Rural Development Department Tender

... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Rural Development Department - RDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Feb 2025
Closing Date10 Feb 2025
Tender Amount₹ 24,99,008 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I.

46.9

330

15492.62

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:2:4 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 20 mm nominal size)

4.34

4598

19947.12

... More
Centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bades of columns, etc. for mass concrete.

1.96

194

381.8

... More
Providing 50mm th cement concrete flooring 1:2:4 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 20 mm nominal size) with flooring coat of neat cement do-do.

12.27

505

6201.81

... More
Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centering, shuttering, finishing and reinforcement- all work up to plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand (zone-iii): 3 graded stone aggregate 20 mm nominal size).

1.69

5218

8802.77

... More
Centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bades of columns, etc. for mass concrete.

9.2

194

1789.59

... More
Reinforced cement concrete work in walls (any thickness), including attached plasters, buttresses, plinth and string courses, fillets, column pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand (zone -iii):3 graded stone aggregate 20 mm nominal size)

0.98

6082

5936.47

... More
Reinforced cement concrete work in walls (any thickness), including attached plasters, buttresses, plinth and string courses, fillets, column pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand (zone -iii):3 graded stone aggregate 20 mm nominal size)

3.12

6082

18977.24

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, piers, Abutments, posts and Struts.

24.68

465

11485.58

... More
Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3

2.76

6308

17412.48

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers

10.84

363

3943.61

... More
Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3

1.39

6308

8763.02

... More
Centering and shuttering including strutting, propping etc. and removal of form for Chajjas

10.28

445

4580.25

... More
Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3

22.02

6308

138921.32

... More
Centering and shuttering including strutting, propping etc and removal of form for Suspended floors, roofs, landings, balconies and access platform

147.09

435

64104.76

... More
providing Tor steel reinforcement of 8, 10 mm and 12 mmmm dia bar as per approved design and drawing excluding carraige of M.S.bars to work site , cutting, bending, and binding with annealed wire with cost of wire removal of rust placing the rod in position all complete as per building specification and direction of E/I 8 mm Dia

1.57

83314

131027.96

... More
(a) 10mm Dia

1.18

82096

96832.87

... More
(b) 12mm & 16mm Dia

1.18

80879

95396.86

... More
Providing designation 75A brick in C.M. (1:6) in foundation and plinth with approved quality of clean sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints , cost of screening materials raking out joints to 15 mm depth , curing , taxes and royality all complete as per building specification and direction of E/I

3.44

5439

18723.96

... More
Providing 75A brick work in C.M (1:6) in super structure and plinth with approved quality of clean coarse sand ---- do---do--- as per direction of E/l.

72.01

5573

401363.32

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with fine sand including finishing the top smooth.

31.63

351

11125.89

... More
Providing 150mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.

51.88

718

37259.38

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

256.36

165

42504.49

... More
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

268.26

174

46696.02

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

97.52

184

17949.53

... More
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.

1006.98

127

128289.25

... More
Finishing wall with textured exterior paint of required shade New work ( Two or more coats applied @ 3.28ltr/ 10sqm) over and including primer coat of exterior primer applied @ 2.2./10sqm

405.35

182

74000.7

... More
DOORS & WINDOWS WORKS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge Fixing with adjustable lugs with split end tail to each jamb

87.5

511

44760.63

... More
S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.)

828.72

82

68212.03

... More
Supplying, fitting & fixing 35 mm th. Solid core type decorative single leaf FLUSH DOOR SHUTTERS in doors with block board core blended with high quality phenol formal dehydes synthetic resinboth side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts , handle,cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I

18.22

1614

29402.81

... More
Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size,

11.9

4283

50952.23

... More
Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I.

1006.98

90

90789.23

... More
Finishing walls with Premium Acrylic Smooth exterior paint with of required shade: Old work(Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing paint surface

405.35

111

45237.51

... More
Providing and fixing fan hook of 16mm dia TMT M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C slab/beam at the time of of casting all complete as per building specification and direction of E/I

4

149

598.08

... More
Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curring, taxes and royalty all complete as per building specification and direction of E/l.

7.03

238

1676.58

... More
Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) Multiplying Factor-1.2 (for each side) as per Table -1 [IS:1200]

118.96

57

6872.09

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.

99.13

66

6546.55

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 MM

42

319

13429.5

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler - 110mm

4

119

479.8

... More
110 mm bend

5

132

660

... More
Shoe - 110

6

115

695.7

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. Clip 110mm Clips

15

309

4642.5

... More
Providing two coats of painting with ready mixed paint over a coat of primer of approved shade and make over new wooden surface including preparing the surface after cleaning, removing dirt - do - of E/I. Multiplying Factor-1.2 Each side

90.41

111

10123.66

... More
Providing and laying double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer ) with water absorption less than 0.08% and confirming to IS 4457:2007 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigment etc,complete.Size of tile 300x300x10mm

17.19

950

16339.02

... More
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C Hindustan or any other I.S.S. Approved make with 100mm H.C.I. 'P' trap 10 liter C.I. Pull and let go flushing cistern of names or other I.S.S. Equipment make, complete with all fitting, C.I. or C.C.brackets 32mm alkathene/P.V.C. telesscopic fjush, pipe aboout 2M -do- -do- all complete job as per specification and direction of E/I.n

2

4384

8768.92

... More
Providing and fixing 1mm thick PVC rigid foam sheet over w.c.'s door shutter using synthetic rubber based adhesive (Fevicol SR 998 or equivalent).

2.79

1121

3125.52

... More
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all compere as per specification and direction of E/I.

2

354

709.18

... More
Providing and fixing N.P./C.P. brass/PVC procelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/I. Shower Rose - 125mm

3

170

510.24

... More
Providing & fixing 15mm size pillar cock C.I. body brass spindle pillar cock of approved quality as per specification & direction of E/I.

2

301

603.42

... More
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. 15 mm dia

2

282

564.58

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes

5

441

2205.75

... More
20 mm nominal outer dia Pipes

5

513

2568.75

... More
Carriage of materials Bricks

32158

2094

67351.72

71

714

50728.06

... More
Stone chips

31.38

714

22423.78

... More
Cement

23.73

1004

23843.9

3.93

1004

3950.87

... More
Electric work Wiring for light /fan point / exhause fan point / call bell point with 1.5 sq.mm FRPVC inlsulated copper conductor single core cable in surface / recessede conduit with paino type switch phenolic laminated sheet suitable size M.S box insulated copper conductor. Group - A

12

592

7104

... More
Wiring for light /power pluge with 2x4sq.mm FRPVC insulated copper conductor single core cable in surface / recessede PVC conduit along 1 No Sqmm FRPVC insulated copper conductor single core cable for loop earthing as required.

15

262

3930

... More
Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire

25

196

4900

... More
2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire

20

262

5240

... More
2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire

20

147

2940

... More
Supplying and fixing suitable sizes G.I/PVC box on surface or inrecess with phenolic laminated sheet cover in frong including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps paino type switch connection painting etc as required.

8

199

1592

... More
Supplying and fixing suitable size GI/PVC box of 121 mm x 173 mmx 48 mm /(6"x8") (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providng and fixing 6 pin 15/ amps paino type switch connection painting etc as required.

8

335

2680

... More
S/F following rating double pole 240 volts isolator in the existing MCB DB complete with connection testing and commissoning etc as required. 40 amps

1

315

315

... More
63 amp DP

1

373

373

... More
Providing and fixing following capacity DP/TP&N sheet metal/switchs disconnector fuse unit in existing metal board with rewireable type fuse including drilling holes in metal board making connection earthing the body etc as required. 100 amp TP&N

1

6818

6818

... More
200 amp TP&N

1

10807

10807

... More
Providing and fixing following capacity busbar, chabmer with 4 strips of suitable sizes made of copper, heavy duty complete with all accessories including connections earthing the body 100 Amp busbar chamber

1

3910

3910

... More
200 Amp busbar chamber

1

7977

7977

... More
S/F S.P MCB DB Supplying and fixing following way single pole netural sheet MCB distribution board 240 volts on surface / recess complete with tinned copper busbar netrual ibulsbar earth bar din bar detachable gland plate interconnections phosphatized and powder painted including earthing etc as required (But without MCB/RCCB/ Isolator) 6 way single door

1

719

719

... More
8 way single door

1

841

841

... More
S/F PVC/GI box fo following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront incliuding painting etc 170 mm x 221 mm x 48 mm deep /(8"x10") for MCB

2

223

446

... More
S/F 2 pin 5 amp celling rose on the existing junction box/wooden block including connection etc

4

45

180

... More
Supplying and fixing batten / angle holder including connection etc as req.

10

59

590

... More
S/F following paino type switch /socket on the existing switch box/ cover including connection etc as req. Electronic step fan regulator, deluxe

4

159

636

... More
S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required 20/22 W LED Tube light

4

628

2512

... More
15/16 Watt LED Bulb

4

229

919.6

... More
Supply, installation, testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard for 230V 50 Hz, single phase supply etc. complete as required 1200mm(48'') Ceiling Fan

4

1748

6992

... More
S/F/F 4'x3' size of panel board made of commercial board mounted on MS angle frame including the cost of grouting the same on wall all complete as req.

1

2850

2850

... More
18% G.S.T

2096834.77

-

377430.26

... More
1% L.C.

2474265.02

-

24742.65



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.