State Building Construction Corporation Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

State Building Construction Corporation Limited - JSBCC Tender

Works
Eprocure
Opening Date11 Dec 2024
Closing Date23 Dec 2024
Tender Amount₹ 2,66,64,447 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.

23.17

-

-

... More
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.

36.88

-

-

... More
Providing designation 125 mm thick reinforced designation 75 A brick work in C.M (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials , scafolding, raking out joints to 15 mm depth, curing, taxes and royalty ( but excluding the cost of reinforcement) all complete as per building specification and direction of E/l.

6.6

-

-

... More
Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

187.91

-

-

... More
Providing 112mm thick reinforced designation 100A brickwork fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including the cost of screening carriage of material scaffolfing raking out joint to 15mm depth curing taxes and royalty (but excluding the cost of reinforcement ) all complete as per building specification and direction of E/I.

26.43

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

41.78

-

-

... More
1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

3.92

-

-

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

18.3

-

-

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

90

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

102.42

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

43.59

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

243.76

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

119.44

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

939.14

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

1190.96

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

485.1

-

-

... More
Stairs, (excluding landings)

95.42

-

-

... More
Weather shade, Chajjas, corbels etc., including edge

35.11

-

-

... More
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.

19.53

-

-

... More
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL).

13.93

-

-

... More
Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l.

-

-

-

... More
(a) 10mm TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL).

12.18

-

-

... More
(b) 12mm TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL).

12.18

-

-

... More
(c) 16mm TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL).

21.5

-

-

... More
Providing Tor steel reinforcement of 20mm, 25mm, 28 mm, 32mm dia. bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l.

12.18

-

-

... More
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)

198.72

-

-

... More
Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.

22.77

-

-

... More
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.

451

-

-

... More
Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curring, taxes and royalty all complete as per building specification and direction of E/l.

10.35

-

-

... More
Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 Coarse sand0, jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with wite cement and matching pigments etc, complete Size of tiles 600 x 600 mm.

493.4

-

-

... More
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

65.76

-

-

... More
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

2191.88

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

778.53

-

-

... More
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l.

65.76

-

-

... More
Extra of plaster work over exterior surface for each consecutive floor above above first floor including cost of scaffolding etc. All complete as per direction of E/I.

2389.02

-

-

... More
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.

1775.9

-

-

... More
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification)

11.04

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.

11.04

-

-

... More
Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.

200

-

-

... More
Water proofing for old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flextble material brush, roller or spray for water proofing coating per manufacturer Specifications with following steps :-(a)surface preparation .-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing (loose paint / coating, and cement laitance by cleaning with compressed air water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage. On identification of seepage cement grouting to be done with non shrink expanding admixture of Sika India Pvt.L.td.) MYK Schomberg / Dr Fixiti/ Fosroc or equivallent. Providing and reparing of all Corner and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150Mrn X 150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic pc?' lymer of Sika/ Fosroc/MYK Schomberg/Dr 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent.,Befor 'Chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar-including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)lst Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitiot.is material on surface saturated dry roof and inside wall of Parapet.Wall upto 600 mm by brush or roller . After 1st coat of application , 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat shOUld be applied @1.50 kg/Sqmt/coat. For the purpose of measurer-11609-1'e entire treated surface will be measured." (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified read to use, flexible cementtiOus material right angle to the 1st. coat over the glass fibre laid surface: 2nd coat-,should be applied @ 0.7 Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:- Sika Topseal 109hi / Fosroc Brushbond RFXI Dr. Fixit Pidiffin 2K / MYK Aquafin TG . Product Performance - Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder - Density 1.6 kg/I (mixed density) at +27°C Tensile Strength -2 Nimm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Siren th -2 f\l/mm2 concrete failure Accordin' to ISO4624) Slant-Shear Bond Strength -4 Nimm2 (According to FIP 5.15) Elongation at Break -35% Without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) )Protection of treated surface with PCG :- The treated surface should be covered with 25mm/50mm F'CC of M-20 grade (1.1.5:3). with proper slope ( 1:120) towards the rain outlets in alternate panels of 2 mt x 2 mt keeping 6 rnm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 co of 100 ml per bag of of cement to be added in the screed concreie(paid separately.for this items).All corners shall be chamfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed prorSeqswith ridti:corict'ete and the peripheral mouth to be sealed with,moisture insensitive epoxy putty of. Sika India .Pvt.Ltd. / MYK Schornbefg /Dr Fixit/Fosroc .For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with POlysulphide Sealant.(Paid Separately). Be d - Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc . Warranty for five years.

492.78

-

-

... More
Covering of treated surface with PCC :-providing 25 mm thick Cement Concrete M20 (1:1:5:3) maintaining slope in alternate 2 mt x 2mt panels With approved quality of stone chips of 20mm to 6 mm size graded and Cleaned sand of F.M.2.5 to 3 including screening, shuttering, and mixing Cement concrete in mixer with admixture of integral water proofing and Placing in position, striking curing, taxes and royalty all complete as per Building specification and direction of E/I. Panels that has been left should Be casted next day. There should be 6 mm gap between panels .brand- Sika _ plastocrate plus, MYK proof WP 10, Fosroc- Conplast X 421 ic Dr Fixit Pidiproof LM+

492.78

-

-

... More
Providing and mixing liquid integral water proffing compound in conctrete of plaster as manufacturer specification and as per direction of engineer in charge. Brand. Sika plastocrate plus, MYK proff WP 10, Fosroc-Conplast x 4211C, Dr.Fixit, Pidiproff LW+ or Equivalent

3698

-

-

... More
Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysuiphide Sealant (Porin.g Grade)as per drawings and technical specificationsi6nd direction of E in Charge. (with 18% GST) B rand Sika Polysulphide, Fosrpc-Thioflex 600 Dr. Fixit Pidiseal PS(42P. MY K Seal PS or Euivalent.

1642.7

-

-

... More
Cost of Driling 200mm x 165mm x 125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.

-

-

-

... More
(a) From 0.00 M to 50.00 M below G.L.

75

-

-

... More
(b) From 51.0 M to125.00 M

100

-

-

... More
Supplying submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 metre submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP

1

-

-

... More
Supplying Full automatic star selta starter to operate induction motor working on 415v 3phase 50hz with no coil. Over load element , On _OFF push buttom with necessary materials and connection to Supply etc complete starter with original sheel steel encloser as per 3914. F.A.S.D starter

1

-

-

... More
Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004

115

-

-

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade

2.16

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

81.13

-

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face# 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 TS / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

29.44

-

-

... More
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge.

20.4

-

-

... More
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer- n-charge, manufacturer’s specification & drawing. 30 mm thick pre laminated PVC door shutters

20.4

-

-

... More
Supplying and fixxing rolling Shutters of approved make, made of required size M.s. laths, interlocked together through their entire lenth and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-part 1 and M.S.top cover of required thickness for rolling shutters.

-

-

-

... More
80x1.25 mm M.S. laths with 1.25 mm thick top cover

9.6

-

-

... More
Providind and fixing ball bearing for rolling shutters.

9.6

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:Profile C Fixing with adjustable lugs with split end tail to each jamb

32.4

-

-

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

60

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

601.99

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

385.58

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

10.68

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.

16.57

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
75 mm diameter

95

-

-

... More
110 mm diameter

205.8

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler 75 mm

8

-

-

... More
Coupler 110 mm each

8

-

-

... More
Single pushfit Coupler 75 mm

8

-

-

... More
Single pushfit Coupler 110 mm

8

-

-

... More
Single tee with door 75x75x75 mm

8

-

-

... More
Single tee with door 110x110x110 mm

8

-

-

... More
Single tee without door 75x75x75 mm

8

-

-

... More
Single tee without doo 110x110x110 mm

8

-

-

... More
Bend 87.5° 75 mm bend

8

-

-

... More
Bend 87.5° 110 mm bend

209.6

-

-

... More
Shoe (Plain) 75 mm Shoe each

8

-

-

... More
Shoe (Plain) 110 mm Shoe

209.6

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

101

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1194.51

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

2970.42

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

26.98

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

269.75

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

4

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia

8

-

-

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia

4

-

-

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

4

-

-

... More
Providing and placing on terrace (at all floo levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and marking necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank.

5000

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore

8

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore

8

-

-

... More
Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.

4

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore

16

-

-

... More
Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole

16

-

-

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

4

-

-

... More
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length

16

-

-

... More
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 gms

16

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc

-

-

-

... More
15 mm nominal dia Pipes

12

-

-

... More
20 mm nominal dia Pipes

40

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work

-

-

-

... More
25 mm nominal dia Pipes

134.4

-

-

... More
32 mm nominal dia Pipes

140

-

-

... More
40 mm nominal dia Pipes

145

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe

115

-

-

... More
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg

3

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron

30.96

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)

30.96

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)

10.32

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

120.47

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia

25

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia

25

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

4.91

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

4.91

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

2

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia

2

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp

2

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.

365.18

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per theapproved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

86.95

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted floatglass 6 mm thick substrate with reflective soft coating on face # 2, + 12 mm Airgap + 6 mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

86.95

-

-

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in Charge.

21.74

-

-

... More
Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I

-

-

-

356.19

-

-

... More
Aggregate

446.61

-

-

... More
Stone Metal

9.81

-

-

47.72

-

-

... More
Fly Ash Brick

12.07

-

-

... More
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., "p" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.(A) 580 mm long (c) with 10.0 lit. low level P.V.C. cistern

4

-

-

... More
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With "P" trap (b)10 lit. low level PVC cistern

4

-

-

... More
Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of Hindustan "Parry" or any other approved I.S.S. Make with 5 liters capacity C.I. Automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. bracket, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C./Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I. (a) Flat back or standing corner (600mmX350mm)

4

-

-

... More
Supplylng, fitting and fixing the following items complete with all materials as per specification and direction of E/1. : C.P. brass towel rail 20mmX600mm with bracket container

4

-

-

... More
Supplying, materrials and labour for constructing inspection chamber of designation class 75B brick size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.

14

-

-

... More
Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

1266

-

-

... More
Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.

-

-

-

... More
2x1.5 Sqmm + 1x1.5 sqmm earth wire for separate 3 pin 5A sockets

1292

-

-

... More
2x2.5 Sqmm + 1x2.5 sqmm earth wire for switch board

440

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire SPN lighting DBs

70

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

40

-

-

... More
4x10 Sqmm + 2x6 sqmm earth wire

70

-

-

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

40

-

-

... More
Point wirring in PVC conduit, with Modular type switch :- Wiring for Light point/fan point/exaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in Surface/ recessed PVC conduit, with modular type switch , Modular plate, suitable G.I boxes etc. as required .Group-C

232

-

-

... More
SIF PVC conduit :- Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

360

-

-

130

-

-

... More
S/F Modular Type switch/ socket:-Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

-

-

-

... More
5/6 A switch one way switch

22

-

-

... More
5/6 amps, 3 pin Socket outlet socket outlet

22

-

-

... More
S/F Modular boxes, base & cover plate - Supplying and fixing following size/modules G.I. box along with modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
1 or 2 module (78mm x 78mm x 45mm)

68

-

-

... More
4/5 module (78mm x l40mm x 50mm)

36

-

-

... More
8/9 module (78mm x 230mm x 60mm)

4

-

-

... More
12 module (135mm x 205mm x 60mm)

4

-

-

... More
S/F Modular type switch/ socket :-Supplying and fixing of following modular switch / soket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
Bell push

2

-

-

... More
S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required . (For light plugs to be used in non residential buildings)

68

-

-

... More
S/F power plug point with Modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface of in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required. (For light plugs to be used in non residential buildings)

36

-

-

... More
S/F ceiling rose :- supplying and fxing 2 pin 5 amp. Ceiling rose on the existing junction box/ wooen block including connection etc. as required .

115

-

-

... More
ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.

4

-

-

... More
S/F T. P. MCB DB :-Supplying and fixing the follwing way Three Pole pole and Neutral Sheet steel M.C.B distribution board, 415 volts in recess, completed with tinned copper busbar, neutral bus bar, earth bus bar, din bar, hinged front acrylic cover from MCB Knob detachable gland plate, interconnection including earthing etc. as required(without MCB/RCCB/Isolator).

-

-

-

... More
4 way(4+12) Double door Horizontal type

6

-

-

... More
S/F 'C' series SP MCB: Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, "C" curve, miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.

-

-

-

... More
6/32 amps, Single pole

72

-

-

... More
40 amps, DP

5

-

-

... More
50/63 amps, TPN

9

-

-

... More
S/F MCCB in cubical panel board :- Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 25-100 amps, 16 KA, fxed thermal setting

2

-

-

... More
S/F VERTICAL TYPE T.P. MCB DB :- Supplying and fixing of following ways surface/ recess mounting vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected,duly powder painted, inclusive of 200 amps tinned copper bus bar,common neutral link, earth bar, din bar for mounting MCB's (but withoutMCB's and incomer ) as required . (Nobe : Vertical type MCB TPDB isnormally used where 3 phase outleb are required.)

-

-

-

... More
4 way(8+12) Double door, Vertical type

2

-

-

... More
Earthing with copper earth plate 600mrn x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as Required.

8

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

50

-

-

... More
Providing and fxing 25mm x 5mm G.I. strip on surface or in recess for connection etc. as required.

30

-

-

... More
Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing etc. as required.

90

-

-

... More
Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB, "C" curve including connections, painting etc. as required.

26

-

-

... More
Supplyind and making end termination with brass compression gland and Aluminium lugs for flowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3.5Cx35 Sq mm (32mm)

2

-

-

... More
S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC,50Hz. Luminarie shall be confirm to IS:10322 part-5/section-5 and shall be complete with all neccssary accessories as required-90/100W LED Flood light

4

-

-

... More
S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722 with all neccssary accessories as required

32

-

-

... More
S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722with all neccssary accessories as required-18/20W LED Round Down light

152

-

-

... More
S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50H2, single phase supply etc. complete as required.-20/22W LED Tube light

4

-

-

... More
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not excecding 35 sq mm directr in ground including excavation and refilling the trench etc as rquired, but excluding sand cushioning and prolective covering.

110

-

-

... More
Supplying of PVC/XLPE insulated PVC sheathed heavy duty, armoured electrical cable with aluminiumconductor forworking voltage up to and including 1100 volts. (Conforms to IS:1554,part-1):35 sq. mm,3.5 core

120

-

-

... More
Supply of Metal Exhaust Fan 12"(300mm): Supply of 12"(300mm), 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required.

4

-

-

... More
Supply of Wallmounted Fan: Supply of 16"(400mm), 230V AC wall/cabin fan including fixing the bracket, making , connection testing, commissioning etc as required.

40

-

-

... More
Split type AC 1.5T, 5 star: Supply, installation, commissioning of split type Inverter AC 1.50T capacity, 5 star rating as per IS-1391, part-II.

26

-

-

... More
Copper tube of size( 1/4)" for split AC unit 1/1.5/2/3 tr capacity including nitride rubber insulation

130

-

-

... More
Drain pipe for split AC

182

-

-

... More
3 core PVC insulated PVC sheathed copper conductor flat submersible cable. Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:7098 3 Core 4 Sq mm. Copper wire

130

-

-

... More
TOTAL AMOUNT FOR SCHEDULE ITEMS (A)

-

-

-

... More
Non -Scheduled item

-

-

-

... More
Supplying and PlacingWriting Board 1200mm x 3000mm Purpose : Writing Mounting type : Wall mounts Frame (All round framing) : With, Writing board placed Top Surface materials (Usedfor white board surface) : Porcelain Top surface material thickness : 0.7 mm to 0.8 mm Frame material :Anodized extruded aluminum alloy hollow section conforming to IS 733

4

-

-

... More
Supplying & Placing Executive Table, Particle Board Top W1600 X D1600 X H750 Structure /Frame of table Gable end and modesty panel The type of Storage provided One side E.R.U unit Keyboard tray Not provided Footrest Not Provided Tabletop Material Commercial Block Board MR Grade Conforming to IS 1659 Thickness of table top material (± 1 mm) 36 mm Gable end material Prelaminated particles board(wood product) of grade II type III of IS 12823/Latest The thickness of the gable end NA Modesty panel material Perforated MS sheet The thickness of the modesty panel material 0.9 mm (for metal sheet) Leg Material Mild Steel (MS) ERW The thickness of the Leg material 1.2 mm Width of tabletop ±10 mm 1500 mm Depth of table ±10 mm 915 mm Height of table ±10 mm 750 mm Size (L x W) /diameter of leg material ± 5 mm NA ERU unit consists of 3 drawers Total Number of drawers /storage in Pedestal units Four drawers Table top finish Laminate in color with swede finish 0.6-0.8mm thickness of type S, F or P having index no.3.2.3 conforming to IS 2046/Latest with having balancing laminate of 0.5mm thick on another side Tabletop shade Oxford cherry Table /ERU /Pedestal Panel Plain Side Edge to be banded with PVC tape 2 mm thick with the help of hot melt glue

2

-

-

... More
Supplying & Placing Medium Back Chair, Chrome Plated Pipe PU Arm, Gas Lift, Chrome Base, Mesh Back & Seat Net Tapestry Chair mechanism Tilt working with torsion bar mechanism Type of locking Upright locking Number of arm movement N.A Pedestal Base Chrome plated MS Armrest Material Polypropylene Seat material Pressed and moulded with PU foam Backrest is made of One piece hot pressed plywood with PU foam Density of PU foam used in seat KG per Cu Meter (± 3) 40 Density of PU foam used in backrest in KG per Cu Meter (±3) 40 Backrest upholstered with 100% Polyester Fabric Seat upholstered with 100% polyester fabric GSM/Thickness of fabric ±5%(Gram/Square meter) 220 gram Overall width (±10 mm) 650 mm Backrest Height ±15 mm 690 mm Backrest Width ±10 mm 440 mm Seat Height ±10 mm 440 mm Seat Width ±10 mm 480 mm Seat Depth ±10 mm 480 mm Thickness of MS Plate Joining the under structure with Seat 5 mm Thickness of Plywood used in Seat ±1(mm) 12 mm Thickness of Plywood used in Backrest ± 1(mm) 12 mm Pedestal Size (Diameter in mm) ±10 mm 600 mm Thickness of Polyurethane Foam Used in Seat in mm (±2 mm) 30 mm Thickness of Polyurethane Foam Used in Backrest in mm((±2 mm) 35 mm

2

-

-

... More
Supplying & Placing Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand Leatherette Tapestry Chair Type Non-Revolving and Non-Tilting chair with Armrest Chair frame type Legs Armrest type Continuous armrest Seat type Padded Backrest type Padded Frame Material Configuration Two Piece Frame material Stainless Steel (SS 202) Seat material Moulded Plywood Seat material thickness 30 mm Density of Polyurethane foam used in seat (±2 Kg/Cub Meter) 40 Seat upholstered with PU sheet GSM of seat cover (± 3 GSM) 390 GSM Backrest material Moulded Plywood Density of Polyurethane foam used in Backrest ( ±2 Kg/Cub Meter) 32 Backrest upholstered with PU sheet Seat Depth (± 5 mm) 430 mm Seat Width (± 5 mm) 460 mm Seat height from floor surface (± 5 mm) 475 mm Backrest width (± 5 mm) 450 mm Backrest height from seat (± 5 mm) 460 mm Paint Type Chrome Paint Polish Type N.A Colour of Paint N.A Availability of Test Report from Central Govt/NABL/ILAC accredited lab to prove the conformity of product to the Specification Yes Test reports to be furnished to buyer on demand Yes

6

-

-

... More
Supplying & Placing workstation table in completely knock down conditions with an overall size 4000mm X 1260mm X 1200mm that is to be assembled at site. The worktop shall be made up of back to back 25mm thick Pre-laminated particle board of grade II of IS 12823 with approved laminate and finish as per approved shade. The top profile shall be in sharing base rectangle shape and the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 550mm X 280mm. The trey shall be operated on keyboard channel. The top shall be supported on particle board base gable end. The end wall of the top shall be topped by gable end. It should be made up of 25mm thick Pre-laminated particle board and the profile shall be in linear shape with appropriate PVC edge banding. The workstation shall have panel based partition of 60 mm thick with overall height 1200mm. The partition shall be linear in profile and provided in front side of user. The top trim, top bar, mid bar, vertical bar, raceway, skirting shall be made up of aluminium extrusions (pre-treated) and duly powder coated with 40-60µ thick. The trims shall have the size 60mm X 19mm with 1.5mm thick covered with Die cast end caps on joints 2 ways, 3 ways & 4 ways (L-cover for corner, T-cover for middle section wherever required). The aluminium raceway shall be situated below the worktop with an overall size 116mm(H) X 60mm(D) with 1.4 mm cover thickness and 2mm back thickness as per requirement of inlaying the electrical management and carrying the wire horizontally. The exposed vertical and horizontal faces of the frames shall be snap fitted with trims. There shall be soft-board (with fabric) provided at front of the user. Laminated bottom tile shall be situated below the work top. The Partition shall have concealed wire management capabilities and should be engaged for responsive and safe operations of power, telecommunications and data (LAN) and has separate components for electrical, data and telephone cables having adequate capability of both the vertical and horizontal wire movements. Slots/cut-outs should be given on raceways to fix all electrical and data points. Zinc coated small top support brackets shall be fixed on the partition for table top support. To protect the wall from kicks, abrasion and serve as a decorative moulding, skirting shall be situated at bottom. Adjustable leveller shoe shall be provided at bottom of the partition to avoid scratches on the floor. Fixed pedestal shall be provided with an overall size 400mm X 450mm X 725mm. The pedestal shall be made up of Pre-laminated particle board of grade II of IS 12823. Pedestal side, back, top, facia shall be 18mm thick and drawer base shall be 9mm thick. The pedestal shall have 4 nos. of drawer having same size. The drawer shall be operated with SS handle and easily close & open with the assistance of roller channel to enable smooth operation. The drawer shall have central locking mechanism in which all the drawer shall be synchronized locked with one single key. To protect the wall from kicks, abrasion and serve as a decorative moulding, skirting shall be provided at bottom. A nylon castor based CPU unit shall be provided with an overall size 470mm X 286mm with 18mm thick Pre-laminated particle board. The manufacturer shall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007, BIFMA membership and AIOTA certification. The board used should meet International Standard of quality, Indian standard IS 12823 grade II should meet long time load bending, screw-withdrawal strength, modulus of rupture and modulus of elasticity bending tested as per IS 2380.

12

-

-

... More
Supplying & Placing Conference table in completely knock down conditions with an overall size 3600mm X 1200mm X 750mm that is to be assembled at site. The construction of the main table shall be free standing structure constructed with the help of minifix dowels and pins. The table top shall have the size 1800mm X 1200mm made up of 2 nos. of 50mm thick pre-laminated particle board of grade II of IS 12823 with one side laminate and finish as per approved shade. The table top profile shall be in rectangle shape and the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edgebander machine at 200 0C. The table top shall be supported by particle board base gable end. The end wall of the table on the side shall be topped by gable end. The gable end shall have the size 1050mm X 695mm with 49mm thick and 100mm X 695mm with 18mm thick. The gable end shall be made up of Pre-laminated particle board with appropriate PVC edge banding and covered both side by Aluminium section. The table shall be clad with 18mm thick modesty panel which provide structural support for the desk. The modesty panel shall have an overall size 1200mm X 400mm with 18mm thick pre-laminated particle board connected with both end. There shall be buffers provided to avoid scratches on the floor. The table connections have to be made in such a way that no gap should be seen in between. The manufacturershall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007, BIFMA membership and AIOTA certification.The board used should meet International Standard of quality, Indian standard IS 12823 grade II should meet long time load bending, screw-withdrawal strength, modulus of rupture and modulus of elasticity bending tested as per IS 2380.

8

-

-

... More
Supplying & Placing 3 Seater Sofa With SS Arms & Legs, Perforated Seat & Back, Powder Coated Beam Size in mm - 1750(L) X 710(D) X 755(H) SS 304 Style with arm and backrest Seating Capacity (Nos) 3 Material of Main Frame SS 304 Material of Seat and Backrest SS 304 Material of Arms SS 304 Material of Legs SS 304 Material of Side Bar Bracket made up of chrome plated solid steel Overall Length in mm (±10 mm) 1800 Overall Depth in mm ( ±5 mm) 665 Overall Height in mm (±5 mm) 760 Conforming to International Standard for Public Seating (*BIFMA X 5 dot 4 or equvalent) YES All steel component to be epoxy powder coated 60 micron thick

4

-

-

... More
Supplying & Placing Revolving Stool, Cushioned Top, Stainless Steel Structure, Height Adjustable (510mm - 690mm) Adjustable Height No Normal Height (mm) 510 Min. Height (mm) 510 Max. height (mm) 690 Stool Top base Thickness (mm) 1.6 Cushioning in the stool Top with Cushion No of Legs in the under structure 4 Foot rest Without Material of Top Stainless Steel Painting Powder coating Type of Stool Revolving Back rest Without

48

-

-

... More
Supplying & Placing Steel Almirah, 2 Doors, 4 Adjustable Shelf, Thickness 0.8mm W900 X D 450 X H1830Geeken Technical specification of Almirah steel Generally conforming to BIS specification IS: 3312:2021 (with latest amendment) Type of Almirah steel Almirah Steel shelving cabinets Number of door 2 Number of drawers required No Drawer Number of shelves 4 Colour of finish As per Buyer’s Requirement (to be indicated during bid creation) Steel sheet material CRCA sheets conforming to grade CRI of IS 513(part-1):2016 (with latest amendment) Sheet rounds and flats Conforming to grade E250 of IS 2062 Almirah height(excluding the height of pedestal) ± 5 mm 1980 mm Almirah width ± 5 mm 900 mm Almirah depth ± 5 mm 450 mm Side sheet thickness 0.8 mm Back sheet thickness 0.8 mm Top sheet thickness 0.8 mm Bottom sheet thickness 1 mm Shelves sheet thickness 0.9 mm Shelves supporting bracket thickness 1.6 mm Hinges sheet thickness 1.25 mm(double folded) Hanging rod wall thickness N.A Mirror frame sheet thickness N.A Mirror frame border width N.A Width of stiffener N.A Stiffener sheet thickness N.A Number of glass sheet fixed N.A Handle size 12 cm Steel Almirah lock/locker lock Six lever lock Material of lock Brass and Steel finish Finish coat with enamels Conforming to IS:151 Powder coating Conforming to IS: 13871

12

-

-

... More
Supplying & Placing Drinking water palteform Approximate External Dimensions (WXDXH) 750 x 690 x 1420 mm Input Voltage 230 V AC (50 Hz) Power Rating (Max) 850 ± 10% Water Storage Tank Capacity 120 Litre Cooling Capacity 60 LPH Output Water Temperature 15°C±1°C Refrigerant HFC R 134 a Thermal Insulation for Storage Tank PUF No. of Faucets 3 Cold No. of Stages for Filter cum Purifier 7 Active Copper Zinc Booster Yes % of Purified Water Recovery 25% % Rejection of TDS 90% (Approx) Permeate (Purified Water) Production Capacity 50 LPH Storage Tank & Drain Tray Material SS 304 Outer Body Material rest CRCA Powder Coated Steel Front Panel SS 304 and Type of Product Construction Concealed Type of Installation Indoor Net Weight 92 Kg Operating Input Water Pressure 1.0 to 2.0 Kg/cm² Operating Temperature 10°C to 40°C Recommended Total Dissolved Solids in Input Water(TDS) 500 to 2000 ppm.(Max) Recommended Hardness in Input Water 300 ppm(Max) Recommended pH of Input Water 6.5 to 8.5 Allowable Chlorine Input Water 0.2 ppm (Max) Allowable Iron in Input Water 0.3 ppm (Max) Turbidity 5 NTU

1

-

-

... More
Add GST 18 %

18

-

-

... More
Add Labour cess 1%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.