

-

... More
Zonal Valve Box WITH PRESSURE GUAGE

-

-

-

... More
6 Gas Services

2

-

-

... More
5 Gas Services (O2,N2O, Air-4bar, Air-7bar,Vac)

1

-

-

... More
4 Gas Services (O2,N2O,Air-4bar,Vac)

1

-

-

... More
for Minor OT's

-

-

-

... More
3 Gas Services(O2, Air-4Bar,Vac) for ICU's,Post-op,

6

-

-

... More
Recovery etc

-

-

-

... More
2 Gas Services (O2, Vac) for ward area

3

-

-

... More
COMBINED ELECTRICAL PANELS

-

-

-

... More
For compressed air system and vacuum system

1

-

-

... More
BED HEAD PANEL

-

-

-

... More
Provision for 2 Gas Outlet(O2-1+Vac-1) with 5 Amp.

131

-

-

... More
Switch & Sockets

-

-

-

... More
(For Ward, Isolation Room, Dilaysis, Res. Ward and Eclampsia)

-

-

-

... More
AREA LINE PRESSURE ALARM

-

-

-

... More
6 Gas Services (O2,N2O, Air-4bar, Air-7bar,Vac,AGSS)

2

-

-

... More
5 Gas Services (O2,N2O, Air-4bar, Air-7bar,Vac,)

1

-

-

... More
for Major OT's

-

-

-

... More
4 Gas Services (O2,N2O,Air-4bar,Vac)

1

-

-

... More
for Minor OT's

-

-

-

... More
3 Gas Services(O2, Air-4Bar,Vac) for ICU's,Post-op,

7

-

-

... More
Recovery etc

-

-

-

... More
2 Gas Services (O2, Vac) for ward area

3

-

-

... More
Master Alarm 16 Windows

1

-

-

... More
Floor Isolation Valve

-

-

-

... More
15 MM

8

-

-

... More
22MM

13

-

-

... More
28 MM

14

-

-

... More
42 MM

6

-

-

... More
54 MM

1

-

-

... More
Medical Gas Outlet Points / Terminal Unit for Oxygen, N2O, Compressed Air, and Vacuum

-

-

-

... More
Oxygen as Per HTM 2022

197

-

-

... More
Compressed M.Air- 4Bar outlets as Per

85

-

-

... More
HTM 2022

-

-

-

... More
Compressed M.Air- 7Bar outlets

3

-

-

... More
Vacuum outlets as per HTM 2022

198

-

-

... More
N2O as per HTM 2022

3

-

-

... More
AGSS Outlets

3

-

-

... More
MODULAR OPERATION THEATRES

-

-

-

... More
Wall and Ceiling Cladding

-

-

-

... More
Prefabricated Walls & Ceiling

-

-

-

... More
Providing and installing Walls & ceiling panels, constructed with 0.8 mm Stainless steel 304 grade PUF Panels with tongue and groove mechanism for jointing and minimum width of 1200mm. The puff panel shall be made by injecting high pressure polyurethane foam with minimum density 40 kg/m3. The thickness of wall panels shall be 50 mm thick and ceiling panel shall be 30 mm thick. The inner surface walls will be fixed to the bricks wall with essential supports. The individual wall panels will not be spot welded together so as to ease removal for maintenance at a later date. All joints will be filled with metal filler and sanded flush on site ready to receive the plastic finish.

285

-

-

... More
Antibacterial / Antifungal Paint

-

-

-

... More
Providing and applying Antibacterial Paint: The internal surfaces of the room

-

-

-

... More
walls will be sprayed with water based liquid plastic, wall glaze or equivalent anti-bacterial paint, approved by the architect to a minimum dry film thickness of 300 microns. The plastic coating will overlap the floor covering ceiling system and doorframes by 25mm to provide a continuous sealed surface. The plastic coating will be non- reflective and the Colour will be submitted to the architect for approval.

170

-

-

... More
Laminar Air Flow System

-

-

-

... More
SITC of Ceiling filtration system 2400x2400mm: The ceiling filtration system shall be 2.40 meters x 2.40 meters and will be integrated with the adjacent false ceiling. The ceiling shall be constructed with a plenum box supplied with conditioned air from the central system via 8 nos. HEPA filters (European Norm EN 1822:2009; Class H 14; DOP 99.97-99.9999% efficiency for 0.3 micron particles) with pressure drop of 300 Pascal’s at its nominal flow rates (supplied with the Plenum), mounted on the exit from the supply ducting.

2

-

-

... More
Conductive Seamless Flooring with Coving on all Corners

-

-

-

... More
SITC of Operation theatre flooring (antistatic conductive) : 2 mm Full Body Conductive Vinyl, laid on a semiconductive adhesive base. The floor finish should terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. All joints should be welded with electrodes of the same compatible material to provide a continuous sealed surface

125

-

-

... More
Hermetically Sealed Sliding Door System

-

-

-

... More
Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed OT door having high density particle board cores, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1800 x 2100 mm (W x H). Automatic Doors: Provided with Radar Switch - 2 Nos., Foot Switch - 2 Nos. and Photocell Sensors (Anti Crush Feature) & as per tech. specs. attached.

-

-

-

... More
Automatic Door (1800 mm x 2100 mm)

2

-

-

... More
Automatic Door (1000 mm x 2100 mm)

2

-

-

... More
Surgeon Control Pane

-

-

-

... More
Supply, installation, testing & commissioning of Operation theatre control panel Membrane type :

2

-

-

... More
· Time Day Clock

-

-

-

... More
· Time Elapse Clock

-

-

-

... More
· General and RGB Lighting System control (Peripheral Lights and plenum lights with dimming)

-

-

-

... More
· Medical Gas Alarm Panel 5 Gas – low, normal and high pressure with sequencing as per HTM 02 01

-

-

-

... More
· Hand Free Telephone set with speaker

-

-

-

... More
· Temperature & humidity indicator with controller

-

-

-

... More
· HEPA Filter Status module

-

-

-

... More
· Room Pressure Indicator / differential pressure indicator

-

-

-

... More
· USB Stick port

-

-

-

... More
X-Ray View Screen

-

-

-

... More
Supply, installation, testing & commissioning of Twin Plate LED X ray viewing screen: Size: 940 x 640 x 50 mm approx. with viewing area, Two plate X-ray view screen (120 W), LED based technology with colour temperature 6000K and lamp life 50,000 hrs and brightness in excess of 4000 lux.

2

-

-

... More
Writing White Board

-

-

-

... More
Supplying & fixing of sturdy writing Operating list board: made of ceramic surface having Magnetic properties and should be flushed to the wall of the operating room. Size 940mmx640mmx50mm

2

-

-

... More
Pressure Release Damper

-

-

-

... More
Supply, installation, testing & commissioning of SS Fabricated Cascade Pressure relief dampers: Suitably sized air pressure relief damper should be placed enabling differential room pressure to be maintained. Counter- weight

2

-

-

... More
balancing system should be provided in the PRD to maintain positive pressure inside the operation room.

-

-

-

... More
Peripheral Lights

-

-

-

... More
Supply Installation and Commissioning of 42W Bottom Opening Room fixture with IP 65, Led make should be Nichia /Seoul 5 SDCM , Own make BIS certified Islocated Driver , Flicker Free , Class 2 SELV driver, Operating temperature: -10°C to +45°C, Operating voltage range: 140-270V, Surge protection 3.5 KV, High Efficiency driver: 80-85% ,Low Voltage Cut Off below 130V, Output short circuit protection , Fixture Made up of MS powder coated white after phosphochromate treatment provided as standard with sheet thickness of 1.2MM, Diffuser of High impact polycarbonate opal diffuser with thickness 1.5MM for glare free uniform light distribution, power coating : 60 Microns , Lamp Source :High efficiency long life LED package in integral module with lumen efficacy of 140 lm/W and viewing angle of 120° to ensure better uniformity,Average life L70B50: 50000 hours, THD10%, PF.95, System efficacy 95-100 Lm/W, CRI80 ,IP65, IK05 Impact rating, . Dimension Will Be 1240X330X115mm, Safety test as per IS:15885 Part 2/Sec 13.

16

-

-

... More
Surgeon Pendant

-

-

-

... More
Providing & fixing of Ceiling mounted Single arm pendant systems for surgeon: The Weight carrying capacity of the arm should not be less than 180 Kgs load. There should be 5 or 6 nos. equipment loading shelves. double column of 1000mm. Single Arm Pivot range minimum 900mm or above. The brake (Electromagnetic) supplied with Indian Origin Multipin 6/16amp electrical switch + socket – 5 nos., It should have 2 no. RJ 45 data socket. It should have provision for 06 gas outlet points

2

-

-

... More
· 2 Oxygen,

-

-

-

... More
· 1 SA7,

-

-

-

... More
· 1 CO2,

-

-

-

... More
· 1 Vacuum

-

-

-

... More
Capable of 340 degrees of rotation. Medical gas terminal units shall be provided by the MGPS vendor and shall be installed in the pendant.USFDA

-

-

-

... More
Anaesthesia Pendant

-

-

-

... More
Ceiling mounted rigid pendant systems for anaesthesia: Single Arm motorized type pendants Made of Aluminum, powder coate with electromagnetic Brakes Swivel angle 0-330 degree

-

-

-

... More
Dimensions: Double Vertical column 1200 mm

-

-

-

... More
Vertical lift: 600 mm Horizontal arms – total 1000 mm Pendant should be prepiped Provided with 5 nos medical gas outlets. Outlets shall be connected to dual circuit being provisioned for all Oxygen 2 outlets Nitrous Oxide 1 outlets Vacuum 1 outlets Medical Air 1 outlets AGSS 1 outlet colour coded high pressure tubing for each gas with NIST connectors at ceiling Provided with prewired 10 nos 6 / 16 amps sockets and two data sockets RJ 45

-

-

-

... More
Instrument loading capacity 180 kgs. Shelves:

-

-

-

... More
Two with handle and two rails each with capacity of 40 kgs Drawers one with handle and two rails

-

-

-

... More
load capacity 40 kgs Swiveling stainless steel vertical pole

2

-

-

... More
Scrub Station

-

-

-

... More
Supplying, Installation, Testing & Commissioning of floor mounted, Scrub station: Compact surgical 2 bay scrub sink designed for use in OT complex. Each fixture fabricated from heavy gauge 1 mm thick type 304 stainless steel of seamless welded construction, polished to a smooth finish with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers. Hands free operation should include infra-red sensors with built-in range of adjustment. Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of approximately 1 to 3 min should be available.

-

-

-

... More
(Size: 1500mm X 675mm X 1105mm for 2 persons)

2

-

-

... More
Electrical DB

-

-

-

... More
SITC of Electrical distribution board: should house the transformers, if any, mains failure relays, electrical distribution equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectors with screw and clamp spring connections of the Clip-on type mounted, on a DIN rail and labelled with indelible proprietary labels. Individual fuses or miniature circuit breakers should protect all internal circuits.

2

-

-

... More
Storage unit:

-

-

-

... More
Storage unit: 1 mm thick Stainless Steel sheet 304. The storage unit should be divided 4 equal parts and each part should have individual swing 8 mm toughened glass doors with high quality stainless steel self-closing hinges capable of 180 degree swing out and secure locking system. Each part will be provided with removable stainless steel racks made from ½” circular (outer diameter) seamless Stainless Steel 304 tubes of 1 mm thickness placed at intervals of 1.5” center to center. The overall dimension of the storage unit shall be 1500mm (Width) x 2100mm (Height), 350mm depth being variable to suit architectural layout.

2

-

-

... More
LED Operating Light

-

-

-

... More
LED operating light having following specifications:-

-

-

-

... More
Maximum luminance (1m): 160,000 + 160,000 Lux at 1m distance, Electrical power: 150 + 90 W, Power consumption: 2x 11 A, Fitting: Ceiling anchoring ring ceiling pendant with 2 brackets and 2 spring arms, Range of movement: 1x 360° / 1x 330°, Recommended room height: at least 2.45 m, Max. ceiling load: 2x 218 Nm / 650 N, Light body weight: 9.2 + 7.5Kgs, Light body depth: 1x 130 cm / 1x 140 cm, Air shielding surface: 2 x 330 cm2 Transformers: 2x 450VA/230V/26V, Brightness regulator: 2x 20 – 500 VA (primary voltage), Provided with 2 Sterilisable handles with each dome, Easy positioning by sterilisable handle, Focus adjustable by sterilisable handle, Life time of Bulbs : 50,000 hours

2

-

-

... More
MGPS Inside OT

2

-

-

... More
MINOR OT

-

-

-

... More
Wall & Ceiling Cladding

-

-

-

... More
Prefabricated Walls & Ceiling(Approved Make: TATA/Jindal/Essar

-

-

-

... More
Providing and installing Walls & ceiling panels, constructed with 0.8 mm Stainless steel 304 grade PUF Panels with tongue and groove mechanism for jointing and minimum width of 1200mm. The puff panel shall be made by injecting high pressure polyurethane foam with minimum density 40 kg/m3. The thickness of wall panels shall be 50 mm thick and ceiling panel shall be 30 mm thick. The inner surface walls will be fixed to the bricks wall with essential supports. The individual wall panels will not be spot welded together so as to ease removal for maintenance at a later date. All joints will be filled with metal filler and sanded flush on site ready to receive the plastic finish.

100

-

-

... More
Antibacterial / Antifungal Paint

-

-

-

... More
Supply & laying of water based aseptic & self sterilizing wall coating with Anti fungal & Anti Bacterial Paint and other related painting components (viz: Primer, Putti etc.) of approved make and shadesso as to present a joint less finish etc. as per tech. specs. attached.

68

-

-

... More
Conductive Seamless Flooring with Coving on all Corners

-

-

-

... More
Supplying and laying of 2mm thick washable anti static seamless flooring with perfectly curved flash coving, resistant to mechanical stresses & dynamic loads & having ESD / EMI (conductive) protection characteristics. (Approx.), Coved Corners of approved make & shade. The joints of PVC tiles should be welded by special PVC thermal welding units using PVC welding bars colours. It should be scratch proof. The PVC flooring should be inert to body fluids, chemicals and disinfectants and should not be affected by temperature variation in the OT. The floor should efficiently discharge electric charges up to 2 kV. The conductive copper grid laid underneath the PVC sheet should be supported by liquid epoxy compounds allowed to set as a uniform and level surface & as per technical specs attached.

42

-

-

... More
Hermetically Sealed Sliding Door System

-

-

-

... More
Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed OT door having high density particle board cores, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H). Automatic Doors: Provided with Radar Switch - 2 Nos., Foot Switch - 2 Nos. and Photocell Sensors (Anti Crush Feature) & as per tech. specs. attached.

-

-

-

... More
Automatic Door (1500 mm x 2100 mm)

1

-

-

... More
Surgeon Control Panel

-

-

-

... More
Supply, installation, testing & commissioning of multi colour coded Surgeon Control Membrane Membrane Panel, flushed in the theatre wall comprising of the following features & as per technical specification attached: 1. Display of Day Clock 2. Display of Elapse Time Clock 3. Dimmer for peripheral lights 4. Medical Gas Alarm 5. Hands free telephone 6. Indicator for temperature & Humidity

1

-

-

... More
Peripheral Lights (Dimmable)

-

-

-

... More
Supply, installation, testing & commissioning of Recess Mounted IP54 LED clean room protocol, non–hygroscopic peripheral lights having CRCA housing lumen pack of 5600Lm with system wattage of 60 watt. The fitting should be Bottom opening type with high reflected clear acrylic glass with dimmer control from the Surgeon Control Panel. Specially designed for Clean Room Applications, such as Modular OT & as per tech. specs attached.

8

-

-

... More
Surgeon Pendant

-

-

-

... More
Providing & fixing of single arm (900mm) Surgeon pendant with load carrying capacity of 80Kg and rotational values of 330-340 degree with adjustable stopper. The pendent should be designed with service head to host, base, gas module, electric modular and shelves upto 8 gas outlets & 10 Electrical switches. Racks & Shelves should be provided to mount the equipments like monitor etc. The surgeon pendent should have Single arms as per technical specs attached.

1

-

-

... More
Electric Distribution Box, Wiring, Conducting, Electrical Boards & Other Electrical Fittings - upto the Distribution Box

1

-

-

... More
MGPS Piping Work with in the theatre

3

-

-

... More
CSSD WORK

-

-

-

... More
Horizontal Rectangular High Pressure High Vacuum Double Door Sterilizer.

2

-

-

... More
The sterilizer will be manufactured as per IS:No.3829 (Part 1)-1978 with ISI Mark. The unit will be designed for operating pressure 30 to 32 psi. and corresponding to a temperature of 134oC. The sterilizer chamber would be formed out of SS 316. The Jacket will be formed out of mild steel. The jacket outer cover will be of SS 304. The sterilizer will be provided with 2 Nos. pressure locking type hinged doors. The door plate will be of SS 316 with shooting bolts,flush mountings and steam generator will be of SS 304. The stand of the sterilizer will be of mild steel. The Sterilizer will be automatic with PLC with 5 pre-sets programs and 1 variable program, MMI with Dot-matrix printer wherein date, time, load identification no. cycle selected, cycle parameter including time, temperature and phase etc. can be seen and documented. Finally, the automation is so designed that once the program is selected then no further intervention is required from the operator till the end of the program. The sterilizer will also be provided with an intelligent transducer for heater protection. The unit will be complete with vacuum pump and condenser and inter- connecting piping. Sterilizer as above of chamber size 600 mm x 600 mm x 1200 mm depth (2’x2’x4’) suitable for electrical operation on 400/440 volts, 3 phase, AC supply, electrical load 21 KW.600 x 600 x 1200 mm-Capacity 432 liters.

-

-

-

... More
Stainlesss Steel 316 carriage suitable for Rectangular Sterilizer

2

-

-

... More
Stainlesss Steel 304 trolley suitable for above carriage

2

-

-

... More
S.S. Control and packing table with drawer

1

-

-

... More
table is used for separation, control and packing of various sets of sterilized goods for wards, clinics, operation theatres etc. and is designed for standing and sitting workers. A removable hatch made of laminated particles board is provided. The hatch contains a SS drawer and a laminated particles board plate. Overall size: 2000mm L x 1400mm W

-

-

-

... More
Stainless steel Work Table

2

-

-

... More
Table is used for wet goods with undershelf. The table top is fabricated out of 16 SWG SS 304 qlty. ground and polished to a smooth surface without high edge sections. The table top frame is a complete assembly with front, back and two ends welded together at corners. Overall size 1500mm x610x890Ht.

-

-

-

... More
S.S. Vertical Sliding Door

1

-

-

... More
Door is used between clean and dirty areas in hospitals, pharmaceuticals etc. The sliding door is mounted on an existing wall opening. The door is made of stainless steel counter- balanced by built in counterweight. The door is provided with nylon wheels at the side for easy of movement. The door is made along with stainless steel cover plates for the wall opening. The door is provided with a built in safety lock which ensures the door from closing if the counterweight rope breaks. Opening 500 x 500mm

-

-

-

... More
Stainless steel work table with two sink

1

-

-

... More
The bench top is fabricated out of 16SWG SS 304 qlty. ground and polished with smooth surface and edge section. The top is designed to give a stable work surface. The table top frame is a complete assembly with front, back and two ends welded together. The sinks are made of stainless steel with inside ground and polished. Each sink is provided with a drain valve and a strainer. On the bench top, just above the sinks mixer for hot and cold water connection is provided. Overall size 2400mmL x650mm Wx900mm Ht

-

-

-

... More
Washer Disinfector

1

-

-

... More
Washer Disinfector, single door, suitable for cleaning and disaffection of surgical instruments, anesthetic equipment, suction bottles, cleaning buckets, general circulation goods, dental tray and glassware with a fully closed process. The washer disinfector, fully automatic, has an advanced micro-processor which controls all services, programming and statistic functions. For safety reasons the service and programming functions are coded. The door would be provided with interlocking system. The chamber is equipped with four spray arms which ensure good water penetration from all directions. Various attachments are provided to suit the load to be washed. Suitable dosage of detergent can be preset with the dosing pump. The provision of a double wall with insulation in between enables the Washer Disinfector to run with minimum sound and heat emission. The wash chamber, the inside the door, the pipework system and the circulation arms are made entirely of stainless steel. Suitable for electrical operation on 400/440 volts, 3 phase, AC supply, electrical load 13 KW. Capacity of 275 ltrs.

-

-

-

... More
Ultrasonic Cleaner

1

-

-

... More
Ultrasonic Cleaner of overall size 530mm L x 330mm W x350mm H Internal Dimensions: 505 x 300 x 200 mm, output frequency 35khz. Capacity 30 litres. The Ultrasonic cleaners are manufactured using Solid State technology For the Ultrasonic Generator and PZT Transducers for converting the electrical energy to mechanical vibrations in the cleaning liquid. The unit will be complete with a thermostat and a timer, insert basket for tank and tank cover. The unit is suitable for electrical operation on 220/240 Volts, single phase, 50 cycles, AC supply.

-

-

-

... More
Drying Cabinet with single door

1

-

-

... More
Digital timer Controlled Drying Cabinet with single door suitable for easy and quick drying of instruments, utensils, glass wares and anesthetic accessories such as corrugated hoses, breathing masks, respiration bags and surgical instruments trays etc. The unit would be provided with digital display with countdown drying time and drying time selectors, temperature selector including indication of selected temperature. The system would have adjustable adjustment temperature range of 60-90oC. The system would have drying time range of 0-90 minutes. The system would take air from the work area and clean it by appropriate filter. The air is to be heated to an operator selected temperature by electric heating element. The system would also have an exhaust connection to vent outside. The unit would be provided with Cassettes and protective shelves for instruments, hoses, bladders and catheters as accessories. Chamber volume 275 litres. Suitable for electrical operation on 230 volts, single phase, 15 Amps. Electric load 3.6 KW.

-

-

-

... More
Stainless steel racks with 5 shelves, all sides open and stainless steel bullet feet. overall size 1830x535x1830mmH.

4

-

-

... More
Stainless steel table trolley with 2 shelves

2

-

-

... More
Stainless steel table trolley with 2 shelves is for use in the sterile goods store when batching sterile goods for delivery and also for short internal transport. The trolley is also suitable for use as a temporary storage or utility space at packing tables. The frame is mounted on 4nos. heavy duty swiveling castors for easy movement in narrow passages. Overall size 1080x530x800H

-

-

-

... More
Gauze cutting machine with SS table size 900x600x750mm

1

-

-

... More
Single Distilled Water Still

1

-

-

... More
Single Distilled Water Still, generally as per the Barnstead Type. The Still is guaranteed to produce pyrogen free and chemically pure water to comply with IP/BP Standards. The Still will be manufactured as per “IS:No.3830” and it will also bear the Bureau of Indian Standard Certification Mark. The evaporator, the multi-baffle and the condenser will be made out of stainless steel with the joints welded. The condenser will be provided with stainless steel tubes, water inlet and outlet connection. The Water Still will be supplied in a ready to use condition mounted on a suitable stand. Water Still as above of capacity 20 litres, per hour suitable for electric operation on 400/440 volts, 3 phase AC supply, electrical load being 15 KW.

-

-

-

... More
Stainless Storage tank, electric load 6 kw., capacity 120 litres.

1

-

-

... More
Spray Gun Rinser

1

-

-

... More
Spray Gun Rinser with attachments is used for cleaning syringes, catheters, endoscopes, cystoscopes and variety of other instruments and articles used in sterile services.

-

-

-

... More
HOSPITAL EQUIPMENT

-

-

-

... More
Supply, Installation / Fixing, Testing & Commissioning of Hospital Furniture complete with following as per technical specifications attached. & Approved Make:

-

-

-

... More
HYBRID (ICU - 20 Bed Unit)

-

-

-

... More
Motorized ICU Bed 4 Section With Mattress

20

-

-

... More
Bedside Locker

20

-

-

... More
Over Bed Table

20

-

-

... More
IV Stand With SS Rod & Castor Base

5

-

-

... More
Bed Side Stool

5

-

-

... More
Bio Medical Waste Bin-small -Set of 3

20

-

-

... More
Multi Para Monitor With Central Station

20

-

-

... More
ICU Ventilator

20

-

-

... More
Syringe Pump

20

-

-

... More
Infusion Pump

5

-

-

... More
Laryngoscope

2

-

-

... More
Thermometer - Infra red Type

5

-

-

... More
Ambu Bag Adult

5

-

-

... More
Aneroid BP Appartus

2

-

-

... More
Opthalmoscope

2

-

-

... More
ECG Machine 12 Channels

1

-

-

... More
Portable Ventilator

1

-

-

... More
Portable X-Ray

1

-

-

... More
Portable Ultrasound

1

-

-

... More
Biphasic Defibrillator

2

-

-

... More
ABG Machine With ISE

1

-

-

... More
Electronics Weighing Scale - Adult

2

-

-

... More
Electrical suction Apparatus

4

-

-

... More
Patient stracher (Fully SS)

2

-

-

... More
Wheel chair (Foldable)

2

-

-

... More
Crash Cart

1

-

-

... More
Dressing Trolley

1

-

-

... More
Drug Trolley/ Medicine cart

2

-

-

... More
ECG Machine Trolley

2

-

-

... More
Instrument Trolley

2

-

-

... More
Oxygen cylinder trolley

2

-

-

... More
Glucometer

4

-

-

... More
Stethosocope

4

-

-

... More
HDU- 20 BEDS

-

-

-

... More
Manual Bed 4 Section with Mattress

20

-

-

... More
Bedside Locker

20

-

-

... More
Over Bed Table

20

-

-

... More
IV Stand With SS Rod & Castor Base

10

-

-

... More
Bed Side Stool

20

-

-

... More
Bio Medical Waste Bin-small -Set of 3

20

-

-

... More
Multi Para Monitor With Central Station

20

-

-

... More
Syringe Pump

5

-

-

... More
Infusion Pump

5

-

-

... More
Laryngoscope

2

-

-

... More
Thermometer - Infra red Type

5

-

-

... More
Ambu Bag Adult

5

-

-

... More
Aneroid BP Appartus

4

-

-

... More
Opthalmoscope

2

-

-

... More
ECG Machine 12 Channels

1

-

-

... More
Portable Ventilator

2

-

-

... More
Biphasic Defibrillator

1

-

-

... More
Electronics Weighing Scale - Adult

2

-

-

... More
Electrical suction Apparatus

3

-

-

... More
Patient stracher (Fully SS)

1

-

-

... More
Wheel chair (Foldable)

1

-

-

... More
Crash Cart

1

-

-

... More
Dressing Trolley

1

-

-

... More
Drug Trolley/ Medicine cart

1

-

-

... More
ECG Machine Trolley

1

-

-

... More
Instrument Trolley

1

-

-

... More
Oxygen cylinder trolley

1

-

-

... More
Glucometer

2

-

-

... More
Stethosocope

2

-

-

... More
OPERATION THETARE -1

-

-

-

... More
OT Table

2

-

-

... More
OT Light

2

-

-

... More
Anestheisia Work station

2

-

-

... More
Surgical Diathermy

2

-

-

... More
Syringe Pump

2

-

-

... More
Infusion Pump

2

-

-

... More
Blood Fluid Warmer

2

-

-

... More
Biphasic Defibrillator

2

-

-

... More
Instrument Set

2

-

-

... More
Foot Step- Double

2

-

-

... More
Laryngoscope

2

-

-

... More
Radiant Warmer

2

-

-

... More
Thermometer - Infra red Type

2

-

-

... More
Ambu Bag Adult

2

-

-

... More
Electical Suction Apparatus

2

-

-

... More
Patient stracher (Fully SS)

1

-

-

... More
Wheel chair (Foldable)

1

-

-

... More
Crash Cart

1

-

-

... More
Drug Trolley/ Medicine cart

2

-

-

... More
Instrument Trolley

2

-

-

... More
Oxygen cylinder trolley

2

-

-

... More
Mayo trolley

2

-

-

... More
Glucometer

2

-

-

... More
Stethosocope

2

-

-

... More
EMERGENCY UNIT 10 Bed

-

-

-

... More
Manual Bed 4 Section with Mattress

10

-

-

... More
Bedside Locker

10

-

-

... More
Overbed table

10

-

-

... More
IV Stand With SS Rod & Castor Base

5

-

-

... More
Foot Step- Double

5

-

-

... More
Bio Medical Waste Bin-small -Set of 3

10

-

-

... More
Multi Para Monitor

10

-

-

... More
ICU Ventilator

4

-

-

... More
Syringe Pump

5

-

-

... More
Infusion pump

5

-

-

... More
Laryngoscope

2

-

-

... More
Thermometer - Infra red Type

2

-

-

... More
Ambu Bag Adult

5

-

-

... More
Aneroid BP Appartus

4

-

-

... More
Opthalmoscope

2

-

-

... More
ECG Machine 12 Channels

1

-

-

... More
Portable Monitor

1

-

-

... More
Portable Ventilator

1

-

-

... More
Portable X-Ray

1

-

-

... More
Biphasic Defibrillator

1

-

-

... More
Electronics Weighing Scale - Adult

2

-

-

... More
Electrical suction Apparatus

2

-

-

... More
Patient stracher (Fully SS)

1

-

-

... More
Wheel chair (Foldable)

1

-

-

... More
Crash Cart

1

-

-

... More
Dressing Trolley

2

-

-

... More
Drug Trolley/ Medicine cart

2

-

-

... More
ECG Machine Trolley

1

-

-

... More
Instrument Trolley

2

-

-

... More
Oxygen cylinder trolley

2

-

-

... More
Glucometer

4

-

-

... More
Stethosocope

2

-

-

... More
ISOLATION ROOM-12 BEDS

-

-

-

... More
Manual Bed 4 Section with Mattress

12

-

-

... More
Bedside Locker

12

-

-

... More
Overbed table

12

-

-

... More
IV Stand With SS Rod & Castor Base

5

-

-

... More
Bio Medical Waste Bin-small -Set of 3

12

-

-

... More
Portable Monitor

1

-

-

... More
Syringe Pump

5

-

-

... More
Infusion pump

5

-

-

... More
Laryngoscope

1

-

-

... More
Thermometer - Infra red Type

5

-

-

... More
Ambu Bag Adult

5

-

-

... More
Aneroid BP Appartus

2

-

-

... More
Opthalmoscope

1

-

-

... More
ECG machine 12 Channels

1

-

-

... More
Electronics Weighing Scale - Adult

2

-

-

... More
Electrical suction Apparatus

2

-

-

... More
Patient stracher (Fully SS)

1

-

-

... More
Wheel chair (Foldable)

1

-

-

... More
Crash Cart

1

-

-

... More
Dressing Trolley

1

-

-

... More
Drug Trolley/ Medicine cart

1

-

-

... More
ECG Machine Trolley

1

-

-

... More
Instrument Trolley

1

-

-

... More
Oxygen cylinder trolley

1

-

-

... More
Glucometer

1

-

-

... More
Stethosocope

2

-

-

... More
DIALYSIS - 4 Beds

-

-

-

... More
Manual Bed 4 Section with Mattress

4

-

-

... More
Bedside Locker

4

-

-

... More
Over Bed Table

4

-

-

... More
IV Stand With SS Rod & Castor Base

2

-

-

... More
Hemodialysis Machine

4

-

-

... More
CRRT Machine

1

-

-

... More
RO Plant System

1

-

-

... More
Dialysis Reprocessor

1

-

-

... More
Multi Para Monitor

4

-

-

... More
Infusion pump

2

-

-

... More
Syringe Pump

2

-

-

... More
Laryngoscope

1

-

-

... More
Thermometer - Infra red Type

1

-

-

... More
Ambu Bag Adult

1

-

-

... More
Biphasic Defibrillator

1

-

-

... More
Electronics Weighing Scale - Adult

1

-

-

... More
Wheel chair (Foldable)

1

-

-

... More
Crash Cart

1

-

-

... More
Dressing Trolley

1

-

-

... More
Drug Trolley

1

-

-

... More
Glucometer

1

-

-

... More
Stethosocope

2

-

-

... More
MCH -06 Bed

-

-

-

... More
Ward Bed (2 section) with mattress

6

-

-

... More
Bedside Locker

6

-

-

... More
IV Stand With SS Rod & Castor Base

6

-

-

... More
Bio Medical Waste Bin-small -Set of 3

3

-

-

... More
Crash cart

1

-

-

... More
Instrument Trolley

2

-

-

... More
Glucometer

2

-

-

... More
Stethosocope

1

-

-

... More
LDR - 02 Bed

-

-

-

... More
LDR Bed

2

-

-

... More
Foctal Doppler machine

2

-

-

... More
Radiant warmer

2

-

-

... More
Bedside Locker

2

-

-

... More
IV Stand With SS Rod & Castor Base

2

-

-

... More
Bio Medical Waste Bin-small -Set of 3

2

-

-

... More
Crash Cart

1

-

-

... More
Instrument Trolley

2

-

-

... More
Glucometer

2

-

-

... More
Stethosocope

2

-

-

... More
ISOLATION WARD -30 Bed

-

-

-

... More
Ward Bed (2 section) with mattress

30

-

-

... More
Bedside Locker

30

-

-

... More
IV Stand With SS Rod & Castor Base

10

-

-

... More
Bio Medical Waste Bin-small -Set of 3

10

-

-

... More
Portable Monitor

1

-

-

... More
Pulseoximeter

2

-

-

... More
cap/bipap machine

5

-

-

... More
Syringe Pump

5

-

-

... More
Infusion pump

5

-

-

... More
Laryngoscope

2

-

-

... More
Thermometer - Non contact type

5

-

-

... More
Ambu Bag Adult

5

-

-

... More
Aneroid BP Appartus

5

-

-

... More
Opthalmoscope

2

-

-

... More
ECG machine 12 Channels

1

-

-

... More
Electronics Weighing Scale - Adult

3

-

-

... More
Electrical suction Apparatus

3

-

-

... More
Patient stracher (Fully SS)

2

-

-

... More
Wheel chair (Foldable)

2

-

-

... More
Crash Cart

1

-

-

... More
Dressing Trolley

2

-

-

... More
Drug Trolley/ Medicine cart

2

-

-

... More
Instrument Trolley

2

-

-

... More
Oxygen cylinder trolley

2

-

-

... More
Glucometer

4

-

-

... More
Stethosocope

4

-

-

... More
ADMINISTRATIVE FURNITURE

-

-

-

... More
Supply, Installation / Fixing,/Testing & Commissioning of Furniture complete with following as per technical specifications attached. Make: Make:MPS/ Godrej / Hospital Engineering

-

-

-

... More
Reception / staff Nurse Station Reception TableL1500*600D*1050H with 3drawer unit

21

-

-

... More
Work station 1500*750mm with side unit 900*450D*600H 3 drawer +shutter

21

-

-

... More
Work station 1600*750mm with side unit 900*450D*600H 3 drawer +shutter

12

-

-

... More
Staff seat 1500*600mm ;02 nos with 3 drawer unit

8

-

-

... More
Staff seat 1500*600mm ;02 nos with 3 drawer unit

18

-

-

... More
Staff seat 1500*600mm ;02 nos with 3 drawer unit

2

-

-

... More
Staff seat 1200*600mm ;02 nos with 3 drawer unit

32

-

-

... More
Storage total 09 unit L900*400D*1200H

96

-

-

... More
2 seater,Sofa

20

-

-

... More
1 Seater,Sofa

20

-

-

... More
High Back Chair Knee Tilt Mechanism- Synchro Knee Tilt PU Arm Gas Lift Chrome Plated Metal Base Mesh back

33

-

-

... More
HIGH BACK CHAIR Glsss filled nylon frame structure Headrest with multiple adjustments Taiwan wire mesh 2 way lumber adjustment Multilock synchrotilt mechanism 3d bend hot pressed seat ply Seat plastic cover High density pu foam seat cushion Foam mesh on the seat 6 way adjustable arm with pu pad class 3 gas lift Telescopic cover for gas lift Glass filled nylon base and castors.

150

-

-

... More
3 seater Chair

25

-

-

... More
2 Seater Chair

20

-

-

... More
CURTAIN & IV HANGER SYSTEM

-

-

-

... More
Supply, Installation, Testing & Commissioning of Curtain & IV Track System complete with following as per technical specifications attached.

-

-

-

... More
Providing and installation of Cubical tracks system made of Powder coated Aluminium alloy, mounted on the ceiling using Suspension hangers and bushes, powder coated wall bracket and Track Joiners wherever required. This system shall be complete with stain free polyster fabric, Water repellent Curtains having 18" Net on top. The curtain shall be approx 7X4 feet, with two curtains stiched together wherever required. Curtains shall also be provided with smooth movement, non sticking runners, with Stainless steel hooks, for easy movement. The system shall have curtain removal points and end cap complete as per technical specifications wherever is required.

80

-

-

... More
Providing and installation of I.V. Hanger with 5 hooks, made from mirror finish stainless steel, 304 grade with adjustable height, provided with 4/6 feet aluminium alloy track powder coated with endcap of tracks, 1 pc of trolley for smooth IV Hanger movement on track, 2 pcs of suspension hanger powder coated, top & bottom bush, powder coated, for easy fitting and better aesthetics complete as per technical specifications is required.

80

-

-

... More
CRESS & CORNER GUARD

-

-

-

... More
Supply & apply Instalation of SM20 90 degree, surface mounted corner guard, 76 mm legs, aluminum retainer, caps included. Cut sizes and quantities to be listed below.

100

-

-

... More
SM20N Cut no.1: Quantity: 450 pcs. @ Length: 1050 mm. PVC regrind absorption cushion.

-

-

-

... More
C.  Aluminum: Extruded aluminum should be 6063-T6 alloy, nominal  thickness. Minimum strength and durability properties as specified in ASTM B221

-

-

-

... More
Supply & apply Instalation of SCR 50  Surface mounted crashrail, 127 mm deep. Product to be

-

-

-

... More
supplied in 3000 mm lengths.With Standard End Cap Regrind PETG: PVC-PVC regrind absorption cushion.

-

-

-

... More
C.  Aluminum: Extruded aluminum should be 6063-T6 alloy, nominal  thickness. Minimum strength and durability properties as specified in ASTM B221

500

-

-

... More
SIGNAGE WORK

-

-

-

... More
Laser Cut Acrylic Letters with Stain less Steel sides along with Korean Led Lights, Letters will be directly fixed over the Main Facade. 8 Feet by 4 Feet

32

-

-

... More
Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back. 4 Inch18 Inch by

51

-

-

... More
Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required.4 Feet by 4 Feet

192

-

-

... More
Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required.2 Feet by 2 Feet

16

-

-

... More
Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required.3 Feet by 1 Feet

48

-

-

... More
Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.4 Feet by 2 Feet

296

-

-

... More
Backlit Acrylic Box Lit with Korean Led.2 Feet by 1 Feet

20

-

-

... More
SAV on the Glass.9 Inch Dia

20

-

-

... More
Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.4 Feet by 3 Feet

12

-

-

... More
Add 18% GST

18

-

-

... More
Add 1% Labour cess 1%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.