State Building Construction Corporation Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

State Building Construction Corporation Limited - JSBCC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 May 2023
Closing Date31 May 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)

348.63

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

77.15

-

-

... More
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

1.87

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)

0.84

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)

3.81

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

3.95

-

-

... More
Providing and laying in position machine bached and machine mixed design mix M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excuding the cost cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.

-

-

-

... More
All works upto plinth level

121

-

-

... More
All works above plinth level upto floor V level

306.17

-

-

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein.

154.54

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete

93.08

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform

1256.82

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)

3.94

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 MTR.re or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

1208.46

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers

917.19

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts

536.17

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases

26.8

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

247.21

-

-

... More
Extra for shuttering in circular work (20% of respective centring and shuttering items )

100

-

-

... More
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))

17.86

-

-

... More
Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))

12.14

-

-

... More
Providing Tor steel reinforcement of 12mm. to 32mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))

29.63

-

-

... More
Providing designation 75A work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.

15.21

-

-

... More
Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.

14.26

-

-

... More
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.

20.11

-

-

... More
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.

180.38

-

-

... More
Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.

1115.81

-

-

... More
Extra for brick work for each consecutive floor above first floor including watering & scaffolding all complete as per direction of E/I

67.02

-

-

... More
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary

1115.81

-

-

... More
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.

573.77

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:

-

-

-

... More
Profile B.Fixing with adjustable lugs with split end tail to each jamb

297.65

-

-

... More
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.

144.45

-

-

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

144.45

-

-

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :50x12 mm

380.9

-

-

... More
Providing, fitting and fixing oxidised iron fitting of approved quality and make to door and window all complete as per building specification and direction of E/I necessary screws etc. complete.300 mm sliding door bolt

69

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.

69

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

46

-

-

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

46

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness

12

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1377

-

-

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

-

-

-

... More
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1672.95

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes

66.92

-

-

... More
Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.

864

-

-

... More
providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm

551.99

-

-

... More
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 SQM

1.2

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

65.07

-

-

... More
Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.

251.92

-

-

... More
Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of lime morter (1:l:1) ( Lime putty : surkhi: coarse sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.

340.14

-

-

... More
Providing and laying 25mm. thick kotah stone riser of steps, skirting and pillers of approved size, texture and colour over 12 mm thick cement morter (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.

60.43

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase

247

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

20

-

-

... More
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-

-

-

-

... More
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.

-

-

-

... More
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.

-

-

-

... More
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured."

-

-

-

... More
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.

-

-

-

... More
The Watqrproofing Brand:*Sila Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.

-

-

-

... More
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)

-

-

-

... More
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems

-

-

-

... More
all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."

-

-

-

... More
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc

187.41

-

-

... More
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr

187.41

-

-

... More
Provrding and filling of Groove between 25 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent

187.41

-

-

... More
Toilet/Kitchen Water proofing:

-

-

-

... More
1) Surface preparation by grinding machine, cleaning , crack filling etc. complete

-

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :

-

-

-

... More
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.

-

-

-

... More
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry

30.73

-

-

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

3232.85

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

1228.05

-

-

... More
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.

93.67

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

3905.06

-

-

... More
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

3708.52

-

-

... More
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 SQM) SQM 57.85

3708.52

-

-

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM

4264.36

-

-

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats

3905.06

-

-

... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats

157.95

-

-

... More
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.

333.5

-

-

... More
Providing 1.5mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I.

93.67

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment For fixed portion @ 6KG/SQM

1092.8

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) For opnable portion @ 6KG/SQM

95.04

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)

66.92

-

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.

176.73

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:

-

-

-

... More
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent biMTR.allic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the periMTR.er for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having

-

-

-

... More
all the performance characteristics etc. all omplete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in SQM. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 SQM from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories

-

-

-

... More
1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing MTR.hod for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing MTR.hod for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing MTR.hod for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing MTR.hod for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing MTR.hod for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

176.73

-

-

... More
Providing, assembling and supplying vision glass panels (SGUs) comprising of hermetically-sealed 6mm insulated glass ( glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The SGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of SGUS Panels in the curtain glazing is included in cost of item No.25.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“

-

-

-

... More
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

176.73

-

-

... More
Making of GFRC Screen (35mm thick inside-50 mm thick border) as per your design. As per the design of architects. Including fixing to wall in cement:sand mortar all in perfect line and length complete

84.3

-

-

... More
BRICK WORK (UP TO 8KM)

13.02

-

-

... More
SAND (UPTO 18KM)

358.68

-

-

... More
CHIPS (UPTO 22KM)

85.82

-

-

... More
STONE METAL (UP TO 22KM )

4.12

-

-

... More
Supply, Installation & testing, Commissioning and Handover Machine Room Less Lift with a speed 0.75 m/s Serving All Floor as per Drawings. Comlete SS Finish and as per CPWD Specs. Passenger/stretcher lift (1020 kg.)

1

-

-

... More
CHILDREN PLAY EQUIPMENT

-

-

-

... More
Supplying and fixing MULTI PLAY SYSTEM 11/2/2017- Multi play system which involves activities like sliding, climbing, exploring, balancing, crawling etc. 6. 8m, x 5. 5 m ( 2 m high) all complete as per direction of engineer-in-charge

1

-

-

... More
Supplying and fixing MULTI SEATER SEE SAW: a). Spring loaded see saw b). Rotational Moulded seat with Anit skid Surface c). Handles for perfect grip , size 1.5m X 4m , all complete as per direction of engineer-in-charge

1

-

-

... More
Supplying and fixing DOUBLE ARC SWING: a).Swings manufactured in combination of Rubber belt & PVC coated chain b).Bearings provided for Swing moment size 3.2m X 1.5m , all complete as per direction of engineer-in-charge

1

-

-

... More
Excavation in soil using Hydraulic Excavator CK 90 and Tippers with disposal up to 1000 meters. (excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including setting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within al lifts and lead up to 1000m)

150

-

-

... More
Granular sub-base with close graded material (Table 400-1) - By mix in place method (construction of granular sub base by providing close graded material, spreading in uniform layers with motor graded in prepared surface, mixing by mix in place method with rotator ta OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401)

90

-

-

... More
Dry Lean cement concrete Sub-Base (Construction of Dry Lean Cement Concrete Sub-Base over a prepared sub grade with coarse and fine aggregate confirming to IS:383, the size of coarse aggregate not exceeding 25mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10MPa at 7 days, mixed in batching plant, transported to site laid with a paver with electronic sensor, compacting with 8-10 tones vibratory roller finishing and curing)

104.18

-

-

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )

90

-

-

... More
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 Using Concrete Mixer

150

-

-

... More
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete.New work (Two or more coats)

600

-

-

... More
HORTICULTURE WORK

-

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).

22.5

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)

-

-

-

... More
Screened through sieve of IS designation 20 mm

3.38

-

-

... More
Screened through sieve of IS designation 16 mm

7.88

-

-

... More
Screened through sieve of IS designation 4.75 mm

11.25

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage up to 5.0 km (cattle manure measured in stacks will reduced by 8% for Payment)

22.5

-

-

... More
PREPARATION WORKS

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)

45

-

-

... More
Rough dressing the trenched ground including breaking clods

150

-

-

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation

150

-

-

... More
Fine dressing of the ground

150

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge

45

-

-

... More
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).

45

-

-

... More
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts

150

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50.0 m, lift up to 1.50 m complete (cost of sludge, manure or extra earth to be paid for separately)

45

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm diameter and 60 cm deep

30

-

-

... More
PLANTING WORKS

-

-

-

... More
Grassing with selection No1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately) In rows 5 cm apart in both directions

150

-

-

... More
MAINTENANCE WORKS

-

-

-

... More
Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately)

150

-

-

... More
SHRUBS

-

-

-

... More
Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge.

30

-

-

... More
Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge.

30

-

-

... More
Providing and stacking of Calliandra, emarginata of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge

30

-

-

... More
Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy as per direction of the officer-in-charge.

30

-

-

... More
Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.

30

-

-

... More
Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge

30

-

-

... More
Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge.

30

-

-

... More
DUSTBIN

-

-

-

... More
70 Ltr. Fibre-reinforced plastic (FRP) Rabbit dustbin

5

-

-

... More
60 Ltr. Fibre-reinforced plastic (FRP) Penguin dustbi

5

-

-

... More
50 Ltr. Fibre-reinforced plastic (FRP) Frog dustbin

10

-

-

... More
50 Ltr. Fibre-reinforced plastic (FRP) Dog dustbin

10

-

-

... More
Labour for laying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leak, proof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complete as per specification and direction of E/I. 150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L.

120

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia

30

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge

3.34

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge

3.34

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge

3.34

-

-

... More
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area

30

-

-

... More
ELECTRICAL WORK POINT WIRING & ACCESSORIES

-

-

-

... More
WIRING IN MS/ PVC CONDUIT

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

172

-

-

... More
Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

167

-

-

... More
Wiring for 6 Amp Power point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, and 5 pin socket and modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

55

-

-

... More
Wiring for 6/16 Amp Power point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, and 5 pin socket and modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

32

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

70

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

300

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.

-

-

-

... More
FOR LIGHTING CIRCUIT / SUB MAIN WIRING

-

-

-

... More
2x2.5 sq mm + 1x2.5 sq mm earth wire

1200

-

-

... More
2x4 sq mm + 1x2.5 sq mm earth wire

20

-

-

... More
Supplying and fixing of following sizes of pvc conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25mm dia

700

-

-

... More
32mm dia

100

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.

7

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

5

-

-

... More
LIGHTING FIXTURES & FANS

-

-

-

... More
Supply, Installation & testing of following type LED light fixtures, on wall/ Ceiling including all fixing accessories, etc complete as required. The LED shall be complete with driver all prewired upto the terminal block. All fixtures shall be supplied with lamps.

-

-

-

... More
15/16w LED Round Down light

245

-

-

... More
6/7W LED Round Down light

30

-

-

... More
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of ndard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire suitable for 230V 50H2, single phase supply etc. complete as required.l200mm (48") Ceiling Fan

44

-

-

... More
Bulk head fitting with 9/10 Watt CFLILED.

4

-

-

... More
Supply, Installation & testing of following 1400 RPM,400 mm ɸ exhaust fan with MS louvers (Heavy Duty) Exhaust fan suitable for single phase 230/240V, AC Supply complete with motor mounting brackets, all accessories complete. As required.

8

-

-

... More
SUB HEAD - III : MV DISTRIBUTION BOARDS

-

-

-

... More
MCB DISTRIBUTION BOARDS

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).8 way, Double door

4

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator),8 way (4 + 24), Double door

4

-

-

... More
Supplying and finishing 5 amps to 32 amps rating, 240 volts 'C' series, miniature circuit breaker suitable for inductive and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

120

-

-

... More
Triple pole

2

-

-

... More
Supplying and fixing following rating, four pole, 415 V, isolator the existing MCB DB complete with connections, testing and in commissioning etc. as required.

-

-

-

... More
40 A

2

-

-

... More
63 A

2

-

-

... More
Supplying and fixing following rating ,double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 A

2

-

-

... More
63 A

2

-

-

... More
Supplying and fixing DP sheet steel enclosure on surface / recess along with 25/32 A , 240 V "C" curve DP MCB and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
Supplying and fixing TP sheet steel enclosure on surface / recess along with 16/25/32 A , 415 V "C" curve TP MCB and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with testing and commissioning etc. as required.For 8 way, Double door SPN MCBDB

5

-

-

... More
Exit Signage

-

-

-

... More
Emergency Exit Lights as per model Omniex with laser eatched translucent polyacrylic 8mm thick sheet illuminated with the hidden LED strip in Green Colour. The Unit shall be 230 V A.C. & 12 V DC operable & shall be supplied with inbuilt Battery for 30 Min backup, Battery charger complete with hanging/ Mounting arrangements.ll

2

-

-

... More
TELECOMMUNICATION SYSTEM (DATA, TELEPHONE & TV) (CONDUITING & CABLING UPTO SHAFT ONLY)

-

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (Conduiting for Telecommunication System)

-

-

-

... More
25mm dia

100

-

-

... More
32mm dia

50

-

-

... More
UPS SYSTEM

-

-

-

... More
Supply, installation, testing & commissioing of Following rating UPS.(Single Phase) Battery shall be external type with rack and suitable for 30 minute backup on 100% load.Battery to be included in UPS cost.2 KVA UPS.

1

-

-

... More
PLUMBING WORK

-

-

-

... More
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flush pipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I.

-

-

-

... More
(B) 580 mm long

-

-

-

... More
(c) With 10lit. low level PVC cistern

18

-

-

... More
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (ii) E.W.C with "S" trap (b)10.0 lit. low level P.V.C. cistern

6

-

-

... More
Supplying, fitting and fixing flat back or angular lipped front vitreous white glazed earthern ware urinal of Hindustan "Parry" or any other approved ISS make with 5 ltrs. Capacity C.I. automatic fushing cistern of reliance for any other ISS approved make with all fittings with C.I. or RS brackets standard size G.I. flush pipe with fitting clamps 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 gms. 15mm PVC alkethene pipe 450mm long with brass coupling at both ends and doing plumber points including painting of exposed part with two coats of approved paint over a priming coat of red oxide cutting wall and floor making good the same etc. all complete as per speciifcification and direction of E/I. Flat back or standing corner (600X350mm)

12

-

-

... More
supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.

22

-

-

... More
Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms each 348.60.

22

-

-

... More
Providing and Fixing white glazed vitreous china urinal partitions of approved make including rawl plugs, screws or any other approved device for fixing arrangements, making holes in walls, floors & making good.

2

-

-

... More
Provinding and fixing of CP health faucet with all required aceesseries complete.

20

-

-

... More
Provinding and fixing of CP angle valve with all required aceesseries complete.

60

-

-

... More
Providing and Fixing adjustable type wash basin for handicap toilet complete with brackets, tracks (Model R4140), waste pipes and other accessories complete as required.

2

-

-

... More
Providing and Fixing 2 Nos. support arms and backrest to mounted on the track (vertically and laterally) Model R3548 & 6533) for handicap toilet complete as required. (Make : Presalit - Commander)

2

-

-

... More
Providing and Fixing powder coated steel grab bar.

2

-

-

... More
Providing and fixing of Chromium plaated Two way bib cock including all acesseries and satisfaction to Engineer - in- charge.

20

-

-

... More
Providing and fixing of SS 304 Heavy class grating 125 x 125 mm including all acesseries and satisfaction to Engineer - in- charge.

20

-

-

... More
WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the sameincluding testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
15 mm nominal outer dia Pipes

164.4

-

-

... More
20 mm nominal outer dia Pipes

50

-

-

... More
25 mm nominal outer dia Pipes

45

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
20 mm dia nominal bore

66

-

-

... More
25 mm dia nominal bore

93.5

-

-

... More
32 mm dia nominal bore

55

-

-

... More
40 mm dia nominal bore

-

-

-

... More
Providing and fixing concealed stop cock complete with G.I. fittings including trenching and refilling etc.15 mm dia

15

-

-

... More
Providing and fixing full way lever operated forged brass body quarter turn lever operated ball valve with forged brass hard chrome plated ball, Including necessary fitting, flanges, nut, bolts, gasket, washer union etc. disc & gland packing shall be PTEF tested to 15 Kg/cm pressure.

-

-

-

... More
25 mm dia

8

-

-

... More
32 mm dia

6

-

-

... More
40 mm dia

-

-

-

... More
Providing, jointing and fixing uPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications.

-

-

-

... More
110 mm OD

250

-

-

... More
75 mm OD

88

-

-

... More
63 mm OD

15

-

-

... More
40 mm OD

40

-

-

... More
Providing, fixing and testing of uPVC SWR P or S trap or Multi port Trap including jointing with solvent cement and making good the walls, floors etc., complete of nominal size.110 x 110mm

5

-

-

... More
Providing, fixing and testing of uPVC SWR multi port trap including jointing with solvent cement and making good the walls, floors etc., complete of nominal size.

13

-

-

... More
Providing & fixing 6 mm thick Heavy class SS grating with rim of approved design including setting in floor with cement mortar to match with floor finish as per Architect requirement. 125mm dia

15

-

-

... More
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.

35000

-

-

... More
RAIN WATER PIPES & FITTINGS

-

-

-

... More
Providing, fixing, jointing, testing and commissioning UPVC (Class III) Rain water downtake pipe conforming to IS:4985 cut to required lengths including all necessary fittings and specials.UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting, chases / holes in floors / walls / slab. 160 mm OD

40

-

-

... More
Making rain water khurras with average minimum thickness 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) over PVC sheet 1 m x 1 m x 400 micron, finished with 12 mm plaster in cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement including rounding of edges and finishing of outlet complete in all respects.450 x 450 mm

4

-

-

... More
Providing & fixing of 200X200 MM Heavy class CI Vertical grating approved design to vertical drain pipe including setting in wall with cement mortar as per satifaction of Engineer- in charge.

4

-

-

... More
EXTERNAL DRAINAGE

-

-

-

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter

84

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe

84

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

5

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand graded stone aggregate 20 mm nominal size) finished with a floating: 4 coat of neat cement complete as per standard design :Inside size 450x450 mm and 600 mm deep top slab will be openable

6

-

-

... More
EXTERNAL STORM WATER

-

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
150 mm dia. R.C.C. pipe

82

-

-

... More
250 mm dia. R.C.C. pipe

10

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of RCC. pipes including bed concrete as per standard design :

-

-

-

... More
150 mm diameter RCC Pipe. pipe

82

-

-

... More
250 mm diameter RCC . pipe

10

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I.surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

4

-

-

... More
Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

6

-

-

... More
FIRE HYDRANT SYSTEM

-

-

-

... More
Supply, Installation testing & commissioning of Black Mild Steel Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I (5.85mm thick) including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site including cutting & making good the walls, floors, RCC work etc cutting chases & filling the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) (For Internal/External work). The sleeve / cutout with fire sealent (equivalent to fire wall rating) compound at either end.

-

-

-

... More
25 mm dia

4

-

-

... More
80 mm dia

6

-

-

... More
150 mm dia

17

-

-

... More
Supply and painting for M.S. Pipe with a coat of zinc chromate and two or more coats of compatible synthetic enamel paint of approved colour to give an even shade including surface preparation and cleaning of pipe from all external material.

-

-

-

... More
25 mm dia

4

-

-

... More
80 mm dia

6

-

-

... More
150 mm dia

17

-

-

... More
Providing and fixing Stainless steel single headed ISI marked oblique pattern hydrant landing valves with 80mm dia flanged inlet & 63 mm dia female outlet complete with PVC / rubber cap and GI chain twist release type plug and all accessories as per IS : 5290 Type A including fixing with anchor fasteners and flanged tapping from wet riser and providing pressure gauge with gun metal ball valve complete as required.

2

-

-

... More
Providing & Fixing of 63 mm dia 15 m long percolating flexible hose (RRL- type A) as per IS : 8423. Type A with Stainless steel male & female instantaneous type coupling (IS 903).The hose shall be rated for brust pressure of 35.7 Kg/Sq.cm. The hose shall be tested for flame resistance test in accordance to IS 8423.

4

-

-

... More
Providing & Fixing of standard Gun metal 63 mm dia branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:903) complete.

2

-

-

... More
Providing & Fixing of standard Fireman's Axe with heavy insulated handle conforming to (IS:926).

2

-

-

... More
Providing & Fixing of wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with stainless steel shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall by means of 120 mm x 100 mm long fasteners, bolts and nuts including painting. (For internal hydrant system).

2

-

-

... More
Providing & fixing fire authority approved M.S. fire door (size 900 (L) x 2100 (H) made out of 16 gauge M.S. sheet angle frame capable of accommodating fire hose reel, fire hydrant, hose pipe, fittings & accessories. The box shall have single or double glazed front glass door (with 4 mm thick glass) with lock & key arrangement & shall be painted with Fire red as per IS :5, shade No. 536. Drain arrangement shall be provided by Contractor. (FABRICATED)

2

-

-

... More
Providing & Fixing of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers complete. [PN -16 rating(16 kg/cm2 pressure rating)] 150 mm dia

2

-

-

... More
Providing, fixing, testing and commissioning of dual plated Non Return Valve PN 16 rating (16 kg/cm2 pressure rating) conforming to IS :5312 complete with nuts, bolts & washers.150 mm dia

2

-

-

... More
Providing & fixing cast iron single acting air valve with screwed inlet 25 mm dia including Ball valve and all fitting & accessories.

1

-

-

... More
Providing & Fixing of burden type Stainless Steel dial type pressure gauge with brass isolation valve and pipe. Dial Diameter : 150 mm Caliberation : 0-16 Kg/cm2

3

-

-

... More
Providing and fixing brass/bronze lever operated ball valves of full flow with stainless steel ball (AISI 304 and spindle AISI 401) with settling and gland of superior quality and having minimum working pressure of 15 Kg/cm 2.25 mm dia

3

-

-

... More
Providing, fixing, testing & commissioning of Y strainer made from MS body with nuts, bolts etc having filteration area at least 6 times the cross sectional area of the pipe. 150 mm dia

1

-

-

... More
Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with synthetic enamel polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases.Capacity 5 Kg

3

-

-

... More
Providing and fixing water Co2(ISI marked) extinguishers including all accessories as per IS specification. (IS : 940 - 1989) with wall bracket with rawl plug.

3

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump).

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
450 lpm at 35 m Head

1

-

-

... More
Deep Boring

-

-

-

... More
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.

-

-

-

... More
(a) From 0.00 M to 50.00 M below G.L.

50

-

-

... More
(b) From 51.0 M to125.00 M

75

-

-

... More
(c) From126.0 M to150.00 M

25

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia

25

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge

2

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia

2

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp

2

-

-

... More
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 5 HP

1

-

-

... More
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I.

1

-

-

... More
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.

130

-

-

... More
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.

115

-

-

... More
Add 18% GST

18

-

-

... More
Add 1% Labour cess 1%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.