Rural Works Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Rural Works Department - RWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date11 Apr 2023
Closing Date21 Apr 2023
Tender Amount₹ 96,78,500 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Easing and adjusting door and window shutters with choukhats in old work complete as per specification and direction of E/I.

39

4381

112.35

... More
Providing and laying single layer of tar felt of standard make including cleaning the surface with brushes and cloth soaked in K oil, laying first layer of hot bitumen a/r 1.5 kg. per M2, second layer of tar felt and third layer of hot bitumen a/r 1 kg per M2, top finished with gravel, moorum, river shingles or sand a/r 0.057 M3/M2 as per I.S.S. manufacturers specification and direction of E/I.

137.7

58025

421.39

... More
Providing and laying 20 mm thick white markana marble stone slab flooring of approved quality over 19 mm thick base of lime mortar (1:1:1) (Lime putty surkhi coarse sand) laid and joined with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carbotandum stone including cost of curing taxes and royalty all complete as per building specification and direction of E/I.

236.54

423839

1791.83

... More
Labour for cutting old mosaic or precast terrazo tiles including cost of remoing dirt rubbing and polishing to granolithic finish with approved quality carborandum stone including cost of curring taxes and royality all complete as per building specification and direction of E/I.

236.54

86857

367.2

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

941.2

163834

174.07

... More
Providing and laying water proofing treatment on roof slab…do…do...all complete job as per specification and direction of E/I.

234.45

121205

516.98

... More
Covering of Treated surface with pcc do….do…..all complete as per building specification and direction of E/I.

234.45

47942

204.49

... More
Providing and applying plaster of paris putty on 2mm ….dodddo...all complete as per building specification and direction of E/I.

1935.07

366579

189.44

... More
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floor and taxes all complete as per building specification and direction of E/I.

1935.07

482722

249.46

... More
Providing and applying white based putty of average thickness 1mm…..dop….do….all complete as per building specification and direction of E/I.

1202.28

131626

109.48

... More
Finishing walls with textured exterior paint of required shade - new work (two or more coats applied @ 3.28 ltr/10 sqm) over and including ….do…do...all complete as per building specification and direction of E/I.

1202.28

260390

216.58

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of E/I. (cost of aluminium snap beading shall be paid in basic item) With float glass panes of 4.0 mm thickness

56.4

50844

901.5

... More
Supplying fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20x10x2mm at 100mm centres and braced with M.S. flat diagonals 20x3mm with top and bottom rails of T. iron 40x40x6mm with 38mm dia steelpulleys complete with bolts, nuts, locking arrangements, stoppers, handles including applying a priming coat of red paint, carriage, hoisting and taxes all complete as per building specification and direction of E/I.

6.3

33623

5337.11

... More
Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I.

62.7

7758

123.74

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes 110mm Rain water pipe.

72

19415

269.66

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. (i) Coupler 110mm

10

1041

104.14

... More
(ii) Bend 110mm

10

1147

114.79

... More
(iii) Stoe-110

10

1006

100.6

... More
Providing and fixing unplastised PVC pipe clips of approved design to unplasticised -PVC rain water pipes by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including….do…do…all complete job as per specification and direction of E/I.

30

7659

255.3

... More
Supplying fitting and fixing good quality, well dressed and well seasoned sal wood work in choukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/I.

4.23

280379

66362.06

... More
75mm overall thickness partition with 12.5 mm thick double skin fire rated glass reinforced Gypsum plaster board…do…do..all leads all complete as per direction of E/I.

17.4

27650

1589.12

... More
Supplying, fitting and fixing 35 mm thick solid core type decorative single leaf flush door shutters with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complet as per building specification and direction of E/I.

50.4

106772

2118.51

... More
Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.

806.4

87954

109.07

... More
Dismantling thaned sued roof with ballive rafters all leads all complete as per direction of E/I.

535.64

21827

40.75

... More
Dismantling patent stone floor including stacking serviceable materials in countable stack within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.

236.54

9639

40.75

... More
Providing & laying GCI sheet or CA sheet roofing in proper slap..do…do..all complete as per building specification and direction of E/I.

5.7

456000

80000

... More
Labour for fitting and fixing G.C.I. or C.A. sheet roofing in proper slope including the cost of “J” or “L” hooks limpet and bitumen washers, carriage of sheets to work site, and taxes all complete as per building specification and direction of E/I.

589.39

98139

166.51

... More
Providing 6 mm thick cement plaster (1:6) in ceiling with sand of F.M. 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.

234.45

43152

184.06

... More
Dismantling lime terracing upto av. 50mm depth, with Chisel and hammer including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.

273.16

48368

177.07

... More
Providing and laying 6mm precast commercial glazed tiles in walls over 12 mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing taxes and royalty all complete as per building specification and direction and of E/I. with commercial grade colour 15x15cm tiles.

273.16

364977

1336.13

... More
|The fastening barrackers of aluminum Alloy 6005 |TS/MS with Hert galvanized with serration and serrated washes to area…do…do….all complete as per building specification and direction and of E/I.

260.51

1044382

4008.96

... More
Carriage cost of material Sand lead 60 km.

47.53

48706

1024.76

... More
Cement + Steel lead km.

21.45

9384

437.5

... More
Stone Chips lead km.

13.85

3476

251

... More
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C

118

91686

777

... More
Wiring for twin control light point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit 2 way modular switch, modular plate, suitable G.I. box and earthing the point with 15 sqmm FR PVC insulated copper conductor single core cable etc as required.

4

3296

824

... More
Supplying and fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.

22

6314

287

... More
Supplying and fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.

18

6462

359

... More
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

120

27720

231

... More
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire

420

72660

173

... More
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 6 sqmm + 1 x 6 sqmm earth wire for AC

360

112680

313

... More
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 4 x 6 sqmm + 2 x 6 sqmm earth wire for essential TPn DB.

240

134640

561

... More
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 Ways (4+18 ways) double door.

4

8684

2171

... More
Supplying and fixing following way prewired vertical type TP & N MCB distribution board steel for 415V on surface and recess complete with loose wire box of sheet steel dust protected, duly powder, duly powder painted, inclusive of 200 amps tinned copper bus bar common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto terminal connector/neutral link, earthing etc as required (But without MCB/RCCB/Isolator) .8 way (8+12), Double door vertical type

2

9534

4767

... More
Providing and fixing following rating and capacity four pole MCCB in existind cubical panel board including drilling holes in cubicle panel making connection etc as required. 125 amps, 16KA, fixed termal setting.

2

6796

3398

... More
|Supplying and fixing 240 volts, 'C'series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required mae Legrand/Schneider/Siemens. 6/32A Single Pole.

36

5760

160

... More
|Supplying and fixing 240 volts, 'C'series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required mae Legrand/Schneider/Siemens. 40A TPN MCB.

24

27264

1136

... More
|Supplying and fixing 240 volts, 'C'series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required mae Legrand/Schneider/Siemens. 50/63A TPN MCB.

18

20448

1136

... More
Supplying and fixing following rating, TP&N 415 volts, residual current circuit breaker ,having a sensitivity current upto 300mA in the existing MCB DB complete with connections, testing and commissioning etc as required. 40A/300mA

4

7764

1941

... More
Supplying and fixing following rating, TP&N 415 volts, residual current circuit breaker ,having a sensitivity current upto 300mA in the existing MCB DB complete with connections, testing and commissioning etc as required. 63A/300mA

4

8744

2186

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 moudle (78mm x 78mm x 45mm)

24

3648

152

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4/5 moudle (78mm x 140mm x 50mm)

18

3294

183

... More
Supplying and fixing 2 pin Ceiling rose on the existing junction box/ wooden block including connection etc as required.

68

2788

41

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

8

440

55

... More
Installation, testing and commissioning of pre wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceilling/wall including connection with 1.5 sqmm FR PVC insulated required.

28

2716

97

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.

12

1212

101

... More
S/F Modular type electronic fan regulator :- Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.

12

3072

256

... More
ITC exhaust fan upto 450 mm sweep :- Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc as required.

12

672

56

... More
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm.

60

3480

58

... More
Supplying and drawing following pair 0.5 sqmm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required (2 pair).

60

1440

24

... More
Supplying and drawing co-axial TV cable RG-6 grad 0.7mm solid copper conductor PE insulated with PVC sheath in the existing surface /recessed PVC conduit as required.

60

2220

37

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps, one way switch

24

1440

60

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps, 3 pin socket outlet

18

1386

77

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

2

146

73

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet

2

146

73

... More
Earthing with copper plate 600mm x 600mm x 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc (but without charcol or cock and salt) complete etc as required .

2

18326

9163

... More
Providing and fixing 25mm x 5mm copper earth strip in 40mm & 4.5mtr long G.I. pipe for earth electrode etc as required. P/F 25 x 5mm coppler earth strip in pipe.

2

2228

1114

... More
S/L 5 SWG G.I. wire in ground- Supplying and laying 8 SWG G.I. wire at 0.50 mtr below ground level for conductor earth electrode, including soldering etc required.

60

7320

122

... More
MV cable Laying upto 95 sqmm in ground- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation sand.

90

17280

192

... More
Supplying of WAL Mounted Fan- Supplying and fitting of 1400 mm Sweep regular/standered model AC celling fan, including connection with 1.5 sqmm copper wire, down rod of standered length upto 30cm with all accessories as required.

12

25534

2127.91

... More
Supply of Exhaust metal Fan-Supply and fitting of 230mm, 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing commissioning etc as required.

2

2325

1162.93

... More
Providing and fixing of XLPE, Aluminium Armoured PVC Cable confirming to IS IS7908 (Part-1) 1988 of grade 1.1 KV make Havells/Finolex/Polycab. 3.5 core 95 sqmm 1.1 KV XLPE Al Ar Cable (1R from Main Line to LT Panel).

60

43715

728.59

... More
Supply 15/16W LED BULB.

8

1949

243.64

... More
Supplying and fixing recess mounted 18 watt LED vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilling including connection with 1.5 sqmm FR PVC insulated copper conductor cable and earthing.

42

33327

793.5

... More
SITC of flowing rating 90/100 W LED Flood Lighting luminarie with presure die cast housing and toughened glass cover IP 66 protecton LUMINOUS.

4

35340

8835

... More
1 x 28 watt T5 Tube light fitting.

28

11270

402.5

... More
Supplying fitting and fixing viterous white glazed earthen ware IWC of parry/Hindustan of any other ISS approved make 100 mm HCI 'P' trap 15 litre C.I. pull and let go flushing system of names or other ISS Equivalent make complete with all fitting C.I. or CC brackers 32mm alkathene/P|VC telescopic flush pipe about 2m long with one brash coupling and clams |G/I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50 gms 15mm PVC connection pipe 450mm long abd tge exposed pipe and cistern with two coats of approved paint over a coat or red oxied primer etc. all complete as per specification ands direction of E/I. 580 x 440mm with 10.00 ltr low level PVC cistern.

5

18957

3791.5

... More
Providing |& fixing salem stainless steel A ISI 304 (18/8) kitchen sink as per IS 13983 with e.i. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls whereever required 19.10 A 2 2-510 x 1040 bowl depth 250mm.

3

8771

2923.96

... More
Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry/Hindustan of any other IS approved make supported on pointed C.I. or R.s. (32 MCI brass west 15mm dia CI body brass spindle cock of approved quality of weight not less than 350 gms 32 mm PVC waste pipe 750mm long with brass coupling at one end and making plumber join etc all complete as per specification and direction of E/I.

3

5979

1993.16

... More
Providing and fixing C.P. brass bib cock of approved quality confirming to IS-8931-15 mm dia nominal bore approved brand C.P. fittings.

10

3803

380.35

... More
Providing and fixing PTMT extention nipple for water tank pipe, fitting and approved quality and colour, 15mm nominal bore weighting not less than 32 gms.

17

641

37.71

... More
Supplying labour & tools for fixing CPVC pipe with red lead and yarn of following normal bore with screwed and socketed joints on walss ceilling and floor including supplying and fitting of wall hooks or pipes clamps, wooden plug cutting pipe of size and threading ends if required etc all complete as per specification and direction of E/I. (pipe with socket to be supplied department entally free of cost). (a) 15mm nominal bore.

30

11593

386.45

... More
Supplying labour & tools for fixing CPVC pipe with red lead and yarn of following normal bore with screwed and socketed joints on walss ceilling and floor including supplying and fitting of wall hooks or pipes clamps, wooden plug cutting pipe of size and threading ends if required etc all complete as per specification and direction of E/I. (pipe with socket to be supplied department entally free of cost). (b) 20mm nominal bore.

30

13501

450.05

... More
Supplying labour & tools for fixing CPVC pipe with red lead and yarn of following normal bore with screwed and socketed joints on walss ceilling and floor including supplying and fitting of wall hooks or pipes clamps, wooden plug cutting pipe of size and threading ends if required etc all complete as per specification and direction of E/I. (pipe with socket to be supplied department entally free of cost). (c ) 25mm nominal bore.

30

16452

548.42

... More
Supplying & fitting gun metal following valve of approved quality, all complete as per approved design drawing, building & PHED specification and direction of E/I. 20mm dia.

6

2426

404.49

... More
Providing and fixing brass stop cock of approved quality with taxes, all complete as per approved design drawing, building & PHED specification and direction of E/I. 15mm dia.

3

1563

521

... More
Providing and placing on terrace (at all for levels) polyethlylene water storage tank ISI:12701 marked including the BIS licence No. with cover and suitable locking arrangment and making necessary holes for inlet, outlet and over flow pipes but with.

4000

34000

8.5

... More
Supplying fitting and fixing PVC pipes with ear of approved make confirming to ISI : 1729 including supplying nails and bobins short pieces, cutting loose collars lead and yarn for making lead chaulked joints, cutting pipes to size including (a) 110 mm dia.

20

5602

280.1

... More
Supplying fitting and fixing PVC pipes with ear of approved make confirming to ISI : 1729 including supplying nails and bobins short pieces, cutting loose collars lead and yarn for making lead chaulked joints, cutting pipes to size including (b) 75mm dia.

6

1119

186.59

... More
Supplying and fixing PVC fitting of approved make confirming to ISS : 1729 including supplying and bobins lead and yarm for making lead chauked joints including earth work or providing scaffolding as the case may be all complete as per specification & direction of E/I. (H) PVC plain Band with ear and door. 110 mm bend.

18

2081

115.63

... More
Supplying and fixing PVC fitting of approved make confirming to ISS : 1729 including supplying and bobins lead and yarm for making lead chauked joints including earth work or providing scaffolding as the case may be all complete as per specification & direction of E/I. (H) PVC plain Tee 100 mm dia.

8

1336

167.1

... More
Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type-A including jointing with seal ring confirming to IS:5382 leaving 10mm gape for thermal expansion (i) 100 mm dia door tee.

6

1079

179.97

... More
Supplying and materials with labour for construction inspection chamber of designation class 75B brick deep 600 x 450mm internal dismention haing 250mm wall thickness in cement mortar (1:6) including 12mm cp (1:4) with punning on inside and cement plaster (1:6) with 600 x 450mm G.I. cover with frame (weight not less than 36 kg) along with PCC (1:3:6) in foundation and refilling all complete as per approved design, drawing, building |& PHED specification and direction of E/I.

6

33802

5633.81

6

1182

197

... More
Steel Jali

10

390

39

... More
Floor trap

10

2310

231

... More
Pressure adjustable shower with revolving joints.

2

1500

750

... More
E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.

27.36

4578

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)

0.9

530

589.51

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I.

11.85

4221

356.22

... More
Providing PCC M-200 in nominal mix (1:1½:3) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking curing, taxes and royalty all complete as per building specification and direction of E/I.

2.4

14375

5989.72

... More
Providing designation 75A brick work in cement mortar (1:4) in foundation & plinth with approved quality of clean coarse sand of FM 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials raking out joints to 15 mm depth curing taxes & royalty all complete as per building specification and direction of E/I.

6.05

33990

5618.23

... More
Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.

34.6

7906

228.5

... More
Providing 6 mm thick cement plaster (1:4) ceiling of cover slab of F.M. 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.

4.84

890

184.06

... More
Providing RCC M-200 with nominal mix of (1:1.5:3) in cover slab with approved quality of stone chips 20mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing ((but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.

1.04

6561

6308.87

... More
Providing RCC M-200 with nominal mix of (1:1.5:3) in lintel of all types with approved quality of stone chips 20mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing ((but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.

0.04

252

6308.87

... More
Providing Tor steel reinforcement of RCC work as per approved design and drawing excluding carriage of bars to work site, cutting bending and binding with annealed wire cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.1

7799

82096.54

... More
Carriage cost of material Sand lead 60 km.

5.75

5892

1024.76

... More
Stone Chips lead 8 km.

4.25

1066

251

... More
Bricks lead 10 km.

2890

2258

781.6

... More
Cement lead 5 km.

3.05

1423

466.7

... More
Add cost of TV

4

219280

54820

... More
Goods & Service Tax (G.S.T.) -

7136085.29

1284495

0.18

... More
Add cost of projector with GST

2

833000

416500

... More
Add cost of sound system with GST

1

278280

278280

... More
Add Signboard & Photography

1

5000

5000

... More
Labour Cess -

9536836.04

95368

0.01



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.